Loading...
BLD2021-1189_Manufacturer_Specifications_and_Installation_Instructions_8.25.2021_4.23.03_PM_2376699Job Name: System Reference: Date: Indoor Unit........SVZ-KP36NA ....................................................................... Outdoor Unit SUZ-KA36NAHZ .................................................................... . dlli!IIIIIIIIIIIIIIIIIIIIII!Iiilr:. ,I IEilllllllillliilillllllllllll 11 llllllliill� IIIIIIIIIIIIIIIIIIIIIIII91111111111�iiiillllPil '''INlIIIIIIIIliliiilllllllllllllllll!I�`' ""�IIIIIIIIIIIIIIIIIIjO��. INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 In.WG (Tested perASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (up or down) • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control - Built-in humidifier control, ERV control and auxiliary heat control • Optional downflow kit • Multiple control options available: o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance - 1­12i° hyper heat performance offers 100% heating capacity at 5° F • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life • Built-in base pan heater • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity _ Minimum Capacity BTU/H 36,000 36,000 14,200 BTU/H BTU/H Maximum Power Input W 3,760 3,760 Rated Power Input W Moisture Removal Pints/h 8.4 Sensible Heat Factor 0.74 Power Factor % 97.0/97.0 Heating at 47°F2 Maximum Capacity BTU/H 40,000 Rated Capacity BTU/H 37,000 Minimum Capacity BTU/H 13,800 Maximum Power Input W 4,160 Rated Power Input W 3,280 Power Factor % 98.0/98.0 Heating at 17°F' Maximum Capacity BTU/H 37,000 Rated Capacity BTU/H 32,800 Maximum Power Input W 5,800 Rated Power Input W 4,230 Heating at 5°F° Maximum Capacity BTU/H 37,000 Maximum Power Input W 6,590 Heating at -13°F7 Maximum Capacity BTU/H 29,600 Efficiency SEER 16.0 EER' 9.5 HSPF [IV] 9.0 COP at 47°F2 3.3 COP at 17°Fat Maximum Capacity3 1.8 COP at 5°F at Maximum Capacity' 1.6 COP at -13°F at Maximum Capacity' 1.2 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor -Outdoor, S1-S2 VAC 208/230 Voltage: Indoor -Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 35 Recommended Wire Size [Indoor- Outdoor] AWG 14 Indoor Unit MCA A 4.13 Fan Motor Full Load Amperage A 3.3 Fan Motor Output W 244 Airflow Rate at Cooling, Dry CFM 767-910-910 Airflow Rate at Heating, Dry CFM 767-910-910 Sound Pressure Level [Cooling] dB[A] 35-40-42 Sound Pressure Level [Heating] dB[A] 35-40-42 External Static Pressure in.WG 0.30-0.5-0.8 Drain Pipe Size In. [mm] 3/4 [19.05] Coating on Heat Exchanger — External Finish Color Hot -dip coated steel (ZAM) Unit Dimensions W x D x H: In. [mm] 21 x 21-5/8 x 43-3/4 [533 x 549 x 1111] Package Dimensions W x D x H: In. [mm] 22 x 28-3/4 x 48-3/8 [558 x 730 x 1,228] Unit Weight Lbs. [kg] 119 [54] Package Weight Lbs. [kg] 141 [64] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 95 DB, 71 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB 115 DB, 4 WB 'Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB H -5 DB, -6 WB 71-leating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • For P-Series only: u Wind baffles required to operate below 23°F DB in cooling mode. u Cooling -only system with wind baffle: -40°F - 115°F. » Heat pump system with wind baffle: 0°F - 115°F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLYAPPLIES TO P-SERIES -BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP _ Fan Motor Output A 26.0 A 42 W 74 Airflow Rate CFM 590/680 Refrigerant Control LEV Defrost Method Reverse Cycle Sound Pressure Level, Cooling' dB(A) 52 Sound Pressure Level, Heating2 dB(A) 53 Compressor Type Scroll Compressor Model ANB33FJMMT Compressor Rated Load Amps A 18.0 Compressor Locked Rotor Amps A 27.5 Compressor Oil Type H Charge oz. FV50S H 1.4,47 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm] 41-5/16 x 14-3/16 x 52-11/16 [1050 x 360 x 1338] Package Dimensions W x D x H: In. [mm] 43 x 18 x 57 [1110 x 480 x 1440] Unit Weight Lbs. [kg] 261 [118] Package Weight Lbs. [kg] 285 [129] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB 10 DB Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock -out / Re -start Temperatures** °F -22 / -13 Refrigerant Type R410A Charge Lbs, oz 11,7 Chargeless Piping Length Ft. [m] 100 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.6 [56] Piping Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Maximum Piping Length Ft. [m] 245 [75] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB 1147 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 51-leating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB sHeating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB H -5 DB, -6 WB 71-leating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB H -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. For P-Series only: • Wind baffles required to operate below 23°F DB in cooling mode. • Cooling -only system with wind baffle: -40°F - 115°F. n Heat pump system with wind baffle: 0°F - 115°F. Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLYAPPLIES TO P-SERIES -BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Control Interface BACnet® and Modbus Interface CN24 Relay Kit Connector cable for remote display IT Extender kumo station® for kumo cloud® Remote Operation Adapter; Thermostat Interface USNAPAdapter ❑ PAC-UKPRC001-CN-1 ❑ CN24RELAY-KIT-CM3 ❑ PAC-SA88HA-EP ❑ PAC-WHS011E-E ❑ PAC-WHS01 HC-E ❑ PAC-SF40RM-E ❑ PAC-US444CN-1 ❑ PAC-WHS01UP-E Wireless Interface for kumo cloud® ❑ PAC-USWHS002-WF-2 Flush Mount Temperature Sensor ❑ PAC-USSEN001-FM-1 Remote Sensor Remote Temperature Sensor surface mount ❑ PAC-SE41TS-E Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Controller Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB Deluxe Wired MA Remote Controllert ❑ PAR-40MAAU Simple MA Remote Controllert ❑ PAC-YT53CRAU J Touch MA Controllert ❑ PAR-CT0IMAU-SB kumo touch" RedLINK' Wireless Controller ❑ MHK2 Wireless Remote Controller Wireless MA Receiver ❑ PAR-FA32MA-W Wireless MA Remote Controller ❑ PAR-FL32MA-E Condensate Blue Diamond Sensor Extension Cable — 15 Ft. ❑ C13-103 20/2PR, 1 PR shielded + 1 PR plenum wire for Airzone, 100 ft reel ❑ CW2042S2-100 Control Wire 20/2PR, shielded + 1 PR plenum wire for Airzone, 500 ft reel ❑ CW2042S2-500 (30A/600V/UL) [fits 2" X 4" utility box] - Black 1-1TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4' utility box] - White ❑ TAZ-MS303W Downflow Kit Downflow Kit ❑ DFK-M Electric Heat Lockout Electric Heat Lockout ❑ ETC-211000-MIT 10kW Electric Heater ❑ EH10-SVZ-M Electric Kit Heats 5kW Electric Heater ❑ EH05-SVZ-M 8kW Electric Heater ❑ EH08-SVZ-M 10' x 3/8" x 10' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 100' x 3/8" x 100' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 15' x 3/8" x 15' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 Lineset 30' x 3/8" x 30' x 518" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-30 50' x 3/8" x 50' x 518" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 65' x 3/8" x 65' x 518" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 Terminal Block Separate Terminal Power Block ❑ SPTB1 NOTES: +Requires MAC-3341F-E • M-Series EZ FIT® Recessed Ceiling Cassette, Floor -mount and Wall -mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller tPAC-SF40RM-E (Unable to use with wireless remote controller) M-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler P-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Drain Pan M- & P-Series Maintenance Tool Cable Set USB/UART Conversion Cable (Required for all laptop connection) Drain Socket Hail Guard ❑ PAC-SH96SG-E (two pieces are required) Centralized Drain Pan ❑ PAC-SH97DP-E Control/Service Tool ❑ M21 EC0397 ❑ M21 EC1397 Drain Socket ❑ PAC-SH71 DS-E Hail Guards ❑ HG-A2 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 Mounting Pad Condensing Unit Mounting Pad: 24" x 42" x 3" ❑ ULTRILITE2 18" Dual Fan Stand ❑ QSMS1802M Stand 24" Dual Fan Stand ❑ QSMS2402M Outdoor Unit Stand — 12" High ❑ QSMS1202M Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. o26 Knockout Hole (Indoor / Outdoor unit connection) Renate controller transmission) Left side wew Unit:mm(in.) view o26 Knockout Hole o26 Knockout Hole for electrical heat wiring 2-o4.6 Burring Holes for electric heat installation IIL (E er9en y°a:atr°n9) o19.05(3/4) 3/4"FPT- Secondary drain pipe \ 1, ergeno Drain (Emergency draining) .19.05(3/4) 3/4"F 019.05(3/4) 3/4-FPT (Horizontal Right) Model Nominal Filter Size Duct Connection 508 x 406.4 x 25.4 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) rSVZ-KP12NAKP18NA KP24NA(20 KP30NA 508 x 508 x 25.4 (20 x 20 x 1) 477 x 402 (18-13/16 x 15-7/8) KP36NA Bottom view QAIr inlet A Primary drain pipe (Gravittyv drain) .1..05(3/4) 3/4"FPT Contml bcx -(Remove Blower Panel) Unit:mm(in.) Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. Right side view Model A B C D E F G H J Gas Pipe Liquid pipe SVZ-KP12NA 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1,010.8 (39-13/16) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) o 9.52 (3/8) o 6.35 (1/4) SVZ-KP18NA 0 12 7 (1/2) SVZ-KP24NA o 15.88 (5/8) o 9.52 (3/8) SVZ-KP30NA 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) SVZ-KP36NA Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1 FREE SPACE (Around the unifl The diagram below shows a basic example. Explanation of particular details are given in the installation manuals etc. 2 SERVICE SPACE 1 13 FOUNDATION BOLTS nimensians of space for service access ai shown in the below di Exomple of Not eS O1 Refrigerant GAS pipe connection (F LARE)015.88(5/8F). O -RefrigeronI LIQUID pipe connection (FLARE)0952(3/8F). '1 -indication of VALVE connection location. Piping Knock -Out Hole Detailes Renr hinkrg�M1ole 5t Cbrltl � IKmck Oull 1/16�LK.IGiod-0ull (mdil be be $ 5< (mrlil be 113/A HI64N(mck Oull C tl 1 Me' 113/A ril6(N(rad-0ull km11NM9 hole INrrckMl 0921 n Rear ppng Mle - � � ^� IKno[k-Gull _ � Front eying ble n � • IXn k II 0 CO � c C^' m 0 m 00 a N N (n N 7 (D N (D D m n o 0 4 PIPING -WIRING DIRECTIONS C 3 3 3 n V