Building Permit 2020'S IDENTIAL BLDG
Permit
PERMIT NUM
of Edmonds
EdmondsCity
98020BLD2019-15513
wwm
www.edmondswa.gov
Type: RESIDENTIAL BLDG
Owner/ Business: HOY GREGORY & OKA MIDORI
Status: ISSUED
Subtype: NEW SINGLE FAMILY
Parcel No: 27041800103800 Site Address: 8051 184th ST SW EDMONDS,WA 98026
Applied: 12/10/2019
Subdivision: SP S-7-86, 004343
Lot:
Issued: 2/2/2021
Fire Sprinklers: Yes Lot
Area: 0 Zoning:
Final:
Valuation: $513,238.05 Occupancy Type: R3 Construction
Type: VB
Expiration Date: 1/28/2022
Code Edition: 2015 No. Stories: 2 # of Dwelling
Units: 2
Issued by: NED
Scope of Work: HOY: NEW SFR WITH ADU, PLUMBING AND MECHANICAL INCLUDED
WA State Contractor L & I #: City of Edmonds Business License #: 602454996-001-0001
CONTACTS
NAME TYPE NAME
ADDRESS
PHONE
EMAIL
CONTRACTOR WAYNE SHARP
20012 HWY 2 SUITE F ,
(206)931-7745
waynesharp.office@gmail.com
CONSTRUCTION
MONROE WA 98272
OWNER HOY GREGORY & OKA
8051 184TH ST SW, EDMONDS
(206)696-2967
greglhoy@gmail.com
MIDORI
WA 98020
FEE INFORMATION
DESCRIPTION
ACCOUNT AMOUNT
PAID
PAID DATE
RECEIPT#
1 - BASE FEE FOR MECHANICAL
001.000.322.10.000.00
$50.00
$50.00
2/1/21
R10194
PERMITS
1 - BASE FEE FOR PLUMBING
001.000.322.10.000.00
$50.00
$50.00
2/1/21
R1 1194
PERMITS
2019 TRANSPORTATION IMPACT
112.502.345.86.000.00
$6,249.14
$6,249.14
2/1/21
R10194
FEE
APPLIANCE VENTS
001.000.322.10.000.00
$30.00
$30.00
2/1/21
R10194
B-BUILDING PERMIT FEE
001.000.322.10.000.00
$3,570.00
$3,570.00
2/1/21
R10194
B-BUILDING PLAN REVIEW FEE
001.000.345.83.000.00
$2,950.00
$2,950.00
12/17/19
R1325
B-STATE BUILDING CODE
001.000.237.150
$6.50
$6.50
2/1/21
R10194
SURCHARGE
EACH PLUMBING FIXTURE ON ONE
001.000.322.10.000.00
$195.00
$195.00
2/1/21
R10194
TRAP
EACH VENT OR EXHAUST NOT
CONNECTED TO A HEATING OR AC
001.000.322.10.000.00
$60.00
$60.00
2/1/21
R10194
SYTEM
ENGINEERING INSPECTION FEE
001.000.341.82.000.00
$880.00
$880.00
2/1/21
R10194
ENGINEERING REVIEW FEE - OVER 3
001.000.341.82.000.00
$220.00
$220.00
2/1/21
R10194
REVIEWS
FAN CONNECTED TO SINGLE DUCT
001.000.322.10.000.00
$15.00
$15.00
2/1/21
R10194
FIRE AID SIGN FABRICATION FEE
111.000.68.542.64.31.00
$100.00
$100.00
2/1/21
R10194
FURNACE OR FIREPLACE
001.000.322.10.000.00
$60.00
$60.00
2/1/21
R10194
GAS PIPING - NEW OR LOCATED
001.000.322.10.000.00
$30.00
$30.00
2/1/21
R10194
PARK IMPACT FEE - SINGLE FAMILY
332.100.345.85.000.00
$2,734.05
$2,734.05
2/1/21
R10194
Printed: Wednesday, February 03, 2021 10:52:25 AM 1 of 4
DESCRIPTION
ACCOUNT AMOUNT
PAID
PAID DATE RECEIPT #
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$260.00
$260.00
2/1/21
R10194
FEE
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$130.00
$130.00
2/1/21
R10194
FEE
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$260.00
$260.00
2/1/21
R10194
FEE
STORMWATER GENERAL FACILITY
422 000.379.00.000.00
$1,471.49
$1,471.49
2/1/21
R10194
CHARGE SFR OVER 5000
TRANSPORTATION IMPACT ADMIN
001.000.341.82.000.00
$50.00
$50.00
2/1/21
R10194
FEE - SFR
WATER HEATER - INCLUDING
001.000.322.10.000.00
$15.00
$15.00
2/1/21
R10194
EXPANSION TANK
WATER HEATER - TANKLESS
001.000.322.10.000.00
$15.00
$15.00
2/1/21
R10194
X-TECHNOLOGY FEE
001.000.321.99.100.00
$35.00
$35.00
2/1/21
R10194
TOTALS: $19,436.18 $19,436.18
CONDITIONS
CONDITION TYPE
STATUS
NOTES
48 HRS NOTICE-ENGR FINAL
O
48 Hours notice is required when requesting your FINAL engineering inspection.
ORMATION
Contractor/Owner shall be responsible for repair/replacement of all damage to utilities
DAMAGE TO FRONTAGE
FOR
and/or frontage improvements in city right of way per city standards that is caused by or
IMPROVEMENTS
INFORMATION
occurs during the permitted project.
Electrical Permit
Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
ESC REQUIRED
FOR
Maintain erosion & sediment control per city standards.
NFORMATION
In addition to the required pressure/relief valve, an approved listed expansion tank shall
Expansion Tank
be installed on all hot water tanks. Per UPC 608.
Approval of this foundation design is conditional subject to inspection of existing site soil
conditions.
Foundation Bearing
Retaining Walls must be designed and constructed to resist the lateral pressure of the
retained material.
Provisions must be made for the control and drainage of surface water around buildings.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests,
agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its
officials, employees, and agents from any and all claims for damages of whatever nature,
Hold Harmless
arising directly or indirectly from the issuance for this permit. Issuance of this permit shall
not be deemed to modify, waive or reduce any requirements of any City ordinance nor
limit in any way the City's ability to enforce any ordinance provision.
Hose Bibbs (exterior faucets) are required to have a permanently affixed anti -siphon
Hose Bibbs
device installed.
INSPECTION PRIOR TO BACKFILL
FOR
Call for all required inspections. All work shall be inspected prior to backfill.
NFORMATION
Lot Lines Staked
Lot line stakes must be in place at the time of foundation/setback inspection.
Printed: Wednesday, February 03, 2021 10:52:25 AM 2 of 4
MIDENTIAL BLDG Permit
PERMIT NUM
of Edmonds
EdmondsCity
98020D2019
www.edmondswa.gov •
Maximum Height 25 feet. The agent/contractor shall set up the equipment; establish the
datum point and the point of average grade. Call for inspection to verify. These items
Maximum Height
must be consistent with the approved plan. If the proposed height of a building (as
shown on the plans) is within 12 inches of the maximum height permitted for the zone an
elevation survey is required.
Final approval on a project or final occupancy approval must be granted by the Building
Occupancy
Official prior to use or occupancy of the building or structure. Check the job card for all
required City inspections including final project approval and final occupancy inspections.
Any request for alternate design, modification, variance or other administrative deviation
(hereinafter "variance") from adopted codes, ordinances or policies must be specifically
requested in writing and be called out and identified. Processing fees for such request
shall be established by Council and shall be paid upon submittal and are non-refundable.
Permit Disclaimer
Approval of any plat or plan containing provisions which do not comply with city code
and for which a variance has not been specifically identified, requested and considered
by the appropriate city official in accordance with the appropriate provision of city code
or state law does not approve any items not to code specification.
PROJECT ASBUILT
FOR
Electronic project asbuilt shall be submitted to the City prior to final project acceptance.
NFORMATION
Pursuant to UPC 608 a pressure regulator valve (PRV) shall be installed near the water
PRV Required
shutoff.
Sound/Noise originating from temporary construction sites as a result of construction
activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of
Sound/Noise
7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction
sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has
been granted pursuant to ECC 5.30.120.
UNDERGROUND UTILITY
FOR
Call for locates of underground utilities prior to any excavation.
LOCATES
INFORMATION
All new, extended, re -built or relocated electrical utility and/or service shall be placed
Underground Wiring
underground.
Type B or L vent connectors required on fuel -burning appliances passing through
Vent Connectors
unheated spaces. Per IMC 803.2
City approved plastic piping may be used in water service piping provided that where
metal water service piping is used for electrical grounding purposes, replacement piping
Water Service Piping
shall be of like materials (UPC 604.8). A state electrical permit and inspection is required
if electrical grounding is altered, removed, improved, or added. Contact State Dept. of
Labor & Industries Electrical Division at 425-290-1400.
Water Service Shutoff
Pursuant to UPC 605.2 a water service shutoff shall be installed on the water line as it
enters the building.
Installer shall provide the manufacturer's installation, operating instructions, and a whole
Whole House Fan
house ventilation system operation description. A label shall be affixed to the whole
house timer control that reads "Whole House Ventilation" (see operating instructions).
INSPECTIONS
- Schedule Online
at: https://Inspection.MVBuildingPermit.com
COMPLETED
SEQID INSPECTION TYPE
INSPECTOR
RESULT NOTES
DATE
E-5 ENG SPECIAL INSPECTION
A-1 ENGINEERING PRECON
A-1 TESC AND MOBILIZE
E-3 STRM COVENANT
Printed: Wednesday, February 03, 2021 10:52:25 AM 3 of 4
'SIDENTIAL BLDG PermitCity PERMIT NU
• • • •
•:� i 1 ' -
-. •.
E-3 STRM FOOTING DRAIN
E-3 STRM MGMT FACILITY
E-3 STRM PERVIOUS
SURFACES
E-3 STRM TIGHTLINE
E-4 ACCESS WIDTH SLOPE
E-4 WATER SERVICE LINE
E-5 PRIVATE ROAD
E-9 PROJECT ASBUILTS
X-2 ENGINEERING FINAL
B-1 SETBACKS
B-2 FOOTINGS
B-2 FOUNDATION WALL
B-2 PT PRECON
B-2 RETAINING WALL
B-3 GAS PIPING TEST
B-3 MECH ROUGH IN
B-3 PLUMB ROUGH IN
B-3 UNDERFLR FRAMING
B-4 FRAMING
B-4 HEIGHT VERIFICATION
B-4 INTERIOR SHEAR
B-5 BLDG SPECIAL
INSPECTION
X-3 BUILDING FINAL"
B-3 PLUMB GROUND WK
B-4 DRYWALL FASTENING
B-2 SLAB INSULATION
B-3 STUCCO
B-5 INSULATION ENERGY
B-2 RETAINING WALL
E-4 STRM STUB CONNECT
Printed: Wednesday, February 03, 2021 10:52:25 AM 4 of 4