Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ENG2020-0359 ROW PERMIT
RIGHT OF WAY EUC PERMIT PERMIT NUMBER] City of Edmonds www.cityofedmonds.gov 777 Description: PUD-REPLACE 8 BAD ORDER POLES; VARIOUS LOCATIONS (POLES A-H) ISSUED: 09/13/2021 Address: 856 DALEY ST EDMONDS WA 98020-3951 EXPIRES: 03/13/2022 rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434208101700 i NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER SMITH MARY PAULINE 856 DALEY ST, EDMONDS WA 98020-3951 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 09/13/2021 :»•>/F9:1H ]1 DATE Printed: Monday, September 13, 2021 1:21:46 PM 1 of 2 -KRWOF WAY EUC PERMIT City of • • • www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION MEN RESULT X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL A-1 JOB START E-7 RESTOR LIMITS Printed: Monday, September 13, 2021 1:21:46 PM 2 of 2 ��� aF F c�Ai°tip �. � ,J, PUD WORK ORDER 100047892 RECEIVED 9/18/20 ROW PERMIT NO.: ENG2020-0359 ISSUE DATE: 9/13/21 RIGHT-OF-WAY CONSTRUCTION !NC' 1 S90 PERMIT APPLICATION ENG2020-0359 — 856 Daley St. — Poles A thru H PROJECT NAME: Replace 29 Utility Poles CONTRACTOR: Snohomish PUD Mailing Address: PO Box 1107 State License #: City Business License #: CONTACT: Ben Ice Phone #: 425 783 4355 Fax #: 425 267 6072 Email #: btice@snopud.com ❑ Liability Insurance ❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 305 10th Ave S, Edmonds ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑ Other ❑■ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit9 ANY ASSOCIATED PERMITS? ❑ Yes ❑■ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) : Replacing 29 old utility poles with new. Final height of new poles will be the same as the old ones. The poles are being moved as far from the pavement as is feasible given the existing property rights. All poles in sidewalk are moving behind the sidewalk. THIS PERMIT IS FOR 8 POLES ONLY (POLES A-H) WAS STREET OVERLAYED WITHIN THE LAST FIVE (5 YEARS? YES NO Year: PAVEMENT CUT: ❑ Yes ❑■ No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes ❑■ No If yes, indicate size of cut: x RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE DATE 5/24/2020 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE Z �856 2 =- SPRAGUE ST F015 15 116523 E N NORTH FU15 ------------- E7-: 412 905 W 37-10766 SL-101228-0 8 CI------------------------------- ----------_------------ -----------------Q-------- --------------------Q 9ID 50 220 912 0 033 7-5873 911 ----------------- Z 2 11 15 O TO MAPLEWOOD CKT 12-346 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROLAND DRAINAGE CC HFMATTr DALEY ST 17Ti- - - FU40 © Q 896 U SL-128624B z Q J S O F-- O ------- "--- ---- ---- --------------v------------------------ U----------------------- Q-------------- •y, SPRAGUE ST 898 46(I is-3asa1 SL-129784-A ------ ------ ---- - EDMONDS ST - - EL-E=::z PLAN T. _ 0 15 OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. TO MAPLEWOOD CKT 12-346 OA POLE PLI # 705 CURB SET 45'CL 2 POLE (PW2045) IN PLACE SET DEPTH = 6.5' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 10 TANG ASSY (12V101) RMV 15 KVA OH XFMR 8' UTC # NEW POLE SER# 6= IN PLACE HANG 15 KVA OH XFMR (BA21L, 12 V60D ROW # UTC LINE ----------------- SER# ------------------ XFR OH SVCS STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS DALEY CURB © POLE PLI # 896 SET 45' CL 2 POLE (PW2045), 2' S POWER LINES 4 OLD POLE �o SET DEPTH = 6.5' OVERHANG] � or USE L GRVL BCKFLL, CMPCT IN 12 LFTS 3"--------r--- NEW POLE O� FRAME 30 FLAT TANG K 10 EGA TAP (6" LFTS ) FU 40 T ROW w XFR EXIST SG LINE 5 10 Z() XFR EXIST SEC SVCE FOR STILT I INSTL 10 STLT ARM (10504)FACING E FIRE XFR LUMINAIRE # SL-128624-B 3HYDRANT STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS " r� � -15— �� 0 NEW POLE r1 yz 0 OLD POLE Z 10' SPRAGUE CURB 10 Or NEW POLE,�--10' r� m> OLD POLE D m S NOHO MISH COUNTY p[oo PUBLIC Ui1L1iY OIsiRICi NO 1 LOCATION 305 10TH AVE S.EDMONDS AREA LYNNWOOD POLE NO MULTIPLE SE 1/4S 24 T 27 R 3 DATE 5/12/2020 ORDER 100047892 REASON FOR WORK REPLACE 29 BO POLES ENGINEER BEN ICE OPERATION 0030 IN EDMONDS DRAFTER UGND NO APPROVED SCALE NOTED DATE PRINTED DATE WORK COMPLETED FOREMAN SUBSTATION REFER TO SCHEMATICS CIRCUIT NO SCHEMATIC PHASE 1 2 33 FEES REO'D ❑ YES ■ NO PRIMARY OVERHEAD ENGINEER BEN ICE ❑ RESIDENTIAL PHONE 425 783 4355 ❑ COMMERCIAL LEO# O POLE PLI # 905 SET 50' CL 1 POLE (PW1050) 3' N SET DEPTH = 7' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 TANG ASSY (12F303) FRAME 10 EOA TAP (12V115) FOR E LATERAL, NORMAL OPEN FRAME 10 EGA TAP (12V115) FOR W LATERAL FU 15 T RMV 37 KVA OH XFMR UTC # SER# _ HANG 25 KVA OH XFMR (BA21N, 12F601) UTC # SER# XFR OH SVCS INSTL 14' STLT ARM (L0506) FACING W XFR LUMINAIRE # SL-101228-G RMV EXIST SEC UG RISER INSTL 3SEC RISER & 4 POS PED OU705) RUN 350 KCMIL TPX TO PED L= 50' STRIP, TOP & ABANDON 50' POLE TO COMMUNICATIONS OD POLE PLI # 898 SET 50' CL 1 POLE (PW1050), 4' NW SET DEPTH = 7' USE 5/8 GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 FLAT TANG W/ 10 EGA TAP (12F313) FU 40 T XFR EXIST SG XFR EXIST 15 KVA XFMR 15-389018 (12F601) INSTL 10'STLT ARM (10504) FACING E XFR LUMINAIRE 4 SL-129784-A RMV EXIST SEC UG RISER INSTL 3SEC RISER & 4 POS PED OU705) RUN 350 KCMIL TPX TO PED L- 50' STRIP, TOP & ABANDON 50' POLE TO COMMUNICATIONS EO POLE 116523 SET 35'CL 2 FG POLE (PFG2035) 5'W NEW OLD SET DEPTH = 5 POLE POLE PARKING USE GRVL BCKFLL, CMPCT IN 6" LFTS O LANE INSTL INVERTED COMBO GUY HOOK (R1306) XFR EXIST SG INSTL (D 12" AHR L = 8' W (AO102) 14' INSTL (1) UNINSULATED 3/8' DG (GO307) EXTEND EXIST OH SEC TPX RUN INSTL 3" SEC RISER & 4 POS PED OU705) INTERCEPT EXIST UG SEC TPX RUN RUN 350 KCMIL TPX TO PED L- 40' STRIP, TOP & ABANDON 30' POLE TO COMMUNICATIONS FO POLE PLI # 911 ROW NEW POLE SET 30'CL 2 POLE (PW2030), IN PLACE LINE IN PLACE SET DEPTH = 5' EDGE OF USE 5/8' GRVL BCKFLL, CMPCT IN 6" LFTS PAVEMENT INSTL INVERTED COMBO GUY HOOK (R1306) XFR EXIST SG 8' 7' INSTL (1) 12" AHR L = 8' W (AO102) INSTL (1) UNINSULATED 3A" DG (G0307) STRIP, TOP & ABANDON 30' POLE TO COMMUNICATIONS NEW POLE FOG OLD LINE POLE 0 10' I 0 ALLEY PAVEMENT DRAWING PUD RESPONSIBLE FOR POLE REMOVAL AND RESTORATION 1 OF 3 POE L PO E 10' 10' EDGE OF PAVEMENT © POLE 985 SET 45' CL 2 POLE (PW2045), 4' N 4' W SET DEPTH = 6.5' USE 5/8 GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 TANG ASSY (12F303) RMV 15 KVA OH XFMR UTC # SER# HANG 15 KVA OH XFMR (BA21L, 12F601) UTC # SER# ------------------- XFR OH SVCS STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS OH POLE PLI # 925 SET 50' CL 1 POLE (PW1050), 2' W SET DEPTH = 7' USE 5/8" GRVL BCKFLL, CMPCT IN 6" LFTS FRAME 30 FLAT TANG W/ 10 EGA TAP (12F313) FU 15 T XFR EXIST SG RMV 37 KVA OH XFMR UTC # SER# HANG 25 KVA OH XFMR (BA21N, 12F601) UTC # SER# XFR OH SVCS INSTL 10'STLT ARM (10504) FACING E XFR LUMINAIRE # SL-128573-B STRIP, TOP & ABANDON 50' POLE TO COMMUNICATIONS @f $ PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE $ LEU# SECONDARY UNDERGROUND BASIC FEE$_ @$�=3 UNDERGROUND PLAT BASIC FEES_ ENGINEERING 6 FT @ $ = f PLAT CONSTRUCTION d_FT@S = i STREET LIGHTING &FT@$ = f CROSSINGS C FT @ f = f WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONADARY 7<FT0 1f MISCELLANEOUS FEES VAULT f PERMIT f f t TOTAL DUE$ NESC VIOLATIONS ❑ NO ❑ YES (SEE NOTES) PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ CITY 11 EASEMENTS ❑ REQUIRED E# ■ NOT REQUIRED DATE SENT TO R/W DATE APPROVED FOREIGN CONTACTS ■ JPN- ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV ED POLE STENCILING FROM TO TAKE OFF POLE PRE—CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE (STREET LIGHTING ■ YES ❑ NO DATE PAID RECEIPT- GIS Ph JOINT USE NEW SVCE APPLICATION- I LOCATION MAP PAGE 454 1 I PUGET SOUND IssTH 524 sT sw WORK ZONE--- s c si EDMONDE 104 j 1 WOODWAY O Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED JP11 "10t 4zVV 09/02/202 Hono wzo-1 O O W20 4 W20-4 AHEAp O o N W20-7A ♦ W20-1 W20-7A ® T W O L < 100' 100' 100' sioP ■ � � � ~ 9TH AVE N ~ F F 1 ■ 100100' 100' W20-1 AxE°Ap W20-7A W20-4 ROAD W20-1 xoHH AHEAD O O pNE LANE W20-4 ANEAAN O W20-7A4 0 L o O O O O 0 0 O 0 } Oo• U �3 iz • �Z0 O f Z W Q 2 o O W20 74, 0 0 ONE LANE pno W20-4 A EAn 0 0 aono NHrc w20- A EAp FOR USE AT LOCATION A W20-4 W20-7A ♦ W20-1 O�100' 100' 100' EDMONDS ST ~ ■ W20-7A 0 0 W20-4 N o no�rn o ♦ W20-, FOR USE AT LOCATION E ENGINEERING DIVISION APPROVED AS NOTED Jill W411,04,e 09/02/2021 W20-1 roRx AHEAD O W ONE LANE W20-4 µEm Q 0 � U W20-7A 0 o � L 0 SHALL MAINTAIN 11' MIN. LANE WIDTH DALEY ST •• ®® 0 • o Y Y 1 ■ 100' 100' ,00' W20-, ♦ W20-7A N W 20-4 Nor� I PO D W20-1 MEHrc aAo 0 0 ONE LANE w20-4 µROAD W20-7A ■ o 11 O FOR USE AT LOCATION B r w W cr F— ,n ■ 0 W20-7A 0 0 Hoo W20-4 0 0 - ROAD xuHx W20-, AEp • I o . m 0� 0 O o 0 *W20-7A 0 _ ♦W20-4 o T o *W20-1 FOR USE AT LOCATIONS F, G, 1, J, L, M, N, 0, P, R, S, T, U, Y, Z, AA, AB, & AC H W20-1 W LLJ o Of W20-4 ♦ f V) (n O W20-7A 0 L �3 �Q 1 • W20-4 r - W20-7A W20-1 ) 1 ■ r iD I 1 1 1 •• ®© • STREET ~ STOP 100' 100' 100' o W20-7A 0 AN 0 ONE uNE W20-4 W20-1 HO W20-7A _ 0 0 W20-4 x W2o-1 AxEAo FOR USE AT LOCATIONS C, K, 0, & V 10 AH Ap ox HuxE xORrc Roap Ao 0 W20-1 W20-4 FOR USE AT LOCATION W Ln W Q 01 ROAD W20-1 YOHrc o W ONE LANE > W20-4 ROAD Q 0 � U W20-7A d o � • 1 SPRAGUE / BELL SHALL MAINTAIN 11' MIN. LANE WIDTH 100' 100' 100' W20-1 W20-7A N No W20-4 I rN W Q J 0 Z Y Q a N • noun Hono 0 - W20-1 xoRrc D N O O W20-4 W20-1 ID o Yo� *14 0 I •• ®® • ALDER ST ~ FOR USE AT LOCATIONS D & H � 1 1 W Q • • • 0 O FOR LOCATION AX ■ 0 0 W20-7A 0 o ♦ W20-4 O o_ W20-1 u 0 0 ♦ W1-4L 0 0 YOHrc NEAR W20-1