Loading...
ENG2021-0297 ROW PERMITRIGHT OF WAY EUC PERMIT City of • • • Edmonds98020 1 1 'ILJ7 www.cityofedmonds.gov Description: PUD-INSTALL PRIMARY UG RISER & PROVIDE SERVICE TO SHORT PLAT ISSUED: 09/14/2021 Address: 7901 240TH ST SW EDMONDS WA 98026 EXPIRES: 03/14/2022 Permit rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00452000400800 I I � i i NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER TWIN PIER LLC PO BOX 55545, SHORELINE WA 98155 (206)571-7777 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $110.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 09/14/2021 :»•>/F9:1H ]1 DATE Printed: Tuesday, September 14, 2021 10:04:22 AM 1 of 2 -KRWOF WAY EUC PERMIT City of • • • Edmonds•:• • 1 1 ' . -. •.v / 425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START X-2 ENGINEERING FINAL" E-7 RESTOR LIMITS E-7 TRAFFIC CTRL Printed: Tuesday, September 14, 2021 10:04:22 AM 2 of 2 100081067 ENG2021-0297 of EDif RIGHT OF WAY CONSTRUCTION PERMIT PLICA I N Complete and submit this Application in accordance with the Submittal Avc. 1 a9° Requirements outlined in Right-of-Way_permit Handout E63. If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications wM,)UW-d, SONOW03 30 AiI0 �ZOZ £0 5ny SECTIONA Q3AI303M Project Name lA ® -r` � ® A A o r r 0 \'&A Site Address or if no site address use Property Address at NW corner of project area: ` r�� !_ry Associated Permits: I BLD PIN ENG Name of Company Primary Name -� Agent Name Title Title Mobile Address Email City State Zip Secondary Name Phone Title Email Mobile City of Edmonds Business License No: Email State License No: 3kI> ®(3 S — -ILk xContractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE. ECDC 18.6o. 020 requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project m Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as weln ATraffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page i of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) b . ; Y\ �) RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF Alley 72 hours + LF x LF SF Parking 72 hours + LF x LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. i. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ❑ water ❑ sewer power ❑ storm ❑ gas Does the utilityowner have existingoverhead infrastructure in the area of work? T1. 2. Will anequipment be added underground or above ground (e. pedestals, vaults, etc.)? If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? . A 5. Does the work involve proposed additions to an aboveground utility stem? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the 6a. I Does your project involve How manv are yes: How manv are to be City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: How many? I I What is the height of the poles after? Describe the modification rebuild: �• 3 Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. t APPLICANT SIGNATURE: APPLICANT PRINTED NAME: $� APPLICANT TITLE: NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 1 112" WATER LINE W/ TRACER TAPE (TYP.) FNO 112" REBAR BENT OVER W I.O' CB RIM = 363.28' G Know what's below. Call before you dig. CB RIM = 357.39'-U"' E 1. E N.W. 12" = 355.91 ' S WCUTIIND AND REAK 1.E E 12" = 355.15' OF EX. ASPHALT RESTORATION AREA CLNN UTILITT CONFLICTNOTE.- CAUTION.• THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THISSHALL INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 POTHOLING ALL OF THE EXISTING UTILITIES AT LOCA7ONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNvFRpm P11P11/` 1A101011nrI-11 I— i I9,588 . I I I I I I r ,S, 078 SF �NETJ EY,CL AC&SS EAS ENT ARE 127' � r / I� Li \ �I 853 EXC1 ,EASE SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM RESTORATION LIMITS TO BE DETERMINED BY THE CITY INSPECTOR L EX. SI 00 a PER E 3d3S �I11O3b AvA s3nnIlf1 MriVOO-132J 'SQL&1Ah 6dit NO �-1 V dS3] i SI 2i="iNOO/2JDNMO SEP 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 6 ZOZ/K/60 WT n1 I nAI [1lJ n1 n /'1\I J JV ;oefoid pa}} med ay} buianp sm000 ao pasneo si;euj spiepuels Alio aad LANE CLOSURE ON A TWO-LANE LOW -VOLUME ROAD (ONE FLAGGER OPERATION) W20 1 Hof x �ttANE W20 400 W3-4 ,c W20 7A w LL1 af V) pe .fil crT-m:!� pui mm F im tLo 0 X W20-7A' x aa� W20-4 x � W20-1 W3-4 RESUB SEP 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 6ZOZ/V t /60 a�IlON SV 031AMJddV NOISIAICI ONNggNIONq SNOHOUISH COUNTY pIOEM LAYOUT LEGEND: IN PAD MOUNTED TRANSFORMER ® SUBMERSIBLE TRANSFORMER Q ABOVE GROUND J-BOX I] SUBMERSIBLE J-BOX I] SECONDARY VAULT PULLING VAULT PAD MOUNTED SWITCH CABINET ® SUBMERSIBLE SWITCH CABINET © SMALL SECONDARY PEDESTAL © LARGE SECONDARY PEDESTAL SL STREET LIGHT PEDESTAL PRIMARY UNDERGROUND CABLE -------•—•-#350 SECONDARY UNDERGROUND CABLE - - - - - - - - 4/0 SECONDARY UNDERGROUND CABLE ........................• 1/0 SECONDARY UNDERGROUND CABLE --—--,-STREET LIGHT CABLE SERVICE CONDUIT O POLE AND OVERHEAD LINE - - PROPERTY LINE —RIGHT-OF-WAY LINE U EXISTING UNDERGROUND CABLE EXISTING DUCT — — — — FUTURE DUCT ------- S------ 0 SANITARY SEWER/MANHOLE ------- D------ STORM DRAIN/CATCH BASIN ------- W----- -0WATER MAIN/METER Y FIRE HYDRANT (}) STREET LIGHT * UNDERGROUND LOCATOR MARKER SCHEMATIC LEGEND: • 10 TRANSFORMER 3 0 TRANSFORMER O SUBMERSIBLE TRANSFORMER ❑ 200 AMP J-BOX ■ 600 AMP J-BOX V FUSE PRIMARY UNDERGROUND CABLE ---------------ABANDONED PRIMARY UNDERGROUND CABLE OVHD EXISTING OVERHEAD i F DISCONNECT SWITCH, NORMALLY OPEN DISCONNECT SWITCH,NORMALLY CLOSED —i STANDOFF BRACKET • FEEDER LINE E3 PULL THRU BOX i FEED THRU BUSHING ON TRANSFORMER c FAULT INDICATOR U ADDITIONAL UGND TAPPED AT T/O POLE RESUB SEP 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TRANSFORMERS 7200-240/120V BY PUD OR PUD'S CONTRACTOR A-54787 25 KVA A-54788 25 KVA UTC UTC SER SER MAKE MAKE VAULTS BY PUD OR PUD'S CONTRACTOR A-54787 & A-54788 42" x 42" x 30" CONCRETE OPEN BOTTOM W/A 21" x 25" ACCESS HOLE A-54788 5- k-54787 5- 2 r crWf7KAATTr' -------- W--- ----- ;s--- PLI 228037 15-363084 CABLE ALL FOOTAGES APPROXIMATE BY PUD OR PUD'S CONTRACTOR FROM PLI 228037 TO A-54787 202' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN 2" PVC MAKE PO REEL FT MARK TO FROM A-54787 TO A-54786 210' OF (1) 1/0 AL 15KV CNCTRC NEUT JCKTD PRI IN 2" PVC MAKE PO REEL FT MARK TO 55' OF 350 KCMIL AL TPX SEC IN 3" PVC DUCT BY CUSTOMER OA 147' OF (D 2" PVC © 180' OF (1) 2" PVC I I r I ,IIIIII(III� LOT 4 ! 1 ... I I _ I :----------- W---------- W- i STREET SW -------------S----------- -'---0 _--�1----- G--------------- G- LAYOUT 1" = 30' N NORTH LOCATION 7901 240TH STREET SW.EDMONDS 98026 AREA LYNNWOOD POLE NO 228037 SEWS 31 T 27 R 4 DATE 7/29/21 ORDER 100081067 REASON FOR WORK PROVIDE 10 PRIMARY ENGINEER McALLISTER OPERATION 0060 UNDERGROUND SERVICE FOR DRAFTER McPHERSON UGNO NO 14424 4 LOT SHORT PLAT MPROVED SCALE NOTED 60 KW LD & DATE DATE WORK COMPLETED FOREMAN SUBSTATION RICHMOND PARK INSPECTOR CIRCUIT NO 12-5217 PHASE 2 1 DATE FEES REQ'D ■YES ONO ROAD CROSSINGS ONLY PRIMARY OVERHEAD ❑ RESIDENTIAL ❑ COMMERCIAL LED - APPV DATE DESCRIPTION REVISIONS APPV NO. DATE DESCRIPTION PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE s LEU- u sue•= S SECONDARY UNDERGROUND BASIC FEES o sue•- s WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONDARY FT C s_ = S AS -BUILT APPV NO. DATE DESCRIPTION MISCELLANEOUS FEES VAULT S PERMIT S CSLER s s s TOTAL DUES DATE PAID RECEIPT - ENGINEER MARY McALLISTER CUSTOMER BALWANT AULCK PHONE (425) 670-3216 PHONE (206) 571-7777 VICINITY MAP PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ■ EDMONDS EASEMENTS ■ REQUIRED Es ❑ NOT REOUIREO REQUEST NO. DATE APPROVED FOREIGN CONTACTS ❑ JPN- ❑ JOINT TRENCH ZIPLY & CATV ❑ JOINT BORE ZIPLY & CATV ■ WA POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE STREET LIGHTING ❑ YES ❑ NO M&R AS -BUILT GIS GIS OC .&R GIS Phi IJOINT USE LOCATION MAP PAGE 475. A3 TAGS VAULT: A-54787 & A-54788 Z CABLE: 111101 & 111102 05 .p G- 3l �o Machuga, Jen From: McAllister, Mary <MMMcAllister@SNOPUD.com> RESUB Sent: Wednesday, September 1, 2021 2:25 PM To: Edmonds Engineering Permits SEP 01 2021 Subject: RE: ENG2021-0297 7901 240TH ST SW ROW Permit Attachments: 20210901135922139.pdf CITY OF EDMONDS DEVELOPMENT Categories: Green category SERVICES DEPARTMENT Hi Jeff, I have scaled the drawing and noted the 5' clearance from the storm drain catch basin based on 1"=20' There will be 4 pot holes required I have noted the locations. I also have resubmitted a traffic plan showing the lane closure with appropriate signage. Please let me know if there is anything else you need, Thanks, Mary From: Edmonds Engineering Permits<EngineeringPermits@edmondswa.gov> Sent: Friday, August 27, 2021 1:24 PM To: Joint Use <JointUse@SNOPUD.com>; McAllister, Mary <MMMcAllister@SNOPUD.com> Subject: ENG2021-0297 7901 240TH ST SW ROW Permit CAUTION: THIS EMAIL IS FROM AN EXTERNAL SENDER. Do not click on links or open attachments if the sender is unknown or the email is suspect. Hi Mary, After reviewing your application to install a UG power service to 7901 240t" St SW I have few comments. There is a stormwater catch basin near the power pole where the drop is proposed. Please show on the plans an minimum 5' separation between the power conduit and the catch basin. If this can not be achieved please explain why. Since the new service will be bored the City requires that all utilities be potholed prior to boring. Please show on the plans the location of the potholing for all UG utilities that the boring will cross. There is no shoulder on this road so the traffic control plan that you provided will not work. Please provide a traffic control plan that shows a single lane closure with flaggers. Please show all appropriate signage. Please let me know if you have any questions. Thank You! City of Edmonds, Engineering Division Permitting EngineeringPermits@edmondswa.gov Jeff Whatmore, Engineering Technician (425) 771-0220 ext. 1339 City Hall Permit Center is now open Wednesdays, 10am-2pm. Appointments are encouraged. Remote and online permitting services are available Monday -Friday, including Zoom meetings. Please visit www.edmondswa.gov for up-to-date information on City services. For engineering permit inquiries, please email: engineeringpermits edmondswa.gov For all other inquiries please email: devserv.admin(a-)edmondswa.gov. Web Map: www.maps.edmondswa.gov