APPROVED BLD BLD2021-0728+Plumbing_Plan+5.26.2021_3.58.45_PM+2219084 (2)
PLUMBING FIXTURE SCHEDULE: FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND INSTALLATION VERIFY ROUGH -IN REQUIREMENTS. REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND Q INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. DCV HD SK TMV TIP WCO WHA SECURE PIPE HANGER TO STRUCTURE (TYP) THREADED STEEL ROD WITH NUT AND WASHER BOTH SIDES (TYP). CLEVIS HANGER, SHOWN FOR CLARITY. SIZE HANGER FOR COLD PIPE OUTSIDE DIAMETER PLUS INSULATION THICKNESS. DO NOT PENETRATE INSULATION WITH HANGER. PROVIDE A SECTION OF HIGH DENSITY INSULATION OR STYROFOAM BILLETS AT EACH HANGER OF COLD INSULATED PIPE. PROVIDE SHORT INSULATION SHIELD FOR LAPPING INSULATION JACKET OVER HIGH DENSITY INSULATION OR STYROFOAM BILLETS. MAINTAIN VAPOR BARRIER DUAL CHECK VALVE WITH ATMOSPHERIC PORT: WATTS # SD-3, MEETING ASSE 1022 AND NSF 18,316 STAINLESS STEEL BODY, 3/8" INLET AND OUTLET, ATMOSPHERIC PORT, AND WYE PATTERN STRAINER. PROVIDE 3/4" INDIRECT DRAIN FROM ATMOSPHERIC PORT AND DISCHARGE TO DRAIN WITH AIR GAP. HUB DRAIN: PROVIDE A P-TRAP BELOW FINISHED FLOOR AND STUB THE BELL END OF A CAST IRON PIPE 4" ABOVE FINISHED FLOOR. SIZE AS SHOWN ON FLOOR PLAN(S). SINK (ADA ACCESSIBLE): ELKAY # GECR2521R4, 25" X 21-1/4" X 5-3/8" DEEP, SINGLE COMPARTMENT, SELF -RIMMING, 20 GAUGE TYPE 304 STAINLESS STEEL, FIXTURE WITH 4 HOLE DRILLING FAUCET LEDGE. SET IN BED OF PUTTY. FAUCET- KOHLER "FORTE" FAUCET # K-10445, 8" SPREAD LEAD FREE FAUCET WITH REVERSIBLE QUARTER TURN WASHERLESS CERAMIC DISC VALVES, HIGH -ARC SWING SPOUT WITH 7-3/4" REACH, MATCHING FINISH SIDE SPRAY AND NIAGARA N3205N-PC LOW FLOW 0.5GPM NEEDLE SPRAY OUTLET. TRIM- MCGUIRE # LF2165CC LEAD FREE BRASS WHEEL HANDLE ANGLE STOP VALVES WITH RISERS AND ESCUTCHEONS, MCGUIRE # 151M CUP STRAINER WITH 1-1/2" 17 GAUGE TAILPIECE, MCGUIRE # B8912CF 1-1/2" 17 GAUGE CAST CHROME PLATED BRASS ADJUSTABLE P-TRAP WITH BRASS CLEANOUT AND ESCUTCHEON, PLUMBEREX "PRO -EXTREME" # X-4222 INSULATION KIT FOR WATER AND WASTE PIPES. THERMOSTATIC MIXING VALVE: LEONARD # 170-LF, SOLID LEAD FREE BRASS BODY, THERMOSTATIC WAX ELEMENT, CORROSION RESISTANT INTERNAL PARTS, AND INTEGRAL CHECKS, ASSE 1070 COMPLIANT, CAPABLE OF 2.3 GPM WITH A 10 PSI DIFFERENTIAL AND A MINIMUM FLOW RATE OF 0.25 GPM. SET TEMPERATURE TO 11 OF FOR DUEL TEMPERATURE LAVATORIES AND HAND SINKS, 10OF FOR SINGLE TEMPERATURE LAVATORIES AND HAND SINKS AND 120F FOR SINKS. MOUNT BELOW THE PLUMBING FIXTURE WHERE INDICATED ON PLAN(S). TRAP PRIMER: PRECISION PLUMBING PRODUCTS # PROI-500 "PRIME PRO", CORROSION RESISTANT BRASS BODY, "O" RING SEALS, 1/2" INLET AND OUTLET, AND INTEGRAL VACUUM BREAKER. INSTALL THE VALVE AT A MINIMUM OF 12" ABOVE FINISHED FLOOR. PROVIDE WITH DISTRIBUTION # DU-2 FOR TWO, # DU-3 FOR THREE, OR # DU-4 FOR FOUR DRAIN CONNECTIONS. WALL CLEANOUT: JAY R. SMITH # 4530S, CAST IRON CLEANOUT TEE, COUNTER SUNK PLUG, STAINLESS STEEL ROUND COVER AND SCREW, AND IRON PLUG WITH GASKET SEAL. REFER TO SPECIFICATIONS FOR INSTALLATION. WATER HAMMER ARRESTER: PRECISION PLUMBING PRODUCTS, HARD DRAWN COPPER BODY WITH WROUGHT COPPER FITTINGS, PISTON TYPE WITH LUBRICATED EPDM "0" RING SEALS, MEETING ASSE 1010 OR PDI WH-201. PROVIDE PDI SIZES "A" THROUGH "F" AS SHOWN ON PLANS. PROVIDE SIZE "A" UNLESS SHOWN OTHERWISE ON THE PLANS. INSULATED PIPE HANGER DETAIL NO SCALE REFER TO SPECIFICATIONS FOR INSULATION TYPES, INSULATION THICKNESSES, HANGER TYPES, HANGER ROD CONNECTIONS TO STRUCTURE AND HANGER SPACING. COLD WATER SUPPLY CONCEALED IN PARTITION WHERE SHOWN ON PLAN PROVIDE BACKFLOW PREVENTER WITH STRAINER IF/AS INDICATED ON FLOOR PLANS OR REQUIRED BY LOCAL AUTHORITIES PROVIDE DUAL OUTLET ANGLE STOP VALVE ON NEARBY SINK WITH ONE BRANCH TO SINK AND OTHER TO BEVERAGE DISPENSER CLEVIS HANGER, SHOWN FOR CLARITY. SIZE HANGER FOR HOT PIPE OUTSIDE DIAMETER. CUT INSULATION TO FIT AROUND HANGER. SEALEXPOSED INSULATION ENDS WITH JOINT SEALANT A FOUR FOOT )F SOFT TUBING, COILED KINKS, FROM I UNIT WATER FH ADAPTERS RED, SIZE PER ;TURER'S NDATIONS E DISPENSER TEA, SODA OR 3 SHOWN ON _E IN ;TOP BEHIND E DISPENSER PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. AIR GAP ON INTERNAL WATER FILL DEVICE PROVIDES BACKFLOW PREVENTION. VERIFY IF LOCAL AUTHORITIES REQUIRE SUPPLEMENTAL PROTECTION. BEVERAGE DISPENSER WATER NO SCALE SINK OR LAVATORY AS SHOWN ON PLANS 1/2" COLD WATER TO FAUCET(S) AS SHOWN ON PLANS 1/2" HOT WATER TO FAUCET(S) AS SHOWN ON PLANS AUTOMATIC VACUUM RELIEF VALVE PROVIDE 12"WIDE x 12"DEEP HEAT TRAP AT INLET AND OUTLET (TYPICAL) PROVIDE DIELECTRIC PIPE UNION AT TANK CONNECTION FOR CONNECTION OF DISSIMILAR METALS (TYPICAL) INSTALL ASME TEMPERATURE AND PRESSURE RELIEF VALVE FURNISHED WITH WATER HEATER ELECTRIC WATER HEATER, REFER TO SPECIFICATIONS AND SCHEDULE DRAIN VALVE BY WATER HEATER MANUFACTURER n 3/4" COLD WATER DOWN IN PARTITION VENT PIPE TRAP PRIMER SHUTOFF VALVE (TYPICAL) CHECK VALVE (TYPICAL) HARD COPPER DISCHARGE LINES TO END OVER FUNNEL DRAIN. AIM DOWN WITH 6" AIR GAP 2" WASTE PIPE 2" CAST IRON P-TRAP WITH 2"x3" INCREASER MOUNT ABOVE FLOOR 2" WASTE PIPE REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. VERIFY ALL CONNECTION SIZES AND LOCATIONS PER MANUFACTURERS REQUIREMENTS. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR PLANS FOR PIPE SIZES. PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. POWER WIRING AND DISCONNECT SWITCH ARE SPECIFIED BY ELECTRICAL. 2 POINT -OF -USE WATER HEATER NO SCALE AUTOMATIC TRAP PRIMER VALVE WITH INTEGRAL AIR GAP. INSTALL TRAP PRIMER MINIMUM 12" ABOVE FLOOR FOR EVERY 20' OF DISCHARGE PIPE. IF TRAP PRIMER IS INSTALLED IN PARTITION, PROVIDE ACCESS DOOR PER SPECIFICATIONS. PROVIDE DISTRIBUTION UNIT(S) WHERE MORE THAN ONE TRAP IS SERVED BY ONE TRAP PRIMER VALVE. PROVIDE FLOOR DRAIN BODY OR P-TRAP WITH THREADED TRAP PRIMER CONNECTION. PROVIDE SWEAT TO THREADED ADAPTER. BRAZE JOINT BELOW FLOOR SLAB ON GRADE. CONNECT 1/2" PIPE (WITHOUT SHUT-OFF VALVE IN BRANCH) TO TRAP PRIMER INLINE PRIOR TO FIXTURE SERVED (DO NOT INSTALL VALVE ON A BYPASS). INSTALL TRAP PRIMER LINE(S) DOWNSTREAM OF TRAP PRIMER OR DISTRIBUTION UNIT USING 1/2" SOFT COPPER TUBING. INSTALL WITHOUT KINKS, AND SLOPE CONTINUOUSLY TOWARDS FLOOR DRAIN. CONCEAL PIPE(S) IN PARTITION OR CHASE IN FINISHED AREAS. TRAP PRIMER AND PIPES MAY BE INSTALLED EXPOSED IN UNFINISHED, NON-PUBLIC AREAS. IF PIPE IS BELOW FLOOR SLAB ON GRADE, PROVIDE 1/2" ELASTOMERIC INSULATION FROM PRIMER CONNECTION TO 1" ABOVE FLOOR SLAB. PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDULE FOR MORE INFORMATION. INSTALL TRAP PRIMER VALVE AND DISTRIBUTION UNIT PER MANUFACTURER'S RECOMMENDATIONS. TRAP PRIMER IN/OUT WALL NO SCALE PLUMBING SYMBOLS THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED. V2.01 STANDARD MOUNTING HEIGHTS PIPING SYMBOLS PIPING LINETYPES REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. ® 0 FLOOR SINK (FS), SIZE & TYPE ---CW--- DOMESTIC COLD WATER (CW) UNO, INSTALL PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOW WITH FINAL APPROVAL BY THE ARCHITECT. EM ® FLOOR DRAIN (FD), SIZE & TYPE ---SCW--- SOFTENED COLD WATER (SCW) LAVATORY OR SINK (0) ROOF DRAIN (RD), SIZE & TYPE ----HW---- DOMESTIC HOT WATER (HW) STANDARD HEIGHT 31" FLOOR TO RIM ADA ACCESSIBLE 34" FLOOR TO RIM IFI BALL VALVE -----HWR----- DOMESTIC HOT WATER RECIRC. (HWR) CHILD HEIGHT 24" FLOOR TO RIM CONTROL VALVE 140° 140° DOMESTIC HOT WATER (140°) URINAL STANDARD HEIGHT 24" FLOOR TO RIM 4 SHUTOFF VALVE T TRAP PRIMER LINE (T) ADA ACCESSIBLE 17" FLOOR TO RIM CHILD HEIGHT 14" FLOOR TO RIM CHECK VALVE S SOIL PIPING - ABOVE FLOOR (S) WATER CLOSET vt BALANCING VALVE WITH PRESSURE PORTS -S - SOIL PIPING - BELOW FLOOR (S) STANDARD HEIGHT 15" FLOOR TO RIM ADA ACCESSIBLE 17" TO 19" FLOOR TO TOP OF SEAT f WATER METER W WASTE PIPING - ABOVE FLOOR (W) CHILD HEIGHT 10" FLOOR TO RIM STRAINER __W__ WASTE PIPING - BELOW FLOOR (W) WATER COOLER OR DRINKING FOUNTAIN STANDARD HEIGHT 41" FLOOR TO SPOUT STRAINER WITH BLOWOFF GW GREASE WASTE - ABOVE FLOOR (GW) ADA ACCESSIBLE 36" FLOOR TO SPOUT CHILD HEIGHT 30" FLOOR TO SPOUT RELIEF/SAFETY VALVE - - -GW- - - GREASE WASTE - BELOW FLOOR (GW) SHOWER VALVES 4 SOLENOID VALVE CGWV COMBINATION GREASE WASTE AND VENT (CGWV) STANDARD HEIGHT - MEN 48" FLOOR TO CENTERLINE Y STANDARD HEIGHT - WOMEN 42" FLOOR TO CENTERLINE PRESSURE REDUCING VALVE -CWV- COMBINATION WASTE AND VENT (CWV) ADA ACCESSIBLE 38" MIN TO 48" MAX FLOOR TO CENTERLINE �AGAS PRESSURE REGULATOR ST STORM DRAIN - ABOVE FLOOR (ST) SHOWER HEADS MEN 6'-6" FLOOR TO CENTERLINE THERMOSTATIC MIXING VALVE - - -ST- - - STORM DRAIN - BELOW FLOOR (ST) WOMEN 6'-0" FLOOR TO CENTERLINE PA PIPE ANCHOR OST OVERFLOW STORM DRAIN - ABOVE FLOOR (OST) TUB VALVES EJ STANDARD HEIGHT 32" FLOOR TO CENTERLINE EXPANSION JOINT - -VBG- - VENT BELOW GRADE (VBG) ADA ACCESSIBLE CENTER BETWEEN GRAB BAR AND TUB RIM BACKFLOW PREVENTER - -VBF- - VENT BELOW FLOOR (VBF) CLINIC SERVICE SINKS 30" FLOOR TO RIM PRESSURE GAUGE ID INDIRECT DRAIN (ID) SURGEON'S SCRUB -UP SINKS 35" FLOOR TO FRONT RIM THERMOMETER CDH CONDENSATE DRAIN -HIGH EFFICIENCY RTU (CDH) ICE MAKER OUTLET BOXES 24" FLOOR TO CENTER OF BOX 10 UNION CD CONDENSATE DRAIN (CD) WASHING MACHINE OUTLET BOXES 42" FLOOR TO RIM FLANGE CONNECTION -ACD- AUXILIARY CONDENSATE DRAIN (ACD) JANITOR'S SINK FAUCET FITTINGS 42" FLOOR TO CENTERLINE HOSE BIBB (HB) SPD SUMP OR SEWAGE PUMP DISCHARGE (SPD) HOSE BIBBS 36" AFF TO CENTERLINE IF NONFREEZE WALL HYDRANT (NW) G NATURAL GAS (G) NON FREEZE WALL HYDRANTS 18" AFG TO CENTERLINE n n MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE T PRESSURE / VACUUM SWITCH - - -G- - - NATURAL GAS ON ROOF (G) MPG MEDIUM PRESSURE NATURAL GAS (MPG) USE THE DEFAULT MOUNTING HEIGHTS SHOWN ABOVE UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS OR ELSEWHERE. MOUNTING HEIGHTS LISTED ARE ABOVE FINISHED FLOOR (AFF) OR ABOVE FINISHED GRADE (AFG). ALL DEVICES SHALL BE INSTALLED IN CLEANOUT - -MPG- - MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) COMPLIANCE WITH CURRENT ADA AND LOCAL REQUIREMENTS. CAP NPW NON POTABLE WATER (NPW) ANNOTATION 0.1 WALL CLEANOUT (WCO) LPG LIQUIFIED PETROLEUM GAS (LPG) OPLUMBING PLAN NOTE CALLOUTO FLOOR CLEANOUT (FCO) WS WATER SERVICE (WS) �O EXTERIOR CLEANOUT (ECO) FP FIRE PROTECTION (FP) PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND 1O INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT ELBOW UP PD CONDENSATE PUMP DISCHARGE (PD) SCHEDULES � ELBOW DOWN V VENT PIPING (V) EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR TEE UP INSTALLED) TEE DOWN CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR PROVIDED ELBOW UP WITH SHUT-OFF VALVE (SOV) 1 UNO) � ELBOW DOWN WITH SHUT-OFF VALVE (SOV) CONNECTION POINT OF NEW WORK TO EXISTING TEE UP WITH SHUT-OFF VALVE (SOV) TEE DOWN WITH SHUT-OFF VALVE (SOV) 1 DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER * 4 P1 LOWER NUMBER INDICATES SHEET NUMBER WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D, & E) 1 SECTION CUT DESIGNATION RECIRCULATION PUMP P1 00 P-TRAP GAS COCK TRAP PRIMER ABBREVIATIONS ADA AMERICANS WITH MAU MAKE-UP AIR UNIT DISABILITIES ACT MAX MAXIMUM AFF ABOVE FINISHED FLOOR MBH 1000 BTU PER HOUR TRAP PRIMER WITH DISTRIBUTION UNIT AFG ABOVE FINISHED GRADE MH MANHOLE AHU AIR HANDLING UNIT MIN MINIMUM AP ACCESS PANEL N/C NORMALLY CLOSED BAS BUILDING AUTOMATION SYSTEM N/O NORMALLY OPEN BFF BELOW FINISHED FLOOR NIC NOT IN CONTRACT BFG BELOW FINISHED GRADE ORD OVERFLOW ROOF DRAIN BOP BOTTOM OF PIPE PDI PLUMBING DRAINAGE INSTITUTE BOS BOTTOM OF STRUCTURE PH/O PHASE BTU BRITISH THERMAL UNIT PRV PRESSURE REDUCING VALVE CID CONDENSATE PUMP PVC POLYVINYL CHLORIDE CPVC CHLORINATED POLYVINYL RCP REINFORCED CONCRETE PIPE CHLORIDE RD ROOF DRAIN Cu COPPER RPM REVOLUTIONS PER MINUTE DI DUCTILE IRON RTU ROOFTOP UNIT DIN DOWN SF SQUARE FEET DFU DRAINAGE FIXTURE UNIT SP SUMP PUMP DS DOWNSPOUT SS STAINLESS STEEL, SANITARY (E) EXISTING SEWER, SOIL STACK EMS ENERGY MANAGEMENT SYSTEM TDH TOTAL DYNAMIC HEAD ETR EXISTING TO REMAIN TFA TO FLOOR ABOVE EWC ELECTRIC WATER COOLER TFB TO FLOOR BELOW LINETYPE LEGEND FD FLOOR DRAIN TYP TYPICAL FFA FROM FLOOR ABOVE UL UNDERWRITERS FFB FROM FLOOR BELOW LABORATORIES, INC. THROUGHOUT THE DRAWINGS DIFFERENT LINE -TYPES ARE USED IN COMBINATION WITH FF FINISHED FLOOR LINO UNLESS NOTED OTHERWISE THE SYMBOLS TO INDICATE THE STATUS OF ITEMS AS EXISTING, TO BE DEMOLISHED, TO FL FLOW LINE UPS UNINTERRUPTIBLE POWER BE INCLUDED AS PART OF NEW WORK AND/OR ITEMS WHICH ARE ANTICIPATED TO BE FLA FULL LOAD AMPS SUPPLY PROVIDED IN THE FUTURE. THE STATUS OF ITEMS USING THESE LINETYPES ARE RELATIVE FLR FLOOR VCP VITRIFIED CLAY PIPE TO THE VIEW IN WHICH THEY APPEAR. PHASING SHOWN IN DRAWINGS IS NOT INTENDED GPM GALLONS PER MINUTE VFD VARIABLE FREQUENCY DRIVE TO FULLY DESCRIBE ALL NECESSARY CONSTRUCTION PHASING, WHICH IS DETERMINED BY HD HEAD, HUB DRAIN VS VENT STACK THE CONTRACTOR AS PART OF THEIR RESPONSIBILITIES. ANY SUCH PHASES DESCRIBED HZ HERTZ VTR VENT THROUGH ROOF IN THE CONSTRUCTION DOCUMENTS ARE GENERAL AND ONLY INTENDED TO INDICATE A IE INVERT ELEVATION W/ WITH BROAD ORDER FOR THE SAKE OF DESCRIBING THE PROJECT. THE FOLLOWING LINETYPES IN WC INCHES OF WATER COLUMN W/O WITHOUT MAY BE USED ON ANY DEVICE, EQUIPMENT, NOTE, LINE, SHAPE, ETC. JB JUNCTION BOX WC WATER COLUMN J-BOX JUNCTION BOX WS WASTE STACK EXISTING NEW KW KILOWATT WSFU WATER SUPPLY FIXTURE UNIT WVS WASTE VENT STACK DEMOLISH ------------------------ FUTURE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE FIXTURE BRANCH CONNECTION SCHEDULE FIXTURE COLD WATER HOT WATER WASTE VENT HUB DRAIN -- -- 2" 2" SINK 1/2" 1/2" 2" 2" NOTE: PIPE SIZES SHOWN ARE MINIMUM. ELECTRIC STORAGE WATER HEATER SCHEDULE MARK MANUFACTURER/ MODEL# AREA SERVED TANK SIZE (GALLONS) ELECTRICAL DATA RECOVERY (GPH) NOTES VOLTS PHASE KW EWH CHRONOMITECMT-2.5 BREAKROOMSINK 2.5 120 1 1.44 9 A NOTES: A 68° TEMPERATURE RISE WITH 110°F OPERATING TEMPERATURE. APPROVED PLANS MUST BE GENERAL NOTES 1. PROVIDE A CONSTRUCTION RECORD SET OF "AS -BUILT" DOCUMENTS TO THE ARCHITECT REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OR EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS, REFER TO SPECIFICATIONS. 2. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 3. PROVIDE TO THE ARCHITECT A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS, REFER TO SPECIFICATIONS. 4. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING. 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 6. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES. 7. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING. 8. INSTALL CONCEALED PIPING TIGHT TO THE STRUCTURE AND AS HIGH AS POSSIBLE. INSTALL EXPOSED PIPING TIGHT TO THE STRUCTURE, WALL OR CEILING AND AS HIGH AS POSSIBLE. COORDINATE WITH OTHER TRADES TO AVOID CONFLICTS. 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. 10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 11. INSTALL NO PLASTIC PIPE IN THE CEILING RETURN AIR PLENUM. 12. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. 13. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED. 14. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE OWNER. 15. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. 16. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT INSTALL PIPING OVER ELECTRICAL PANELS. 17. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST INHIBITOR PAINT. PAINT AND COLOR SHALL BE COORDINATED WITH THE ARCHITECT AND / OR OWNER. 18. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10, MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. 19. PROVIDE TRANSITION ADAPTER COUPLINGS FOR CONNECTION OF PVC DWV TO CAST IRON SANITARY, WASTE AND VENT PIPE AT SLAB ON GRADE. SEE DIVISION 22 SPECIFICATION SECTION "SANITARY DRAINAGE AND VENT PIPING AND 20. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 21. PROVIDE VERTICAL LIFT SPRING LOADED CHECK VALVES IN HOT AND COLD WATER SUPPLIES FOR MOP SINK FAUCETS DOWNSTREAM OF SHUTOFF VALVES. 22. VERIFY EXISTING EQUIPMENT TO REMAIN, INCLUDING ACCESSORIES, IS NOT DAMAGED AND IS IN GOOD WORKING ORDER. REPORT ANY DEFICIENCIES TO THE ARCHITECT. 23. PROVIDE SIZE AND LENGTH OF HOT WATER FIXTURE SUPPLY PIPE FROM CIRCULATED HOT WATER BRANCH OR MAIN TO TERMINATION OF HOT WATER FIXTURE SUPPLY PIPE AT EACH FIXTURE PER 2015 INTERNATIONAL ENERGY CONSERVATION CODE, TABLE C404.5.1. FOR''/2" HOT WATER FIXTURE SUPPLY PIPE SIZE TO INDIVIDUAL LAVATORIES, PROVIDE MAXIMUM LENGTH OF TWO FEET. FOR'/2" HOT WATER FIXTURE SUPPLY PIPE SIZE TO INDIVIDUAL SINKS, PROVIDE MAXIMUM LENGTH OF 43 FEET. FOR 3/4" HOT WATER FIXTURE SUPPLY PIPE SIZE TO INDIVIDUAL SINKS, PROVIDE MAXIMUM LENGTH OF 21 FEET. City Of Edmonds Building Department Work PLUMBING --------------------------------------------------------------------- Address 306 MAIN ST ------------------------------------------------ -------------------------------------------------------------------- Owner BANK OF AMERICA Approved Date 6 - 9 - 2 0 2 1 Building Official Eri& C4wfer Permit Number BLD2021-0728 Bankof America'�I RRP RENOVATION 306 MAIN ST. EDMONDS, WA 98020 SERIAL NUM./MANH. ID: WA4-115 NRSP VERSION: 2.0 BULLETIN: 04-2019 Gensler 1200 Sixth Avenue Suite 500 Seattle, WA 98101 United States Tel 206.654.2100 Fax 206.654.2121 RECEIVED May 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913.742.5000 FAX 913.742.5001 WWW.HENDERSONENGINEERS.COM 1950004733 WA. CORPORATE NUMBER: 1754 06/30/20 0 Date Description 04/28/2020 ISSUE FOR PERMIT Seal I Signature �� M. 56737 Project Name Apr 28 2020 EDMONDS RRP Project Number 1950004733 Description PLUMBING GENERAL NOTES, LEGEND AND SCHEDULES Scale AS NOTED ON JOB SITE P00000 © 2015 Gensler O SHEET NOTES ROOM 113 i r ❑ O O ❑ ❑0 O PLUMBING WASTE AND VENT PLAN SCALE: 1 /4"=1'-0" TO BASEMENT WASTE AND VENT RISER DIAGRAM SCALE: NO SCALE 1. CONNECT NEW SANITARY PIPING TO EXISTING SANITARY PIPING OF EQUAL OR LARGER SIZE BELOW GRADE ON BASEMENT LEVEL. FIELD VERIFY EXISTING PIPE SIZE LOCATION AND INVERT ELEVATION PRIOR TO CONSTRUCTION. 2. VERIFY VTR LOCATION ON ROOF. VTR SHALL BEAT LEAST 10' AWAY FROM ANY OUTSIDE AIR INTAKE. 3. HATCHED AREA NOT APART OF PLUMBING WORK SCOPE. Bank of America'�I RRP RENOVATION 306 MAIN ST. EDMONDS, WA 98020 SERIAL NUM./MANH. ID: WA4-115 NRSP VERSION: 2.0 BULLETIN: 04-2019 Gensler 1200 Sixth Avenue Tel 206.654.2100 Suite 500 Fax 206.654.2121 Seattle, WA 98101 United States RECEIVED May 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913.742.5000 FAX 913.742.5001 WWW.HENDERSONENGINEERS.COM 1950004733 WA. CORPORATE NUMBER: 1754 06/30/20 A Date Description 04/28/2020 ISSUE FOR PERMIT Seal / Signature _�'� M. 56737, Project Name Apr 28 2020 EDMONDS RRP Project Number 1950004733 Description PLUMBING WASTE AND VENT PLAN Scale ry w J O M Z H N P0101 © 2015 Gensler (D SHEET NOTES ROOM 113 r ❑ O O ❑ i i l PLUMBING i ►'� �. i 3/4" C 1 /2"CW SK WHA J 1. 3/4"CW SUPPLY DOWN TO BASEMENT LEVEL. CONNECT NEW 3/4"CW SUPPLY TO EXISTING CW SUPPLY OF EQUAL OR LARGER SIZE LOCATED ABOVE FINISHED CEILING OR AS CLOSE TO FLOOR DECK AS NECESSARY. PROVIDE ACCESSIBLE SHUT-OFF VALVE DOWNSTREAM THE POINT OF CONNECTION. FIELD VERIFY EXISTING SUPPLY LOCATION AND SIZE PRIOR TO CONSTRUCTION. 2. ROUTE 1/2" CW PIPING IN WALL AND STUB BELOW COUNTERTOP WITH SHUT-OFF VALVE FOR CONNECTION TO QUENCH WATER DISPENSER STATION BY OTHERS. 3. HATCHED AREA NOT APART OF PLUMBING WORK SCOPE. 4. INSTALL ELECTRIC WATER HEATER AND ACCESSORIES IN A MANNER THAT IT WILL NOT OBSTRUCT ADA CLEARANCES. W QUENCH WATER DISPENSER BY OTHERS DCV U 3/4°CW U WH TO BASEMENT TIP LEVEL Bank of America'�I RRP RENOVATION 306 MAIN ST. EDMONDS, WA 98020 SERIAL NUM./MANH. ID: WA4-115 NRSP VERSION: 2.0 BULLETIN: 04-2019 Gensler 1200 Sixth Avenue Suite 500 Seattle, WA 98101 United States Tel 206.654.2100 Fax 206.654.2121 RECEIVED May 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913.742.5000 FAX 913.742.5001 WWW.HENDERSONENGINEERS.COM 1950004733 WA. CORPORATE NUMBER: 1754 06/30/20 Date Description 04/28/2020 ISSUE FOR PERMIT Seal / Signature _ � M. 1 56737, Project Name Apr 28 2020 EDMONDS RRP Project Number 1950004733 Description PLUMBING WATER AND GAS PLAN Scale AS NOTED ry w 0 J O M Z F- U) 2 WATER RISER DIAGRAM SCALE: NO SCALE P0101 © 2015 Gensler