APPROVED BLD RESUB1 BLD2021-0647+Architectural_Plan+6.3.2021_10.21.48_PM+2231749
DR. SCOTT BABIN, DDS DENTAL OFFICE TENANT IMPROVEMENT EDMONDS, WASHINGTON VICINITY: LEGAL DESCRIPTION: WILLOWDALE GARDENS DIV 1 BLK 000 D-01 — LOT 17 LESS N 250FT PHASE OF WORK: EXIT PHASE ♦�♦ � WALL TYPES: �� __J � EXISTING WALLS TO REMAIN O NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS ®24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. � r I I � II �� � 1 0 � r oXn -_ �-� -� � � �' 0 � Woo 0 �- � 1 1 �'� � I � I EXIT EGRESS = 75'-0" � r------L�--�---�-1----------------------� U � 0 � 0 � 0 0 1 � O O ��\ . 0 2' 4' 8' SCALE: RELEASE OF DRAWINGS: I HAVE REVIEWED ALL OF THE DRAWINGS PREPARED BY THE ARCHITECT/DESIGNER, UNDERSTAND THEM FULLY, AND AUTHORIZE THEIR RELEASE FOR PERMITTING, CONTRACTOR BIDDING AND CONSTRUCTION. I UNDERSTAND THAT ANY CHANGES AND/OR ADDITIONS TO THE PLANS COULD RESULT IN CHANGE ORDERS AND/OR ADDITIONAL COST BEYOND THE SCOPE OF THESE DRAWINGS. CLIENT: ---------------------------------------- APPLICABLE CODES: (CODES WITH STATE AND LOCAL AMENDMENTS): • 2018 INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL EXISTING BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL FIRE CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL MECHANICAL CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 WASHINGTON STATE ENERGY CODE — COMMERCIAL PROVISIONS • 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES • 2020 NATIONAL ELECTRICAL CODE SECTION (NEC) AND 2020 WASHINGTON CITIES ELECTRICAL CODE SECTIONS AS AMENDED BY THE CITY OF EDMONDS • 2018 UNIFORM PLUMBING CODE (UPC) AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS GENERAL CONSTRUCTION NOTES: 1. A SEPARATE PERMIT IS REQUIRED FOR THE MECHANICAL, ELECTRICAL, AND PLUMBING OF THIS TENANT IMPROVEMENT. FIRE PROTECTION (IF APPLICABLE) IS SEPARATE PERMIT. 2. ALL WALL PARTITIONS TO BE DEMOLISHED ARE NON —BEARING. 3. PROVIDE ONE 2A10BC PORTABLE FIRE EXTINGUISHER PER NFPA-10 FOR EVERY 3,000 S.F. OF AREA AND NOT TO EXCEED 75 FT. OF TRAVEL DISTANCE BETWEEN EXTINGUISHERS. VERIFY LOCATION WITH FIRE MARSHAL. 4. SUBCONTRACTOR IS TO BRING TO ATTENTION TO THE CONTRACTOR ANY DISCREPANCIES ON DRAWINGS DURING BID PROCESS. 5. CONTRACTOR TO CONDUCT A DENTAL EQUIPMENT LAYOUT MEETING WITH DENTAL SUPPLIER AND SUBCONTRACTORS. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE CONSTRUCTION TYPE �B OCCUPANCY GROUP B OCCUPANT LOAD 11 12' Separate permit required for: Mechanical Plumbing Vacuum/Air Approved by Fire 06/16/2021 AFM fC��tt�I�el� - MECHANICAL HVAC, ELECTRICAL AND PLUMBING TO BE MODIFIED UNDER SEPARATE PERMIT. 3RD PARTY VERIFICATION REQUIRED). - THERE ARE NO MED GASSES IN THIS FACILITY. _ his would include oxegen - NO CHANGE OF OCCUPANCY USE. - NO STRUCTURAL MODIFICATIONS TO BUILDING EXTERIOR. SHEET INDEX: ID-1 COVER SHEET /SITE PLAN /CODE ANALYSIS PLAN /PROJECT NOTES ID-2 PARTITION FLOOR PLAN ID-3 REFLECTED CEILING PLAN ID-6 DETAILS PROJECT DESCRIPTION: DENTAL OFFICE TENANT IMPROVEMENT: OCCUPIED REMODEL OF EXISTING 1,547 SQ. FT SPACE IN EXISTING 1—STORY OFFICE BUILDING. NO STRUCTURAL CHANGES, NO CHANGE OF USE. INTERIOR WALLS, DOORS, CABINETS, REPLACEMENT OF CEILING TILE. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHTING FIXTURES PER PLANS. ESTIMATED CONSTRUCTION VALUE: �65,000.00. PROJECT ADDRESS: 7631 212TH ST SW, SUITE 109—C EDMONDS, WA 98026 CONTACTS: BUILDING OWNER: OASIS, INC. 1516 129TH AVE NE WOODINVILLE, WA 98072 CONTACT: SAM ABOULHOSON PHONE: (425) 486-0566 EMAIL: SAMIR_ABOULHOSON�YAHOO.COM DR. SCOTT BABIN, DDS 7631 212TH ST SW, SUITE 109—C EDMONDS, WA 98026 PHONE: (206) 972-4962 EMAIL: INFO�SCOTTBABINDDS.COM INTERIOR DESIGNER: DAVID COMPANY CONTACT: KELLY NEWBOLD PHONE: (206) 999-3457 GENERAL CONTRACTOR: DAVID COMPANY CONTACT: KELLY NEWBOLD PHONE: (206) 999-3457 DENTAL EQUIPMENT SUPPLIER: TO BE DETERMINED ADMINISTRATIVE: ZONING: BLDG. ID: 1 OF 1; TAX PARCEL NO.: 00614300001701 ZONING JURISDICTION: CITY OF EDMONDS ZONING CLASSIFICATION: BN (NEIGHBORHOOD BUSINESS) PARKING SPACES: NO CHANGE OCCUPANCY USE: NO CHANGE BUILDING: NUMBER OF STORIES: 1 BUILDING TYPE OF CONSTRUCTION: V—B, (NON—SPRINKLERED/NO FIRE ALARM) TENANT SPACE: PROJECT AREA FOR THIS TENANT IMPROVEMENT: 1,547 S.F. OCCUPANCY GROUP: GROUP B (DENTAL OFFICE) OCCUPANT LOAD: 1,547 S.F / 150 S.F. = 10.31 = 11 OCCUPANTS (ONLY 1 EXIT REQUIRED) MAX. NUMBER OF EMPLOYEES/MANAGERS WORKING AT SAME TIME: 5 Structural Alterations not included in this permit City Of Edmonds Building Department Work T/I Address 7631 212TH ST SW #109C Owner DR SCOTT BABIN DDS Approved Date 6 —10 — 2 0 21 Building Official Er%li � Permit Number BLD2021-0647 David Company CLIENT /PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: PERMIT SET COVER SHEET ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designerand may not be reproduced in part or whole without prior written permission. RESUB Jun 04 2021 CITY OF EDMONDS Pro'ect No.: 14-72 DEVELOPMENT SERVICES DEPARTMENT Date: 5/22/2021 DATE: ____/____/ PHASE OF WORK: PHASE I WALL TYPES: I L________J EXISTING WALLS TO BE DEMOLISHED � EXISTING WALLS TO REMAIN I NEW INTERIOR WALLS -- 5/8" G.W.B. � I OVER 3-5/8" METAL STUDS ©24" O.C.; PACKED WITH SOUND GATT � I INSULATION; SMOOTH FINISH G.W.B. � W/ MTL. CORNERS, U.N.O. I Q» SEE ACCESSIBILITY - I CODE NOTE #1 `° � I -,, / � (E) � � � (E) — I' (E) LAB I � I RESTROOM / I STERIL DEMO COUNTER AND 102 I 101 / 110 BASE CABINETS. CUT COUNTERTOP AND is o �' � �'—r� BACKSPLASH BACK W�� I i � 30". PLAM EDGE OF N _� _� ��_ COUNTERTOP AND — — — BACKSPLASH. PLAM �'—�� I I BASE CABINET. (� �� �; i i I I � � I CABINET PER PLAM _�_�___�'_� i I 3'—s" 2r-2" I� I SCHEDULE. i i P� � � � -J ====t= ='--- � , ^I „ , „ 3 —11 3 —10 28'-1" 13'-7" 12'-10" 14'-6" SAVE EXISTING 4—PLEX OUTLET ` I I �� DEMO WIRE PLUG MOLD �� �I r� I I -- -- --- I I II h EXISTING WAITING —— i i II i i i RECEPTION 113 I I II ,' I i CASEWORK I I�-- � i I RELOCATED N i i �—� i i PER PLAN RECEPTION i i � � i i TV ID-7 112 I I ( r=�� I I I I —_ II • III I r� __� L_� __ �I L=_ =JI I � /TT� _ � a i i i i ``;�I; �I --- --- 1 �i ST L � 111 30"H COU TER ��— � I�� ID-7 i � -- 2 4'-9" 3'-0 � r� REF'R. I ��� �____ - -}l ��r — � 20x17 g�/ I I � __� I � � --------- - --- -----� �, C ----- — -- -----� ti , �--i OFFICE CAL -----I II � I 108 • � I I ID-7 109 i'I i � I ----- i i I 4 --s � I I I I � — DEMO (�) �ARPET � � ----�c WALZ i BpSE r ----J �� ----------1—J------J � , » I 3'-10" L-. 3'—s" 1'—s" 1'-9" 3'-0" i i 11 I � � I (D r—-------- --- — r �� —___� I �——,—T---- --- ISI � _-----L_—¢T— ,I —/ —�-- � \ o 3'-10" L---- �'�--� 5'-10» � �3�, I � l LL�JJI E I HYG � i HYG 1 1os -_1_ J 107 ��r Door hardware to — comply with IBC 1010.1.9.4. GENERAL PLAN NOTES: 1. ALL DIMENSIONS FROM FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE (U.N.O.). CONTRACTOR TO VERIFY DIMENSIONS AND BRING TO DESIGNER'S ATTENTION ANY CONFLICTS BETWEEN PROPOSED LAYOUT AND ACTUAL FIELD CONDITIONS BEFORE FRAMING OR PLUMBING WORK BEGINS. 2. IN —WALL BRACKETS FOR COUNTERTOPS TO BE SUPPLIED AND LOCATED BY CABINET MAKER, INSTALLED BY GC. 0 3. PROVIDE U—BREAK SHAPED ALUMINUM END WALL CAPS WHERE WALLS I MEET STOREFRONT WINDOWS W/ 1" LEG, COLOR TO MATCH EXISTING 00 STOREFRONT FRAMES. ,� 4. PATCH AND REPAIR EXISTING DRYWALL AT DEMO AFFECTED AREAS. —Np ID-6 5. REMOVE EXISTING WALLS &DOORS AS NOTED ON PLAN. DEMO FLOOR DEMO NOTES: (AIR RETURN. RELOCATE � 1. REMOVE ALL EXISTING CARPET AND BASE PER PLANS. RETURN IN r 2. REMOVE ALL EXISTING LIGHT FIXTURES PER PLANS. I(E) WALL, I 3. REMOVE EXISTING CABINETS, DOORS, DOOR FRAMES AND GLASS PER PLANS. SEE ID-5 � I ACCESSIBILITY CODE NOTES: i� PANO VIEWING WINDOW, 24"X 14" X 1 /2" GLASS M I 0 NON—FUNCTIONAL DOOR NON—FUNCTIONAL DOOR 9'-7" 9'—s" 9'—s" 9'-6» 9'-6" FLOOR PLAN o 2' 4' 8' 12' SCALE: 1 /4"=1'-0" DOOR SCHEDULE: DOOR SCHEDULE NOTES: DOOR DOOR FRAME N0. REMARKS 1. SEE FINISH SCHEDULE FOR DOOR FINISH SPECIFICATIONS. 2. PROVIDE (3) DOOR SILENCERS FOR EACH INTERIOR SWINGING DOOR TYPE WIDTH HEIGHT THICK MAT. FINISH GLAZ'G RATING HDWR TYPES MAT'L FINISH OE EXISTING DOORS (IVES SR64 OR SR65). 3. PROVIDE STANDARD WEIGHT COMMERCIAL DOOR HINGES. Ol A 3'-0" 7'-0" 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 NEW POCKET DOOR — MATCH EXISTING STAIN 4. ALL DOORS W/ CLOSERS TO HAVE BALL BEARING HINGES. 5. PROVIDE DOOR STOPS AT APPROPRIATE LOCATIONS. 6. DOOR HARDWARE TO MEET WAC-51-20 BARRIER —FREE CODE (LEVER STYLE HANDLES). MAXIMUM DOOR OPENING PRESSURES ARE LIMITED TO 8.5 LBS. AT EXTERIOR DOORS AND 5.0 LBS AT INTERIOR DOORS. 7. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE O2 A 3'-0" 7'-0" 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 (E) POCKET DOOR RELOCATED FROM DR'S OFFICE O3 A 3'-0" 7'-0" 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 (E) POCKET DOOR RELOCATED FROM HYG. 1 OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 8. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE A LEVER OR OTHER SHAPES WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. 9. CHECK LEAD TIMES AS SOME PRODUCT MAY HAVE LONGER LEAD TIME. 10. ALTERNATE MANUFACTURER'S MAY BE SELECTED WITH DESIGNER'S APPROVAL. 11. DOOR THRESHOLD SHALL NOT EXCEED 1 /2" IN HEIGHT. DOOR HDWR TYPES: A SECURITY LOCK — SCHLAGE AL SERIES, LEVER STYLE #17 IN SATIN CHROME, VERIFY TO MATCH EXISTING HARDWARE B PASSAGE — SCHLAGE AL SERIES, LEVER TO MATCH EXISTING HARDWARE C PRIVACY — SCHLAGE AL SERIES, LEVER STYLE #17 IN SATIN CHROME, VERIFY TO MATCH EXISTING HARDWARE D POCKET DOOR PULL — TRIMCO 1069-619 SERIES SLIDING DOOR PULL IN SATIN NICKEL. NOTE: SEE TYPICAL FLOOR TRANSITIONS DETAIL FOR THRESHOLDS E BI—FOLD DOOR PULL — 4" WIRE PULL IN SATIN CHROME. ABBREVIATIONS: (E) EXISTING H.M. HOLLOW METAL F SOUND/LIGHT GASKET — PEMKO PE319CN 3/16" SPONGE NEOPRENE D.G. DECORATIVE GLAZING SEAL FOR 3'x 7' DOOR W/ DRAFT SWEEP T.P. TEMPERED PLATE G DOOR CLOSER (PUSH SIDE) — SARGENT 351—PH9-26D (SATIN CHROME) PT—# PAINT H DOOR CLOSER (PULL SIDE) —SARGENT 351—H-26D (SATIN CHROME) S.C. WD SOLID CORE WOOD ST—# STAIN F.R.G. FIRE —RATED GLAZING ("FIRELITE") J WALL BUMPER DOOR STOP — IVES WS404 (SATIN CHROME) K FLOOR DOOR STOP — IVES FS436 DOME STOP (SATIN CHROME) N.R. NON —RATED L SMOKE/DRAFT GASKET — PROVIDE SMOKE &DRAFT GASKETING PER FIRE CODE. WALL TYPES: 1. IBC 1104.3.1, EXCEPTION 1 — EMPLOYEE WORK AREAS: COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS THAT ARE LESS THAN 1,000 S.F. IN SIZE AND DEFINED BY PERMANENTLY INSTALLED PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS, SHALL NOT BE REQUIRED TO BE ACCESSIBLE ROUTES. EXISTING WALLS TO REMAIN L________J EXISTING WALLS AND ITEMS TO BE DEMOLISHED NEW INTERIOR WALLS -- 5/8" G.W.B. EA SIDE OVER 3-5/8" METAL STUDS � 24" O.C.; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. SYMBOLS LEGEND: F.E.C. SEMI —RECESSED FIRE EXTINGUISHER CABINET, "JL INDUSTRIES" AMBASSADOR #CADA1816F10, W/ CLEAR ACRYLIC DOOR. MOUNT W/ BOTTOM LEADING EDGE 27" MAX A.F.F., PAINT TO MATCH WALL COLOR. WAITING ROOM NAME &NUMBER Ol O DOOR NUMBER ID-7 7 INTERIOR ELEVATION SYMBOL (INSIDE = SHEET; OUTSIDE = ELEVATION NUMBER) DOOR TYPES: --SOLID CORE WOOD DOOR W/ WOOD FRAME SEE SCHED. 2'— 0„ � I I I TEMPERED GLASS I I w I J I � I p I w I 2 I U I (/) � I w I N I I I i I i ______ J RES U B S.C. WOOD Jun 04 2021 POCKET DOOR CITY OFEDMONDS ❑ DEVELOPMENT SERVICES DEPARTMENT David Company CLIENT /PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: PERMIT SET PARTITION PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designerand may not be reproduced in part or whole without prior written permission. Project No.: 14-72 Date: 5/22/2021 PHASE OF WORK: PHASE WALL TYPES: --------� EXISTING WALLS TO BE DEMOLISHED EXISTING WALLS TO REMAIN rnl ii J II II I I X5 II II II I �------T------_ L-1-------L------_ X X I DEMO LIGHTING, I — TYP Ir ------T---------, -----T� I r--- X1 —� I r--- X1----� I t t -----� I LL-_____= JAL�_____= JJ I �� II II I �� II II �� II II �� II II �� II II rr �, � � I I I I �I I� � � I I I I I I I I I I I I I II II I I I I I I I II�II I I I I I I II%<II I I I I I I I � I I � i L- J L- r1X6rl J i I LJ I L-J I r-----------, r---� I II II I II II jI I I rr-------�Tr-------,1 I---------------------� Lr----------� I LL _= X�=== JAL -= X�=== JJ I --�1----------�� I DEMO HEADER I I I DEMO SOFFIT AND I CAN LIGHTING i i I --------- ----------------t fi--- I \�: ��: ��: I I � � � � � � � 1 1 � � � DEMO SOFFIT AND I `%SALVAGE CAN LIGHTING Fi ' X2 i i �+� �+� ��-�X5 ��-�X5 I I I I i��i � �' �C4 i i � --------------------------J I i� i� i� l ---------�� �L�X5 �_________ I II J ®X5 ®X5 ® ®X5 Fi I I �� J �> I I P` -'S I I ------ � �------- L1------- T------- T------T �____- ------1----------------, r1------L-------�- II II I I DEMOLITION REFLECTED CEILING PLAN SCALE: 1 /4"=1'-0" PHASE WALL TYPES: EXISTING WALLS TO REMAIN NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS � 24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. W/D 0 — r � - � \ / � X \ LAB � RESTRO®X5 102 101 O \ _ i 0 J ®X5 ,OP.; 103 0 N x _ STEERI �� r`� 110 �. I � 0 2' 4' 8' 12' H® I I I A WAITING I ®K G G 113 I 04 I EXISTING GWB CEILING I A + 8'-0" AFF I I R12'-11 3/4" I RECEPTION I 112 � 4 I � � � STAFF I 12'-2" 111 A I NEW GWB SOFFIT _ I I ®X5 + 7'-0" AFF I Ox17 / \ �� ®X5 OFFICE � H® -- 108 A X2 SURGICAL _ OP.6 � 109 I^ J ®XIbJCISTING GWB CEILING ®X5EXISTING GWB SOFFIT ®X5 + 8'-0" AFF ®H ®X5 I�?ll .. � :: LIGHTING FIXTURE SCHEDULE: � X1 �i DEMO EXISTING SURFACE MOUNTED 1' X 4' FLORESCENT L=== -----J LIGHT FIXTURES <120W>. r------_ --� X2 ii X2 ii EXISTING/RELOCATED 2' X 4' TROFFER. <84W> I I LL------- JJ �r'�X3 DEMO EXISTING RECESSED CAN LIGHTS. <40W> ' EXISTING/RELOCATED RECESSED LED CAN LIGHTS. <11.7W> �X4 �' X4 '+; EXISTING/RELOCATED SURFACE MOUNTED LIGHTS. <36W> X5 ��-�X5 X6 DEMO EXISTING RESTROOM VANITY LIGHTS. <180W> r�r� r� NEW 2' X 4' LED SURFACE MOUNTED FIXTURES PER A PLAN: "LITHONIA BLTX4-30L—ADP—EZ1—LP935 — 3500 KELVIN". <48W> NEW UNDER CABINET LED LIGHTS: "TECH LIGHTING UNILUME LED SLIMLINE 700—UCF—XX-8-2—W—LED", FINISH: WHITE. LENGTHS WILL VARY (7", 13", 19", 30"), SEE CABINET ELEVATIONS. BUTT FIXTURES TOGETHER AND G MOUNT DIRECTLY BEHIND VALENCE WITH DIFFUSER FACING WALL. ELECTRICIAN TO PROVIDE CONDUIT TO EACH LIGHT BANK. LOW PROFILE WITH ROCKER SWITCH; ALSO CONNECT TO ROOM LIGHT SWITCH. EXISTING EXIT LIGHTING: "SOLO W1GMRLASD—GREEN" FILL H® INDICATES SIDE OF SIGN WITH DIRECTIONAL ARROW EXISTING &NEW EMERGENCY PATHWAY LIGHTS: � "QUANTUM ELM2LF" EXHAUST FAN (MECH ROOM/MED GAS RM): "NUTONE K® QTXEN SERIES EXHAUST FAN QTXEN 150" <150 CFM>; PROVIDE THERMOSTAT SWITCH LIGHTING FIXTURE CONTROLS: SWITCH �2 DIMMABLE SWITCH �os OCCUPANT SENSOR SWITCH � � CIRCUIT PATHWAY LIGHTING NOTES: 1. USE ONLY UL APPROVED FIXTURES. SUBSTITUTIONS OF NON —RATED FIXTURES ARE NOT APPROVED. ELECTRICIAN TO VERIFY WHETHER 120V OR 277V SOURCE IS AVAILABLE AND ORDER FIXTURES ACCORDINGLY. 2. LIGHT FIXTURES NEED TO BE ORDERED A.S.A.P. AS SOME HAVE LONG LEAD TIMES. LIGHTING FIXTURE SPECS ARE NOT NECESSARILY COMPLETE AND MAY REQUIRE VERIFICATION OF NUMBER, ACCURACY AND ADDITIONAL OPTIONS TO COORDINATE WITH BUILDING POWER REQUIREMENTS. CEILING NOTES &SPECIFICATIONS: 1. EXISTING CEILINGS ARE ALL GWB. 2. ALL NEW SOFFITS --5/8" TYPE 'X' G.W.B. OVER 3-5/8" METAL STUDS, SMOOTH FINISH AND PAINTED FLAT LATEX ENAMEL. UNIT LIGHTING POWER ALLOWANCE (LPA): TOTAL SQUARE FOOTAGE 1,547 S.F. ALLOWABLE WATTS PER SQUARE FOOT N/A TOTAL ALLOWABLE WATTS (LESS THAN 50% OF LIGHTING IS BEING REPLACED) N/A TOTAL EXISTING WATTS (MAXIMUM ALLOWABLE WATTS) SEE WSEC LIGHTING SUMMARY REPORT: 2,002.5 WATTS TYPE EXEMPT FIXTURES (LOC.) LAMPS WATTS EA. COUNT (E) + N WATTS G UNDER CABINET TASK LED — 14 +2 = 16 N/A H EXISTING EXIT SIGNS LED — 2 +0 = 2 N/A J EXISTING EMERGENCY EGRESS LIGHTING LED — 3 +0 = 3 N/A X2 2 X 4 FLOR TROFFERS (TASK EXCEPTION) 3 TUBES 48 6 +0 = 6 N/A TYPE FIXTURES LAMPS WATTS EA. COUNT (E) + N WATTS A 2 X 4 LED TROFFERS LED 48 0 +4 = 4 192 X2 2 X 4 FLORESCENT TROFFERS 3 TUBES 84 10 +0 = 10 840 X4 RECESSED LED CAN LIGHTS LED 11.7 5 +0 = 5 58.5 X5 SURFACE MOUNTED LED LIGHTS LED 36 8 +0 = 8 288 David Company CLIENT /PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: PERMIT SET REFLECTED CEILING PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designerand may not be reproduced in part or whole without prior written permission. REFLECTED CEILING PLAN SCALE: 1 /4"=1'-0" 0 2' 4' 8' 12' TOTAL WATTS USED 1 MEETS WSEC UNIT LPA 1,378.5 < 2,002 5 S CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project No.: 14-72 Date: 5/22/2021