Loading...
APPROVED PLN_BLD RESUB1 BLD2021-0546+Mechanical_Plan+5.13.2021_11.30.42_AM+21951450 APPROVED •ANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED BY PLANNING May 20 2021 Work City Of Edmonds Building Department MECHNICAL FOR T/I ------------------- ----------------- Address 22815 EDMONDS WAY --------------------------------------------- ----------------------------------------------- Owner DISTINCTIVE DENTISTRY -------------------------------------------------- ----- •----------------------- Approved Date 5-17-2021 Building Official Erit, Ga4-ter Permit Number BLD2021-0546 U N ITED S SYSTEM S ML H ^ N I CAL LLC A FULL SERVICE COMMERCIAL HVAC CONTRACTOR 1400 AIRPORT WAY SOUTH SUITE 202 SEATTLE, WASHINGTON 98134 (206)933-6036/FAX 937-3084 REVISIONS DATE DISCRIPTION 4/23/2021 DESIGN REVISION #1 5/12/2021 CITY CORRECTION NOTICE #1 O z W a. z H H F Z W 0 It F Z B O O FM 00 W N N W .LO 00 N O E W FILE NAME Dr. Streit / Innovative Dentistry PROJECT ENGINEER PC DATE REVISED 4/12/21 JOB NUMBER 9739 SHEET NUMBER M =1 DPD STAMP RESUB May 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT L THESE DRAWINGS ARE THE PROPERTY OF UNITED SYSTEMS MECHANICAL LLC AND MUST NOT BE REPRODUCED, ALTERED OR USED WITHOUT THE PRIOR WRITTEN AUTHORITY OF UNITED SYSTEMS LLC. THESE DRAWINGS ARE TO BE USED ONLY AS SUPPLEMENTARY TO THE ARCHITECT'S DRAWINGS AND SPECIFICATIONS ANY PROPOSED VARIATIONS OR DEPARTURES FROM THESE DRAWINGS MUST BE APPROVED BY UNITED SYSTEMS MECHANICAL LLC. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE CAP OFF EXISTING CEILING GRILLE AND REPLACE WITH NEW 16"x4" SIDEWALL SUPPLY AIR GRILLE WITH OBD. BALANCE TO 200 CFM APPROVED PLANS MUST BE EXISTING CEILING DUCT CHASE ON JOB SITE F-1: EXISTING GAS FURNACE WITH EXISTING 3-TON SPLIT -SYSTEM AC. REBALANCE MINIMUM OSA TO 108 CFM CAP OFF EXISTING CEILING GRILLE AND REPLACE WITH NEW 16"x4" SIDEWALL SUPPLY AIR DEMO EXISTING GRILLE WITH OBD. BALANCE TO CLG EF & CAP 250 CFM. (2-TYP) EXISTING DUCT. --------�-----------------\�-------------- 0 N 0 N Oo OP #2 OP #1 110 109 00 0 00 REPLACE EXISTING HIGH WALL RETURN GRILLE WITH NEW 18"x18" 0 • 0 0 0 REPLACE EXISTING 0 0 0 OP # P CEILING GRILLE AND OP #6 113 REPLACE WITH NEW 8"x8" MODULAR CORE 114 DIFFUSER WITH OBD. BALANCE TO 150 CFM. 00 — 0 0 0 m T d N CBCT 107 00 EXISTING CEILING DUCT CHASE o 0 STERILE N� 00 0 00 BDD N F 1_4 HALL NEW 8" ROUND EXTERIOR WALL EYEBROW STYLE EXHAUST TERMINATION WITH BDD Z__�AEF-1- NEW INLINE EXHAUST FAN IRELOCATE EXISTING HI/LOW COMBUSTION AIR GRILLES TO THIS LOCATION - FIELD VERIFY. CAP OFF EXISTING CEILING GRILLE AND REPLACE WITH NEW 6"x4" SIDEWALL SUPPLY AIR GRILLE WITH OBD. BALANCE TO 50 CFM. I CAP OFF EXISTING CEILING GRILLE AND REPLACE WITH NEW 6"x4" SIDEWALL SUPPLY AIR GRILLE WITH OBD. BALANCE TO 60 CFM. 03 v v REMOVE EXISTING CEILING REMOVE EXISTING CEILING GRILLE & CAP DUCT. GRILLE & CAP DUCT. RELOCATE F-1 THERMOSTAT TO EF-2: NEW CLG MOUNTED IHP-2-2: RELOCATE EXISTING 0 THIS LOCATION AND REPLACE EF WITH NEW 6" ROUND INDOOR UNIT TO THIS R.R WITH A NEW HONEYWELL EXHAUST DUCT UP LOCATION ABOVE EXISTING y I COMMERCIAL 7-DAY THROUGH ROOF WITH BDD OPERABLE WINDOW. 10 I PROGRAMMABLE THERMOSTAT. MODEL# MSZ-GL06NA NEW 6" ROUND EXTERIOR WALL EYEBROW STYLE VENT TERMINATION WITH INSECT SCREEN R EF-4: NEW CLG MOUNTED EF WITH NEW 6" ROUND EXHAUST DUCT OUT THROUGH EXTERIOR WALL WITH BDD IHP-1-1: RELOCATE EXISTING INDOOR UNIT TO THIS LOCATION. MODEL# FTXS12LV-JU NEW 6"x6" SWS OSA/VENTILATION GRILLE. BALANCE TO 50 CFM MAIN FLOOR/RCP HVAC T.I. PLAN SCALE: 1/491=11=011 TANKS � 115 �W A=NS 1 10 O TTp 0 OHP-1: EXISTING 2-TON MULTI -ZONE HEAT PUMP - DAIKIN MODEL 3MXS24NMVJU R.R. 104 OO co v v NEW HIGH/LOW 8" ROUND EXTERIOR WALL EYEBROW STYLE VENT TERMINATIONS WITH INSECT SCREEN FOR NEW MED GAS CLOSET NEW 6" ROUND EXTERIOR WALL EYEBROW STYLE VENT TERMINATION WITH INSECT SCREEN OHP-2: EXISTING 3.5-TON MULTI -ZONE HEAT PUMP - MITSUBISHI MODEL MXZ-5C42NAZ EF-3: NEW CLG MOUNTED EF WITH NEW 6" ROUND EXHAUST DUCT OUT THROUGH EXTERIOR WALL WITH BDD IHP-2-1: RELOCATE EXISTING INDOOR UNIT TO THIS LOCATION. MODEL# MSZ-GL06NA NEW 6" ROUND EXTERIOR WALL EYEBROW STYLE VENT TERMINATION ABOVE STORAGE ROOM DOOR WITH INSECT SCREEN SF-1: NEW INLINE SUPPLY FAN AND AIR FILTER RACK. DH-1: NEW 1 KW DUCT HEATER EF-5: NEW CLG MOUNTED EF WITH NEW 6" ROUND EXHAUST DUCT OUT THROUGH EXTERIOR WALL WITH BDD NEW 6" ROUND EXTERIOR WALL EYEBROW STYLE VENT TERMINATION WITH INSECT SCREEN EXISTING UNHEATED STORAGE CLOSET UNDER 2ND FLOOR EXTERIOR STAIRS INSULATE NEW LOW PRESSURE VENTILATION DUCT WITH R-8 DUCT WRAP AND SEAL PER CODE. IHP-1-2: RELOCATE EXISTING INDOOR UNIT TO THIS LOCATION. MODEL# FTXS12LV-JU PIPING NOTE: RELOCATE EXISTING IHP REFRIGERANT PIPING AND CONDENSATE PIPING TO NEW INDOOR IHP LOCATIONS. THE EXISTING CONDENSATE PIPING TO BE ROUTED WITH THE REFRIGERANT PIPING TO THE EXTERIOR WALL PENETRATIONS AND TERMINATE ON GROUND NEXT TO THE OH LOCATIONS (EXISTING CONDITION!) U N ITED m SYSTEM S NAL :H^N I CAL L LC A FULL SERVICE COMMERCIAL HVAC CONTRACTOR 1400 AIRPORT WAY SOUTH SUITE 202 SEATTLE, WASHINGTON 98134 (206)933-6036/FAX 937-3084 REVISIONS DATE DISCRIPTION 4/23/2021 DESIGN REVISION #1 o U) N O W co OL F F mm Z W 0 w N W��� Lu > o 0 0 t �E�, W W z 1■1� Q F co N z 0 0 W Z FIIIIIIIIIIIIIII W FILE NAME Dr. Streit / Innovative Dentistry PROJECT ENGINEER PC DATE REVISED 4/12/21 JOB NUMBER 9739 SHEET NUMBER M=2 DPD STAMP RESUB May 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT L THESE DRAWINGS ARE THE PROPERTY OF UNITED SYSTEMS MECHANICAL LLC AND MUST NOT BE REPRODUCED, ALTERED OR USED WITHOUT THE PRIOR WRITTEN AUTHORITY OF UNITED SYSTEMS LLC. THESE DRAWINGS ARE TO BE USED ONLY AS SUPPLEMENTARY TO THE ARCHITECT'S DRAWINGS AND SPECIFICATIONS ANY PROPOSED VARIATIONS OR DEPARTURES FROM THESE DRAWINGS MUST BE APPROVED BY UNITED SYSTEMS MECHANICAL LLC.