REVIEWED RESUB1 BLD2021-0546+Manufacturer_Specifications_and_Installation_Instructions+5.13.2021_11.30.43_AM+2195147fantech R a systemair company RESUB May 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0546 FG 4 Centrifugal Inline Fan 4" inline duct fan w/metal housing, 120V, 1 Item Number: 40402 Variant: 120V 1- 60Hz [" ®■ C D Us N NVI A multi -purpose inline duct fan for exhaust or supply air; ideal for commercial and residential ventilation applications. Customers benefit from the seamless, leak -free design, low noise operation, easy installation and reduce maintenance requirements, ensuring project cost and timelines are optimized. The fan is suitable for indoor applications and can be mounted at any angle in any point along the ductwork. • Airflow 110 cfm at 0.2" Ps • Mounting bracket and hardware included • Suitable with indoor installations • Speed controlled with solid-state speed controller WC15 or ON/OFF push-button 60 min timer FD60EM • 5-year factory warranty • ENERGY STAR® listed The housing is manufactured from a two-piece stamped, galvanized construction. The two halves are joined using Fantech's unique folded seam closure, which gives the fan the first in class, airtight seal. Installations in duct connected and wet room applications of the fan are possible due to the airtight casing. The fan motors are capable of operating in air stream temperatures up to 140oF and the motor bearings are permanently sealed, self -lubricated for maintenance -free life. FG4 has a built-in thermal overload protection with automatic reset needing no user intervention. With the motor in the airstream, the fan provides the constant dissipation of heat build-up thus giving the fan first in class for longevity and reliability. The mounting bracket and hardware are included, and the fan is ENERGY STAR® listed and comes with 5-year factory warranty. Choose from a variety duct accessories to make your installation straightforward and time efficient. Technical parameters Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1 - 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Pagel of 8 Norminal data Voltage (nominal) 120 V Frequency 60 Hz Phase(s) 1 Input power 20 W Input current 0.18 A Impeller speed 2,886 r.p.m. Air flow max 139 cfm Temperature of transported air max 140 OF Max temperature of transported air, when speed controlled 140 IF Protection/Classification Enclosure class. motor IP44 Insulation class Dimensions and weights Duct dimension; Circular, inlet Duct dimension; Circular, outlet Weight Optional Duct connection type B 4 in. 4 in. 4.6 lb Circular Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 2 of 8 Performance Performance curve in. wg. 0. 0. 0. 0. jWdo -A 11 _-- �- J1 I cim Hydraulic data Required air flow 50 cfm Required static pressure 0.50 in. wg. Working air flow 50 cfm Working static pressure 0.50 in. wg. Air density 0.075 Ib/ft3 Power 0.02 hp Fan control - RPM 2696 rpm Current Airflow efficiency 3.5 cfm/W Control voltage 120.0 V Supply voltage 120 V Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 3 of 8 Performances CFM Table Model 0" 0.2" 0.4" 0.6" 0.8" 1.0" 1.5" 2.0" Ps Ps Ps Ps Ps Ps Ps Ps FG 4 135 110 83 55 25 - - FG 4XL 170 150 134 119 103 86 40 FG 5XL 220 190 160 135 112 91 41 FG 6 303 270 232 196 164 134 58 - FG 6M 418 370 317 268 224 186 101 16 FG 6XL 483 450 409 369 329 289 201 - FG 8 461 410 351 295 243 191 97 14 FG 8XL 502 470 428 388 351 313 218 100 FG 10 513 480 444 407 366 324 216 90 FG 589 560 531 503 472 441 355 260 10XL FG 12 741 680 601 515 434 363 236 141 FG 940 880 819 746 670 596 425 400 12XL Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 4 of 8 Dimensions A 1 Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 601-lz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 5 of 8 Model A C D E F 4XL 4 (101) 9 3/4 (248) 6 15/16 1 (25) 1 (25) 5 5 (127) 8 5/8 (219) 6 1/2 (165) 1 (25) 1 (25) 5XL 5 (127) 9 3/4 (248) 6 (152) 1 1/8 (29) 1 1/8 (29) 6 6 (152) 11 3/8 (289) 6 1/4 (159) 1 (25) 7/8 (22) 6XL 6 (152) 13 1/8 (333) 7 (178) 1 (25) 1 (25) 6M 6 (152) 13 1/8 (333) 7 (178) 1 (25) 1 (25) 8, 8XL 8 (203) 13 1/4 (337) 6 (152) 1 1/8 (29) 1 (25) 10 10 (254) 13 1/4 (337) 43/4 (121) 1 1/8 (29) 1 (25) 10XL 10 (254) 13 1/4 (337) 4 13/16 (122) 1 1/4 (32) 1 (25) 12, 12XL 12 (305) 16 (406) 6 11/16 (170) 1 1/2 (38) 1 (25) Dimensions are in inches (mm). Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 6 of 8 Wiring Motor Leads Capacitor ° L Supply voltage IN Ground Capacitor ,c------------ Brown Green/Yellow a Wire motor L (Black) N (White) Ground Brown l 0 Black O Blue O GreerVYellow I Capacitor I L N Ground 4 WITe motor Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 601-lz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 7 of 8 Accessories • FAT10 Attic Thermostat (411233) • IPF05 Fan Speed Control (5A) (484164) • VT20M Pgrm Fan Main Ctrl (45386) • FIDT 4 Insulated Flex Duct (411061) • FC 4 Mounting Clamps (2 pcs) (411295) • IR 4 Iris Damper (411234) • MGE 4 Metal Exhaust Grill (411106) • PBL10-4 Bath Fan Grill w/ LED (44952) • PBV4 Bath Fan Grill (412260) Documents • 450369 FG Submittal Sheet EN.pdf • 400017 FG OIPM EN FIR ES.PDF • 40402.dxf Specification • FD60EM Electronic Timer Switch (411386) • IPHS5 Humidity / Fan Control (156040) • WC 15 Speed Control (5A) (411102) • ADC 4 Shut-off Damper w Motor (44966) • IG 4 Inlet Guard (411301) • LID 4 Silencer (411282) • MGS 4 Metal Supply Grill (411368) • PBL74 Bath Fan Grill w/ LED (44951) Description A centrifugal type exhaust/supply fan specifically designed for moderate size ventilation applications. The fan can be mounted at any angle in any point along the duct work and straight -through air flow design allows easy installation. By using FC type mounting clamps, fan can be easily removed from duct work for service. Fans are constructed in accordance with standard dimensions for spiral duct eliminating the need for transition pieces. Fan motors are capable of operating in air stream temperatures up to 140o F. Motor bearings are a permanently sealed, self lubricating ball type. All fans are 100% speed controllable through a decrease in the voltage by using a solid state or transformer type control. All FG Series fans are backed by Fantech's Five Year Warranty. Guide Specifications for Model FG Inline Duct Fans Supply, exhaust or return air inline fans shall be of the centrifugal, direct driven type. Housing: Fan housing shall be constructed of heavy gauge galvanized sheet metal Fan shall be supplied with externally mounted electrical terminal box with pre -wired terminal strip connections Capacitor shall be located within electric terminal box Motor: Motorized impeller shall be an external rotor type, class B insulation, enclosed with permanent split capacitor Motor shall be a permanently sealed self lubricating ball bearing type Motor shall be quipped with automatic reset thermal overload protection Motor shall be acceptable for continuous duty Wheel: Fan wheel shall be of the backward inclined centrifugal type with a well designed inlet venturi for maximum performance Motorized impeller shall be both statically and dynamically balanced as one integral unit to provide for vibration free performance Impellers shall be molded of high impact polypropylene Performance: Fan air flow performance shall be based on tests conducted in accordance with AMCA Standard 211 and shall be licensed to bear the AMCA Certified Ratings label Code Approval: Fan shall be tested and approved by UL and CSA (or equals) for safety FG Series shall be manufactured under the authority of Fantech, Inc., Lenexa, KS Item name: FG 4 Centrifugal Inline Fan I Product link: https://shop.fantech.net/en-US/productPermalink?p=105319 I Item Number: 40402 1 Variant: 120V 1- 60Hz Document type: Product card I Created at: 2021-05-07 1 Generated by: Fantech Online Catalogue I Language: English Page 8 of 8 Lz�LL DH-1 r.= • New expanded range • Capacities from 1 to 12 KW • Fits from 5" to 12" diameter ducts • Built-in adjustable electronic duct sensor (adjustable from 0°C to 42°C / 32°F to 108°F ) • Equipped with the most advanced Electronic Modulating Controller and Patented Air Flow Sensor • Just one electrical connection and the unit is ready to perform Today's airtight homes and offices beg for fresh air. When we trap the heat, excess humidity and indoor pollutants such as cleaning products, smoking and pets, will negatively affect the quality of the air we breathe, making our environment both uncomfortable and unhealthy. Stale and humid air has to be replaced by fresh air. During winter, the incoming fresh air is at too low a temperature to be comfortable and requires preheating. It is more economical to preheat the incoming air at a specific, controlled source than requiring the central system to continually compensate for heat loss. (."'New 5a,5) The THERMO-AIR heater is designed to complement your heating system by preheating this fresh air at the lowest cost, thus continuously providing comfortable ventilation throughout the house. Equipped with the most advanced modulating controller and air sensor, the THERMO-AIR heater will operate with extremely low air flow (see specifications). The unit uses the minimum amount of energy required to meet your needs. The air flow sensor detects the amount of air flowing through the unit and modulates the heating capacity accordingly, maximizing savings. The THERMO-AIR heater is a quality product engineered for peak performance and long life. DH-1 THERMOmAIR, FEATURES AND SPECIFICATIONS ------Z-------- Y - -------X-- - - - - - - B 11.5" 10.0" 13.5" C 15.5" 12.0" 15.5" To specify the model required, follow the example below: TER-6-2-240 COLLAR SIZE --J I VOLTAGE KILOWATTS Automatic Reset Thermal Cut-out Safety feature preventing overheating; will reset automatically after cool -off. Air Flow Sensor Modulates the heating capacity according to the quantity of air flowing through the heater. Open Coil Elements Made of the highest grade nickel -chrome resistance wire, they will not age or oxidize, thus assuring longer heater life. Temperature Sensor Controls the heater proportionally to maintain the pre-set air temperature in the duct. Enclosure Corrosion resistant galvanized steel. Built-in Electronic Temperature Controller and Sensor Proportionally modulates the heating load to match the exact capacity required, thus minimizing operating cost. Manual Reset Thermal Cut-out Additional safety feature which prevents the frame from overheating. Round Collars Simplifies the installation and considerably reduces field labor. Terminal Block Only one electrical connection required through an easily accessible power terminal block. - AVAILABLE STOCK MODELS: 5" or " 5" or 6" 8" or 10" 8" or 10" 8" or 10" 8" or 10" 12" 10" or 12" 10" or 12" 10" or 12" 2 240V/8.3A or 208V/9.6A or 120V/16.7A 60 A 3 240V/12.5A or 208V/14AA 90 B 4 240V/16.7A or 208V/19.2A 120 B 5 240V/20.8A or 208V/24.OA 150 B 6 240V/25.OA 180 B 6 240V/25.OA 180 C 8 240V/33.3A 240 C 10 240V/41.6A 300 C 12 240V/47.9A (11.5KW) 345 C Specifications are for standard units. For other DH-1 Model # TER-6-1-120 sizes, voltages and capacities, please contact your Thermolec representative. TYPICAL APPLICATIONS OF THE THERMO AIR HEATER HEAT PUMP ''•.• ♦ J FRESH Al HEATER HEAT Heat RECOVERY UNIT Recovery WALL CAP Ventilation & Heat Pump FURNACE ' DISCHARGE GRILLE = 6 RETURN AIR a FAN DUCT • �• FRESH AIR HEATER FRESH AIR HEATER INSULATION INSULATION_ WALL CAP WALL CAP Central Air Hydronic or Furnace Baseboard Heating 11 THERMOLEC TEL.: 514-336-9130 / FAX: 514-336-3270 Web: www.thermolec.com ca C us