Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Manufactures Specifications
Job Name: System Reference: I Date: Indoor Unit: UP Outdoor Unit: Wireless Remote Controller MFZ-KJ12NA M RECEIVED Sep 21 2021 DEVELOPMENT $ERVICEE GENERAL FEATURES Floor -mounted indoor unit mounts on the floor or up to 5" above the floor Floor front panel access to the filter for ease of cleaning • Perfect for difficult areas that may be smaller or don't have usable space on the walls • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto Quiet operation Multi -flow vane for faster heating • Multiple control options available: - Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options - Wired or wireless controllers • Unit can be recessed mounted into wall Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity BTU/H 15,000 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 2,300 Coolingl Maximum Power Input W 1,380 Rated Power Input W 890 Moisture Removal Pints/h 2.7 Sensible Heat Factor 0.70 Power Factor % 90 / 90 Maximum Capacity BTU/H 22,800 Rated Capacity BTU/H 13,000 Heating 47°Fz Minimum Capacity BTU/H 2,900 at Maximum Power Input W 2,390 Rated Power Input W 900 Power Factor % 89 / 89 Maximum Capacity BTU/H 14,800 Heating 17°F3 Rated Capacity BTU/H 8,800 at Maximum Power Input W 1,890 Rated Power Input W 930 Heating 5°F4 Maximum Capacity BTU/H 13,000 at Maximum Power Input W 1,810 Heating at -4°F5 Maximum Capacity BTU/H 10,790 Heating at -13°F5 Maximum Capacity BTU/H 8,450 SEER 25.5 EERY 13.6 HSPF (IV) 12.0 Efficiency COP at 47°F2 4.23 COP at 17°F in Maximum Capacity3 2.30 COP at 5°F in Maximum Capacity4 2.11 ENERGY STAR® certified units(ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) YES Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size (Outdoor) A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.62 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 417-360-272-198-138 Airflow Rate at Cooling, Wet CFM 354-306-231-168-117 Airflow Rate at Heating, Dry CFM 417-328-254-191-138 Indoor Unit Sound Pressure Level (Cooling) dB(A) 46-41-34-27-21 Sound Pressure Level (Heating) dB(A) 46-40-34-27-21 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color White Unit Dimensions W: In. (mm) 29-17/32 (750) D: In. (mm) 8-15/33 (215) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. H: In. (mm) 23-5/8 (600) Package Dimensions W: In. (mm) 32-2/16 (816) D: In. (mm) 10-13/16 (275) H: In. (mm) 27-12/16 (693) Unit Weight Lbs. (kg) 33 (15) Package Weight Lbs. (kg) 41 (18.5) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB / 73 WB // 67 DB / 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB // 70 DB MCA A 11 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 50 Airflow Rate CFM 1,074 / 1,202 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling' dB(A) 50 Sound Pressure Level, Heating2 dB(A) 48 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB140FQUMT Outdoor Unit Compressor Rated Load Amps A 8.2 Compressor Locked Rotor Amps A 10.3 Compressor Oil Type // Charge oz. FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Built-in Unit Dimensions W: In. (mm) 31-1/2 (800) D: In. (mm) 11-1/4 (285) H: In. (mm) 21-5/8 (550) Package Dimensions W: In. (mm) 37 (940) D: In. (mm) 14-15/16 (380) H:In. (mm) 24-13/16(630) Unit Weight Lbs. (kg) 83 (38) Package Weight Lbs. (kg) 89 (41) Cooling Air Temp (Maximum / Minimum)* °F 14 to 115 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F 11 / 14 Temperature Range Heating Air Temp (Maximum / Minimum) °F -13 to 75 Heating Thermal Lock -out / Re -start Temperatures** °F -18 / -14 Refrigerant Type R410A Charge Lbs, oz 2,10 Gas Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Notes AHRI Rated Conditions (Rated tCooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB data is determined at a fixed zHeating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB Conditions 51-leating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB fiHeating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Floor Mount Air Guide ❑ MAC-760FD-E Anti -allergy Enzyme Filter ❑ MAC-408FT-E kumo touchT RedLINKM Wireless Controller ❑ MHK2 Deluxe MA Remote Controller) ❑ PAR-40MAAU Simple MA Controller' ❑ PAC-YT53CRAU-J Touch MAControllerl Wired Remote Sensor ❑ PAR-CT01MAU-SB ❑ M21 EAA307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 System Control Interface2 ❑ MAC-3341F-E Wireless Interface 2 ❑ PAC-USWHS002-WF-2 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H[recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Guides air flow for floor mount model when a concealer is used to hide the floor mount. ❑ MAC-760FD-E I Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide ❑ MAC-881SG Hail Guard ❑ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD400P Condensing Unit Mounting Pad 16" x 36" x 3" ❑ ULTRILITE1 Outdoor Unit Stand —12" High ❑ QSMS1201M Outdoor Unit Stand —18" High ❑ QSMS1801M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket-316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-65 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air outlet area 49.30 sq in 28-3/4 Remote controller 2-3/8 3/4 Installation plate v N m _ v 29-17/32 m 25-53/64 1-27/32 Indoor unit Air out a Gas pipe 0 09/12: s3/8(flared) 15/18:01/2(flored) Air in 4-3/32 Liquid pipe 111;WIIS9 Unit: inch BMI-TIIV 09 / 12 1 15 / 18 For liquid line 1-1/16 O.D Pipe cover For gas line 1-1/16 O.D 1-7/32 O.D Liquid line Flared connection 1/4 Piping Gas line Flared connection Flared connection 3/8 1/2 Heat insulater Connection point Effective length Drain hose 13-25/32 1-9/64 O.D 5/8 O.D (case of right backward piping) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE "1 4 in. or more when front and sides of the unit are clear J m U v Air in r n Drain hole 01-5/16 MM e.2 Air in L o m ° $.\�,01 7pllp L= i o� 0 1 m o rn M.0 '2 When any 2 sides of left, right 1-9/16 and rear of the unit are clear Air out 2 x hole 3l8 x 13/16 a v FORM# MFZ-KJ12NA / MUFZ-KJ I2NAHZ - 202009 Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 Unit: inch ote 1340 Satellite Boulevard, Smanee, GA 002430024 Toll Free: 800-433-4822 www.meWac.com .(Due AffIntertek Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.