Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-1321_Manufacturer_Specifications_and_Installation_Instructions_9.28.2021_8.58.12_AM_2431883
A*W?4WS*od&rdo HEATING & AIR CONDITIONING Submittal Side Discharge HP Model For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. Epoxy Coated Model 4A6L6042A1000A 4A61_6042A1COTA Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2018 4A6L6042A-SUB-1 A-E N I Ingersoll Rand A*WewS7�wdard. HEATING & AIR CONDITIONING SAFETY SECTION Important — This document contains service information. This is customer property and is to remain with this unit. Please return to service information pack upon completion of work. HAZARDOUS VOLTAGE! Failure to follow this Warning could result in property damage, severe personal injury, or death. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. REFRIGERANT OIL! Failure to follow this Warning could result in property damage, severe personal injury, or death. These units use R-410A refrigerant which operates at 50-70% higher pressures than R-22. Use only R- 410A approved service equipment. Refrigerant cylinders are painted a "Rose" color to indicate the type of refrigerant and may contain a "dip" tube to allow for charging of liquid refrigerant into the system. All R-410A systems use a POE oil that readily absorbs moisture from the atmosphere. To limit this "hydroscopic" action, the system should remain sealed whenever possible. If a system has been open to the atmosphere for more than 4 hours, the compressor oil must be replaced. Never break a vacuum with air and always change the driers when opening the system for component replacement. For specific handling concerns with R-410A and POE oil, reference Retrofit Bulletin TRN-APG02—EN. HOT SURFACE! May cause minor to severe burning. Failure to follow this Caution could result in property damage or personal injury. Do not touch top of compressor. CONTAINS REFRIGERANT! Failure to follow proper procedures can result in personal illness or injury or severe equipment damage. System contains oil and refrigerant under high pressure. Recover refrigerant to relieve pressure before opening system. GROUNDING REQUIRED! Failure to inspect or use proper service tools may result in equipment damage or personal injury. Reconnect all grounding devices. All parts of this product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. SERVICE VALVES! Failure to follow this warning will result in abrupt release of system charge and may result in personal injury and/or property damage. Extreme caution should be exercised when opening the Liquid Line Service Valve. Turn valve stem counterclockwise only until the stem contacts the rolled edge. No torque is required. BRAZING REQUIRED! Failure to inspect lines or use proper service tools may result in equipment damage or personal injury. if using existing refrigerant lines make certain that all joints are brazed, not soldered. ©2017Ingersoll Rand 4A6L6042A-SUB-1A-EN HEATING & Al R CONDITIONING Outline Drawing GAS LINE I/4 TURA BALL SERVICE VALVE, "D I.D. FEMALE BRAZED CON NECTIOX WITN I/4' SAE f LARE PRESSURE iAP FITTING. IOUID LINE SERVICE VALVE, "E" I. p. f[NAL[ BRAZE <OXXFCTION WITH I14' SAE FLARE PRESSURE TAP FITTINGS. CE PANEL N T J G FIGURE 2 363 [I4-91321 ¢28 11-313t] x lGx VOLTAGE 13 [2-R/81 —on ["S' LOW VOLTAGE ELECTRICAL AND REFRIGEI CONPONENT CLEARANCES PER PREVAILING CODES. —LIW ID LINE SERVICE VALVE, "E" I.D. "' BRAZED CONNECTION WITH Il4" SAE FLARE PRESSURE TAP FITTING GAS LIir NE SERVICE VALVE, J� I.D. FFNALE BRA,.CONNFC 110N WITNSAE FLARF G PAESSU Af TAP FITTING. FIGURE I Model Base A B C D E F G H J 4A6L6042A 4.3 934 1194 445 20 8 53 187 101 159 (36-3/4) (47) (17-1/2) (25/32) (5/16) (2-1/16) (7-11/32) (3-31/32) (6-1/4) SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A) ] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6L6042A 73 56 77 76 71 67 62 56 48 Note: Rated in accordance with AHRI Standard 270-2008 *For reference only 4A6L6042A-SUB-1 A-E N 3 A*WewS7�wdard. HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A6L6042A1XXXA POWER CONNS. — V/PH/HZ (c) 208-230/1/60 MIN. BRCH. CIR. AMPACITY 25 BR. CIR. PROT. RTG. — MAX. (AMPS) 40 COMPRESSOR DURATION@- SCROLL NO. USED — NO. STAGES 1 — 1 VOLTS/PH/HZ 208-230/1/60 R.L. AMPS (d)— L.R. AMPS 19.2 — 124 FACTORY INSTALLED START COMPONENTS (e) NO (USE BAYSKT263) INSULATION/SOUND BLANKET NO SUMP HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 3718 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208-230/1/60 F.L. AMPS 1.19 OUTDOOR COIL — TYPE PLATE FIN ROWS—F.P.I. 2-16 FACE AREA (SQ. FT.) 12.88 TUBE SIZE (IN.) 5/16 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 7 LBS, 10 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) (i) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 40.88 X 54.5 X 23.0 WEIGHT SHIPPING (LBS.) 244 NET (LBS.) 217 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. W Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). 0) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for full charging instructions. 4A6 L6042A-SUB-1 A-E N S�i�� HEATING & Al R CONDITIONING Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The aluminum plate fin, copper tube outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected with a corrosion resistant mesh coil guard. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. 4A6L6042A-SUB-1 A-E N Cjv�)lngersoll Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands —including Club Caro, Ingersoll Rande, Thermo Kings and Trane'E'—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. 40)lngersoll Rand T THERMO KING G MtWE® ingersollrand.com c0%mus Intertek The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A6L6042A-SUB-1A-EN 01Jan2018 Supersedes (New) ©2017Ingersoll Rand