REVIEWED BLD2021-0708+Interior_Lighting_Summary+5.24.2021_11.23.42_AM+2213021refox
https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Administered by: @2021 NEEA, All rights reserved
Project & Applicant
Information
Project Title
MTI Physical Therapy Clinic - Edmonds - 2018 WSEC
For Building Department Use: Date: May 21, 2021
Project Address
21616 76th Ave West
102
Edmonds, WA 98026
Applicant Name
David Sova
Applicant Phone
206-617-9010
Applicant Email
david@dsdaa.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Office, Medical
Building Cond. Floor Area
2,675
General Project Types
Alteration
New Building or
Addition
Lighting Scope
9 9 p
Alteration
Lighting Scope
Interior Lighting
Project Cond. Floor Area
2,675
Floors Above Grade
1
Compliance Method
Compliance Method 1 -General
Lighting Project Description
Interior alterations to an existing medical office
Lighting Compliance Scope
Project Type
Interior / Exterior
(Interior includes both interior & parking)
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Adjustment
Compliance Verification
and Method
Alteration
Interior Lighting
less than 50% replaced
No Calculation Adjustments allowed
COMPLIES
Additional Efficiency
Options Included
Project Title
MTI Physical Therapy Clinic - Edmonds - 2018 WSEC
Date
May 21, 2021
Lighting Power Calculation
ALTERATION - INTERIOR LIGHTING (less than 50% replaced)
Compliance Verification
COMPLIES
Interior Lighting Power Allowance
Space Type
Existing Lighting Wattage Prior to Alteration
Total Watts Allowed
Proposed Lighting Total Watts
By Building Area
Compliance Status
Existing Lighting
2,484
2,484
Proposed Lighting Power Density- Spaces with less than 50% fixtures replaced
Fixture Type
Fixture ID
Quantity of
Fixtures (#F)
Watts or
Wattage Limit
per Fixture
(WpF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Troffer
2x4
38
60
2,280
Recessed downlight
6" recessed can light
10
18
180
Task lighting
sconce
1
24
24
Proposed Total LPD
2484
Project Title
MTI Physical Therapy Clinic - Edmonds - 2018 WSEC
Date
May 21, 2021
Proposed Fixtures Details
ALTERATION - INTERIOR LIGHTING (less than 50% replaced)
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
New or
Existing -to -Remain
Individual Fixtures
Troffer
2x4
A1.2
LED
Existing -to -Remain
Fixture Description:
of 2 5/21 /2021, 9:00 AM
refox
https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3
Recessed downlight
6" recessed can light A1.2 Compact Fluorescent
Existing -to -Remain
Fixture Description:
Task lighting
sconce A1.2 Compact Fluorescent
Existing -to -Remain
Fixture Description: toilet rm vanity
of 2 5/21 /2021, 9:00 AM