Loading...
REVIEWED BLD2021-0708+Interior_Lighting_Summary+5.24.2021_11.23.42_AM+2213021refox https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Administered by: @2021 NEEA, All rights reserved Project & Applicant Information Project Title MTI Physical Therapy Clinic - Edmonds - 2018 WSEC For Building Department Use: Date: May 21, 2021 Project Address 21616 76th Ave West 102 Edmonds, WA 98026 Applicant Name David Sova Applicant Phone 206-617-9010 Applicant Email david@dsdaa.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 2,675 General Project Types Alteration New Building or Addition Lighting Scope 9 9 p Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 2,675 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description Interior alterations to an existing medical office Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Alteration Interior Lighting less than 50% replaced No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Project Title MTI Physical Therapy Clinic - Edmonds - 2018 WSEC Date May 21, 2021 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (less than 50% replaced) Compliance Verification COMPLIES Interior Lighting Power Allowance Space Type Existing Lighting Wattage Prior to Alteration Total Watts Allowed Proposed Lighting Total Watts By Building Area Compliance Status Existing Lighting 2,484 2,484 Proposed Lighting Power Density- Spaces with less than 50% fixtures replaced Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer 2x4 38 60 2,280 Recessed downlight 6" recessed can light 10 18 180 Task lighting sconce 1 24 24 Proposed Total LPD 2484 Project Title MTI Physical Therapy Clinic - Edmonds - 2018 WSEC Date May 21, 2021 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (less than 50% replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer 2x4 A1.2 LED Existing -to -Remain Fixture Description: of 2 5/21 /2021, 9:00 AM refox https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3 Recessed downlight 6" recessed can light A1.2 Compact Fluorescent Existing -to -Remain Fixture Description: Task lighting sconce A1.2 Compact Fluorescent Existing -to -Remain Fixture Description: toilet rm vanity of 2 5/21 /2021, 9:00 AM