FIR2021-0052+Fire_Sprinkler_Plan+5.26.2021_12.01.41_PM+22180721" TO SPRINKLERS SEE PLAN Ld Ld 00 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE 7 TOLOO #22 OR EQUAL LISTED FOR CPVC I CPVC SINGLE FASTENER STRAP TYPE HANGER HANGER DETAIL 1 No SCALE CPVC RISER SUPPORT NOTES RISERS SHALL BE SUPPORTED BY PIPE CLAMPS OR BY NANGERS LOCATED ON THE HORIZONTAL CONNECTION CLOSE TO THE RISER. CITY LISTED HANGERS AND CLAMPS SHALL BE USED VERTICAL LINES MUST BE SUPPORTED AT INTERVALS TO AVOID PLACING EXCESSIVE LOAD ON ANY FITTING AT THE LOWER END OF THE RISER. VERTICAL PIPING SHALL BE SUPPORTED AT EACH FLOOR OR AT 10' INTERVALS, WHICHEVER IS LESS SUPPORT CAN BE ACHIEVED BY USING RISER CLAMPS OR DOUBLE BOLT PIPE CLAMPS LISTED FOR THIS SEfRNCE. DO NOT USE RISER CLAMPS WHICH SQUEEZE THE PIPE OR DEPEND ON COMPRESSION FOR SUPPORT. HANGERS AND STRAPS SHALL NOT COMPRESS. DISTORT. CUT OR ABRADE THE PIPING AND SHALL ALLOW FOR FREE MOVEMENT OF THE PIPE TO COMPENSATE FOR THERMAL EXPANSION AND CONTRACTION OF CPVC PIPE AND FITTINGS. 2' 4' 6' 8' 10' 12' 14' 16' 18' HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE jACCEPT3ABLE 7 TOLOD JT OR EQUAL I LISTED FOR OPVC CPVC DOUBLE FASTENER STRAP TYPE HANGER FASTENS TO EDGE HANGER DETAIL 2 No SCALE SUPPORT SPACING "L-(f� CPVC SDR 13.5 (SOURCE - CENTRAL SPRINKLER L) TEMP F 3/4- 1- 1-1/4' 1-1/2' 2- 2-1/Y 3- 73' 5-1/2 8 8-1/2 7 8 9 10 NOTE FOR EXPOSED INSTALLATIONS, LISTED SUPPORT DEVICES SHALL BE USED WHICH MOUNT THE PIPING DIRECTLY TO THE CEILING OR SIDE WALL. VISQUINE VAPOR BARRIER AND BATT INSULATION OVER PIPING TYPICAL IN COLD AREAS 17 - 7 1 /2" HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE ® TOLOD C 4 EQUAL LI51FD � CPVC CPVC DOUBLE FASTENER STRAP TYPE HANGER FASTENS TO FACE HANGER DETAIL 3 No SCALE SUPPORT SPACING DISTANCE CPVC SDR 13.5 WITH AN IN LINE SPRINKLER HEAD DROP TEE (SOURCE - CENTRAL SPRINKLER TABLE M) NOMINAL PIPE SZE LESS THAN 1OOPSI MORE THAN ,OOPS 3/4' 4' 3' 1. 5' 4' 5' NOTE: BRANCH LINES SHALL BE BRACED AT A DISTANCE FROM A TEE OR ELBOW TO PREVENT LIFT OF SPRINKLERS AS SHOWN IN TABLES M AND N F�Tr� 1�1-��I 1���1r1 n ��•���m CDDIhIVI DR Al ARI►II RDI 1 TOLCO FIG. 25 SURGE RESTRAINER TYPE 1 - FOR 1- AND 1-1/4: PIPE AND HANGER ® TYPE 2 - FOR 1-1/2- AND 2' PIPE AND HANGER TOLCO FIG. 25 IS DESIGNED To BE USED 9MLY WITH TOLCO BIND HANGERS FIG. 200 AND NFPA TO RESTRAIN THE UPWARD MOVEMENT OF PIPE AS IT OCCURS DURING SPRINKLER HEAD ACTIVATION OR SEISMIC ACTIVITY SURGE RESTRAINER FOR STEEL OR CPVC PLASTIC PIPE HANGER DETAIL 4 No SCALE SUPPORT SPACING DISTANCE CPVC SDR 13.5 TO AN END LINE SPRINKLER HEAD DROP ELBOW (SOURCE - CENTRAL SPRINKLER TABLE N) NOMINAL PIPE SIZE LESS THAN 1OOPS MORE THAN 100PSI 3/4- 9' 8- 1. 1'0- 9- 1-1/$ 1'4- I'D- 1-1/Y 2' 1'0- pVc CUT PERPENDICULAR CuNG \ TO SEAT CUT ABOVE SEAT SIDE VIEW FIELD MODIFICATION FOR RISER COLLAR FOR VERTICAL USE RISER CLAMP OR OTHER APPROVED SUPPORT TO STRUCTURE MODIFIED COUPLING GLUED TO EXTERIOR OF CPVC RISER NCTE- 1 SNUG TO CPVC PIPE BUT DO NOT DISTORT OR COMPRESS CPVC COUPLING MODIFICATION FOR VERTICAL RISER SUPPORT CPVC RISER SUPPORT DETAIL NO SOME GENERAL NOTES: DESIGN IS PER NFPA 13—D & EDMONDS AUTHORITY ALL HEADS ARE LISTED RESIDENTIAL SPRINKLERS FREEZE PROTECTION FOR ALL PIPING BY OWNER ALL ELECTRICAL WIRING BY OWNER ALL CPVC PIPE TO BE CONCEALED IN FLOOR, WALL OR TRUSS SPACE STEEL PIPE CAN BE EXPOSED PIPE SPRINKLER SPACING NOTE: VIKING VK 494, K=4.9 CONCEALED PENDENT SPRINKLERS ARE USED WITH 7 PSI END HEAD PRESSURE AND 13 GALLONS PER MINUTE. 16'X16' MAXIMUM SPACING. HEADS CAN BE NO CLOSER THAN 8'-0" BETWEEN SPRINKLERS AND 8-0 MAXIMUM MAXIMUM OFF ANY WALL. DATE REVISIONS DESCRIPTION BY SPRINKLER SYMBOLS SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL QQ 21 PEND WHITE 155 4.90 1 /2" VK494 VIKING VK494 ® 1 PEND WHITE 175 4.90 1 /2" VK494 VIKING VK494 22 TOTAL SPRINKLERS SIMILAR HOUSE SECTION 1 /4-'=1 "-O-' Approved by Fire 06/03/2021 A F M l<—/-F�tterer Approved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System drain(s) required at riser and must drain to the exterior. If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Systems require signage IAW NFPA 13D. Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater the 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When fuel fired equipment is present on covered decks or porches, or living space above, at least one quick -response intermediate temperature sprinkler shall be installed above the equipment or area under living space. All fuel fired appliances, except attics if above all living areas. Vertical back flow preventer must be tested annually. Strongly recommend system be monitored by fire alarm M FIRE PROTECTION LLC 20607 94TH AVE EAST GRAHAM, WA 98338 253- 315- 9266 t2" PV UNDERGROUND BY OTHERS ISTED VERTICAL BACKFLOW PREVENTOR ISER ASSEMBLY & DRAIN WITH FLOW SWITCH '0 SPRINKLERS ;TRIC ALARM BELL FOR SPRINKLERS =STIC OUTLET 1" SPRINKLER RISER IN RISER ROOM RISER ELEVATION NO SCALE ---------------------- WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Ranfferi Morales -Mora 2901-0209-AG Level 1 M Fire Protection System, LLC v. MFIREFP810B 5-26-21 13' � yfyip Signat re ��Expires 1 SEAVIEW AFH 8120 187TH ST SW EDMONDS, WA 98026 F I R2021-0052 RECEIVED May 27 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIRE SPRINKLER PLAN PERMIT NO. CONTRACT NO. APPROVAL DRAWN BY SCALE DATE REVISED NICK 1 /8" = 1'—O" 05/24/2021 FP1of1