FIR2020-0070+Fire_Sprinkler_Equipment_Specification_Sheets+7.21.2020_1.38.55_PMES-A-2000B Series 2000B Double Check Valve Assemblies Sizes: 1/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1/2" — 2" (15 — 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" — 1 " (15 — 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 2'/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 Job Name Job Location Engineer Approval A A M E S FIRE & WATERWORKS C.. I 2" 2000B HC (50mm) % so, &W W 2000B (20mm) Series 2000B Double Check Valve Assemblies shall be installed at referenced cross - connections to prevent the backflow of polluted water into the potable water supply. Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals Assif", H55E ��® N C Q. US c us 1015 B64.5 (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 23'/2" (594mm) (ON) DIMENSIONSSIZE in. mm A in. mm in. B mm C in. mm F in. mm G in. mm H in. mm in. I mm lbs. kgs. '/2 15 10 254 4% 117 2'/16 62 5 127 3% 85 26/16 59 2'/16 52 4.5 2 3/4 20 11 % 282 4 102 3'/s 79 63/ 6 157 V16 87 2% 54 16/ 6 33 5 2.3 1 25 13'/4 337 1 51/8 130 1 4 102 1 7'/2 191 1 3% 85 11'/6 43 111/6 43 1 12 5.4 1'/4 32 16% 416 5 127 36/6 84 91h 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/8 124 31h 89 93/4 248 51Y16 148 3'/s 79 2"/6 68 15.86 7.2 2 50 19'/2 495 6'/4 159 4 102 13% 340 6'/8 156 37/6 87 2"/16 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) y 83 12 0 69 10 m 55 8 41 6 N 28 4 aNi 14 2 a 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■■ 69 1 ��■ ����■ IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIII�� 41 ��■ ����■ 14 ;ice■ ����■ kPa psi 11/4 ° (32MM) 96 14 A 83 12 N o 69 10 y 55 8 7 41 6 d 28 4 14 2 a- 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 83 12 H 69 10 0 55 8 0 41 6 3 28 4 d14 2 n n LL AP 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate 0 kPa psi 11I (25mm) o y 110 16 A J 0 83 12 i m 69 10 W 7 55 8 H 41 6 28 4 I1 I1 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate .AA A M E S FIRE & WATERWORKS A Watts Water Technologies Company ES-A-200013 1322 pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 2" (50mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm OP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate www.amesfirewater.com aOW Loi,I,C o R II 11. USA: Backflow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 0 2013 Ames Fire & Waterworks tqC00 Model RM-1 Riser Manifold Commercial and Residential General Description The TYCO commercial and residential Model RM-1 Riser Manifold provide the necessary waterflow alarm, pres- sure gauge, alarm test orifice, drain, and sight glass equipment in a single assembly for use in NFPA 13 com- mercial sprinkler systems and in NFPA 13D/13R residential sprinkler systems as follows: NFPA 13* • 1-1/2 in. (DN40) Male Thread x Female Thread • 2 in.-6 in. (DN50-DN150) Groove x Groove NFPA 13D • 1 in. (DN25) Female Thread x Female Thread NFPA 13R • 1-1/2 in. (DN40) Male Thread x Female Thread • 2 in. (DN50) Groove x Groove Although the Riser Manifold described in this techni- cal data sheet is intended for NFPA 13 sprinkler sys- tems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 2.8K or 4.2K is acceptable. The variety of sizes and grooved end connections allow cost effective and easy transition to check valves, control valves, and system piping. The Model RM-1 Riser Manifolds may be installed either horizontally (flow switch on top) or vertically (flow going up) orientation, for both single sprinkler rises and floor control in high-rises. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Optional Pressure Relief Kits feature a 175 psi pressure relief valve and trim components for convenient integration into commercial and residential riser manifold assemblies. The pressure relief valve, installed in manifold assemblies above the nor- mally closed test and drain or drain valve, automatically bleeds system pressure exceeding 175 psi through a flexible hose connected to the mani- fold drain outlet (Ref. Figure 5), reduc- ing system pressure to 175 psi. NOTICE The Model RM-1 Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Approvals UL and ULC Listed FM Approved Listed by California State Fire Marshall Maximum Working Pressure 300 psi (20,7 bar) Test Orifice 1 in.-3 in. (DN25-DN80) Manifolds: 2.8K 4in.-6 in. (DN100-DN150) Manifolds: 4.2K Finish Red Painted Worldwide I www.tyco-fire.com Contacts Page 1 of 8 AUGUST 2018 TFP963 TFP963 Page 2 of 8 Nominal Nominal End Nominal Dimensions Drain Riser Connections Inches Size Size (mm) Inches Inches (DN) (DN) Inlet Outlet A B C D E F G H 1-1/2 Thread Thread 10 15-1/2 2-1/4 5-5/8 8-3/8 15 4-3/8 1-1/4 (40) MNPT FNPT (254) (394) (57) (143) (213) (381) (111) (32) 2 Groove Groove 13 18 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 (50) (330) (457) (53) (143) (213) (388) (111) (32) 2-1/2 Groove Groove 13 18-1/16 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 (65) (330) (460) 1 (53) (143) 1 (213) (388) 1 (111) (32) 3 Groove Groove 13 18-1/16 2-1/16 5-7/8 8-5/8 15-3/4 4-3/8 1-1/4 (80) (330) (460) (53) (150) (219) (400) (111) (32) 4 Groove Groove 13 20-1/4 4-1/4 6-3/4 10-3/4 18-3/8 5-3/16 2 (100) (330) (514) (108) (172) (273) (467) (132) (50) 6 Groove Groove 13 20-1/4 4-1/4 7-3/4 11-3/4 21 6-3/4 2 (150) (330) (514) (108) (197) (300) (533) (172) (50) FIGURE 1 MODEL RM-1 COMMERCIAL RISER MANIFOLDS 1-1/2-6INCH (DN40—DN150) NO DESCRIPTION P/N 1 300 psi/2000 kPa Water Pressure Gauge. .90050001 2 Test and Drain Valve, Model TD-1: 1-1/2-3 Inch (DN40-DN80) Size Manifolds, 1-1/4", 2.81K Orifice..... A61 G0420 4-6 Inch (DN100-DN150) Size Manifolds, 2", 4.2K Orifice........ A61 G0601 3 Flow Switch, VSR-M: 1-1/2"(DN40)......... 91144815 2"(DN50)............ 91144802 2-1/2"(DN65)......... 91144825 3"(DN80)............ 91144803 4"(DN100)........... 91144804 6" (DN150) ...........91144806 4 Field Replaceable Retard/Switch ......... 91144800 TFP963 Page 3 of 8 3-7/8" (100 mm) OPTIONAL PRESSURE RELIEF TRIM 1" NPT CONNECTION (FEMALE) 2FF10" (254 mm) �� 1 2-1/2" NPT ll (64 mm) DRAIN 1 1V 0 (280 mm) NO DESCRIPTION P/N 1 300 psi/2000 kPa Water Pressure Gauge. .90050001 2 Ball Valve, 1" (DN25)....97111603 3 Flow Switch, VSR-M, 1"(DN25)............ 91144801 4 Field Replaceable Retard/Switch ......... 91144800 3-3/4" —X (96 mm) 1 " NPT 3, 4 4-5/8" (FEMALE) (118 mm) 10-1 /8" (257 mm) FIGURE 2 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1 INCH (DN25) OPTIONAL PRESSURE 1 RELIEFTRIM 1 NPT CONNECTION N (FEMALE) 10" (254 mm) 2 7/16" (11 mm) 13-1/4" (337 mm) i 3-7/8" 3-7/8" 3, 4 (100 mm) 1 (100 mm) 1-1/2" NPT NPT 4-3/4" (MALE) DRAIN (121 mm)~ 11-3/8" (290 mm) FIGURE 3 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1-112 INCH (DN40) NO DESCRIPTION P/N 1 300 psi/2000 kPa Water Pressure Gauge. . 90050001 2 Ball Valve, 1" (DN25).... 97111603 3 Flow Switch, VSR-M, 1-1/2"(DN40)......... 91144815 4 Field Replaceable Retard/Switch ......... 91144800 TFP963 Page 4 of 8 1 2'' (GROOVED) OPTIONAL PRESSURE O RELIEF TRIM CONNECTION T r 16' 0 (406 mm) NO DESCRIPTION P/N 13" / 1 300 psi/2000 kPa (330 mm) Water Pressure Gauge .. 90050001 2 Ball Valve, 1" (DN25)....97111603 3 Flow Switch, VSR-M, 2"(DN50)............ 91144802 2 4 Field Replaceable C Retard/Switch......... 91144800 1/2" (13 Imm) I 3-7/8" 4-1/8"' 3,4 (100 mm) V. (105 mm) 2" NPT 5" (GROOVED) DRAIN ~(127 mm)~ 11-7/8" _ (300 mm) FIGURE 4 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 2 INCH (DN50) Manifold Installation TYCO Model RM-1 Riser Manifold must be installed in accordance with this section. The Model RM-1 Riser Manifold may be installed either horizontally (flow switch on top) or vertically (flow going up). The inlet of the Riser Manifold may be con- nected directly to a shut-off control valve. Notes: Where applicable pipe thread sealant is to be applied sparingly. Use of a non -hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Provisions for an alarm test flow on Residential Models must be made. The alarm test flow is to be through an orifice having a flow capacity equal to or smaller than the smallest orifice sprinkler in the system. One of two options can be considered. The first option is to temporarily install a test orifice in the outlet of the drain line prior to performing the alarm test. The second option is to install an Inspec- tor's Test Connection downstream of the Waterflow Alarm Switch. Step 1. Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable. Step 2. Connect the drain line and on commercial manifolds set the Model TD-1 Test and Drain Valve to the OFF position or on residential manifolds close the drain valve. Step 3. Refer to Figure 6 for wiring guidance. All wiring must be performed in accordance with the authority having jurisdiction and/or the National Electri- cal Code. Step 4. Refer to Figure 5 for Optional Pressure Relief Trim installation. Step 5. Place the system in service by filling the system with water. When filling the system, partially open the control valve to slowly fill the system. Filling the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6. Secure all supply valves open. TFP963 Page 5 of 8 Commercial Riser Manifolds NO DESCRIPTION P/N 1 Pressure Relief Valve, 175 psi, 1/2" NPT.......... 1001184-01 2 112" x Close Nipple ........ 1001023-01 3 Flexible Hose: 1-1/2-3 Inch (DN40-DN80) Size Manifolds, 1/2" x 24.................. 1001266-02 4-6 Inch (DN100-DN150) Size Manifolds, 1/2"x 30..................1001266-01 4 Figure 323 Reducing Tee, Grooved x NPT Threaded: 1-1/2-3 Inch (DN40-DN80) Size Manifolds, 1-1/4" x 1-1/4" x 1/2 3231305GS 4-6 Inch (DN100-DN150) Size Manifolds, 2" x 2" x 112............... 3232005GS 5 Figure 577 Rigid Grooved Coupling: 1-1/2-3 Inch (DN40-DN80) Size Manifolds, 1-1/4 ..................... 57713AGCP 4-6 Inch (DN100-DN150) Size Manifolds, 2" ...................... 57720AGCP MODEL RM-1 COMMERCIAL RISER MANIFOLD Residential Riser Manifolds NO DESCRIPTION P/N 1 Pressure Relief Valve, 175 psi, 1/2" NPT.......... 1001184-01 2 1/2" x Close Nipple, Qty 2 ... 1001023-01 3 Flexible Hose, 1/2" x 16" .... 1001266-03 4 Figure 815 Threaded Reducing Tee, 1" x 1" x 1/2" NPT ......... 1001259-07 5 1" x Close Nipple .......... 1001025-01 MODEL RM-1 RESIDENTIAL FIGURE 5 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLDS OPTIONAL PRESSURE RELIEF TRIM INSTALLATION Optional Pressure Relief Trim Installation Model RM-1 commercial and resi- dential riser manifold assemblies are designed to accommodate an optional pressure relief valve and trim compo- nents (Ref. Figure 5). Optional pressure relief trim must be installed in accordance with the follow- ing procedures. Notes: For assembly in Riser Manifolds installed and in service, verify the fire protection system is de -pressurized and drained. Close the system supply control valve, set commercial manifold test and drain valve to DRAIN or open residential drain valve to relieve resid- ual pressure and drain system. Make certain that drainage water will not cause any damage or injury. Refer to Care and Maintenance section for other requirements when closing a fire protection system control valve and placing system in service. Apply thread sealant or TEFLON tape on all threaded connections, with the exception of internally sealed flexible hose connections. Commercial Manifolds Refer to Figure 1 for commercial riser manifold features and Figure 5 for pres- sure relief trim components described in this procedure. Step 1. Remove 1/2 in. pipe plug from manifold tee. Inspect exposed female tee threads, remove thread sealant remnants or debris as necessary. Step 2. Install Pressure Relief Valve (1) in manifold tee, orienting valve outlet port perpendicular to and facing away from manifold body. Step 3. Install 1/2 in. x Close Nipple (2) in pressure relief valve outlet port. Step 4. Disconnect drain piping from grooved outlet of manifold TD-1 test and drain valve as applicable and install Figure 323 Grooved Reducing Tee (4) on valve outlet by securing with Fig- ure 577 Grooved Coupling (5), align- ing tee threaded branch outlet parallel with pressure relief valve outlet port. Reconnect drain piping to Figure 323 tee drain outlet as necessary. Note: Refer to Technical Data Sheet G901 for Figure 577 Grooved Coupling installation and assembly instructions. Step 5. Install Flexible Hose (3) by threading female ends onto 1/2 in. x close nipple installed on relief valve outlet port and onto Figure 323 reduc- ing tee branch outlet. Note: Assure Flexible Hose is not sus- ceptible to being caught or snagged by other moving equipment. Residential Manifolds Refer to Figures 2, 3 or 4 for residen- tial riser manifold features and Figure 5 for pressure relief trim components described in this procedure. Step 1. Remove 1/2 in. pipe plug from manifold tee. Inspect exposed female tee threads, remove thread sealant remnants or debris as necessary. Step 2. Install Pressure Relief Valve (1) in manifold tee, orienting valve outlet port perpendicular to and facing away from manifold body. Step 3. Disconnect drain piping from threaded outlet of manifold drain valve as applicable and install 1 in. x Close Nipple (5) in valve outlet. Step 4. Install Figure 815 Reducing Tee (4) onto 1 inch x close nipple, align- ing tee branch outlet parallel with pres- sure relief valve outlet port. Reconnect drain piping to Figure 815 tee drain out- let as necessary. Step 5. Install 1/2 in. x Close Nipples (2) in pressure relief valve outlet port and in Figure 815 reducing tee branch outlet. Step 6. Install Flexible Hose (3) by threading female ends onto 1/2 in. x close nipples installed on relief valve outlet port and Figure 815 reducing tee branch outlet. Note: Assure Flexible Hose is not sus- ceptible to being caught or snagged by other moving equipment. TFP963 Page 6 of 8 UNINSULATED LOOPED SECTION SINGLE CONDUCTOR CLAMPING \� PLATE \ TERMINAL IMPROPER CONNECTION METHOD WIRE NUT NEUTRAL WHITE �w U� SWITCH TERMINAL CONNECTIONS CLAMPING CAUTION: PLATE An uninsulated section of a TERMINAL single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. LOCAL WIRE NUT AUDIBLENISUAL ANNUNCIATOR TOR WHITE / \ BLACK BLACK (LINE/HOT) C CONTACT RATINGS: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC J ISO Owz J O m Z O Z OQQ ( NO NC COM I i NC SEVERED STRIPPED ENDS SEPARATE CONDUCTORS INCOMING OUTGOING PROPER CONNECTION METHOD FIRE PANEL OR ADDRESSABLE MODULE NOTE: When connecting to a UL Listed control panel, use panel resistor rating for circuit supervision NOTE: For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm Switch has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. FIGURE 6 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLD WIRING GUIDANCE TFP963 Page 7 of 8 DRAIN O 07 0 1O 00 O� 0ul Oo 00 00 5AAa LS� Nld11a OFF MARKING TEST MARKING DRAIN MARKING ON HANDLE ON HANDLE ON HANDLE POSITIONED POSITIONED POSITIONED O ON DETENT ON DETENT ON DETENT O ODEL TESTA Dt DRAIN VALVE O 4DRAIN o �" Oo ����SIGHT FLOW O O O O-- CONNECTION SET TEST DRAIN FRONT CONDITION CONDITION CONDITION VIEW FIGURE 7 MODEL RM-1 COMMERCIAL RISER MANIFOLD TD-1 TEST AND DRAIN VALVE OPERATION Care and Maintenance TYCO Riser Manifolds RM-1 must be serviced and maintained in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the effected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (e.g., NFPA 25), in addi- tion to the standards of any authority having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Note: No attempt is to be made to repair any Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser mani- fold must be replaced. The alarm/flow test procedure will result in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. The following inspection procedure must be performed as indicated, in addition to any specific requirements of the NFPA, and any impairment must be immediately corrected: Alarm/Flow Test Procedure Step 1. Place the Model TD-1 Test and Drain Valve in the TEST position (Ref. Figure 7). On residential assemblies without a test orifice, temporarily install a test orifice in the drain outlet and fully open the Drain Valve. Make certain that drainage water will not cause any damage or injury. Step 2. Verify operation of associated alarms. Step 3. Verify that the residual (i.e., flowing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 4. Close the Drain Valve on the Residential models and the Test and Drain valve on commercial models. Step 5. Verify that the static (i.e., not flowing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. TFP963 Page 8of8 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Riser Manifolds Specify: Size (specify) Connection Type (specify inlet x outlet) Model RM-1 Riser Manifold, P/N (specify): Commercial 1-1/2 in. (DN40) MT x FT .............. 40551 2 in. (DN50) G x G ................... 40601 2-1/2 in. (DN65) G x G ................ 40611 3 in. (DN80) G x G ................... 40621 4 in. (DN100) G x G .................. 40651 6 in. (DN150) G x G................... 40661 Residential 1 in. (DN25) FT x FT .................. 40671 1-1/2 in. (DN40) MT x FT .............. 40571 2 in. (DN50) G x G ................... 40591 Optional 175 psi Pressure Relief Kit Specify: Pressure Relief Kit, Model RM-1 Riser Manifold, (specify Commer- cial or Residential application), (specify size range), P/N (specify): Commercial 1-1/2 in. — 3 in. (DN40—DN80) 40721 4in. —6 in. (DN100—DN150) 40731 Residential 1 in.-2 in. (DN25—DN50) .............. 40711 Replacement Parts Specify: Model RM-1 Riser Manifold (specify part description), P/N (specify from Figures 1, 2, 3, 4 or 5) 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 m 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON Is a registered tratlemark of DuPont Johnson 01,to Controls POTTER The Symbol of Protection (H-.-� (@ <�a> A * These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. BELLS PBA-AC & MBA -DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -401 to 150°F (-401 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-341 to 661C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC MBA-6-12 1750070 .12A 85 76 8 (200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6 (150) 24VDC MBA-6-24 1750100 .06A 87 77 8 (200) 24VDC MBA-8-24 1750110 .06A 91 79 10 (250) 24VDC MBA-10-24 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC I PBA12010 1 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. AWARNING A16. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.coni PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 1 OF 2 01/13 CP� POTTER The Symbol of Protection BELLS PBA-AC & MBA -DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS 10" WHITE (IN) WHITE (OUT) 8" I FROM CONTROL (200) 6" i I PANEL OR (150) I PRECEDING BELL I I BLACK (R _ (IN)CBLACK IOj CAUTION: 211/16" WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. (68) DWG# 776-1 NOTES: 1. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS. Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance 3388" - (86) 4 1/4" (108) DWG# 776-2 3 3/8" 5" (86) (127) DWGtt 7763 Installation 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 Page 1 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to Y2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS e@us UL Listed (C-UL-US-EU): Category VKKW eo Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric 4 K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 16.06.27 Rev 16.1 (New product, new page) Page 2 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = MA, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031 *** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/2' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number' Number' Number' Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 135 °F (57 °C) 1 13504 1 13642 1 15394 1 Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. s Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F_012116 16.06.27 Rev 16.1 Page 3 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number' SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,s Spacing Ceiling Type Ft. 155 T (68 °C),175 T (79 °C), 200 T (93 °C) c UL us 4 Ft. X Ft. (m) (m X m) Temperature Rated Sprinklers EU 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Refer to Figure 2 Concealed with Cover Plate See Footnotes T10, & 11 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Assembly. See Footnote 9. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. ° Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. e Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. Cover Temperature Rating is 135 °F (57 °C). Cover Part No. 135041, 13642' (large diameter), or 15394' (square cover plate). e Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 0 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 9. " C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F_012116 16.06.27 Rev 16.1 Page 4 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listina Reauirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 16.06.27 Rev 16.1 Page 5 of 5 N4 I [a® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1/2" (15 mm) NPT 2-9/16" (65 Ok mm) Maximum 2-1/16" (52 mm) Minimum -000 NEW LAE c� �— 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13116" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C US 7-0 a �2 O c� v� O VIKING0. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers - -I . - \- . .... ., Figure 4: Square Cover Assembly 15394 Form No. F_012116 16.06.27 Rev 16.1 (New product, new page)