Loading...
FIR2020-0070+Fire_Sprinkler_Plan+7.21.2020_1.39.05_PMApproved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System drain(s) required at riser and must drain to the exterior Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater the 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When fuel fired equipment is present on covered decks or porches, at least one quick -response intermediate temperature sprinkler shall be installed above the equip nent. All fuel fired appliances, except attics if above all living areas. Approved DFM17"5 07/2i/20 Composite Wood Joist \ NB-1 Headset Mounting Bracket and No Block Hanger Offset Hanger Headset Gyp. Board Ceiling CPVC HANGER DETAIL "A"- Wood Joist \ NB-2 Headset Mounting Bracket and No Block Hanger Offset Hanger Headset / Gyp. Board Ceiling L CPVC HANGER DETAIL "B" ALERT FOR CONTRACTORS & ALL TRADES: THIS PROJECT USES BLAZEMASTER PIPE & FITTINGS THAT ARE SPECIFICALLY FOR FIRE SPRINKLER SYSTEMS. THEY ARE MADE FROM A SPECIALTY THERMO PLASTIC KNOWN AS POST CHLORINATED POLYVINYL CHLORIDE. (CPVC) DO NOT USE OR PLACE IN CONTACT ANY MATERIAL THAT ARE INCOMPATIBLE WITH CPVC SUCH AS PETROLEUM OR SOLVENT BASED SEALANT, FIRE STOP INSULATION, ETC. PLEASE REFER TO LUBRIZOL FBC SYSTEM COMPATIBILITY PROGRAM FOR GUIDANCE REGARDING CHEMICAL COMPATIBILITY OF CERTAIN MATERIALS GO TO BLAZEMASTER.COM TOR 90 ELBOW TO SYSTEM 1" TYCO MODEL 13D RISER MANIFOLD W/: (1) DRAIN AND TEST (2) FLOW SWITCH SPARE HEAD CABINET ^(3) PRESSURE GAUGE FsotWORK8 W/ HEADS & WRENCH(4) SIGNS ON BODY FSI 3 psi loss for (Alarm Bell Optional) O flow switch 1' AMES MODEL 2000D DOUBLE CHECK VALVE LNITECH TO DOMESTIC SUPPLY Riser Detail Building Department Work FIRE SPRINKLER Address 806 CARY RD Owner KETNER Approved Date Building Official Permit Number FIR2020-0070 1 " WATER METER WMI WMO If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Flow Through systems require signage IAW NFPA 13D. Coverage required to the following areas: Lower Floor Plan 1/4 11 -1-0 11 RECEIVED Jul 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT \IG. 1ENTS. -D. FIRE DEPT. 13D r VMS IM4100p ST11" 0RTiF1CATE OF 00WETENOT PYRE rn*TECTwm SritwKLER SYSTEM! i Khosrow (David) Farahanl C i 7325.0195-C Level N Nor -Tech Fire Protection, Inc. C NORTEFPO 6 Si glaroa sp�� 1�181128 1 ------------------- WATER FLOW INFORMATION: STATIC: xx PSI RESIDUAL: 20 PSI FLOW: xx GPM APPROXIMATE HYDRANT ELEVATION (ft) xxx PRESSURE ZONE:XXX FLOW AVAILABLE @ 20 PSI, xxx GPM PITOT READING: ? TEST DATE: XXX TEST LOCATION: XXX WATER DEPARTMENT JURISDICTION: XXX HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS — LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH Carlisle Classic Homes NORTH PROJECT Kentner Residence ADDRESS: 806 Cary Road CITY Edmonds, WA 98020 SPRINKLERS SYMB. MODEL ID # THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.S Snohomish CO. Fire 425-551-1200 2. 7353 15th Ave NW VIKING RESIDENTIAL SPRINKLER ® VK494 20759 I /z' 4,9 BRASS WHITE CONC. 200° 1 1 3. Seattle, WA 98117 A 4. 206-782-7070 TITLE: FIRE SPRINKLER PLAN WATER DEPT. ARCHITECT xxx " ";,,,,,,�,'' ® _ ' ® NOR —TECH FIRE PROTECTION INC. DESIGNED: O.F. DATE: 7/20/20 corirRAcr # 2007-3370 20030 NE Novelty Hill Road —Box B REDMOND, WA FAX: 25 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 ADDRESS xxx CITY CITY xxx SHEET NO. FP-1 of 3 TOTAL SPRINKLERS THIS DRAWING 11 PHONE PHONE xxx SCALE: 1/4°°=1'-0" -ICU —ICU M 22 ALERT FOR CONTRACTORS & ALL TRADES: THIS PROJECT USES BLAZEMASTER PIPE & FITTINGS THAT ARE SPECIFICALLY FOR FIRE SPRINKLER SYSTEMS. THEY ARE MADE FROM A SPECIALTY THERMO PLASTIC KNOWN AS POST CHLORINATED POLYVINYL CHLORIDE. (CPVC) DO NOT USE OR PLACE IN CONTACT ANY MATERIAL THAT ARE INCOMPATIBLE WITH CPVC SUCH AS PETROLEUM OR SOLVENT BASED SEALANT, FIRE STOP INSULATION, ETC. PLEASE REFER TO LUBRIZOL FBC SYSTEM COMPATIBILITY PROGRAM FOR GUIDANCE REGARDING CHEMICAL COMPATIBILITY OF CERTAIN MATERIALS GO TO BLAZEMASTER.COM ..■yA■.. ■ ■yy. ■ ■ AN ■ 1/4II=11-011 GENERAL NOTES: 1 . THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. A TOTAL OF (2) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 INSTALLATION TO CONFORM WITH NFPA #13D & S. SNOHOMISH CO. FIRE DEPT. 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. 4 ALL FITTINGS TO BE CPVC U.N.O. o 5 ALL PIPE TO BE CPVC U.N.O. NFPA 13 D 6 PROTECTION OF HEADS FROM PAINT BY OTHERS. 7 . ALL ELECTRICAL WIRING BY OTHERS. RECEIVED Jul 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT !nnw"wMMMM M nMMM=wEMMMM MMN==q r *""MNO'TON R RZE awTwocivrE OF COWETEMMOY FIXE PROTECTIOM EPRSlMI1ILER SYS7EMs i Khosrow (David) FarahaniCD is 17325.0195-C Level N Nor -Tech Fire Protection, In*. C:) NORTEFPO $ r r roa sp 1 Z181 �—.a WATER FLOW INFORMATION: STATIC: xx PSI RESIDUAL: 20 PSI FLOW: xx GPM APPROXIMATE HYDRANT ELEVATION (ft) xxx PRESSURE ZONE:XXX FLOW AVAILABLE @ 20 PSI, xxx GPM PITOT READING: ? TEST DATE: XXX TEST LOCATION: XXX WATER DEPARTMENT JURISDICTION: XXX HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS - LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH Carlisle Classic Homes NORTH PROJECT Kentner Residence ADDRESS: 806 Cary Road CITY Edmonds, WA 98020 SPRINKLERS SYMB. MODEL ID # THREAD "K" FINISH ESCUTCH. TYPE DEGREE Q 1.S Snohomish CO. Fire 425-551-1200 7353 15th Ave NW VIKING RESIDENTIAL SPRINKLER ® VK494 20759 1TY. /z' 4,9 BRASS WHITE CONIC.2. 200° 16 3. Seattle, WA 98117 A 4. 206-782-7070 TITLE: FIRE SPRINKLER PLAN WATER DEPT. ARCHITECT xxx "'lull°""""�,'' ® e ' ® NOR -TECH FIRE PROTECTION INC. DESIGNED: D.F. DATE: 7/20/20 CONTRACT # 2007-3370 20030 NE Novelty Hill Road -Box B REDMOND, WA FAX: 25 98053 425-898-9111 FAX: 425-898-7772 LICENSE N0. NORTEFP051P6 ADDRESS xxx CITY CITY xxx SHEET NO. FP-2 of 3 TOTAL SPRINKLERS THIS DRAWING 16 PHONE PHONE xxx SCALE: 1/4°°=i'-o" Lf7 ALERT FOR CONTRACTORS & ALL TRADES: THIS PROJECT USES BLAZEMASTER PIPE & FITTINGS THAT ARE SPECIFICALLY FOR FIRE SPRINKLER SYSTEMS. THEY ARE MADE FROM A SPECIALTY THERMO PLASTIC KNOWN AS POST CHLORINATED POLYVINYL CHLORIDE. (CPVC) DO NOT USE OR PLACE IN CONTACT ANY MATERIAL THAT ARE INCOMPATIBLE WITH CPVC SUCH AS PETROLEUM OR SOLVENT BASED SEALANT, FIRE STOP INSULATION, ETC. PLEASE REFER TO LUBRIZOL FBC SYSTEM COMPATIBILITY PROGRAM FOR GUIDANCE REGARDING CHEMICAL COMPATIBILITY OF CERTAIN MATERIALS GO TO BLAZEMASTER.COM 12'-1' 29'-10" Upper Floor Plan 1/ II=11-011 � SLL// ATTI C FIRE SPRINKLER PIPE (ON WARM SIDE OF INSULATION). /_ INSULATION TRUSS AND GYPSUM WALL BOARD CEILING -SPRINKLER PPE IN THE ATTIC NO SCALE GENERAL NOTES: THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. A TOTAL OF (2) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 INSTALLATION TO CONFORM WITH NFPA #13D & S. SNOHOMISH CO. FIRE DEPT. 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. 4 ALL FITTINGS TO BE CPVC U.N.O. o 5 ALL PIPE TO BE CPVC U.N.O. NFPA 13 D 6 PROTECTION OF HEADS FROM PAINT BY OTHERS. 7 . ALL ELECTRICAL WIRING BY OTHERS. RECEIVED Jul 23 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Hydraulic Data AREA OF APPLICATION: I Exercise room NO. OF SPRINKLERS CALCULATED: 2� COVERAGE PER SPRINKLER: 16'x16' DESIGN DENSITY: 10.05 GPM & or per MFG listing TOTAL AREA OF DISCHARGE: 512 SF. MIN. GPM REQUIRED PER HEAD: 13 GPM TOTAL SPRINK DEMAND AT B.O.R. 26.3 GPM @ 42.3 PSI AVAILABLE AT THE B.O.R. 126.3 GPM @ 98.8 PSI !nnw"wMMMM M nMMM=wEMMMM MMN==q r %WPA" MOTON 1"Nal i I#RTIFRCATE OF 00WETEMMOr FARE PROTECTIOM EPRIs1MRLER SYRiT6Ms i Khosrow (David) Farahani O is 17325.0195-C Level N Nor -Tech Fire Protection, In*. C:) NORTEFPO $ r sp 1 Z181126 �-.a WATER FLOW INFORMATION: STATIC: 110 PSI RESIDUAL: 20 PSI FLOW: xx GPM APPROXIMATE HYDRANT ELEVATION (ft) xxx PRESSURE ZONE:XXX FLOW AVAILABLE @ 20 PSI, xxx GPM PITOT READING: ? TEST DATE: XXX TEST LOCATION: XXX WATER DEPARTMENT JURISDICTION: XXX HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS — LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH Carlisle Classic Homes NORTH PROJECT Kentner Residence ADDRESS: 806 Cary Road CITY Edmonds, WA 98020 SPRINKLERS SYMB. MODEL ID # THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.S Snohomish CO. Fire 425-551-1200 2. 7353 15th Ave NW VIKING RESIDENTIAL SPRINKLER ® VK494 20759 1 /z' 4,9 BRASS WHITE CONC. 200° 7 3. Seattle, WA 98117 A 4. 206-782-7070 TITLE: FIRE SPRINKLER PLAN WATER DEPT. ARCHITECT • - • NOR —TECH FIRE PROTECTION INC. DESIGNED: D.F. DATE: 77720 CONTRACT # 2007-3370 20030 NE Novelty Hill Road —Box B REDMOND, WASHINGTON 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 ADDRESS CITY SHEEP N0. FP-3 of 3 TOTAL SPRINKLERS THIS DRAWING 7 PHONE PHONE SCALE: 1/4"=1'-0"