APPROVED BLD BLD2021-0785+Architectural_Plan+6.9.2021_12.11.11_PM+2240543
�J EXISTING MAIN FLOOR PLAN PLAN NOTES 1.) ALL DIMENSIONS TO FAGS OF FRAM I N6. 2.) 6G TO VERIF'I' LOGATION OF EXISTING FRAM I N6 AND HEADERS. WALL TYPES: EXISTING WALL TO REMAIN NEW 2X6 WOOD STUD © 1611 O.G. WALLS WITH 1/2" GYPSUM WALLBOARD ON INTERIOR SIDE INSULATION PER GOVER SHEET Al _ EXISTING 2X4 WOOD STUD @ 1611 O.G. WALLS WITH 2X FURRING 1/2" GYPSUM WALLBOARD ON INTERIOR SIDE INSULATION PER COVER SHEET Al NEW 2X4 WOOD STUD @) 16" O.G. HALLS WITH 1/2" GYPSUM WALLBOARD ON EACH SIDE INSULATION PER COVER SHEET Al 050 SMOKE DETECTOR (HARD -HIRED H/ BATTERY BAGKUP) OcrtD GARBON MONOXIDE DETECTOR 0 EXHAUST FAN 1/411 = 11-011 PROJECT INFORMATION OWNER NAME: NATHAN & CHRISTINA MINEAR SITE ADDRESS: 9722 242ND PL SW, EDMONDS, WA 98020 TAX ACCOUNT#: 00450300001200 ZONING: RS-8 LOT AREA: 8,276 SF BUILDING HEIGHT: NO CHANGE FROM EXISTING LEGAL DESCRIPTION: FORSHEES FIRDALE VILLAGE 5 BILK 000 D-00 - LOT 12 GENERAL NOTES ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND ORDINANCES INCLUDING THE 2018 INTERNATIONAL RESIDENTIAL CODE WITH CITY OF EDMONDS AMMENDMENTS AS WELL AS THE 2018 WASHINGTON STATE ENERGY CODE. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. REFER TO DIMENSIONS AND NOTES FOR SIZES AND LOCATIONS; DO NOT SCALE DRAWINGS. DIMENSIONS ARE TO FACE OF STUD OR MASONRY WALL AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT EXISTING BUILDING (AS APPLICABLE) CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. SHORING AND BRACING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTUCTION AS REQUIRED BEFORE ANY STRUCTURAL MEMBERS ARE REMOVED OR BEFORE ANY NEW LOADS ARE ADDED UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE OR VEGETATION. WHERE NEW CONCRETE OR REINFORCED MASONRY ABUT EXISTING CONCRETE OR MASONRY, PROVIDE THREADED BARS INTO THREADED EXPANSION INSERTS TO MATCH AND LAP HORIZONTAL REINFORCING UNLESS NOTED OTHERWISE ON DRAWINGS. CONTRACTOR SHALL CHECK FOR ROT OR INSECT INFESTATION AT ALL WALLS, AREAS SHOWING WATER STAINS, AND ALL WOOD MEMBERS. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE ARCHITECT. OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES PROPOSED MAIN FLOOR PLAN ENERGY CODE NOTES REQUIREMENTS OF THE 2018 WASHINGTON STATE ENERGY CODE SHALL BE FOLLOWED. PRESCRIPTIVE ENERGY CODE COMPLIANCE CLIMATE ZONE 4C MARINE GLAZING U-VALUE, VERTICAL: MAX. ALLOWED: 0.30 GLAZING U-VALUE, OVERHEAD: MAX. ALLOWED: 0.50 DOOR U-VALUE: MAX. ALLOWED: 0.30 CEILING INSULATION: REQUIRED: R-49 VAULTED CEILING INSULATION: REQUIRED: R-38 ABOVE GRADE WALL INSULATION: REQUIRED: R-21 INTERIOR WALL BELOW GRADE: REQUIRED: R-21 EXTERIOR WALL BELOW GRADE: REQUIRED: R-10 FLOOR ABOVE UNHEATED SPACE: REQUIRED: R-30 SLAB ON GRADE: REQUIRED: R-10 APPROVED PLANS MUST BE ON JOB SITE PROPOSED: 0.30 PROPOSED: 0.50 PROPOSED: 0.30 PROPOSED: R-49 PROPOSED: R-38 PROPOSED: R-21 PROPOSED: R-21 PROPOSED: R-10 PROPOSED: R-30 PROPOSED: R-10 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 1/411 = II_OII IN EXISTING BUILDINGS, PER WSEC SECTION R503.1.1, EXCEPTION 2, ALL EXISTING FRAMING CAVITIES WHICH ARE EXPOSED DURING CONSTRUCTION SHALL BE FILLED TO THE FULL DEPTH WITH BATT INSULATION OR INSULATION HAVING AN EQUIVALENT NOMINAL R-VALUE. 2x4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OR R-15 AND 2x6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OR R-21. ROOF/ CEILING ASSEMBLIES SHALL MAINTAIN THE REQUIRED SPACE FOR VENTILATION. WSEC R401.3 INSULATION CERTIFICATE THE DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST A "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN T OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. WSEC R403.1.1 PROVIDE A PROGRAMMABLE THERMOSTAT FOR THE PRIMARY SPACE CONDITIONING SYSTEM WITHIN EACH DWELLING UNIT. City Of Edmonds Building Department Work r BATHROOM REMODEL Address 9122 242ND PL SW Owner �------------------------------MINEAR Approved Date 6/25/2021 ------------------------- Building Official W. W c4kc z Permit Number BLD2021-0785 WSEC R404.1 A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. FANS SHALL VENT DIRECTLY TO EXTERIOR OF THE BUILDING. FANS TO OPERATE CONTINUOUS. VAPOR RETARDERS SHALL BE INSTALLED AS SPECIFIED IN WSEC R502.1. EXTERIOR JOINTS SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED. OUTDOOR AIR INLET/S TO BE PROVIDED BY USING EXHAUST FANS PER IRC M1507.3.4.4. PER SEC M1507.3.4.4, OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH (12.7MM) ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. PER WSEC TABLE R402.1.1 - WINDOW & DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION. STROBL DESIGN LLC 3923 N 31 ST ST TACOMA, WA 98407 PHONE: (206) 661-3622 12358 REGISTERED TATE OF WASHINGTON LU 0 z I LU D n LU d) OL < (1 Q K N II I � LU N Z� N � REVISIONS BY RECEIVED Jun 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Date 6/8/2021 Scale 1/4" = 1'-0" Drawn JS Job Sheet