APPROVED BLD ENG BLD2020-0992+Architectural_Plan+10.12.2020_9.54.42_AM1 Z 41-0, o W a �Ji.p E b�l -- _ LDm G � � �C� � v � LO�'7iS" �tGY✓ _-I—F\ok/ L2 �� FL may- �. OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. SITE PLAN SCALE 1" = 50 FT OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE l0l5a0a- EY ''II E � T4v tie, E r + NORTH Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. r p � ;Special Inspection report required for soils. Please provide this ;document to the Building Inspector. See sheet 3 of 4 for :additional information. ----------------------------------------------------------------------------------- Zone ---- Corner ;_____ :Flag Setbacks: Required Actual ---------- ----- Front '---------- '-------- Sides .---------- Rear Other Height QRO.IEGT VATA ai�ai�mn 51TE ADDRESS: -1-125 - 165"' PLACE S.W. EDMOND5 WA g5026 OWNER NAME: ROB WILLIAM5 CURRENT ADDRESS: SAME A5 ABOVE TELEPHONE- 425-87q-5234 ASSESSOR'S PARCEL No. 00752000000400 ZONIN6: R5 12 LEGAL DESC: LOT 4, HAINE5 POINT, NE 1/4 5EG 7 TWP 21N RSE 4E, AM CITY OF EDMOND5 COUNTY: 5NCHOM15H JURISDICTION: CITY OF EDMOND5 GON5TRUCTION TYPE: V - B OCCUPANCY: R3 / U (6ARAGE/CARPORT) PROJECT DESCRIPTION: NEW DECK AT SECOND FLOOR WITH A NEW DOOR AND WINDOYV PROJECT AREA SO FT HEIGHT LIMIT LIVING 5LACE NEW EXISTING TOTAL NO CHANGE TO EXISTING FIRST FL 267.5 267.5 SECOND FL 1537 1537 LTV. 5P. TOTAL 4215 4215 GARAGE 952 q52 DECK 138 155 COV PORCH 72 72 MISC. TOTAL 135 1024 1162 LOT COVERAGE SO FT 1RO AN37 WSEC 2015 LOT AREA 25,g04 HEAT SYSTEM: EX. SA5 FORGED AIR MAX PERCENT COVERAGE 35% CLIMATE ZONE MARINE AREA 4 MAX COVERAGE AREA q,066 VERTICAL &L. 0.30 MAX GL % N/A PROP05ED GOVI=RA0E 5,540 OVERHEAD 6L 0.50 HEADER R--10 PROPOSED PERCENTA6E 14.52% CEILING R-4q VAULT R-55 LOT GALL NEW EXI5TIN6 TOTAL WALL (INT) R-21 BELOYLE 6R, R-21 HOU5E 2615 2675 FLOOR R-30 SLAB EDGE R-10 GARAGE q52 q52 ENERGY CREDITS DECK 155 135 ENERGY CREDITS REOUIRED NONE GOY PORCH 72 I 72 CREDIT METHOD N/A NO OHAN6E TO IMPERVIOUS SURFACE - NEW DECK 15 OVER EXISTING PATIO OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES City of Edmonds Building Department APPROVED Plans City Of Edmonds Building Department Work DECK WINDOW DOOR ------------------------------------------------ --------------------------------------------- Address 7725 168TH DT SW --------------------------------------------------------------- ------------------------ ----------------------- Owner WILLIAMS ------------------ --------------- Approved Date 10/14/2020 --------------------------- Building Official: Do7eArzqm#L ; W. X v�% Permit Number --------------- B L D2020-0992------- ------------------------ ENGINEERING DIVISION APPROVED AS NOTED C✓ "�`� 10/14/2020 RESUB Oct 12 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 z 0 WU LU �~y r = Dx L)z Ld¢ �LL LU O mW rn y .t1 ry lu K 7- Q JU z Q g lsi w lu � v J _ r I Ln iV r r 2+, Z3 REVISIONS 2. 3. 4. 5. VESIGN LOAFS CODES 2015 IRC, INTERNATIONAL RESIDENTIAL CODE, 261.5, ENERGY COVE ANP V.I.At.0. CODE NITH WASHINGTON 5TATE AMENPMENTS LIVE LOAD5 • ROOF: 25 PSF (SNOW) • FLOOR-15- 40 PSF • SLEEPING ROOMS AND HABITABLE ATTICS: 30 P5F • ATTIC WITH LIGHT STORAGE: 20 P5F • ATTIC, WITHOUT STORAGE: 10 P5F • STAIRS: THE GREATER OF 40 PSF OR CONCENTRATED LOAD OF 300 LB5 PER 4 56ZUARE INCHES • DEGK5 AND BALCONIE5:160 P5F • GUARD AND HANDRAILS: HORIZ 2004k PT. LOAD AT TOP • GUARDRAIL IN -FILL COMPONENTS: 50 LB5 PER SO FT • BASIG WIND SPEED: 85 MPH, EXPOSURE B (U.N.O.) • SEISMIC ZONE: USE GROUP 1, DESIGN CATE60RY 02 SOIL • SOIL BEARING CAPACITY ASSUMED AT 1500 PSF IN PLANS OR PER REPORT BY QUALIFIED SOILS ENGINEER. • EARTH PRESSURE ASSUMED AT 60 PGF EQUIVALENT FLUID PRESSURE FOR BASEMENT WALLS AND 30 PGF FOR CANTILEVER RETAINING WALLS. CONCRETE • 3000 PS! MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, WHERE PLACEMENT 15 EXPOSED TO WEATHER, GARAGE AND CARPORT SLABS, PORCHES, STEPS AND RETAINING WALLS (TABLE R402.2.). • 2500 P5[ MINIMUM AT OTHER CONCRETE, NOT EXPO5FD TO WEATHER. • EXTERIOR WALKS AND 5LA135 TO BE AIR ENTRAINED NOT LE55 THAN 5% OR MORE THAN -T%. • MIX REQUIREMENTS: 5-1/2 SACK CEMENT PER CU YO, WITH MAXIMUM OF 6 GAL. WATER PER BACK. MAXIMUM SLUMP 4", MAXIMUM AGGREGATE SIZE 1-1/2" REINFORCING STEEL • ASTM A-615 GRADE 40 FRAMING LUMBER (UNLESS NOTED OTHERWISE) PLATES HF #2 (P.T. AT GONG) MUD51LL5 ON GONG P.T. HF #2 STUDS HF "STUD GRADE" JOISTS AND RAFTERS HF #2 POSTS AND HEADERS OF #2 BEAMS OF #2 GLU-LAM BEAMS (SIMPLE SPAN) 24F--V4 GLU-LAM SEAM5(OVERHANGING) 24F-V8 DECK J015T5 P.T. OF #2 DECK BEAMS P.T. OF #1 MASONRY • MORTAR: TYPE 5, 1 PG, 1/2 LIME PUTTY, 4 SAND. GRADE 40 STEEL GENERAL NOTES CONTRACTOR SHALL VERIFY ALL EXISTING 51TE CONDITIONS FOR COMPLIANCE WITH PLANS AND SPECIFICATIONS. SITE CONDITIONS INGLUDE, SOIL, TOPOGRAPHY, REQUIRED SETBACKS AND IF APPLICABLE, THE DIMENSIONS OF EXISTING STRUCTURES AND THEIR STRUCTURAL AND MECHANICAL COMPONENTS. THIS OFFICE SHALL BE NOTIFIED PRIOR TO CONSTRUCTION OF DISCREPANCIES, AMBIGUITIES OR OMISSIONS IN THE PLANS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER DRAWING SCALE. DETAILS TAKE PREGEDENGE OVER PLAN AND ELEVATION VIEWS. ALL WORKMANSHIP, MATERIALS AND INSTALLED PRODUCTS SHALL MEET OR EXCEED THE AGGEPTED INDU5TRY STANDARDS AND SHALL MEET OR EXCEED THE MINIMUM REQUIREMENTS OF THE CURRENT CODE IN FORGE AND ALL APPLICABLE LOCAL CODES, WHICH TAKE PRECEDENCE OVER NOTES,.. SPECIFICATIONS AND.DRAININGS. UNLE55 A PROFESSIONAL SURVEY ACCOMPANIES THE PLANS, THE PLOT PLAN WAS DRA INN FROM GENERAL 51TE LANOMARK5 AND 15 NOT TO BE CONSTRUED AS A PROFE55IONAL SURVEY. THE CONTRACTOR SHALL TAKE FULL RESPONSIBILITY FOR MAINTAINING REQUIRED ZONING SETBACKS OR SHALL, AT HIS DISCRETION, REQUEST THE OWNER TO PROVIDE A PROFESSIONAL SURVEY TO DETERMINE SETBACKS AND/OR OTHER ZONING RESTRICTIONS. THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS AND INSPECTIONS AND SHALL NOTIFY THIS OFFICE, PRIOR TO CONSTRUCTION, OF ANY REV15IONS OR ADDED REQUIREMENT5 EEQUE5TED BY THE BUILDING OFFICIAL HAVING JURI5DIGTION. THE CONTRACTOR SHALL VERIFY 51ZE AND LOCATION OF ALL REQUIRED OPFNINC75 IN FLOORS, WALLS AND ROOF WITH PROPOSED MECHANICAL, PLUMBING AND ELECTRICAL WORK. PREFABRICATED ITEMS TO BE HANDLED AND INSTALLED PER MANUFAGTURER'5 RECOMMENDATIONS. THESE DRAkNIN65 ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. PROTECTED UNDER COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT, REPRODUGTION OR USE OF THESE SERVICE DOCUMENTS BEYOND THE SCOPE OF TH15 PROJECT 15 PROHIBITED WITHOUT PERMISSION IN WRITING FROM THE ARCHITECT. SEVERAL GONSTRUGTION NOTES A. 51TE CONDITIONS AND SITE WORK ud G. VENTILATION AND ACCE55 ❑ O. TRUSSES 1. EX IF 501E CONDITIONS ENCOUNTERED UPON EXCAVATION DIFFER 1. VENTILATE CRAWL SPACES AND OVERHANGING FLOOF- WITH 1. PRE-FAE391CATED TRU551=5 SHALL BE DE51ONF-D BY A FROM THE 501E BEARING CAPACITY OUTLINED UNDER "DIFFER SCREENED OPENIN65 NOT LE55 THAN 1 SO. FT. NET CZAR WA5HINGTON STATE LICENSED STRUCTURAL ENGINEER AND IN LOADS", OR IF BEARI EXCESSIVE GROUND WATER 15 PRESENT, 9 If AREA FOR EACH 300 50. FT. OF UNDER FLOOR ARE . ACCORDANCE WITH THE PLAN REQUIREMENT5. SUBMIT CONTACT OFFICE BEFORE PROCEEDING. DISTRIBUTE OPF-NIN65 APPROXIMATELY EQUAL ALONG €HE COMPLETE SHOP DRAWINGS WITH ENGINEER'S SEAL FOR ALL FOOTINGS SHALL EXTEND TO BELOW THE FROST LINE AND EXTEND LENGTH OF AT LEAST TWO OPPOSITE SIDES AND ONE OPENING APPROVAL PRIOR TO FABRICATION. TRUSSES MUST BE SHALL BEAR ON UNDISTURBED, NATIVE SOIL. V41THIN 3 FT OF EVERY CORNER. 5TAMPE_.D BY AN APPROVED MANUFACTURER OR BY A QUALITY 2. DO NOT BACKFILL UNTIL WALL5 HAVE BEEN ADEQUATELY COVER WITH 1/4" CORROSION -RESISTANT WIRE MESH AT CONTROL AGENCY SUCH A5 WA5HIN6TON WOOD TRU55 D OR HAVE BEEN DESIGNED TO RESIST LATERAL EARTH BRACEDBEILL CRAWL SPACE OPENIN65. FABRICATORS COUNCIL. RE. BAG MATERIAL SHALL BE GLEAN, PERMEABLE PRESSW 2. PROVIDE" 15" X 24" MIN. CLEAR ACCESS THRU FLOOR GsR' 16" X 2. CONTRACTOR TO VERIFY SPANS PRIOR TO FABRICATION. AND FREE OF ORGANIC MATERIALS. 24" THROUGH ALL TO UNDER FLOOR AREAS. 3 . APPROVED HANGERS MUST BE USED AT ALL CONNECTIONS OF 3. INSTALL A 4 INCH DIAMETER PERFORATED PERIMETER DRAINS AFT. S. 3ENTILATE V ATTIC SPACES WITH NET CLEAR AREA EQUrL TO RAFTERS, JACKS, OR HIP TRUSSES TO A MAIN GIRDER TRUSS. IN ONE OF DRAIN GRAVEL PER LINEAL FT. WITH FILTER 1/150TH OF THE ATTIC AREA, EXCEPT THE NET AREA MAY BE NON -BEARING PARTITIONS BELOW TRUSSES SHALL BE FABRIC OVER. PROVIDE SEPARATE DOWNSPOUT AND SEALED D 1/300TH, PROVIDED 50% -. 15 36" ABOVE EAVES, WITH SEPARATED FROM TRU55 WITH 51MP5ON 5TC GLIP5. SURFA CE DRAINAGE AND/OR TE ON SYSTEM A5 REQUIRED 5U FAGAL THE BALANCE IN THE ErAVE5. 4. TRU55E5 SHALL BE BRACED TO PREVENT ROTATION AND GORE. 5. WHEN A 30" OR MORE CLEAR ATTIC HEIGHT EXISTS FF'OM THE PROVIDE LATERAL 5TABILITY AND INSTALLED IN ACCORDANCE TOP OF CEILING JOISTS TO UNDERSIDE OF ROOF AND .=S 30+ WITH THE INDIVIDUAL TRUSS DESIGN PROVIDED BY THE �( VL.! B. CONCRETE 5Q FT AREA, PROVIDE AN AGG1;5515LE PANEL 22" X 5O`, WITH MANUFACTURER. 90" CLEAR HEIGHT ABOVE. PROVIDE INSULATION RETrjNER, R- 1. CENTER ALL P05T FOOTINGS UNLESS NOTED AND PROVIDE 2 qq BATT AND WEATHER-STRIP. ❑ P. 5KYLIGHT5 INCH PLINTHS ADJACENT SLABS, S INCH PLINTHS AT OPEN EARTH (6 INCH IF POST 15 PRESSURE TREATED), AND INSTALL H. SAFETY GLASZING 1. GLAZING SHALL BE INSULATED, FULLY TEMPERED (TOP), SILL PLATES AT LEAST 6 INCHES ABOVE FINISHED GRADE OR 2 LAMINATED GLASS WITH MIN. 0.015" POLYVINYL BUTYRAL INCHES ABOVE SLABS. DAMP-PROOF EXTERIOR OF BASEMENT 1. TEMPERED SAFETY GLASS SHALL BE INSTALLED IN INNER LAYER (BOTTOM). WALLS AND WALLS RETAINING EARTH ADJACENT HAZARDOUS LOCATIONS AND SUBJECT TO HUMAN IMP�.GT, 2. PROVIDE A MINIMUM 4" CURB, FLASHED AND COUNTER 6RAWL5PAGE5 WITH TWO COATS OF ASPHALTIC, EMULSION GLAZING IN DOORS, GLAZING WITHIN A 24" ARC, OF GLr'SED FLASHED AT TOP AND BOTTOM AND STEP -FLASH SIDES. UNLESS A 5PEGIFIG WATERPROOFING SYSTEM 15 SPECIFIED IN DOOR, GLAZED AREAS > q SO. FT. WHEN LESS THAN 16" THE UNIT SHALL HAVE A CONDENSATION GUTTER AT THE THE PLANS. ABOVE A WALKING SURFACE, PER IBC/IRE R308.4. LOWER END. INSTALL PER MANUFACTURER'S INSTRUCTIONS, 2. INSTALL STEEL REINFORCING PER A.G.I. STANDARD PRACTICE. 2. SAFETY GLAZING 15 REQUIRED TO BE PERMANENTLY FINISH AND FLARE WELL TO CEILING PER PLANS. SPLICE CORNER AND CONTINUOUS BARS WITH A MIN. OF 30 MARKED PER IBCARG R308.1. BAR DIAMETERS. MINIMUM BAR CONCRETE COVER 15 5" TO ❑ Q. EMERGENCY EGRESS EARTH, 2" TO WEATHER, 1" TO OTHER. Ld I. ELECTRICAL 5, ANCHOR BOLTS TO BE E=MBEDE.D A MINIMUM OF `7 INCHES 1. ELECTRICAL CONTRACTOR SHALL EVALUATE AND DE 1. EVERY SLEEPING ROOM, BASEMENT, AND HABITABLE ATTIC U.N.O., TWO BOLTS MIN. PER PLATE, PLACE WITHIN 12" FROM ADEQUACY OF EXISTING AND PROPOSED ELECTRICALL SERVIERVICE SHALL HAVE'ONE OPERABLE EMERGENCY ESCAPE AND RESCUE ENDS BUT NOT LE55 THAN -7 DIAMETERS TO END. AND PROVIDE REQUIRED CIRCUITS AND AMPERAGE.PER N.E.G., OPENING. THE OPENING SHALL HAVE A MAXIMUM 511-L HEIGHT 4, NEIN FOOTIN65 SHALL EXTEND TO A DEPTH THAT WILL NOT STATE AND LOCAL ENERGY GORES, AND MANUFACTURER'S OF 44" ABOVE THE FLOOR, A NET CLEAR OPENING OF 5.1 5Q. IMP05E LOADS ON NEW OR EXISTING BASEMENT OR RETAINING SPEGIFIGATION5 FOR PROPOSED PRODUCTS, APPLIAh':��5 AND FT., MIN. CLEAR HEIGHT OF 24", MIN, CLEAR WIDTH OF 20" AND WALLS UNLE55 SPECIFICALLY DETAILED IN THE PLANS. EQUIPMENT. SHALL BE OPERABLE FROM THE INSIDE WITHOUT SPECIAL 5. TIE NEW FOOTINGS TO EXISTING FOOTINGS AT ALL TOOLS OR KEYS. GRADE FLOOR OPENINGS MAY HAVE NET INTERSECTIONS WITH A MINIMUM OF TWO #4 PINS AT FOOTING CLEAR MIN. OPENING OF 5 SO. FT. W AND TO #4 PINS AT WES ALL. EMBED PINS 4 INCHMINIMUM IN [ J. MEGHA�NIGArL EPDXY GROUT. 1. WARM AIR FURNACE OR GAS H.W. TANKS SHALL NOT BE ❑ R. SMOKE ALARM5/DETECTOR5 ,AND INSTALLED UNDER STAIRS AND 5HALL HAVE PROPER VENTS CARBON MONOXIDE ALARM5/DETECTOR5 uf G. LUMBER AND DIRECT OUT51DE COMBUSTION AIR PER CODE, AND MANUFA6TURER'5 SPECIFICATIONS. 1. SMOKE DETECTORS SHALL BE LOCATED IN EACH SLEEPING 1. FRAMING LUMBER TO BE KILN DRIED TO 1q% MOISTURE 2• GAS APPLIANCES IN GARAGE SHALL BE ON A 18" HIGH AREA AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA CONTENT, GRADED PER STD. GRADING RULES PER PLATFORM. IF APPLIANCE 15 IN LINE OF VEHICLE TRAFFIC, GIVING ACCESS TO EACH SLEEPING AREA. WHERE AN ACCESS I^I.G.L.I.B. OR W.W.P.A. AS APPLICABLE. PROVDE GRADE PROVIDE A 3" (P GONG FILLED STEEL BOLLARD. CORRIDOR OPENS INTO A ROOM WITH A CEILING q0" OR AND SPECIES AS PER FRAMING PLANS, GENERAL NOTES, 3. AIR DUCTS PENETRATING GAR 6E TO HOUSE SEPARATON HIGHER THAN THE CORRIDOR, OR HAS A DOOR, A DETECTOR AND DE516N LOAD CHART, 5HALL BE 26 GAUGE MIN. OR HAVE APPROVED DAMP1T5. SHALL BE PLACED IN EACH. DWELLING5 WITH MORE THAN ONE 2. SILL PLATES, DECK SUB-5TRUGTURE5, POSTS AND BEAMS 4. DUCTING TO MEET MECHANICAL 57D5 AND SYSTEMS ARE TO BE STORY OR WITH A BASEMENT SHALL HAVE A DETECTOR EXPOSED TO WEATHER AND WOOD IN CONTACT W1TH BALANCED. CONTRACTOR SHALL PROVIDE MEGHANIGGL INSTALLED AT EACH LEVEL AND IN OL05E PROXIMITY TO THE CONCRETE SHALL BE PRESSURE TREATED WITH AN DUCTING, EQUIPMENT 51ZING, HEAT L055 GALCULATIONe AND STAIRS. ALL SMOKE; DETECTORS SHALL BE INTERCONNECTED APPROVEDPRESERVATIVE. APPROVED PRESERVATIVE. MANUFACTURER'5 DATA ON EQUIPMENT EFFICIENCY FOR AND AUDIBLE IN EVERY BEDROOM WITH THEIR DOORS CLOSED. 3. BEAMS SHALL AN A.I.T.G. INSPECTION STAMP OLU -LAMBUILDING DEPARTMENT REVIEW. 2. SMOKE DETECTORS IN NEW CONSTRUCTION SHALL BE DIRECT D. FRAMING 5. BATHROOMS, LAUNDRY ROOMS, KITCHENS AND SPA ROOMS WIRED TO BUILDING POWER WITHOUT A DISCONNECT 51/4ITCH SHALL HAVE MECHANICAL EXHAUST, IN INSULATED, RIGID OTHER THAN FOR OVERGURRENT PROTECTION AND MUST HAVE 1. COLUMNS AND POSTS SHALL BE FRAMED TO TRUE END DUGTING TO EXTERIOR, WITH A BAGKDRAFT DAMPER, CAPABLE BATTERY BACK-UP. BEARIN65 WITH ADEQUATE ANCHORS AT TOP AND BOTTOM TO OF 5 AIR CHANGES PER HOUR. 2. REMODELED OR ALTERED EXISTING BUILDIN65 MAY HAVE PREVENT UPLIFT AND DISPLACEMENT. 6. DRYER 'EQUIVALENT' EXHAUST DUCT LENGTH 15 TO BE POSTED BATTERY ONLY OPERATED DETECTORS WHERE DIRECT WIRING 2. PROVIDE LATERAL SUPPORT FOR BEAMS, RAFTERS, AND WITHIN 6 FT OF DUCT CONNECTION. REQUIRE5 THE REMOVAL OF EX151TNG INTERIOR FINISHES. JOISTS PER IRG R502-A AND PROVIDE TEMPORARY BRACING -7. RAN6EHOODS IN EXCESS OF 400 GFM SHALL HAVE AUTO- 5. CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE A5 REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND CONTROLLED OUTSIDE MAKE-UP AIR. AND IN THE IMMEDIATE VICINITY OF SLEEPING APEF S,A-I!D ot\ j �'L`ovel`, STIFFENERS ARE; INSTALLED. ❑ 3. PROVIDE A MINIMUM JOIST BEARING OF 1-1/2" ON WOOD, 3" ON ❑ K. PLUMBING 5. SECURITY CONCRETE, WOOD ENTERING CONGRETE OR MASONRY SHALL 1 PLUMBING CONTRACTOR 5HALL 51ZE ALL LINES. VENTS, 1. PROVIDE SECURITY AT ENTRANCE AND GARAGE DOORS WITH A HAVE 1/2" NET AIRSPACE AT TOP, SIDES AND END. AIRGAPS, AND CLEAN -OUTS PER COPE- MINIMUM 1/2" THROW DEAD BOLT WITH LOCKS OPERABLE 4. MULTI 2X BUILT-UP BEAMS SHALL BE SPIKED TOGETHER. 2 ITH A1-46 SECTION 402.0 FLOW RATES TO COMPLY WWG 9 V41THOUT SPECIAL. KNOWLEDGE, KEYS OR EFFORT. UNLESS NOTED, USE 10d NAIL5 AT 12 O.G. STAGGERED. TOILETS. 1.6 OFF (MAX), SHOWERS: 2.5 GPM (MAX), 2. PROVIDE AN OBSERVATION PORT ® 54"-66" ABOVE THE 5. 50LID BLOCK W/ 2X AT MIDPOINT OF STUD5 OVER 10 FEET, LAVATORIE5/FAUCET: 2.5 GPM (MAX). FLOOR AT SOLID, UNGLAZED ENTRY DOORS, BELOW BEARING PARTITIONS PERPENDICULAR TO JOISTS AND 5, HOT WATER TANKS SHALL BE SIZED BY INDUSTRY STPS RAFTERS AT SUPPORTS. DOUBLE JOISTS UNDER PARALLEL FOR PROPOSED USE AND BE LABELED NAEGA APPRC'1EV. ❑ T. G,AR,AGE /DWELLING SEPARATION BEARING PARTITIONS AND UNDER WINDOW CRIPPLES AT 4. HOT WATER TANKS REQUIRE DUAL (HIGH AND LOW) 5E5yIIG OVERHANGING FLOORS. STRAPS SECURED TO STUDS, EXPANSION TANK, AND A; 1. GARAGE TO DWELLING SEPARATION SHALL CONSIST OF 6. FIRE5TOP AND DRAFTSTOP TO CUT OFF ALL CONCEALED PRE55URE RELIEF VALVE (PLUMBED TO EXTERIOR). FIRETAPEJ 1/2" GNIB, APPLIED TO THE GARAGE 51DE OF ALL HORIZONTAL AND VERTICAL OPENIN65 AT CEILINGS, FLOORS, GARAGE" SURFACES ADJOINING DWELLING'S LIVING, ATTIC AND AND ATTIC. PROVIDE VERTICAL FIRESTOP5 AT 10' HORIZONTAL GRAINL SPACES. INTERVALS AT WALL FURRING VOIDS, ❑ L. MOISTURE CONTROL 2. DOOR5 FROM GARAGE TO DWELLING SHALL BE 1-3/8"+ THICK, FIRESTOP TOP, BOTTOM AND SIDES OF STAIRS WITH 2x 1 ERS SHALL HAVE A NON-A5ORBENT SURFACE TO A 5HOWB SOLID GORE, AND TIGHT FITTING. NOMINAL LUMBER. HEIGHT OF '72 INCHES ABOVE FLOOR. 3. GARAGE CEILIN05 COMPOSED OF 2X+ SOLID -SAWN JOI5T5 AND Ed E. METAL CONNECTOR5 2. PROVIDE WATERPROOF BOARD OR SLA55 MESH MORTAR 5UPPORTIN6 HABITABLE SPACE; ABOVE, SHALL HAVE ONE "X" UNITS BEHIND TIES AT SHOWER SURROUNDS. TILE 5HCYiER5 LAYER OF FIRETAPED 5/8" TYPE GWB. ALL GARAGE POSTS, 1. ALL METAL CONNECTORS SHALL BE "51MP50N" OR AN W1TH A 51TE-BUILT PAN SHALL BE FILLED AND LEAK TESTED BEAMS, AND WALL5 5UPPORTIN6 HABITABLE SPACE SHALL APPROVED EQUIVALENT, FOR 12 HOURS. PROVIDE MILDEW RF-515TANT CAULK AT ALL HAVE ONE LAYER OF FIRETAPED 1/2" GWB. GARAGE CEILINGS 2. FRAME NAILING SHALL COMPLY WITH IBCARG R602,3,0) (2) TILE ACCESSORIES. COMPOSED OF 1-JOIST5, WITH HABITABLE SPACE ABOVE, SHALL UNLESS NOTED OTHERWISE ON FRAMING PLANS OR HAVE TWO LAYERS OF FFRETAPED 1/21, TYPE "X", GWB MIN. 5HEARWAL.L 5GHEDULE, ALL NAILS SHALL BE COMMON WIRE ❑ M. BATH SAFETY 4. AIR DUCTS PENETRATING THE SEPARATION SHALL BE 26 GAUGE NAILS U.N.O. MINIMUM OR HAVE AN APPROVED DAMPER. 3. USE GUT WASHERS AT BOLTED CONNECTIONS. 1. HINGED SHOWER DOORS SHALL OPEN OUTWARD. 0006-5 ANCHOR BOLT WASHERS TO BE SQUARE 3" x 3" x 1/4". AND SHOWER ENCLOSURES SHALL BE FULLY TEMPERED OR U. STA IR5 ^NV GUA KPRNL5 CONNECTORS EXPOSED TO ENEATHER SHALL BE GALVANIZED LAMINATED SAFETY GLASS, MINIMUM THICKNESS = 1/8" 1. STAIRWAYS SHALL HAVE A MIN. WIDTH OF 36", A RISER HEIGHT OR HAVE APPROVED COATING, ROOFING SHALL BE FASTENED TEMPERED, 1/4" LAMINATED. OF -7-3/4" MAX., A MIN. TREAD LENGTH OF 10", AND 5/5" WITH CORROSION -RESISTANT FASTENERS. 2. FLOOR TILES AT SHOWERS AND WET AREAS 5HAL1- BE MAXIMUM VARIATIONS. A TREAD NOSING OF 5/4" TO 1-1/4" 15 4. ACQ-C and D TREATED WOOD (ALKALINE COPPER G2UAT) SKID -RESISTANT. PROVIDE SECURE BLOCKING FOR r s REQUIRES CORROSION PROTECTED FASTENERS, BOLTS, AND GRAB BARS PER PLAN, CAPABLE OF SUPPORTING A 500 REQUIRED ON 5TAIRWAYS WITH SOLID RISERS UNLE55 TREAD HARDWARE SUCH A5 SIMPSON "ZMAX" OR HDE (HOT DIPPED LB. IMPACT LOAD. DEPTH 15 11" OR GREATER. GALVANIZED) OR 5ST300 (STAINLESS STEEL). 2. HANDRAILS SHALL- BE PROVIDED ON AT LEAST ONE SIDE OF ❑ N. FA OTORY BUILT FIREPLACES / 5TOVE5 FLI6HT5 WITH 4 OR MORE RISERS. ❑ F. PLYWOOD AND DIA f=HRA&m NAILING 3. HANDRAILS SHALL BE PLACED 34" TO 38" ABOVE THE N05ENG5 1. UNITS 5HAL1- BE U.L. LISTED PER UL12-1, AND INSTALLED PER AND 5PACED 1-1/2" MIN. OFF WALL WITH A 1-1/2" TO 2" 1, ALL STRUCTURAL PLYWOOD SHALL HAVE A GRADING MANUFAGTURER'5 RECOMMENDATIONS AND REQUIRED DIAMETER, SMOOTH 6RA5P AND AT NEWEL OR 1-1/4" RETURN STAMP OF APA AND NAIL PER IBG/IRG 602.3.(1),(2). CLEARANCES. AT ENDS. 2, PROVIDE DIAPHRAGM SHEATHING AND NAILING: (U.N.O.) 2. UNITS SHALL HAVE TIGHT -FITTING GLASS OR METAL 00OF-5, 4. PROVIDE 80" MIN. CLEAR HEADROOM ABO FLOOR SHEATHING SHALL BE 3/4" T86 C-D-EXT-APA READILY ACCESSIBLE CONTROLS TO A TIGHT FITTING FLUE 5, AREAS 90" ABOVE GRADE (WITHIN 3 FT) 099OOR5 PLYWOOD WITH EXT GLUE, PI: 52/16, GLUE AND NAIL DAMPER, 6 INCH DIAMETER OUTSIDE COMBUSTION AIR DUCT TO PROVIDE GUARDRAILS WITH A MINIMUM HEIG-T O,(F j' 0 10d AT 6" O.G. EDGES, 10" O.G. FIELD. FIRE BOX, AND A 3/8 INCH THICK MIN. NON-COMBUSTIBLE _ IL INTERMEDIATE BALUSTERS OR RAILS SPAG c l-¢ ROOF SHEATHINE SHALL BE 15/52" C-D-INT-APA PLYWOOD -7/16" HEARTH EXTEN51ON THAT 15 READILY DISTINGUISHABLE FROM SPHERE CANNOT PASS THROUGH. CITY of EDMONDS USABLE SPACE UNDER 5TAIP-5 f]��(�LfJQMAw ICES WITH EXTERIOR GLUE, PI: 24/0, OR 055. 5URROUNDINE FLOOR. 6. ENCLOSED pPROVIDE NAIL Sd AT 6" O.G. PANEL EDGES, 12" O.G. FIELD. 5. PROVIDE CHIMNEY SIZE AND CLEARANCES PER CODE AND FIRETAPED 1/2 EWB, ON WALLS AND 5OF�FII"1Tf5. WALL SHEATHING SHALL BE 15/32" C-D-INT-APA PLYWOOD MANUF. SPECS FOR INSTALLATION OF 50LID FUEL BURNING FIREBLOGKING IN CONGEALED SPACES BETWEEN STAIR WITH EXTERIOR GLUE, F 1, 24/0, OR -7/16" OSB. APPLIANCES. STRINGERS AT TOP AND BOTTOM OF RUN AND BETWEEN STUDS NAIL 8d AT 6" O.G. PANEL EDGES, 12" O.G. FIELD. 4. FIREPLACES WITH GAS COMBUSTION ONLY SHALL BE ALONG AND IN LINE WITH RUN OF STAIRS. INSTALLED PER I.M.G. AND MANUF. SPECIFICATIONS. 'o Lu iL n V z 7-1 JU Q U p W o� � Z z O O � m d Q m , Z.4•z-o REVISIONS 2 ,.42-I, li 0 1 E?( U V, v I�I JIJ1" /)MAtJ JFt 0+FIr u4f_ � Vlop cqh� J it l � j �j[ t---------------------, SE�ONi/ FLOOR PLAN � Hardware and fasteners in contact with ■ preservative -treated wood shall be of hot -dipped zinc galvanized steel, ■ 5GALE 1/4" = V- O" stainless steel, silicon bronze or copper. I -. In the absence of manufacturer's ■ recommendations a minimum of ASTM A 653 ��pE � I{ type G185 zinc -coated galvanized steel, or L equivalent, shall be used. I Ex bole-0 - Tr/ eX bitJ ItJG CGS-s° FIRST FLOOR PLAN 1 W- [91, H6M E 001_191IE7� 2X lb m rb!�� IPV_41 141 SECoONP FLOOR FRAMING PLAN IRC R317.3.1 IBC 2304.10.5.1 L _-_-_-_-_-_-_-_-_-_.J IBC III L �JSaoJe . 0') l REFERENCE Ph -I NORTH CMS W-�� fiW Erl 511 o +HIS SCALE 1/4" = 1'- O" ATTENTION: SPECIAL INSPECTION REQUIRED Soil condition to be evaluated by Geo-Tech inspection, Robert M Pride, P.E. prior to placing concrete and to be documented as conforming to the requirements before proceeding. nl - FOUNPATION PLAN 5GALX 1/4" = 1'- O" ANI;� O^ ANV EXTERIOR 170OR SGHEaULF. ATTENTION: TH15 SCHEDULE 15 FOR ENERGY CODE GLAZING COMPLIANCE ONLY, AND 15 NOT INTENDED A5 PRODUCT OR;JERING 5PECIFICATIONS. • SEE WORD ABBREVIATION INDEX ON PAGE 1 - PROVIDE HARDWARE B AGCESSORIE5 PER OMER. • CODE LETTER = WINDOWS, CODE NUMBER = DOORS • PROVIDE WEATHER-STRIPPING FOR EXTERIOR DOORS. + ONLY THERMAL DOORS ARE L15TED BELOW. • PROVIDE 5GREENS FOR VENTING WINDOW5, DOOR5 AND 5KYLIGHT5. • VERIFY 51ZE5 AND QUANTITIES WITH PLANS. • PROVIDE MANUF. STD. MUNTIN GRILLS AS SHOWN ON ELEVATIONS. • SEE ELEVATIONS FOR VENTING & CU5TOM SHAPES. - MANUF/ SUPPLIER SHALL PROVIDE GONTRAGTOR WITH ROUGH • SEE FLOOR PLAN FOR ACTIVE DOOR PANELS & SWING. OPENING REQUIREMENTS AND INSTALLATION INSTRUCTIONS. NFRG GODS UNITSIZE NO. WIDTH HEIGHT 5Q. FT. DE5GRIPTION FRAME TYPE GLASS TYPE AIR51-. FEATURES U VAL U x A A 4/O x 5/O 1 4.00 5.00 20.00 SLIDER XO VINYL OR WOOD 2 GL LOW E ARG a500 T5G 1 5/0 x 6/5 1 3.00 6.611 21.00 STORE DOOR C FG OR 5TL IN5UL 2 GL LOW E ARG 0.500 TSC� CITY OF EDMONDS- GUANTITY TOTAL: 2 AREA = 4.1.00 5G. FT. TOTAL [ UA / AREA = UA AVERAGE =1 0.301UA TOTAAl DEPARTMEN J W p W LL Y O n=� •■ U O WIt p Z d p K N m v 5 E2 a f� { S LU W 0 0 Q 0 Z � Q 0 w ut0 OC a W p W VI w N o r Q N 4� U r Q Q I m S W cLI r W 0 0 z M U O p �o r z( <W 10 F zo N JU%Z JU U �W oLU � i*— O o tuQ 9, 2✓■Zo REVISIONS 1 Z .20 3 5GALE 1/4" = 1'- O" WINDOW: MILOARD, JELDWEN OR EGIJIV_ DOUBLE &LAZ=D WITH LOW E AND ARGON FILLED DOOR: 5lMP5ON, JELDWEN OR EQUIV. FIBERGLASS OR STEEL OVER RIGID INSUL. DOUBLE &LAZED LOW E ARGON El" of F,-)L s ^FST ELEVATION ZC-ALE 1/4" = 1'— 0" •—. - , I— I-- f - - • - �r Hem PP41 t . .I Hardware and fasteners in contact with ■ preservative -treated wood shall be of I hot -dipped zinc galvanized steel, ■ stainless steel, silicon bronze or copper. In the absence of manufacturer's recommendations a minimum of ASTM A 653 type G185 zinc -coated galvanized steel, or ■ equivalent, shall be used. I IRC R317.3.1 IBC 2304.10.5.1 ■ ., 1i 1i W�jl I �x 70 P a: z 0 W� sz 0U C~�-9 U S w Wti 0 mw co Q rn LO LO r LIv i kj/j K-00r.4 SOUTH ELEY,4TION I X 6-P1 A-P Hip rrz� (&*4 �5 101,W. SCALE 1/4" = 1'— 0" Nr6o< (.,0 �2I DETAIL r,-; r� r�Fb P6 r--, - �-H d*�Cg RESUB Oct 12 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W . 23.2 REVISIONS A. -)A,71, C! SGALE 1" = 1`-0" SCALE