APPROVED BLD-BLD2020-0840+Energy_Calculations+7.30.2020_12.25.19_PMRECEIVED BLD2020-0840 Aug 25 2020 Simple Heating System Size: Washington State CITY OFEDMONDS This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washin ton o e WSEC and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information 11x32 Addition above Garage Wartell 21423 95th PI. W Edmonds, WA 98020 Heating System Type: •AII Other systems o Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Design Difference (AT) 46 Edmonds = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 367 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 7.8 2,874 Glazing and Doors U-Factor X Area = UA Instructions 0.30 1 55 16.50 Skylights U-Factor X Area = UA Instructions 0.50 00 --- Insulation Attic U-Factor X Area = UA Instructions R_4y 0.026 367 9.54 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. V Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21Intermediate 0.056 438 24.53 Floors U-Factor X Area UA _ Instructions 0.025 367 9.18 Ras Below Grade Walls (See Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in this project. --- Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project. V Slab on Grade (see Figure 1) F-Factor X Length UA Instructions ;p Perimeter V 0.540 �n Location of Ducts Instructions Duct Leakage Coefficient Vnconditioned Space � 1.10 Sum of UA 59.75 Envelope Heat Load 2,748 Btu / Hour Figure 1. SumofuAXOT Air Leakage Heat Load 1,428 Btu / Hour Volume 0.6XATX.018 Building Design Heat Load 4,176 Btu /Hour �.e Air Leakage + Envelope Heat Loss Building and Duct Heat Load 4,593 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 6,431 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)