Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2020-0751+Manufacturer_Specifications_and_Installation_Instructions+7.21.2020_3.55.56_PM
CHARLOTTE PIPE AND FOUNDRY COMPANY® Date: 7/21 /2020 .lob Name: Graphite Arts I Engineer: Location: Edmonds Contractor: Silverdale Plumbing & Heating, Inc. Scope: This specification covers PVC Schedule 40 solid wall pipe and PVC DWV fittings used in sanitary drain, waste and vent (DWV), sewer and storm drainage applications. This system is intended for use in non -pressure applications where the operating temperature will not exceed 140' F. Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chrloride) vinyl compounds with a cell class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785 and ASTM D 2665. Injection molded PVC DWV fittings shall conform to ASTM D 2665. Fabricated PVC DWV fittings shall conform to ASTM F 1866. All pipe and fittings shall be manufactured in the United States. All systems shall utilize a separate waste and vent system. Pipe and fittings shall conform to NSF International Standard 14. Installation: Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall be installed in accordance with ASTM D 2321 and ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire -stopping materials, thread sealant, plasticized -vinyl products or other aggressive chemical agents not compatible with PVC compounds. The system shall be hydrostatically tested after installation. WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings. Doing so can result in explosive failures and cause severe injury or death. Referenced Standards: ASTM D 1784: Rigid Vinyl Compounds ASTM D 1785: PVC Plastic Pipe, Schedule 40 ASTM D 2665: PVC Drain, Waste and Vent Pipe and Fittings ASTM D 2564: Solvent Cements for PVC Pipe and Fittings ASTM D 2321: Underground Installation of Thermoplastic Pipe (non -pressure applications) ASTM F 656: Primers for PVC Pipe and Fittings ASTM F 1668: Procedures for Buried Plastic Pipe ASTM F 1866: Fabricated PVC DWV Fittings NSF Standard 14: Plastic Piping Components and Related Materials IE Coupling Quarter Bend Eighth Bend Double Sanitary Tee i Cleanout Tee Combination Wye P-Trap Closet Flange W/Plug & Eighth Bend Not all fitting patterns shown gIpDE Iry U54 PVC Schedule 40 DWV Pipe PVC Schedule 40 DWV Pipe NSF PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665 PART N0. NOM. SIZE UPC # 611942- QTY. PER SKID AVG. OD ON.) MIN. WALL ON.) WT. PER 100 FT. (LBS.) PVC 7100* 1'/4"x10' 03945 2120' 1.660 .140 42.4 PVC 7100* 11/4"0' 03946 4240' 1.660 .140 42.4 PVC 7112' 11/2"x10' 03947 1650' 1.900 .145 51.8 PVC 7112` 11/2"0' 03948 3300' 1.900 .145 51.8 PVC 7200` 211x10' 03949 990' 2.375 .154 1 69.5 PVC 7200' 2"x20' 03950 1980' 2.375 .154 69.5 PVC 7300' 31100' 03951 1040' 3.500 .216 144.2 PVC 7300` 311x20' 03952 920' 3.500 .216 144.2 PVC 7400t 4"xl0' 03953 600' 4.500 .237 205.5 PVC 7400t 4"x20' 03954 1200' 4.500 .237 205.5 PVC 7500t 5"0' 04837 760' 5.563 .258 272.5 PVC 7600t 6"x10' 03955 280' 6.625 .280 361.2 PVC 7600t 611x20' 03956 560' 6.625 .280 361.2 PVC 7800t 8"x10' 13087 180' 8.625 .322 543.6 PVC 7800t 8"0' 03958 360' 8.625 .322 543.6 PVC 7910t 10"0' 03959 220' I I10.750 .365 770.7 PVC 7912t 12'0' 03961 120' 12.750 .406 1019.0 PVC 7914t 14"0' 04862 60' 14.000 .437 1205.0 PVC 7916t 16"0' 1 04918 60' 16.000 .500 1575.7 *Du a I Marked ASTM D V85 &ASTM D 2665. tTriple Marked ASTM D 1785 &ASTM D 2665 &ASTM F 480. Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company. FO-SUB-PVC-DWV (8-3-15) Tube Fittings • Valves COPPER TUBE FOR PLUMBING AND MECHANICAL APPLICATIONS Job Name Job Location Engineer Product Description: Contractor Wholesaler Streamline® Streamline° CopperTube for use in plumbing and mechanical applications. Available sizes (Type K, L, M, & DWV) ranging from "to 8" in diameter. All tube shall be manufactured in the United States. Material: Streamline° CopperTube shall be made from material in compliance with ASTM B75 and of UNS C 12200 grade of copper. Key Specifications: Streamline° CopperTube (Type K, L, M) shall conform to the NSF/ANSI 61 Annex G requirements and is manufactured to meet ASTM 1388. Copper drainage tube (DWV) is made to meet ASTM 13306. Copper refrigeration coils, ACR/Nitrogenized straight lengths and line sets are made to meet the chemical, mechanical, cleanness and eddy current testing requirements of the applicable specifications of ASTM 13280. Installation: Installations shall comply with the latest applicable building codes for the local jurisdiction. For detailed installation instructions, consult the Copper Developement Association at copperorg. References: ASTM B75 Seamless CopperTube C 12200 99.9% Pure Copper (can be used for potable water) NSF/ANSI 61 Annex G Safe Drinking Water Act (third party certification) ASTM B88 Seamless Copper Water and Gas Tube (Type K, L, M) ASTM B280 Seamless CopperTube for Air Conditioning and Refrigerants ASTM B306 Seamless Drainage Tube Code (DWV) Tube Fittings • Valves COPPER TUBE DATA Streamline° Copper Tube sets the standard for quality, consistency and service in the plumbing industries. With a full line of copper tube products to support most all plumbing supply and DWV applications, Streamline° Copper Tube is available in all common types including Type K, Type L, Type M and DWV. Each piece of tube is incised marked and color coded for easy, long lasting identity. Manufactured in accordance with applicable standards, our ongoing commitment to quality continues to make Streamline° Copper Tube the preferred and specified brand of industry professionals. TYPE K RATED WORKING PRESSURE PSIG NOM. DIA. WT/FT FT/BNDL WALL I SOT 200T 300°F 400°F 1 /4 0.145 500 0.035 913 860 842 537 3/8 0.269 500 0.049 960 904 885 565 1 /2 0.344 500 0.049 758 713 698 446 5/8 0.418 200 0.049 626 589 577 368 3/4 0.641 200 0.065 724 682 668 426 1 0.839 100 0.065 557 524 513 327 1 1 /4 1.04 100 0.065 452 425 416 266 1 1 /2 1.36 100 0.072 420 396 387 247 2 2.06 - 0.083 370 348 341 217 2 1 /2 2.93 - 0.095 338 319 312 199 3 4.00 - 0.109 328 308 302 193 3 1 /2 5.12 - 0.120 31 1 293 286 183 4 6.51 - 0.134 306 288 282 180 5 9.67 - 0.160 293 276 270 172 6 13.90 - 0.192 295 277 271 173 8 25.90 - 0.271 314 295 289 184 TYPE L 1 /4 0.126 500 0.030 775 729 714 456 3/8 0.198 500 0.035 662 623 610 389 1 /2 0.285 500 0.040 613 577 565 361 5/8 0.362 200 0.042 537 505 495 316 3/4 0.455 200 0.045 495 466 456 291 1 0.655 100 0.050 420 395 387 247 1 1 /4 0.884 100 0.055 373 351 344 219 1 1 /2 1.14 100 0.060 347 327 1 320 204 2 1.75 - 0.070 309 291 285 182 2 1 /2 2.48 - 0.080 285 269 263 168 3 3.33 - 0.090 270 254 248 159 3 1 /2 4.29 - 0.100 258 243 238 152 4 5.38 - 0.110 249 235 230 147 5 7.61 - 0.125 229 215 211 135 6 10.2 - 0.140 213 201 196 125 8 19.3 1- 0.200 230 216 212 135 Tables give computed allowable stress for annealed copper tube of indicated temperature. Tube Fittings • Valves COPPER TUBE DATA ram/»Im ;Zr0=191'1JL•7;1AIZM;J;7*3-1U:7=1111lrtll NOM. DIA. WT/FT FT/BNDL WALL I50°F 200°F 300°F 400T 3/8 0.145 500 0.025 485 456 447 285 1 /2 0.204 500 0.028 420 395 387 247 3/4 0.328 200 0.032 346 326 319 204 I 1 0.465 100 0.035 286 270 264 169 1 1 /4 0.682 100 0.042 287 271 265 169 1 1 /2 0.94 100 0.049 282 265 259 166 2 1.46 - 0.058 254 239 234 149 2 1 /2 2.03 - 0.065 233 219 215 137 3 2.68 - 0.072 215 203 199 127 3 1 /2 3.58 - 0.083 214 202 197 126 4 4.66 - 0.095 213 201 197 126 5 6.66 - 0.109 198 186 182 116 6 8.92 - 0.122 186 175 171 109 8 16.5 - 0.17 195 183 180 1 15 Table give computed allowable stress for annealed copper tube at indicated temperature. TECHNICAL DATA Values of allowable internal working pressure for copper tube in service are based on the formula from ANSI B31, Standard Code for Pressure Piping: 2Stm P= Dmax -0.8tm P = Allowable Pressure S = Allowable stress T = Wall thickness D Max = Outside Diameter @ 150°F S = 5100 PSIG annealed @ 200°F S= 480OPSIG annealed @ 300°F S= 4700 PSIG annealed @ 400°F S= 3000 PSIG annealed All ratings listed fortypes K, L, M, DWV and refrigeration service tube in the preceding charts are calculated fortube in the annealed condition. These values should be used when soldering, brazing or welding is employed for joining components in a system. While the ratings for hard drawn tube are substantially higher, they should only be used for systems using properly designed flare or compression mechanical joints, since joining by any heating process might anneal (soften) the tube. In designing a system, careful consideration should also be given to joint ratings as well as those of the components. Tube Fittings • Valves COPPER TUBE AND SOLDER TYPE FITTINGS 1. Cut tube square with the cutter or fine hack = It . 1. Cut tube to length & remove saw (32 tooth blade is recommended). burr with file or scraper. Remove Burr. 2. Clean outside end of copper tube thoroughly with sand cloth or sandpaper equal depth of fitting. Leave no dark spots. 2. Clean outside of tube with 3. Clean inside of fitting carefully to tube stop with sandpaper or sand cloth. wire brush. Note: Sand cloth or sandpaper may also be used. �J 4. Using a brush, apply light uniform coat of soldering flux to the outside of the tube and inside of the fitting. 3. Clean inside of fitting with wire brush, sand cloth or sandpaper. 5. Slip tube into fitting to tube stop. Turn tube back and forth once or twice to distribute flux evenly. 6. Apply heat uniformly around the fitting with 4. Apply flux thoroughly to torch. When solder melts upon contact with inside of fitting. heated fitting, the proper soldering temperature has been reached. Remove flame and feed r' solder slightly off center at the bottom of the joint. Proceed across the bottom of the fitting and up to the top center position. Return to the starting point, and then proceed up the 5. Apply flux thoroughly to incomplete side to the top, again, overlapping outside of tube - assemble the solder metal. Wipe off surplus solder with tube and fitting. a piece of cloth. CAUTION: No not overheat the joint or direct the flame into the face of the fitting cup. Overheating could burn the flux, 6. Apply heat with torch.When which will destroy its effectiveness and the solder melts upon contact with solder will not enter the joint properly. heated fitting, the proper temp for soldering has been reached. Remove flame & feed solder to the joint at one or two points until a ring of solder appears at the end of the fitting. Mueller Streamline Co. 8285 Tournament Drive, Suite 150 Memphis, TN 38125 P 901.753.3200 STANDARD COPPER TUBE Mueller Copper Tube products are manufactured in the USA. All tubing produced in Fulton, MS, and Wynne, AR, is seamless and of UNS C12200 grade of copper and is manufactured to meet the chemical, mechani- cal, cleanness, and eddy current testing requirements of the applicable ASTM specifications set forth below. Although Mueller Copper Tube strives to meet all requirements specified in ASTM, Standard Tube may not fully meet ASTM dimensional requirements. Standard Tube will be provided unless Certified Tube is clearly defined on the Purchase Order. When specified at order placement, Mueller Copper Tube can supply Certified Tube to meet all requirements of the current applicable ASTM specification, at an additional cost. • Streamline Copper Water Tube (Types K,L,M) is produced in accordance with, ASTM B88 and ANSI/ NSF 61 * * • Streamline Copper Refrigeration Service Coils are produced in accordance with ASTM B280 • Streamline Nitrogenized ACR Hard Drawn Copper Tube is produced in accordance with ASTM B280 • Streamline Copper Drainage Tube (DWV) is produced in accordance with ASTM B306 • Oxygen & Medical Service Tube - To ASTM B819 (Types K & L) Hard Drawn Straight Lengths Only in accordance to CGA Cleanness Specification; CGA G4.1 (Compressed Gas Association); & NFPA 99 (Health Care Facilities). * * NSF 61 Restriction Statement Copper Tube (Alloy C12200) is certified by NSF to ANSI/NSF Standard 61 for public water supplies meeting or in the process of meeting the U.S. EPA Lead and Copper Rule (56FR 26460, June 7, 1991). Water supplies with pH less than 6.5 may require corrosion control to limit copper solubility in drinking water." Last revision: March 11, 2011 A COMPANY OF MUELLER INDUSTRIES M Uponor AquaPEX° Blue uponof Submittal information Revision F: Feb. 14, 2017 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Standard grade hydrostatic ratings (PPI): Crosslinked polyethylene PEX-a Engel method; PEX 5206 200T at 80 psi (93°C at 5.5 bar) 180T at 100 psi (82'C at 6.9 bar) 73.4°F at 160 psi (23'C at 11 bar) Linear expansion rate: 1,10'710°F1100' (27.94m m15.56`C130.48 m ) Product information and application use Uponor AquaPEX° Blue tubing is used primarily in cold potable - water distribution systems, but can also be used in radiant heating and cooling systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing. ✓ Description Part number I.D. 0.D. Weight ❑ M." Uponor AquaPEX Blue, 100-ft. coil F3040500 0.475" 0.625" 6 lbs. ❑ '/z" Uponor AquaPEX Blue, 300-ft. coil F3060500 0,475" 0.625" 18 lbs. ❑ ''/2" Uponor AquaPEX Blue, 1,000-ft. coil F3120500 0.475" 0.625" 54 lbs. ❑ 34" Uponor AquaPEX Blue, 100-ft. coil F3040750 0.671" 0.875" 10 lbs. ❑ 34" Uponor AquaPEX Blue, 300-ft. coil F3060750 0.671" 0.875" 34 lbs. ❑ 34" Uponor AquaPEX Blue, 500-ft. coil F3100750 0.671" 0.875" 54 lbs. ❑ 1" Uponor AquaPEX Blue, 100-ft. coil F3041000 0.862" 1.125" 20 lbs. ❑ 1" Uponor AquaPEX Blue, 300-ft. coil F3061000 0.862" 1.125" 56 lbs. ❑ 1" Uponor AquaPEX Blue, 500-ft. coil F3101000 0.862" 1.125" 93 lbs. Installation Approved fitting system is ProPEX°.1 Refer to the Uponor Professional Plumbing Installation Guide for additional information. Listings? cNSFus-pw; cQAlus; UL; CSA; WH; ETL; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC Codes ICC; ]PC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSIINSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CANIULC S102.2; ASTM E1191UL 263; CAN/ULC S101; ASTM E8141ULC 5115; AWWA C9043; CSA B137.5; CSA B214 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Radiant heating and cooling systems 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA T 800.321,4739 T 888.994.7726 F 952.891.2008 F 800,638.9517 uponorpro.com uponorpro.com 1ProPEX© is a registered trademark of Uponor Inc. ProPEX- is a trademark of Uponor Ltd.; 2Visit listing agency's website for complete information; 3For %" tubing and larger Uponor AquaPEX° Red Submittal information Revision F: Feb. 14, 2017 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved bv: Technical data Material: Crosslinked polyethylene PEX-a Engel method; PEX 5206 Standard grade 200T at 80 psi (93°C at 5.5 bar) Hydrostatic ratings (PPI): 180T at 100 psi (82°C at 6.9 bar) 73.4°F at 160 psi (23°C at 11 bar) Linear expansion rate: 1.10" M OT1100' (27.94mm15.56°C130.48m) Product information and application use Uponor AquaPEX` Red tubing is used primarily for hot potable -water distribution, but can also be used in radiant heating and cooling systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing. ✓ Description ❑ M" Uponor AquaPEX Red, 100-ft. coil ❑ '/z" Uponor AquaPEX Red, 300-ft. coil ❑ %" Uponor AquaPEX Red, 1,000-ft. coil ❑ 3/" Uponor AquaPEX Red, 100-ft. coil 0 3/" Uponor AquaPEX Red, 300-ft. coil 0 3/" Uponor AquaPEX Red, 500-ft. coil ❑ 1" Uponor AquaPEX Red, 100-ft. coil © 1" Uponor AquaPEX Red, 300-ft. coil ❑ 1" Uponor AquaPEX Red, 500-ft. coil Installation uponof Part number I.D. O.D. Weight F2040500 0.475" 0.625" 6lbs. F2060500 0.475" 0.625" 181bs. F2120500 0.475" 0.625" 541bs. F2040750 0,671" 0.875" 10lbs. F2060750 0.671" 0.875" 34 ibs. F2100750 0.671" 0.875" 541bs. F2041000 0.862" 1.125" 20lbs. F2061000 0.862" 1.125" 561bs. F2101000 0.862" 1.125" 931bs. Approved fitting system is ProPEXO1. Refer to the Uponor Professional Plumbing Installation Guide for more information. Listings2 cNSFus-pw; cQAlus; UL; CSA; WH; ETL; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSIINSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CANIULC S102.2; ASTM Ell 191UL 263; CAN/ULC S101; ASTM E8141ULC S115; AWWA C9043; CSA B137.5; CSA B214 Related applications PEX-a plumbing systems Radiant heating and cooing systems Contact information Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA T 800,321.4739 F 952.891.2008 uponorpro.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA T 888.994.7726 F 800.638.9517 uponorpro.com 1ProPEX5 is a registered trademark of Uponor Inc. ProPEXT" is a trademark of Uponor Ltd.; 2Visit listing agency's website for complete information; 3For 3/" tubing and larger Uponor AquaPEX°White, Coils Uponor Submittal Information Revision K: Dec. 7, 2015 Project Information Job Name: Location: Part No. Ordered; Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5106 Standard Grade Hydrostatic 200°F (931C) at 80 psi (551 kPa) .., Ail - Ratings (PPI): 180°F (82°C) at 100 psi (689 kPa) _- 73.4-F (23°C) at 160 psi (1,103 kPa) 4 -- 1/2", 3/4", 1", 1T/4% 11/z" and 2" Uponor AquaPEX=' White only: -- 120°F (49°C) at 130 psi (896 kPa) Linear Expansion Rate: 1.1"/100F/100' (27.94mm/5.56°C/30.48m) Product Information and Application Use Uponor AquaPEX White is used for hot and cold domestic potable water distribution and residential fire " safety as well as radiant heating/cooling and hydronic piping systems containing no ferrous corrodible components or where ferrous components are isolated from the piping. ✓ Description Part Number I.D. O.D. Weight ❑ 1/4" Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. ❑ 3/6" Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. ❑ 3/e" Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. ❑ 1/2" Uponor AquaPEX White, 100-ft. coil F1040500 0.475" 0.625" 6.0 lbs. ❑ 1/7" Uponor AquaPEX White, 300-ft. coil F1060500 0.475" 0.625" 18.0 lbs. ❑ 1/2" Uponor AquaPEX White, 500-ft. coil F1100500 0.475" 0.625" 27.6 lbs. ❑ 1/2" Uponor AquaPEX White, 1,000-ft. coil F1120500 0.475" 0.625" 54.0 lbs. ❑ 5/s" Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. ❑ 5/e" Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. ❑ 3/4" Uponor AquaPEX White, 100-ft. coil F1040750 0.671" 0.875" 10.0 lbs. ❑ 3/4" Uponor AquaPEX White, 300-ft. coil F1060750 0.671" 0.875" 34.0 lbs. ❑ 3/4" Uponor AquaPEX White, 500-ft. coil F1100750 0.671" 0.875" 54.0 lbs. ❑ 1" Uponor AquaPEX White, 100-ft. coil F1041000 0.862" 1.125" 20.0 lbs. ❑ 1" Uponor AquaPEX White, 300-ft. coil F1061000 0.862" 1.125" 56.0 lbs. ❑ 1" Uponor AquaPEX White, 500-ft. coil F1101000 0.862" 1.125" 93.0 lbs. ❑ 11/4" Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. ❑ 11/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. ❑ 11/z" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 44.0 lbs. ❑ 11/2" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 133.0 lbs. ❑ 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. ❑ 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. ❑ 2" Uponor AquaPEX White, 300-ft. coil F1022000 1.629" 2.125" 204.6 lbs. ❑ 21/z" Uponor AquaPEX White, 100-ft. coil E1062500 2.011" 2.625" 88.0 lbs. ❑ 21/2" Uponor AquaPEX White, 300-ft. coil F1022500 2.011" 2.625" 264.0 lbs. ❑ 3" Uponor AquaPEX White, 100-ft. coil F1063000 2,400" 3.125" 128.0 lbs. ❑ 3" Uponor AquaPEX White, 300-ft. coil F1023000 2.400" 3.125" 384.0 lbs. Installation Use ProPEXk' fittings for 3/s" through 3" pipe.' Refer to the Uponor Professional Plumbing Installation Guide, Complete Design Assistance Manual (CDAM), Hydronic Piping Design Assistance Manual (HPDAM) or AquaSAFF'" Residential Fire Sprinkler Installation Guide for more information. EListingsZ Codes Standards cNSFus-fs3; cNSFus-pw; cQAIus P321; IAPMO; ICC; IPC; IMC; ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; UL; CSA; ETL; PPI TR-4; ICC-ES; BMEC; IRC; UPC; UMC; NSPC; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CCMC HUD; UFGS; NPC of CAN/ULC S101; ASTM E814/ULC S115; CSA B137.5; CSA B214; Canada; NBC of Canada UL 18213; ULC/0RD-C199P3; AWWA C9044 Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. AquaSAFET"' Fire Safety Systems 5925 1481" Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Radiant Heating and Cooling Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Hydronic Piping Systems Phone: 800.321.4739 Phone: 888.994.7726 Fax:952.891.2008 Fax:800.638.9517 www.uponorpro.com www.uponorpro.com 'ProPEX`�' is a registered trademark of Uponor, Inc. ProPFX'" is a trademark of Uponor Ltd. 'Visit listing agency's website for complete information. 'For '/2", 3/4", 1", 1l/4% 11/2" and 2" pipe only. "Far V4" to 3" pipe.