Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-1369_Manufacturer_Specifications_and_Installation_Instructions_10.6.2021_8.34.12_AM_2446905
AmwC" s*vda,rd TAG NOTE: All dimensions are in mm/inches. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED 50 ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (I-1/8) DIA. WITH 22.2 (7/8) DIA. HOLE IN CONTROL 80X BOTTOM FOR ELECTRICAL) POWER SUPPLY LIOUID LINE SERVICE? VALVE, "E" I.D. FEMALE H T BRAZE CONNECTION F WITH 1/4 " SAE FLARE PRESSURE TAP FIT TI NGS I I 1 FIG. 1 K.O. FOR ALTERNATE ELECTRICAL ROUTING AS LINE 1/4 TURN BALL SERVICE VALVE, "D" .D. FEMALE BRAZED CONNECTION WITH I/4 SAE L ARE PRESSURE TAP FITTING. From Dwg.21 D152862 Rev. 18 4A7A3030-SUB-102.00 2-1/2 Ton Split System Cooling — 1 Phase 4A7A3030A Product Specifications OUTDOOR UNIT (i ( 4A7A3030A1000A POWER CONNS. — V/PH/HZ 200/230/1/60 MIN. BRCH. CIR. AMPACITY 15 BR. CIR. l MAX. (AMPS) 25 PROT. RTG. f MIN. (AMPS) 20 COMPRESSOR DURATION TNN NO. USED - NO.SPEEDS 1-1 VOLTS/PH/HZ 200/230/1/60 R.L. AMPS O - L.R. AMPS 11.1 - 63 FACTORY INSTALLED START COMPONENTS O YES INSULATION/SOUND BLANKET YES COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 23 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. ® 3160 NO. MOTORS - HP 1 - 1/8 MOTOR SPEED R.P.M. 825 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.7 OUTDOOR COIL — TYPE SPINE FIN TV ROWS - F.P.I. 1 - 24 FACE AREA (SQ. FT.) 18.75 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410 (Q.D. UNIT) © 5 LBS., 11 OZ. FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 3/4 LINE SIZE - IN. O.D. LIQ. © 5/16 CHARGING SPECIFICATION SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 38 x 30.1 x 33 WEIGHT SHIPPING (LBS.) 217 NET (LBS.) 190 Certified in accordance with the Air -Source Unitary Air -Conditioner Equipment certification program, which is based on ARI standard 210/240. ® Rated in accordance with ARI standard 270 O Calculated in accordance with Natl. Elec Codes. Use only HACR circuit breakers or fuses. © Standard Air — Dry Coil — Outdoor 05 This value approximate. For more precise value see unit nameplate. © Max. linear length 60 ft., Max. lift - Suction 60 ft.; Max lift - Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0' (' denotes latest revision). O This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. ( No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. MODELS 113ASEIFIG.1 A I B I C I D I E I F I G I H I J I K 14A7A3030AI 3 1 1 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 1 5/16 1143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) A -weighted Sound Power Level [dB(A)] MODEL SOUND POWER LEVEL [dB(A)] A -WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] 63 1 125 1 250 1 500 1 1000 1 2000 1 4000 1 8000 4A7A3030A1 76 49.3 1 61.1 1 66.2 1 70.3 1 70 1 67.4 1 58 1 51.6 Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI) © 2006 American Standard Inc. All Rights Reserved Mechanical Specification Options General The 4A7A3 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit is UL listed. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather -resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weather- proof CMBP-G30 DuraTuffT°" base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The ClimatuW compressor features a 10 year limited warranty, internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. I AP ■a\\ p MANC ER CERT.FIEp Amftfaw S*odard Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40' F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30' F. Accessories Thermostats — Cooling only and heat/cooling (manual and automatic changeover). Sub -base to match thermo- stat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. 8/06 American Standard Inc. 62007roup Highway American Standard has a policy of continuous product and product data improvement and it reserves the right Tyler, Texas 75711 to change design and specifications without notice.