BLD2021-1398_Manufacturer_Specifications_and_Installation_Instructions_10.11.2021_6.49.08_AM_2454275127A PREFERRED'.. SERIES 2-STAGE AIR CONDITIONER Er:y, a At WITH PURONO REFRIGERANT 2 TO 5 TONS PRODUCT DATA Preferred TM Puron - Bryant Air Conditioners with Puron o refrigerant provide a collection of features unmatched by any other family of equipment. The 127A has been designed utilizing Bryant's Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. This product has been designed and manufactured to meet Energy Star@ criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy StarO guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahiidirectory.org) for the most up-to-date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Efficiency • Up to 17.0 SEER / Up to 13.0 EER • Microtube Technology'" refrigeration system • Indoor air quality accessories available Sound • Sound level as low as 72 dBA Comfort • System supports Thermidistat- or standard 2-stage thermostat controls Reliability • Puron° refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Front -seating service valves • 2-stage scroll compressor • Internal pressure relief valve • Internal thermal overload • Low pressure switch • High pressure switch • Filter drier • Balanced refrigeration system for maximum reliability Durability Duragaurd Plus" protection package: • Solid, Durable sheet metal construction • Steel louver coil guard • Baked -on, complete outer coverage, powder paint Applications • Long -line - up to 250 feet (76.2 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) • Low ambient cooling (down to 0°F /-17.8°C ) with approved low ambient accessory kits. MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 7 A N A 0 3 6 0 0 0 A Product Tier SEER Major Voltage Variations Cooling Capacity Design Not Open Minor Family Series Variation Defined Series 1=AC 2= 7=17 N= A = Standard Preferred SEER 208-230-1 or 208/230-1 Puron V I a 1. 0_ c UL us Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the This product has been designed and manufactured to r0 meet Energy Star% criteria for energy efficiency when program For verification , matched with appropriate coil components. However, of certification for individual proper refrigerant charge and proper air flow are critical products, go to ISO 9001 to achieve rated capacity and efficiency. Installation of www.ahridirectory.org. his product should follow all manufacturing refrigerant ry'Or g QMI-SAI Global charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES FEATURES Unit Size — Series 024—B 036—B 048—B 060—C Puron Refrigerant X X X X Maximum SEER Rating* 17.0 17.0 17.0 16.0 2—Stage Scroll Compressor X X X X Low Ambient Cooling Capability with Approved Kits X X X X Crankcase Heater w/Temperature Switch O O X X Louvered Coil Guard X X X X Field Installed Filter Drier X X X X Front Seating Service Valves X X X X Internal Pressure Relief Valve X X X X Internal Thermal Overload X X X X Long Line capability X X X X Low Pressure Switch X X X X High Pressure Switch X X X X X = Standard O = Accessory * With approved combinations 701 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron® Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/TXV AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Vertical Separation ft (m) 0-5 (0-1.6) 6-10 (1.8-3.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 1/4 75 75 75 50 50 -- -- -- -- 024 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 5/16 175 150 150 100 100 100 75 -- -- 036 3/8 3//8 250* 250* 250* 250* 250* 1 250* 250* 250* 250* 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- O60 3/8 3/8 250* 250* 250* 225* 190 150 110 -- -- * Maxi u actual length not to exceed 200 a (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/TXV AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.8) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 161-175 (46.0-53.3) 176-200 (53.6-61.0) 1/4M2550** 125 175 200 225* 250* 250* 250* 024 3/8 5116250* 250* 250* 250* 250* 250* 250* 3/8250* 250* 250* 250* 250* 250* 250* 5/16250* 250* 250* 250* 250* 250* 250* 036 3/8 3/8250* 250* 250* 250* 250* 250* 250* 048 3/8 3/8250* 250* 250* 250* 250* 250* 250* 060 3/8 3/8250* 250* 250* 250* 250* 250* 250* *,MaX1mwWactuaI length not to exceed 200 ft (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Chapin¢ Formula: [(Lineset oz/ft x total length) — (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4" liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) — (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) — (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21.1°C to 26.7°C), and outdoor temperature must be 70*F to 100°F (21.1 °C to 37.8°C). If outside these conditions, adjust charge for long line sets by weigh-in method. LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m) AC with Puron® Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within al- lowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Residential Piping and Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 2-Stage Air Conditioner Applications Unit Nominal Size (13tuh) Maximum Liquid Line Diameters (in. OD) Vapor Line Diameters (In.) OD Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 26-50 (7.9-15.2) 51-80 (16.6-24.4) 81-100 (24.7-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 161-175 (46.0-50.3) 176-200 (53.6-60.0) 201-225 (61.3-68.6) 226-250 (68.9-76.2) 5/8 0 1 1 2 3 3 4 4 5 024 3J8 3/4 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 7 9 10 11 036 3/8 3/4 0 0 1 1 2 2 3 3 4 7/8 0 0 0 0 1 1 1 1 2 3/4 1 2 2 3 4 5 6 7 7 048 3/8 7/8 0 1 1 2 2 2 3 1 3 3 1-1/8 0 0 — — — — — — - - O80 3/8 3/4 7/8 1 0 1 2 1 1 4 2 5 2 6 3 7 4 9 4 10 5 11 5 1-1/8 0 1 0 0 1 1 1 1 1 1 1 Applicati in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. ications in this area are not recommended due to insufficient oil return PHYSICAL DATA UNIT SIZE SERIES 024-B 036-B I 048-B 080-C Compressor Type Ultratech 2-Stage Scroll REFRIGERANT Purona (R-410A) Control TXV (Puron Hard Shutoff) Charge lb (kg) 6.64(3.01) 9.26 (4.20) 1 12.94 (5.87) 12.70 (5.76 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 2481 3068 4700 4700 Motor HP 1/12 1/10 1/4 1/4 Motor RPM 800 825 825 825 COND COIL Face Area (Sq ft) 19.38 19.38 25.12 25.12 Fins per In. 25 20 20 20 Rows 1 2 2 2 Circuits 5 7 7 7 VALVE CONNECT. (In. ID) Vapor 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 718 1-1/8 1-1/8 Liquid 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. ELECTRICAL DATA UNIT SIZE - SERIES V/PH OPER VOLTS* COMPR FAN MCA MAX FUSEL or CKT BRK AMPS MAX MIN LRA RLA FLA 024-B 208-230/1 253 197 58.3 11.1 0.6 14.5 20 036-B 83.0 15.3 0.7 19.8 35 104.0 21.2 1.3 27.8 40 060-C 152.9 28.8 1.3 37.3 60 \4_E2LmIss'QWIimits of the voltage range at which the unit will operate satisfactorily t Time -Delay fuse. FLA - Full Load Amps LRA -Locked Rotor Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps NOTE: Control circuit is 24-V on all units and requires external power source. All motors/compressors contain internal overload protection. Complies with 2010 requirements of ASHRAE Standards 90.1 A -WEIGHTED SOUND POWER LEVEL Copper wire must be used from service disconnect to unit. UNIT SIZE -VOLTAG E,SERI ES STANDARD RATING (dBA) TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 126 250 600 1000 4000 8000 024-B 73 - High Stage 49.0 58.0 66.5 69.5 61.0 57.5 74 - Low Stage 52.0 59.5 67.0 69.5 61.0 55.0 036-B 74 - High Stage 53.5 61.5 68.0 71.0 62.5 57.5 73 - Low Stage 54.0 61.5 67.5 68.0 63.0 56.0 048-B 74 - High Stage 54.5 59.5 67.0 68.0 60.0 53.5 72 - Low Stage 55.5 61.5 67.0 66.0 60.5 55.0 060-C 75 - low stage 71.0 70.0 69.0 70.0 63.0 60.0 74 - high stage 69.0 68.0 69.0 71.0 61.0 59.0 NOTE: TeiT d A-aeclbrdance with AHRI Standard 270-95. (Not listed with AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE -VOLTAGE, SERIES REQUIRED SUBCOOLING °F (°C) 024-B 10(5.6) 036-B 14(7.8) B 13(7.2) - 14(7.8) THERMOSTATS PART NUMBER PROGRAM GAS ELECTRIC HEAT COOL T6-PAC01 7-Day J J 1 1 T6-NAC01 NP J J 1 1 THERMOSTAT ACCESSORIES PART NUMBER BRIEF DESCRIPTION THERMOSTATS USED WITH SYSTXBBRRS01 Indoor Remote Room Temperature Sensor All T6- thermostats T6-EXP01-A ExPa Computer Programming Accessory T6-P thermostats TSTATXXCNVI Ot Thermostat Conversion Kit (4 to 5 wire) - 10 pack All Bryant(D branded thermostats TX-LBP01 Large Decorative Backplate T6-Pxx, T6-Nxx, and T2-Pxx TSTATXXSEN01-B Outdoor Air Temperature Sensor All T6- thermostats # Available through RCD ACCESSORIES ORDER NUMBER DESCRIPTION 024-B 036-B 048-B 060-C KAACH1701AAA CRKC HTR KIT X X S S KAALS0201 LLS SOL VALVE KIT X X X X KAAWS0101AAA WINTER ST KIT X X X KSAFT0101AAA FRZTHERM KIT X X X X KSAHS2501AAA HARD START KIT X X KSAHS2801AAA HARD START KIT X X KSALA0301410 LOW AMBIENT KIT X X X X KSASF0101AAA SPRT FEET KIT X X X X KSASH2301COP SOUND BLKT KIT X X KSASH2401COP SOUND BLKT KIT X X A = accessory a= aianuaw * Not backward compatible to previous series. ACCESSORY USAGE GUIDELINE Required for Low Ambient Required for Long Line Required for Sea Coast Accessory Cooling Applications Applications Applications (Below 55° F / 12.8'C) (within 2 miles/3.2 km) Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes (standard on some units) Yes (standard on some units) No Evaporator Freeze Thermostat Yes No No Yes Yes Yes Hard Shutoff TXV (standard w/factory approved (standard w/factory approved (standard w/factory approved indoor unit) indoor unit) indoor unit) Liquid Line Solenoid Valve No See Residential Piping and Long Line Guideline No Low -Ambient Pressure Switch Yes No No Support Feet Recommended No Recommended Winter Start Control Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 35 ft. (10.7 m) vertical differential, refer to Residential Piping and Longline Guideline. Accessory Description and Usage (Listed Alphabetically) 1. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for 2-stage non -communicating units in the following applications: - Long line - Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 2. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 3. Evaporator Freeze Thermostat An SPST temperature -actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 4. Low -Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low -ambient temperatures down to 0°F (-17.8*C) when properly installed. Usage Guideline: A Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 557 (12.8°C). 5. Support Feet Four stick -on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 6. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. 7. Winter Start Control This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. 6 J DIMENSIONS OPERATING SHIPPWG SHIPPING SHIPPWG Fj,EplplCp� A B C D E F G H 1 3 K WEIGHT WEIGHT LENGTH/WIDTH HEIGHT UNIT SERIES OxARACTEMTICS (Sq.) INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MMEL INCH MM LOS K S Lbs K S INCH MM INCH MM 127ANA024000DBAA B Y N N N 31 3116 792.5 35 12 901.4 314 19.1 6 9/16 166.1 2411/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 16 406.4 16 118 409.6 183 83.0 222 100.7 33 5116 846.6 40 1015.8 127ANA036000DBAA B Y N N N 31 3116 792.5 35 112 901.4 7/8 22.2 6 9116 166.1 2411116 626.3 9 118 231.3 5116 7.9 3 76.2 15 314 400.1 15 381.0 216 98.0 255 115.7 33 51 6 846.6 40 1015.8 127ANIU148000DBAA B Y N N N 35 889.0 38 718 987.8 7/8 222 6 9/16 166.1 28 7/16 722.8 9 1/8 231.3 5/16 7.9 3 76.2 18 112 469.9 17 431.8 277 125.6 316 144.2 37 1/B 943.1 43 3/8 1102.2 127AW60BOODCAA C Y N N N 35 889.0 38 718 987.8 718 22.2 6 9116 166.1 28 7/16 722.8 9 1/B 231.3 5/16 7.9 3 76.2 17 314 450.9 17 431.8 281 127.5 323 146.5 37 1/8 943.1 43 3/8 1102.2 N=NO A SO. AIR DISCHARGE FIELD POWER SUPPLY CONN. 7/8'(022.2) HOLE WITH 1/B'(028.61 KNOCKOUT FIELD CONTROL SUPPLY CONN. ¢ 7/6'($22.2) HOLE 0311*1 LIOUID LINE CONN. K 3 31A' 3 1/2' (9101 1 81 0 CVAPOR LINE CONN.I hY SO. 13/16" I(� X Y NOTE: ALL DIMENSIONS IN INCH (MM) (71.0) ..... ... U.S. ECCN: Not Su iect to Repuiation (N.S.R.) 00 CLEARANCES 24" (609.6) Service 24" (609.6) Wall 6" 52.4 r 12" (304.8) 24" (609.6) Service Clearances (various examples) 12" (304.8) 24" (609.6) Wall 24" (609.6) Service Wall 24" Service 12" 6" � (304.8) 152.4) 12" (304.8) 24" (609.6) 24" (609.6) Service Note: Numbers in () = mm IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re -circulation of discharge air. A07833 TESTED AHRI COMBINATION RATINGS NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Bryant database at: www.MyBryantRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at: http:/Irpmob.wrightsoft.com/ Model Number Indoor Model AHRI STANDARD RATINGS — COOLING Capacity EER SEER ID SCFM High Low High I Low 127ANA024****B CNPV*3117AL* 25000 21200 12.2 14.0 800 680 127ANA036****B CAP**3721AL* 36800 30200 12.2 14.0 1050 840 1 ****B CAP**6124AL* 49000 40500 12.5 15.0 1400 1120 127ANA060B***C I CAP**6124AL* 1 58500 44500 14.5 12.0 1625 1300 AHRI —Air Conditioning, Heating & Refrigeration Institute EER —Energy Efficiency Ratio — 80°F (26.6°C) indoor db/670F (19.4°C) indoor wb & 950F (35°C) outdoor wb. SEER —Seasonal Energy Efficiency Ratio TDR —Time—Delay Relay. Inmost cases, only 1 method should be used to achieve TDR function. Using more than i method in a system may cause degradation in performance. Use either the accessory Time —Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not Included. 2 Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data In fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are affected.