Loading...
ENG2021-0399 ROW PERMITRIGHT OF WAY MINOR PERMIT PERMITNUMBER, City of Edmonds 121 5th Ave N, Edmonds WA 98020 ENG2021 -0399 www.cityofedmonds.gov Description: POTHOLE AT 6 LOCATIONS FOR CITY'S PHASE 9 SEWER REPLACEMENT ISSUED: 10/12/2021 Address: 121 5TH AVE N EDMONDS WA 98020 EXPIRES: 04/12/2022 Permit Type: RIGHTOF WAY MINOR Permit Subtype: CITY Parcel Number: 00434400100300 NAME TYPE NAME ADDRESS PHONE APPLICANT APPLIED PROFESSIONAL SERVICES 43530 SE NORTH BEND WAY, NORTH BEND WA 98045-9289 (425)888-2590 INC. CONTRACTOR APPLIED PROFESSIONAL SERVICES 43530 SE NORTH BEND WAY, NORTH BEND WA 98045-9289 (425)888-2590 INC. OWNER EDMONDS CITY OF 250 5TH AVENUE N, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 RIGHT OF WAY MINOR PERMIT FEE $110.00 $0.00 THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 10/12/2021 RELEASED BY // DATE Printed: Tuesday, October 12, 2021 12:03:41 PM 1 of 2 WAY MINOR .UM PERMIT City of • • • www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND OR NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS RESULT INSPECTION MEN X-2 ENGINEERING FINAL** Printed: Tuesday, October 12, 2021 12:03:41 PM 2 of 2 ENG2021-0399 ofEpMO4o� RECEIVED RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION OCT 07 2021 Complete and submit this Application in accordance with the Submittal. /'V . i s`0 Re Right -of -Way Requirements outlined in permit Handout E6�. CITY EMONDS q -p DEVELOPMENT OPP MENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving ular1n. All fields required. Incomplete Applications will be denied. SECTION A General • Project Name City of Edmonds Phase 9 Sewer Replacement Site Address or if no site address use Property Address at NW corner of project area: 76 t h Ave W & 2 3 9 t h P 1 SW Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of Company Franchise Ordinance No: Point of Contact Title Address City State Zip Phone Email Contractor and Authorized Agent of Owner (see note below) Name ofCompany A lied Professional Services Contractor Contacts During Construction Primary Name John Gardin Agent Name John Gardin 'title Division Manager Title Vacuum Division Manager Mobile (425) 864-5547 Address 43530 SE North Bend WaV Email johncr@a-pslocates.com City North Bend I State WA Z'p 98045 Secondary Name JOhnathan Gohlke Phone (425) 888-2590 Title Project Manager Email johngLdapslocates.com Mobile (206) 920-3277 City of Edmonds Business License NO:NR— O 14 5 5 9 Email jdq@apslocates.com State License No: A P P L I P S 9 81 L D ❑ Contractor verifies it is currently bonded i Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial X City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) APS to pothole existing utilities at 6 locations to obtain the depth and location for design. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ❑ power z gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes No x 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? x If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? x 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? x 5. Does the work involve proposed additions to an aboveground utility stem? If es: x Are the additions for the purpose of serving new commercial development? x Are the additions for the purpose of serving a single-family residential subdivision? x Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the x project is proposed: 6a. Does your project involve wires/cables/lines? If yes: x How many are existing? I I How many are to be added? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: *% APPLICANT PRINTED NAME: John Gardin APPLICANT TITLE: Vacuum Division Manager NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 10/7/2021 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROLAND DRAINAGE 3 E OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. PH3, 246 ft S of 239th Centerline. ExESTs5P'C STA A1+00 Confirm location of SS DE AT $T SS LAT-202. CONNECT TO EXIST SSMH 17-74 REMOVE EXIST GUT AND SSROMH bend. T P/L, TYP iDERE-CHANNEL Ixu rE wOoii��ooxc 25ft S f DNN MO UMENTHIR®MISIRYo S r �PI-11, 239th Centerline _ CAP AND ABAN E 8"SS IN PLACE, IST P 2 N o s z m c arrr _ - - __--e rr _ - - _- _- 0 �-_ C __� ccon xracr ar Aft om�nL+ 4 a s eL CLEANOLIT TABLE HOUSE NO. STREET STATION OFFSET OS 7610 239TH PL SW A2+30 21.6' RT O 23921 76TH AVE W A2+76 32.8' IT O3 24002 76TH AVE W A3+53 20.6' RT O4 24005 76TH AVE W A3+56 36.1' IT OS 24016 76TH AVE W A4+25 21.6' RT E T r _ -- E Pv C.rr- _— ---,r _ --\ —� r-- �E_G 6' - 7 xui.iob'.5 —� ` — -- _--�\---_—__--__ _—_ y -F 6"CI W- _-- —----6"CIW--_— — -6"0 W.—_—r + +_ --Do ------- _ _ 6'CI W - — —— `� — .� 'Z — ��R--- CsE.,oe.� �6, ` N \ �o as ws�iaFENT �, ice\ i I = iT�\ 76TH Y3VE W. d n a ry U 1. 2" PVC Applicant shall repair/replace all 6 £ i Ail, W " \6„�__--12.6D----=----='--� rsDa- L— a ----�-�-- ----, �D — Z w damage to utilities or frontage -- _ _" improvements in City right-of-way PROTECT EXIST -- \-�----- i a per city standards that is caused or MONUMENT , -r `\ \ \� _cx.vxuxx rtxaj A ONac a� �'u'. aEJ occurs during the permitted project. PH2, 136 ft S of CAP AND ABAN EXIST SSI 24� z�(((rz'9 / Ix�rl S 2ns�ir O 7606 � •\ \ rs- \ 1 IT IN PLACE, 11 I i 21 Ba �y6w a ¢ W zz� (rz'cavc) /�..... z/�s"cJ HUNDIIE BR.DON `eor co-r �A�NO) a�yry 239th Centerline 1- STA A3+73 KERNS E A TIO ,E S Ij —(1Q S s FURNISH & INSTALL: \ `,STA A1+32 i 1-SSMH PER CITY STD FURNISH &INSTALL: DET GU-421 /\> 1-SSMH PER CITY I 20 10 0 20 40 \� STD DET GU-421 STA A3+79 5' LT \ \ REMOVE EXIST BRICK \, PLAN' _ ✓ SSMH 17-75 SCALE IN FEET SCALED: 1-20' 315 310 305 300 295 290 285 oNN u Ri s s _-_--{T- i ___ -- C/L PIP H n v EX B COME H _________ ---- 4 w_-------------- 4 O 55 00 SLP=0.0 065 ________ ry SS H-148" r------ V STA___ A1+32 2 1 LF 12" p I _________ M t+ IE( N)12"(N)= 00.02 =0.03 6 W JE( UT)12"(S) 299.92 IE OUT 12" ( )=301.0 191 LF 2" PVC SS = ST A3+73 Q RI IE =298.37 N)12"(N)- 92.55 IE( UT)12"(S) 292.45 315 ENGINEERING DIVISION APPROVED AS NOTED 310 jdl LVQU,.n,t 10/12/2021 VV 305 RECEIVED 300 OCT 07 2021 295 290 CITY OF EDMONDS DEVELOPMENT zes SERVICES DEPARTMENT AO+80 Al+00 Al+20 Al+40 Al+60 Al+80 A2+00 A2+20 A2+40 A2+60 A2+80 A3+00 A3+20 A3+40 A3+60 A3+80 A4+00 A4+20 A4+40 A4+60 A4+80 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT 3 0% S U B M ITTA L NOTICE TED pR Ey 4yED* SITE1EET DESIGNED CITY OF EDMONDS 76TH AVE W - La RAMIN ETz7PHASE 9 SEWER PLAN & PROFILE C-1 IF THIS MR DOES NOT MEASURE V ]AM murraysmilh 'REPLACEMENT PROJECT STA Al+00 TO STA A4+80 THEN DRAWING IS NOTTOSEALECHECKED --------. Jr..,_o6 of XX SEE SHEET C-5 g4+00 TC", sTA PH5, 26 ft IN of CB, °A T=,. MA Q confirm location of bend INSTALL NEW 6" PVC LAT & � xurEzesis- RECONNECT EXIST SS PVC PER ,Yq\ PROTECT EXI CITY STD DET SS-202, MATCH EXIST SS LAT LOCATION AT P/L TAM V %r z " \_ \ TREES, T'P OR EASEMENT BOUNDARY, TYP a�,NNux �N N t,� � � /��\ AN EXTP D- z PH4 75ftIST F UNKNOWN %' C Of n6 00 1 ADDRESS p£ `A 1 1 J l.i aR0 I US POSTAL SERN�F- \I 'i -- CT EXIST B" W \I' - & VALVES, TYP STA B4+59- REMOVE EXIST SSMH 5-325 - _ _ FURNISH & INSTALL: B. PyC 1-SSMH PER CITY STD /w IW 0 S/W 'DI iN S/ W e DET GU-421 G- 1-INSIDE DROP CONNECT 8 PVC 11 111 PH6, 62ft N of CB .T EXIST 1 V" PE 1 U G P - , o TDI W. o�—v Di III, 5LW — — — — 8 PVC B7+00 — — PER CITY STD DET SS-22y— — — — PROTECT EXIST PH 3 6T VE W. 3 — I lO24"DIW DIW "DI W- - — _20. — UGP T -UG - .1 SD- UGF SD— -T .TUG 3^S _ W GP 12�5D— PROTECT EXIST 4"STW IPG1-1 STABS+28 _ MPreo= -zn N �I 1 I 102� - N STA B6+78 T2" 1 CON N ECT TO EXIST CITY �I (r(ai asn)c) i FURNISH &INSTALL: 1-SSMH PER CITY O - ( 1 Reference CB POPE 2I 2ss.s (ia•aivl 1 OF LVNNWOOD SSMH = STD DET GU ! (i2PM) {{ _c�; 11 RM i 1 u AAGLE CAP AND ABAN EXIST 8" SS IN PLACE °r a 16 1 NILSON - ;06 (12-1) E tli S eorzsoz eor T+e.i [ 1 1 (Peon ,ENT °.� r o di za to 4� f{ o nr� cxaN2 1 j . /� PLAN 1 PROTECT EXIST UGP ` 1 SCALE IN FEET J SCALE: 1"=20' 265 260 255 250 245 240 235 265 260 255 250 245 240 235 B4+00 B4+20 B4+40 B4+60 B4+80 BS+00 BS+20 85+40 B5+60 B5+80 86+00 B6+20 B6+40 B6+60 B6+80 B7+00 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE TED LY ` 4yED*DESIGNEDNIS�RDDES murraysm�rth HEN DUWINE I" ]AM NOTTOSCALEG IS CHECKEDBY REVISION �. 1B9 3 _; to 'h o + ; Izzi v $a2 v aWG _ EXI TGR@ C/ PIPE - ru� '� - �2w �LU - - - - _ w 8 LF 8" PVC SS SLP=0.0048 I Q8" CONC 5 _ _ _ _ 9 LF 8" PV 55 _ 142 LR-8'PV - - - - SLP=0.00 0 Lt ___ _-_ S P=0.0050 _ 'EX z4"CON 55 SSMH 148" 24' CONC I 5 IE 8" IN W)=246.7 L ---- SSMH 5-3 SP STA 5+28 STA B4+5 RIM= 54.50 RIM -257A 9 IE(IN 8"(SW)=2 7.67 SSM -248" IE(IN)8"( )=248.11 IE(0 )8"(N)=24 .5] STA 6+70 IE(IN)6"(S )=250.60(EXIST DR P) RIM 251.94 IE(OUT)8"( E)=248.0 IE(IP IE )=24 T " NE = .86 4 .] CLEANOUT TABLE HOUSE STREET STATION OFFSET ,,O. OI 18218 76TH AVE W B4+51 3.8' LT RECEIVED OCT 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 30% SUBMITTAL SITE 2 CITY OF EDMONDS 76TH AVE W - PHASE 9 SEWER PLAN & PROFILE C-6 REPLACEMENT PROJECT STA B4+00 TO STA B7+00 PRCECTNO.:20-2775.01 SCALE: AS SHOWN I D TE: SEPTEMBER 2021 11 of XX BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT I > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100, 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED 300' SIGN SPACING = X (1) RURAL HIGHWAYS 60 165 MPH 800't RURAL ROADS 45/55 MPH 500't RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350't RURAL ROADS, URBAN ARTERIALS, 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200't (2) URBAN STREETS 25 MPH OR LESS 100't (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ONE LANE . ROAD AHEAD 48" 48" 48" W20-4 48. W20-7A ROAD BE WORK PREPARED AHEAD TO STOP 48" 48" W20.1 W20-7111 W20.7B (OPTIONAL IF 40 MPH OR LESS) RECEIVED LEGEND OCT 07 2021 FLAGGING STATION b TEMPORARY SIGN LOCATION D CHANNELIZING DEVICES PROTECTIVE VEHICLE 50. TO 100' 6 DEVICE MIN I I R O RK AREA 59TO 100' 6 DEVICE W20-7A ONE LANE ROAD AHEAD� W20-4 W20_7B (OPTIONAL IF 40 MPH OR LESS) 481, 48' BE ROAD PREPARED WORK To STOPrr AHEAD 48" 48" 48. 48' Or . W20.713 ONE LANE W20.1 ROAD AHEAD 48" 48" W20-7A W20-4 BE PREPARED > W20-76 IONAL IF 40 MPH OR(OPTLESS) TO STOP 48' CHANNELIZATION DEVICE SPACING (FEET) MPH TAPER TANGENT 50/65 10 TO 20 60 35/45 10 TO 20 60 25/30 1 10 TO 20 40 W20-711 ENGINEERING DIVISION APPROVED AS NOTED 48' ROAD �0✓x��Q 10/12/2021 WORK > NOTES vv AHEAD 48' 1. ALL SIGNS ARE BLACK ON ORANGE. CITY OF EDMONDS ONE -LANE, TWO-WAY TRAFFIC CONTROL DEVELOPMENT WITH FLAGGERS SERVICES DEPARTMENT NOT TO SCALE 2. EXTENDING THE CHANNELIZING DEVICE TAPER ACROSS SHOULDER IS RECOMMENDED. 3. NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING AT FLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONS FOR ADDITIONAL DETAILS. 4. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS. Plot 1 TIME 3:05:14 PM s•"•s "WAS FED.AID PROJ.NO. .e " E Amokxnx � �I/ Washington State Department of Transportation .ss TC7� DATE 1/212018 PLOTTED BY Ildd.1f DESIGNED BY +". x... Ex sx.E. o. ENTERED BY CHECKED BY c"x.xnm x"wnox xo. TRAFFIC CONTROL PLAN PROJ. ENGR. REGIONAL ADM. REVISION DATE BY 7630 3/4" STW-U 1967 i vvv , 5/8" PE 1994 7615 p� 7623 199 PE 991 9 �L �Q �N 1q a 7610 N 5/8" MPE 2013-E 1STW-U 197970 7620 16 3/4S T W 1963 24: 24004 � 24002 24 123'W 23907 J 5/8" MPEI 1 1 /8" MPE 2006-E a, 2006-E !2� 23917 w� Approximate location of potholes, see sheet C-1 V w v uj 93'S N 1 1/8" MPE 2011-E 23921 24005 v v 2 3'N 5/8" PE 252'S 1993 173'N,24'E T 4" PVC Casingq 707017432-2003JT 23931 5/8" Mf 2002 24007 5/8" MPEI 2003 t -` 24009 ,b�; RECEIVED - 168'E 5/8" MPEI 766'E' 003 O C T 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 311/4"PEIP7' 76TH AVE W 18212 67S T 863404 32'E ,214 99 5 MPE 1Cn 99 18205 � W 199'7MPE a C e PE 199 1994 Approximate \O location of 72'`" M potholes, see T T sheet C-6 3o T 804'N 216 � 76�14 PEAVE W 5/8" PE / 1994 869S T 1 1/4" PE 1 1/4" MPE IP 1'N 32'N 9504156 18218 18223 76TH AVE W- ® 5/8" PE 1990 18125 1 1 /8" MPE 2011-E 18201 18211 W c\, �V 222'E E ® 2009MPE 18219 T��7 S CL 250'E 1 1/4" PE 251'E a 10 3'N S CL5/8" PE8301 1988 5/8" PE 1988 7524 751 5/8" PE 7525 1988 \ 5 2 18309 RECEIVED 7531 OCT 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT