ENG2021-0095 ROW PERMITRIGHT OF WAY EUC PERMIT
PERMITNUMBER,
City of Edmonds
_7 121 5th Ave N, Edmonds WA 98020 ENG2021
-0095
ii
www.cityofedmonds.gov
Description: PUD-REPLACE B.O. POLE PLI 9025 W/ CHANGE IN POLE LOCATION
ISSUED: 09/23/2021
Address: 19009 92ND AVE W EDMONDS WA 98020-2383
EXPIRES: 03/23/2022
Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434600003009
NAME TYPE NAME ADDRESS
PHONE
APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206
(425)670-3216
CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206
(425)670-3216
OWNER BARROW TODD 19009 92ND AVE W, EDMONDS WA 98020
FEE INFORMATION
DESCRIPTION AMOUNT
PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00
$0.00
RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00
$0.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
W4101" 09/23/2021
RELEASE15 BY DATE
Printed: Thursday, September 23, 2021 3:05:22 PM 1 of 2
-KRWOF WAY EUC PERMIT
City of • • •
www.cityofedmonds. ov/425.771.0220
CONDITIONS
CONDITION TYPE
Easement and/or permission from adjacent property owner is required prior to entry or work within
ADJACENT PROPERTY
an adjacent property.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
Alert affected residents and/or businesses prior to work start.
Verify clear bore crossings.
ENGINEERING OTHER
Restore landscape to like or better conditions.
Call for required inspections as noted.
ESC REQ
Maintain erosion and sedimentation control per City and SWMMW standard requirements.
Sound/Noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND OR NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites/activities must comply with the noise limits
of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
TRAFFIC CONTROL
Traffic Control per approved plan and MUTCD. All Flaggers shall be certified.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION MEN
RESULT
A-1 JOB START
X-2 ENGINEERING FINAL"
E-7 SEWER MAIN
Printed: Thursday, September 23, 2021 3:05:22 PM 2 of 2
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Scope: Replace bad order pole PLI 9025. (Note: Pole and transformer is only serving customer at "19009" 92nd Ave W). New pole will be installed
in place of the old pole at address "9138" 189th PL SW in the backyard. PUD crews will access the private driveway during fence removal, tree
trimmino and construction. Street traffic will not be impacted and flappers will still be available if needed.
Please include fence removal and restoration with hedge trimming work for permit use.
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
x
LF
SF
n/a
Alley 72 hours +
LF
x
LF
SF
8 hours
Parking 72 hours +
LF
Ix
I LF
SF
n/a
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications ❑ cable ® power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
X
No
2. 1 Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
X
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existingunderground common utilitysystem?
X
5.
Does the work involve proposed additions to an aboveground utility system? If es:
X
Are the additions for the purpose of serving new commercial development?
n/a
Are the additions for the purpose of serving a single-family residential subdivision?
n/a
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
If yes, answer the following questions related to project area, i.e. the actual area in which the
X
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes: Primary and Secondary overhead wires.
X
How many are existing? 1 1 1 How many are to be added? I none
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes: (1) 40' Primary Pole
X
How many poles are existing in the project area? 1
What is the height of the existing poles? 40'
How many poles are to be removed? 1
Are additional poles to be laced? no
How many? I n/a I What is the height of the additionalpoles? n/a
6c.
Are any poles to be modified/rebuilt/replaced? If yes: Replace
X
How many? 1 1 1 What is the height of the poles after? 1 40'
Describe the modification rebuild: Replace existing 40' pole & anchor with a 40' pole and new anchor
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE:
APPLICANT PRINTED NAME:
APPLICANT TITLE:
Ie 11wo
Richard Dumo
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
DATE: 8/12/2021
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM
$N-0 0 ISM COVNTv
PUBLIC UTILITY DISTRICT NO.1 OF SNOHOMISH COUNTY
LOCATION 19009 92ND AVE W, EDMONDS WA 98020 LYNNWOODAREA
POLE NO. PLI 9025 SW1/4S 18 T 27N R 3E DATE 8/9/2021 ORDER 100076722
REASON FOR WORK ENGINEER RDUMO OPERATION 30
REPLACE BAD ORDER DRAFTER RDUMO U.G. NO.
POLE PLI 9025 APPROVED SCALE NTS
`�{}s
& DATE PRINTED
DATE WORK COMPLETED
FOREMAN
FEES REQ'D El YES ■NO
RIMARY OVERHEAD
RESIDENTIAL
❑ OMMERCIAL
LEO N0.
SEC DARY OVERHEAD
CONTACT INFO:
19009 92ND AVE W
TODD & ROBERTA BARROW
(425) 218-7776
9138 189TH PL SW
ROBERT 'BOB' DIEGERT
(206) 390-1743
NESC VIOLATIONS
BASIC FEE E ■ NO ❑ YES (SEE NOTES)
@$ '=$ PERMITS (DATE GRANTED)
METER/ ONV. POLE S ❑ TREE TRIM
PRIMARY UNDERGROUND El STATE
❑ RESIDENT L ❑ COUNTY
❑ COMMERCI ■ CITY EDMONDS
LEU NO.
SECONDARY
'@$
$
UNDERGROUND AT
BAS FEE
E
q FT.@$
_$
STREET LIGHTING
CE FT.@$
_$
WORK IN RIGHT OF WAY
❑ PRIMARY
❑ SECONDARY
q FT.@$
$
MISCELLANEOUS FEES
VAULT
S_
PERMIT
S_
S_
S_
TOTAL DUE
3
DATE PAID
RECEIPT NO.
SERVICE ORDER NO.
FI;FNn:
BASIC FEE 3 ❑
EASEMENTS
=$ ■ REQUIRED ❑ NOT REQUIRED
DERGROUND
SIC FEE S
DATE RELEASED
FOREIGN CONTACTS
■ JPN#
❑ JOINT TRENCH ZIPLY & CATV
❑ JOINT BORE ZIPLY & CATV
1-1
POLE STENCILING
FROM TO
TAKE OFF POLE
PRE-CONST. REQUIRMENTS
❑ TREE TRIM ❑ PUD LOCATOR
❑ BACKHOE ■ FLAGGING
■ ONE CALL DATE
No.
STREET LIGHTING
❑ YES ■ NO
M&R AS -BUILT
GIS
GIS QC M&R
GIS Ph JOINT USE
LOCATION MAP PAGE 454-H3
O EXISTING POLE
X EXISTING POLE -TO BE REMOVED
• NEW POLE
NEW POLE TO REPLACE EXISTING POLE
DATE 8/9/2021
SUBSTATION MAPLEWOOD
CIRCUIT NO. 12-345 PHASE 3
RICHARD DUMO
ENGR'S TEL. #
425-783-5110
ENGR'S CELL #
425-346-8846
INSPECTION REQUIRE
VACTOR REQUIRED FOR
EXCAVATION FOR NEW
POLE DUE TO THE CLOSE
PROXCIMITY TO THE
SEWER MAIN
SL-117670-A 11 FU100 I 18919
242 282854
190TH ST SW
120029 M MPL
12
25-357478
197592
r-- _9
FU15
19005
rn
19015
1 AYn1 IT
CONSTRUCTION NOTES
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
BEFORE CONSTRUCTION:
THIS JOB INVOLVES DELICATELY INSTALLING A POLE BETWEEN FULLY GROWN
HEDGES BEHIND A FENCE. THREE FENCE PANELS WILL NEED TO BE CAREFULLY
REMOVED AND RE -INSTALLED BY THE ATTACHED 1818. PLEASE NOTIFY RICHARD
DUMO WHEN CONSTRUCTION DATE IS SET FOR PRE -CONSTRUCTION MEETING.
CUSTOMER ROBERT DIEGERT AT "9138" WANTS TO BE PRESENT DURING
CONSTRUCTION. CUSTOMERS AT "19005" & "19009" NEEDS TO BE NOTIFIED AS
WELL BEFORE CONSTRUCTION.
OWNER/CONTRACTOR IS RESPONSIBLE FOR
AO AT POLE Di 9025 EROSION CONTROL AND DRAINAGE
EXISTING 40' CLASS 2 POLE
INSTALL GROUND PLATE ON NEW 40' POLE (N0110)
SET 40' CLS 2 POLE IN PLACE OF EXISTING POLE (PW2040)
INSTALL PLATE ANCHOR W/ LEAD APPROX 12' EAST (A0203)
INSTALL 3/8 INCH PRIMARY DOWNGUY (GO113)
INSTALL 10 VERTICAL DEADEND ASSY (12V109)
SLEEVE #2 WIRE TO EXISTING PRI OH AND NEUT AS NEEDED
INSTALL 15KVA OH TRANSFORMER (BA21L)(12V601)
INSTALL 6A FUSE (E1006)
UTC#---------------- SER#----------------
SEC VOLT ----------------
REMOVE OLD 15KVA OH TRANSFORMER
UTC#---------------- SER#
----------------
HANG COMCAST SVC FROM J-HOOK 40" BELOW NEUT (R1112) L
HANG ZIPLY SVC FROM J-HOOK 46" BELLOW NEUT (R1112)
REMOVE GUYWIRE AND CUT ANCHOR 1' BELOW GROUND LEVEL
REMOVE AND HAUL AWAY OLD POLE
PERMANENT ATTACHEMENT TO THE NEW POLE WILL BE FINALIZED
BY OTHER UTILITIES
13
9138
0 9128 FU100
1-� 3
2 FU15
4377 1
242
N MPL
12
19009 NORTH
CKT
MPL 345
ENGINEERING DIVISION
APPROVED AS NOTED
%I/ Ulf✓.X,,,,,44z 09/21/2021
VV
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
RESUB
AUG 12 2021
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
G
0 9025
15-
SCHEMATIC
AFTER
KIWI