APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
PLEASE KEEP WITH THE PLANS
ISMOKE ALARMS/DETECTORS SHALL BE
.INSTALLED IN ALL SLEEPING ROOMS, IN THE AREA
(OUTSIDE THE SLEEPING ROOM AND IN OTHER
.LOCATIONS PER IRC R314 & NFPA 72. POWER
(SOURCE AND INTERCONNECTION PER CODE.
■ALARMS MUST BE A MINIMUM OF 36 INCHES AWAY
(FROM BATHROOM DOORS, HEATING OR COOLING
;REGISTERS, AND CEILING FANS. ■
!Whole House Ventilation System Controls:
■All ventilation system controls shall be readily
!accessible. Intermittently operated systems shall
■have a manual control, as well as an automatic ■
(control, such as a clock timer. The automatic !
■control timer shall be set to operate the whole ■
!house fan system for at least 8 hours a day. IRC !
■ M 1507.3.2 ■
CARBON MONOXIDE ALARMS
■
• REQUIRED LOCATIONS PER IRC R315.3: APPROVED
(CARBON MONOXIDE ALARMS SHALL BE INSTALLED '
■OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE !
IMMEDIATE VICINITY OF THE BEDROOMS AND ON ■
■ EACH LEVEL OF THE DWELLING IN ACCORDANCE
(WITH THE MANUFACTURER'S RECOMMENDATIONS. ■
• WHERE A BEDROOM OR ITS ATTACHED BATHROOM
CONTAINS A FUEL -BURNING APPLIANCE, A CARBON
MONOXIDE ALARM MUST BE INSTALLED IN THE •
'BEDROOM.
EXISTING DWELLINGS PER IRC R315.2.2 SHALL BE '
■ EQUIPPED WITH CARBON MONOXIDE ALARMS IN
(ACCORDANCE WITH THE INFORMATION ABOVE ■
■ (SOME EXCEPTIONS MAY APPLY). AN INSPECTION !
!WILL OCCUR WHEN ALTERATIONS, REPAIRS OR •
•ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN
!ONE OR MORE SLEEPING ROOMS ARE ADDED OR
CREATED. BATTERY POWERED ALARMS ARE •
' PERMITTED IN EXISTING DWELLINGS. !
!COMBINATION ALARMS PER IRC R315.4 '
■COMBINATION SMOKE AND CARBON MONOXIDE !
!ALARMS MAY BE USED IN PLACE OF CARBON ■
■ MONOXIDE ALARMS.
POWER SOURCE PER IRC R315.5 CARBON MONOXIDE ! •
ALARMS SHALL RECEIVE PRIMARY POWER FROM THE !
!•BUILDING WIRING AND, WHEN POWER IS
INTERRUPTED, SHALL RECEIVE POWER FROM A •
'BATTER.
III ■ - ■ Y- ■ - ■ - ■ - ■ - ■ - ■ - ■ - ■ -
r ■ — ■ — ■ — ■ — ■ — ■ — ■ — ■ — ■ — ■ — a
KITCHEN RANGE HOODS ARE REQUIRED IN I
.ALL DOMESTIC KITCHENS. HOODS CAPABLE
OF EXHAUSTING MORE THAN 400 CFM I
REQUIRE MAKE UP AIR. IRC M1503 ■
NOTE: This Stamp page must remain with the city approved plans at all times. Failure to have this
Stamp page with the City approved plans could result in delay of the inspections including the FINAL
inspection. If lost please contact the city as soon as possible to find a solution. Thank You.