Loading...
APPROVED BLD-BLD2020-1395+Architectural_Plan+12.17.2020_6.37.08_PM+1954041City Of Edmonds Building Department Work REMODEL Address 7726 202ND PL SW, Owner SMITH Approved Date 1 /15/2021 Building Official lcew� &L00N ��16( Permit Number BLD2020-1395 APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES TYPICAL NEW ROOF CONSTRUCTIO VENTED BLOC MATCH PLATE HEIGHT NSULATED HE TYPICAL EXTE WALL CONSTI EXISTING GOP FOUNDATION MATCH FLOG LINE TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION COMPONENT CRITERIAa A r b arrier and thermal barr�r A coati nwin air barrier shallb It installed in the building envelope. ]exterior thermal envebpIt contains a coriti r-ious air barrier. Brealm or j oints in the air barrier shallbe sealed. Ar- ermeabk insulhtion shallnot be used as a sealing material Caves insulation installation A 11cavities in the thermal envelope shallbe filled with msuhtion. The denser ofthe insulation shall beat the manuficturers' product recommendation and said densiv shallbe maintained for allvohmne ofeach cavity, Batt type insulation %gill show no voids or gaps and maintain an even density fDr the entre cavity. Batt insulation shallbe installed is the recommended cavity depth. 'k here an obsti-uction in the cavity due to services. blacking, brat ing or other obstr-wtion exists. the batt product willbe cut to fit the remaining depth ofthe cavity. Where -re re the batt is cut around obstructions. loose fill -any Insulation shallbe placed to fill surface or concealed voids_. and at the manufacturers' specified density. Where faced Batt is used. the installation tabs must be stapled to the face ofthe stead. There shall be no compression to the bast at the edges ofthe cavity due to inset stapling installation tabs. Insulation that upon installation readA, conforms to aynihbk space shallbe installed the entire cavity and within the manufacturers' density recommendaticn. CeiliFiglattic The air barrier m any dropped ceiling/soffit shall be aligned with the Insulation and my gaps in the air barrier sealed. Acc ess openings. drop down star or knee wall doors to unconditioned attic spaces shallbe sealed. Batt insulation installed in attic roof assemblies may be compressed at exterior Nall lases to allow fiar required attic - ventRatiorn. Walk Corners and headers shallbe msLdated and the junction ofthe fbundatisn and sillplate shallbe sealed, The junction ofthe top plate and top ofexteriar .�,-alls shallbe sealed. Exterior thermal envelope insulation for framed walls shall be installed In substantial contact and conti mows errt ,Aith the air barrier. Knee walls shallbe sealed. Windows. skvlights and doors The spacebetu eeinsx-indow/door jambs and framingand skvliahts and framing shallbe sealed. Rim joists Riin joists shall be insulated and=' Jude the air barrier. Floors (inc]udiag above -garage and Insulation shall be installed to maintain permanent contact ��Ythunderside ofsubfloor cantilevered floors) decking. The air barrir shallbe installed at any exposed edge ofinsulation Crawlspace walk II provided m lieu offloor insulation, insulation shall be permanently attached to the crawlspace walk. E-posed earth inunvented crauxl spaces shallbe covered with a Class I -vapor retarder with overlappingjoints taped. Shafts. penetrations Duct shafts. utility penetrations. and fhie shafts opening to exterior or unconditioned space shallbe sealed. Narrow cavities Batts in narrow cavities shall be cut to fit and installed to the correct density without any voids or gaps or compression, Narrow cavities shallbe filkd by insulation that on Installation readily conforms to the available cavity space. Garage separation Ar sealing shallbe provided between the garage and conditioned spaces, Recessed lighting Recessed light fintures Installed in the building thermal envelope shall be air tight. Ic rated, and sealed to the drvxa1L Phunbing and wiring Batt insulation shallb It cut neatly to fit around wiring and phainbing in exteriar walls. There shallbe no voids or gaps or compression •here cut to fit. Insulation that on installation readily confirms to a-vailable space shall extend behind piping andwiring. Shower/tub an exterior uall F--tenor walls adj acmt to showers and tubs shall be insulated and the air barrier installed s ep aratiM them from the showers and tubs. ElectricaFphone box on exterior walls The air barrier shallbe installed behind eketricalor corn mmicationboxes or air sealed boxes shallbe installed. HVAC register boots HVAC register boats that penetrate building thermal envelope shall be sealed to the subfloor or u-all. Fireplace An air barrier shallbe installed on fireplace walls. Fireplaces shallhave gasl£eted doors, a_ In addition inspecticai of log mralls shall be in accordance with the provisions of ICC -400_ RE-24 TYPICAL NEW ROOF CONSTRUCT ION 6IMP50N HI CLIP @ TRUSS TO PLATE CONNECTION TYP. NEW PLATE LINE EXIST. PLATE LINE TYPICAL EXTERIOR WALL CONSTRUCTION TYPICAL UPPER FLOOR CONSTRUCTION (EXISTING TO REMAIN) EXISTING UPPER FLOOR LINE TYPICAL EXTERIOR WALL CONSTRUCTION (EXISTING WALL FURRED TO RIO RIGID INSULATION W/ 1 /2" ALL WEATHER PROTECTION f5OARD. METAL FLASHING @ EXPOSER EDGE A WALL �5EGT I ON @ K 1 T-6HEN 2012 Washington State Energy Cade PROVIDE 6IMP60N LTP4 CLIP & 2-4" O.G. @ TOP PLATE TO f5OTTOM PLATE CNNECT ION EXISTING CONCRETE FOUNDATION EXISTING CONCRETE SLAB WALL �5EGT I ON @ LIVING ENERGY NOTES I. PROJECT TO COMPLY WITH PRESCRIPTIVE REQUIREMENTS OF THE 2015 WASHINGTON STATE ENERGY GORE RESIDENTIAL PROVISIONS, CLIMATE ZONE 46. 2. FENESTRATION MAXIMUM U-VALUE 3. CEILINGS SHALL t�)E INSULATED TO MINIMUM R49, SINGLE RAFTER OR JOIST VAULTED CEILINGS R35. PROVIDE EAVE f5AFFLE6 N VENTED ATTIC PER SECTION R402.2.3. 4. WALLS SHALL f5E INSULATED TO MINIMUM R21. 5. HEADERS SHALL f5E INSULATED TO MINIMUM R I O. G. BUILDING THERMAL ENVELOPE INSTALLATION PER TAf5LE R40Z.4.1.1 9. RECESSED LUMINAIRES INSTALLER IN THE f5UILDING ENVELOPE SHALL t5E IC RATED AND HAVE AN AIR LEAKAGE RATE AS SPECIFIER PER SECTION R402 4.4. 10. PROVIDE MECHAN I GAL VENTILATION PER SECTION R403.5. PROVIDE SOURCE SPECIFIC VENTILATION IN f5ATHROOM & LAUNDRY ROOM OF 50 GFM INTERMITTENT OR 20 GFM CONTINUOUS, MINIMUM EFFICACY OF 2.5 GFM/WATT. PROVIDE SOURCE SPECIFIC VENTILATION IN KITCHEN MINIMUM 100 GFM INTERMITTENT OR 25 GFM CONTINUOUS MIN. EFFICIACY OF 2.5 GFM/WATT. 12. ALL EXTERIOR BOORS SHALL f�E WEATHER -STRIPPER. 13. ACCESS BOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL f5E WEATHERSTRIPPE P AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON SURROUNDING SURFACES PER SECT ION R402.2 4. 15. MECHAN IGAL SYSTEM PER WSEG SECTION R403. PROVIDE WHOLE HOUSE MECHANICAL VENTILATION PER SECTION MI507 OF THE IRG. VENTILATION SYSTEM SHALL t�)E CAPABLE OF PROVIDING THE VOLUME OF OUTDOOR AIR SPECIFIED IN TALE M 15052. INTERMITTNTLY OPERATED WHOLE HOUSE SYSTEM SHALL HAVE THE CAPAN L I TY FOR CONTINUOUS OPERATION & SHALL HAVE A MANUAL CONTROL & AN AUTOMATIC, CONTROL & SHALL f5E SIZED ACCORDINGLY, PER I RC CHAPTER 15 M I5073,M I505.2 & M 1508.3. IC,. PROVIDE AT LEAST ONE PROGRAMMAf5LE THERMOSTAT FOR EACH SEPARATE HEATING AND GOO-ING SYSTEM PER SECTION R�03.I.I. IT MECHANICAL DUCT INSULATION PER SECTION R40'5.5 AND PIPING INSULATION PER R403)A 15. ELECTRICAL POWER AND LIGHTING PER SECTION R404. 0. AIR LEAKAGE TESTING PER WSEG SECTION R4024. (TESTING NOT REQUIRED PER 4024.1.2 EXCEPTION ##I, ADDITIONS LESS THAN 500 SF). REVIEW DUCT TESTING REQUIREMENTS WITH f5UILDING 20. ADDITIONAL ENERGY EFFICIENCY REQUIREMENT: ADDITIONS LEss THAN 500 SF, 05 POINTS REQUIRED, 1. COMPLIANCE OPTION 3A- HIGH EFFICIENCY HVAC EQUIPMENT, (1.0 POINT): GAS FIRED FURNACE WITH MINIMUM AFUE OF 94%. RISERS: MAXIMUM RISER HEIGHT SHALL �E NO GREATER THAN 7-3/4 VARIANCE f5ETWEEN RISER HEIGHT SHALL f�E NO GREATER THAN 3/5" WITHIN A FLIGHT OF STAIRS. R 15ER5 SHALL f�)E VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD Af5OVE AT AN ANGLE NO MORE THAN 30 DEGREES FROM VERTICAL. RISERS SHALL f�E SOLID OR LESS THAN 4". TREADS: MINIMUM TREAD DEPTH SHALL f�E 10". VARIANCE f5ETWEEN TREAD DEPTH SHALL NOT EXCEED 3/5" WITHIN A FLIGHT OF STAIRS. NOSING: THE RADIUS OF THE NOSING SHALL NOT f�E GREATER THAN 9/I6". NOSING PROJECTION SHALL NOT f5E LESS THAN 3/4" AND NO MORE THAN 1-1/4" @ STAIRWAYS WITH SOLID RISERS. NOSING PROJECTION NOT REQUIRED WHEN THE TREAD DEPTH IS NOT LESS THAN 11". STAIR WALKING SURFACE: WALKING SURFACE SHALL t�)E SLOPED NO GREATER THAN 2%. HANDRAILS: HANDRAILS SHALL t5E PROVIDED ON NOT LESS THAN ONE SIDE OF A CONTINUOUS RUN OF FOUR OR MORE RISERS. HANDRAILS SHALL f�E NOT LESS THAN 34" AND NOT MORE THAN 35" ABOVE THE TREAD NOSING. HANDRAILS SHALL f�)E CONTINUOUS THE FULL FLIGHT OF STAIRS. HANDRAILS SHALL f5E RETURNED OR TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS SHALL f5E SPACED 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. HANDRAILS SHALL f5E SIZED NO LESS THAN 1-I/4" AND NO GREATER THAN 2". ILLUMINATION: STAIRWAYS SHALL f5E PROVIDED WITH ILLUMINATION PER IRO SECTION R303.7 GUARD NOTES: GUARDS: GUARDS SHALL f5E PROVIDED @ WALKING SURFACES 30" Af5OVE ADJACENT GRADE. GUARDS SHALL f5E MINIMUM 3�O" IN HEIGHT. GUARDS ON THE OPEN SIDES OF STAIRS SHALL f�)E NOT LESS THAN 34" IN HEIGHT. GUARDS SHALL NOT HAVE OPENINGS 4" OR GREATER. GUARDS ALONG THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS 4-3/5" OR GREATER. PROJECT NOTES PROJECT NAME: PROJECT ADDRESS= PROJECT DESCRIPTION: PROJECT OWNER: ARCHITECT: SURVEYOR: PARCEL NUMf5ER: LEGAL DESCRIPTION: ZONING: LOT SIZE= LOT COVERAGE: CONSTRUCTION TYPE: OCCUPANCY GROUP: �)U I LP I N G AREA FIRST FLOOR: SMITH RESIDENCE REMODEL 77U 2- 2ND PLACE SW EDMONDS WA �5502(a REMODEL EXISTING SINGLE FAMILY RESIDENCE MARK & DE��IE SMITH 7726 2- 2ND PLACE SW EDMONDS WA 95OU 253.775.3(79 MARK PARKER ARCHITECTS PL-C 2-52-5 ELL I6 ST. f5ELLINGHAM, WA 435225 ZO�O.5q7.7�33 f5f5A LAND SURVEYING 12014 SE 157TH PL. RENTON WA �55055 ZO(O.40(a,1257 00512700001200 LOT 12 OF MEADO-PARK, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 117, RECORDS OF 6NOHOM16H COUNTY AUDITOR. 50' X �3' = 7440 SF ALLOWAt�-E: 7440 X 35%= U04 SF ACTUAL: 13�5 SF V-f� R3-6INGLE FAMILY RESIDENTIAL EXISTING................................................................................................1251 SF ADDITION.....................................................................................................2 SF TOTALFIRST FLOOR..............................................................SF SECONDFLOOR: EX 1 ST I NG.................................................................................................535 SF TOTAL:...................................................................................................................................................152 5 SF GENERAL NOTES I. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL RESIDENTIAL GORE (IRG) 2015 ADDITION, UNIFORM PLUMING GORE (UPC) 2-015 ADDITION, INTERNATIONAL FIRE GORE (IFC) 2015 ADDITION, NATIONAL ELECTRIC GORE (NEC) 2.015 ADDITION AND STATE AMENDMENTS. 2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS, MEMf5ER SIZES AND CONDITIONS PRIOR TO CONSTRUCTION. 3. DO NOT SCALE DRAWINGS. 4. ALL DIMENSIONS TO FACE OF STUD OR FACE OF CONCRETE UNLESS NOTED OTHERWISE. 5. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AND It)E RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES AND SEQUENCES REQUIRE FOR COMPLETION OF THE WORK. (a. DURING CONSTRUCTION PROVIDE & MAINTAIN FIRE EXTINGUISHERS AS REQUIRED PER LOCAL FORE DEPARTMENT. 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED f5UT ARE OF SIMILAR CHARACTER TO DETAIL SHOWN, S 1 M I LAR DETAIL OF CONSTRUCTION SHALL f5E USED, SUBJECT TO REVIEW AND APPROVAL f�)Y THE ARCHITECT. 5. MAINTAIN (a" MINIMUM SEPARATION f5ETWEEN FINISHED GRADE & UNTREATED MATERIALS. 43. FINISH GRADE SHALL SLOPE AWAY FROM THE f5UILDING TOWARD DRAINAGE FAG I L I T I ES. SLOPE ALL DECKS WALKS AND PATIOS, 4'" PER FOOT AWAY FROM f5UILDING. 10. ALL LUMBER MUST SEAR A GRADING STAMP, II, ALL WOOD IN CONTACT WITH EARTH OR CONCRETE SHALL f�E PRESSURE TREATED. ALL EXPOSED METAL SHALL t�)E PAINTED, 12F�A ALARMS SHALL COMPLY W/NFPA 72 & LISTED W/UL21AT I ON ALARMS SHALL �E LISTED W/UL ZI7 & UL203q�. SHALL �E INTERCONNECTED. ALARMS SHALL �E RED W/15ATTERY BACKUP. J W Q O � z W O ce W V) z V w z Q = W (n Q J � >Q V) 0 w z moo = N z O �p N C) M0 00 Vi II w M V J J a U) V W Ln = N V 00 M a C >Q W rn M oG(nQa*) a�=r"I a J (DIIIIIII � w z � ,-I J aNJ`° 00 N w m O N CITY APPROVAL STAMP RECEIVED Dec 22 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12/11/2020 A 1 DOOR SCHEDULE- ALL DOORS NEW NO. SIZE NOTES x ('-5'" TEMPERED GLAZING X 3 2,-4„ X 4 2'_0„ X 5 (4)1'-41) X 2'-0'" X (v,_5„ 7 2'-5" X 15 3'—O" X ('-5" TEMPERED GLAZING 5-0" X (a"-5'" TEMPERED OLAZING 10 (4)1,_(„ X X X 13 (4)1,_(a„ X 14 2)—O„ X (,-5„ EXISTING 4 1 -111 NEW MANUFAC ED COMMON TRUSS @ 2-4" I„ 1° 0.�,. 0 TOILET DRAIN j� TRAVELS TO + EXTERIOR WALL, THEN TRENOH �p TO LINE RUNNING DOWN WEST N PROPERTY LINE w tEDROOM o III II I I I I 1� —1 1L F 0 12 II I II I II 13 I f5EDROOM II II I II II go �m� 0 moon m�m�m moon m�m� 0 moon 0 �m� 0 moon 0 �m�m moon m�m�m moon m�m�m moon m�m�m moon m�m� 0 moon 0 �m� 0 moon 0 �mmm% SHOP DRAWINGS FOR PRE-ENGINEERED FLOOR OR ROOF TRUSSES MUST BE ONSITE AT TIME OF FRAMING INSPECTION AND HAVE AN ORIGINAL WASHINGTON SEAL & SIGNATURE OF THE DESIGNER. PROCEEDING WITH FRAMING WITHOUT APPROVED DETAILS AND PLANS IS I DONE SO AT THE RISK OF THE CONTRACTOR/APPLICANT. NORTM �5EGONP ff LOOR PLAN 1 /4)1=1,_0„ TYPICAL CONSTRUCTION ASSEMBLIES TYPICAL ROOF ASSEMtLY • NEW COMP, 3—TAB SHINGLE • NEW ROOFING PAPER • NEW 1/2" ROOF SHEATHING • NEW MANUFACTURED TRUSSES @ 2-4" O.O. • NEW R*9 f5ATT INSULATION, (R35 @ VAULTED CEILING) MAINTAIN MIN. I" FREE AIR SPADE • NEW 8' GYPSUM f5OARD TYPICAL EXTERIOR WALL ASSEMBLY • NEW WOOD SIDING PER ELEVATIONS • NEW 15UILPINO PAPER • EX16TINO 1/2" WALL SHEATHINO • NEW ZX� @ Iq" O.C. WOOD FRAMING OR NEW 2X FURRING ON EX16TINO STUDS • NEW R21 GATT INSULATION • NEW 2„ OYPSUM f5OARD TYP I CAL INTERIOR WALL ASSEM f5LY • NEW 2" GYPSUM i5OARD 15OTH SIDES • NEW 2X4 @ I(" WOOD FRAMINO (2X(o @ 1(" 0.0 .WHERE NOTED) • NEW SOUND INSULATION @ MASTER F5ATHROOM/MA6TER SUITE LINE OF OVERf1AN6 —(a" TYP. NEW FACTORY f5UILT OAS FIREPLACE FACTORY -BUILT FIREPLACES ,SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ■ACCORDANCE WITH THE (CONDITIONS OF THE LISTING. ■DECORATIVE SHROUDS SHALL BE ■ LISTED AND LABELED FOR USE WITH THE SPECIFIC ■ (FACTORY -BUILT CHIMNEY SYSTEM i AND INSTALLED IN ACCORDANCE (WITH THE MANUFACTURER'S ■ I� INSTALLATION INSTRUCTIONS. IRC SYMBOL LEOEND NEW WOOD FRAMED WALL —EX16TINO WALL TO REMAIN -EXISTING WALL REMOVED O SMOKE DETECTOR 6MOKE/6ARf5ON DETECTOR EXHAUST FAN FACTORY QUILT CHIMNEY AND FIREPLACE PER IRC SECTION R 1 OO4,R 1005, & R 1OO(a. FACTORY QUILT CHIMNEY & FIREPLACE SHALL t5E UL APPROVED & INSTALLED PER MANUFACTURER'S RE UIREMENTS, 101 TYPICAL MAIN FLOOR ASSEMBLY • NEW FINISHED FLOORING • NEW UNDERLAYMENT • EX16TINO FLOOR SHEATHING • EXISTING WOOD FRAMING • NEW R35 t5ATT INSULATION • NEW ( MIL. VAPOR 15ARRIER TYPICAL UPPER FLOOR ASSEMBLY • NEW FINISHED FLOORING • NEW UNDERLAYMENT • EX16TINO FLOOR SHEATHINO • EXISTING WOOD FRAMING • NEW a " GYPSUM BOARD ......................................................... ! MAKE-UP AIR ' ■ THE LOCATION OF THE DRYER IN AN ENCLOSE SPACE COMBINED WITH THE EXHAUST FAN WILL REQUIRE EXIST. WINDOW : MAKE UP AIR TO ASSURE THE PROPER OPERATI : : OF THE DRYER. PER IRC 2015 G2407.4 ■ OPENING..................................... ................- EXIST. WINDOW OPENINO W EXISTING 2X5 FLOOR JOIST Af5OVE �� __r - ':� 0 00 k�ol' � 0 5 � H.W. FURN F LIVING ROOM II T X wl I 01 I Q� I, EX16TINO 2X5 x wl FLOOR JOIST w �1 I Af5OVE II II II dom 0 Moon In moon 0 moon 0 Moon In moon 0 moon 0 Moon In moon 0 moon 0 Moon In moon 0 moon 0 �a I PROVIDE LANDINGS AT EXTERIOR DOORS WITH A I j. MINIMUM SIZE OF 36" IN THE DIRECTION OF TRAVEL AND ■ NOT LESS THAN THE WIDTH OF THE DOOR PER IRC R311.3I EXIST. WINDOW OPEN INO 4NE II�DN.S) II UP II BEDROOM v N Q� DINING K s z S II IL �< O O CEILING o L Lu RIDOE F_ w -- --- IF II I REF. � WALK— C OL05E_ I I � I LOW WALL N KITOHEN NEW z EXIST. WINDO OP NINO OCD DW. w — — — EXISTING KITCHEN SUMP —OUT REMOVED +/-15'-4" XISTING EX16TINO I. ALL EX16TINO EXTERIOR WALLS FURRED OUT TO • �' �' • �' �' ■ �' �' • 2. ALL EXISTING NON—f5EARING INTERIOR WALLS REMOVED KITCHEN RANGE HOODS ARE REQUIRED IN 3ALL DOMESTIC KITCHENS. HOODS CAPABLE. . NEW INTERIOR WALLS SHALL �E 2X� @ I�"" O.G. . I OF EXHAUSTING MORE THAN 400 CFM 4. NEW EXTERIOR WALLS SHALL 15E ZX(a @ I(aO.C. IN REQUIRE MAKE UP AIR. IRC M1503 • 5. EXISTING DOORS AND WINDOWS REMOVED AND REPLACED W/NEW. M EMO (a. NEW HEADERS SHALL F5E (2)2X5 UNLESS NOTED OTHERWISE 7, ROOF SHEATHING SHALL f�E 1/2-" CDX PLYWOOD PANELS (EXPOSURE I, SPAN RATING 2411(a). NAIL AT ALL FRAMED PANEL EDOES AND OVER ALL WALLS SHOWN ON PLAN WITH 5d (" O.G. AND TO ALL INTERMEDIATE FRAMINO @ 12" O.G. 5. ROOF FRAMING SHALL f�)E PREFABRICATED CONNECTOR PLATE ROOF TRUSSES @ 2-4" O.G. NORTH 1= I RAT ff LOOR PLAN 1/4„=1,_0„ i b LINE OF OVERHANO TYP. J W 0 O 2 z W O tie I— W v) z V w z Q = W (n o J >Q 0 wzUi � � = O N z O � F■I �p � � N N O Vi w O) V J J IL U) l000 W loloo Ln m N = N V 00 O a >Q W r,r) v) M oG V) < � w z ,-I J Ln aNJ`° 00 N w CO O N CITY APPROVAL STAMP RECEIVED Dec 222020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12/11/2020 A2 MAX. ALLOWABLE HT. 439.,37' _INE Off VAULTED CEILING P KITCHEN/PINING XISTING WINDOW OPENING _OWER SILL AS REQUIREP v1AXIMUM SILL HEIGHT 44" �f!5OVE FIN IsHEP FLOOR TO 50TTOM OF W I NPOW 2PEN INC. ff-A�5T ff-LEVAT ION MAX. ALLOWABLE HT: l-TING SEGONP 2RY LINE +7'-(" STING PLATE E WD5T ELEVAT ION /4„= I,-0„ NORTH ELEVATION �5OUT1 i ELEVAT ION I/4„=I,_0„ SEGONP Y PLATE NG SEGONP Y LINE +-7'—(o" NG PLATE -E 0 J W 0 0 2 z W O tie � W V) z V w z Q = W (n Q J Q 0 W z Uj 0 = O N z O F-I 'o O 2: N N O Vi w O) V J J a U) V W H Ln = N V 00 oc m Q Q ce W v) M (n Q O� a�=� a J (D � w z ce Ln Q N J O 00 N w m O N x x CITY APPROVAL STAMP RECEIVED Dec 222020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 12/11/2020 A3