Loading...
APPROVED ENG BLD PLN - BLD2021-0113+Architectural_Plan+1.27.2021_12.21.56_PM+2013447PROJECT DATA I OWNER GUILLERMO & JOLEE CANO 20030 88TH AVE W EDMONDS, WA 98026 ROOF OVERHANG 12" CO PQ,O � o0 I _O r 4 ° (E) DRIVEWAY w 1120 SF - d ° 25'-0" rn^nrr°vAmr-% c,rrn Anv d ° - ° ° ° ° (E) DRIVEWAY `88TH AVE W ° (PRIVATE EASEMENT) a ° ° 4° ° �SOUTH P.L. 160'-0" (E) WALKWAY (E) FENCE � I I � I I 1 � SITE PLAN 1" = 10'-0" GENERAL NOTES THESE DRAWINGS ARE THE PROPERTY OF PACIFIC LIVING CONSTRUCTION LLC. 1. CODE - CONSTRUCTION TO CONFORM TO THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), WASHINGTON STATE LAWS AND REGULATIONS, CURRENT WASHINGTON STATE RESIDENTIAL ENERGY CODE AND VARIOUS CODES IMPOSED BY LOCAL AUTHORITIES. - A COPY OF THE APPROVED PERMIT PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION 2. SOILS - FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1,500 PSF OR PER GEOTECHNICAL REPORT. ALL FOOTINGS SHALL BE CAST ON UNDISTURBED FIRM NATURAL SOIL OR COMPACTED SOIL OF 1,500 PSF BEARING CAPACITY AT LEAST V-6" BELOW LOWEST ADJACENT GRADE, AND FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL BE FREE OF LOOSE SOILS, DEBRIS, AND FREE WATER AT ALL TIMES. ALL EXCAVATION AND FILL SHALL BE STORED AND PROTECTED SUCH AS TO PREVENT RUNOFF OF MATERIAL TO ADJACENT PROPERTIES. 3. STAIRS - MINIMUM HEADROOM 6'-8"; MINIMUM TREAD 10"; MAXIMUM RISER 7 3/4" - HANDRAIL: REQUIRED AT ALL STAIRS WITH MORE THAN 4 RISERS PER IRC 311.7.8. MINIMUM 34" AND MAXIMUM 38" ABOVE TREAD NOSING. OPEN SIDES OF STAIRS MORE THAN 30" ABOVE ADJACENT FLOOR SHALL HAVE HANDRAILS AND GUARDRAILS. HANDRAIL TO BE 1 1/4"-2" CROSS SECTIONAL DIMENSION AND 1 1/2" AWAY FROM WALL. - GUARDRAIL: SHALL BE MIN 36" IN HEIGHT WHERE ADJACENT SURFACE GRADE IS 30" OR MORE BELOW. RAILINGS SHALL BE SPACED TO NOT ALLOW THE PASSAGE OF A 4" SPHERE PER IRC 312.1. City Of Edmonds Building Department Work Deck Address 20030 88th AVE W Owner CANO Approved Date 2-4-2021 Building Official Eri,� Cu.rt�r Permit Number. BLD2021-0113 -------------------------- pAspinwail Community Buliding a Maplewood Edmonds Seventh-uay'j r Presbyterian Church Adventist Churchly �k P Brady & Company, CPAs Maplewood Rock 0 o 4u�et & Gem Club az� °bth St SW W �, a Vievrhad W&r 19£ith 57 51Y iq slerrn Wq o' Emerald Hills Q Maplewood Park r9�n sz sw � D 2otnn S<SW VW. Way s a o cPsna�a� DUE PI SW s 292nd PI S% < p _ Sler[a ;• � SW VICINITY MAP NOT TO SCALE Maplewood Parent Cooperative 2a2nd Sr SW f 2134111 St SW i9sth PI SW f n Pine Ridge Park ENGINEERING DIVISION APPROVED AS NOTED MY Wat"u 02/09/2021 VV DESIGNER SANDRA PIEDRAHITA PACIFIC LIVING CONSTRUCTION LLC PO BOX 15841 SEATTLE, WA 98115 206.678.5478 CONSTRUCTION DATA SCOPE OF WORK ATTACHED DECK AND STAIRS LOT AREA: 12,597 SF EXISTING RESIDENCE: 2065 SF EXISTING DECK TO BE DEMO'D (1150 SF) PROPOSED DECK 848 SF PROPOSED STAIRS ABOVE 36" 59 SF LOT COVERAGE: 2,972 SF ALLOWED: 12,597 SF x 35% = 4,409.... OK PROPERTY DATA PROJECT ADDRESS 20030 88TH AVE W EDMONDS, WA 98026 PARCEL # 00506700003407 ZONING DESIGNATION RS-12 HEIGHT LIMIT 2511 SETBACKS FRONT: 25' SIDE:10' REAR: 25' LOT AREA 12,597 SF LEGAL DESCRIPTION MAPLEWOOD HILLS BLK 000 D-07 - TH PTN OF TR 34 DAF - BEG ON S LN OF SD TR AAP 185.98FT W OF SE COR THOF TH N00*06 OOE 53FT TH N26*14 54W 31.66FT TO S LN OF N 85.34FT OF E1/2 OF SD TR TH N89*25 OOW ONSD LN 145.98FT TO W LN OF E1/2 OF SD TR 34 TH S00*06 OOW 81 FT TO S LN OF SD TR TH S89*24 25E 160FT TO POB TGW 1/4 INT AS TENTANTS IN COMMON FOR TENNIS COURT ON FDT TH PTN OF LOTS 34 & 35 DAF COM ON SLN OF SD LOT 34 AAP 185.98FT W OF SE COR THOF TH N00*06 OOE 53FT TH N26*14 54W 31.66FT TO SE COR OF W 145.98FT OF E1/2 OF N 85.34FT OF SD LOT 34 TH N00*06 OOE 6.74FT TO POB TH S89*25 OOE 64FT THN00*06 OOE 40FT TO S LN OF N 38.6FT OF SD LOT 34 TH N89*25 OOW ON SD S LN TO SW COR OF E 150FT OF N 35.6FT OF SD LOT 34 TH N00*06 OOE ON W LN OF E 150FT OF LOTS 34 & 35 TO S LN OF N 105FT OF SD LOT 35TH N89*25 OOW ON SD S LN TO W LN OF E 20OFT OF SD LOT TH S00*06 OOW ON SD W LN TO N LN OF SD LOT 34 SD PT BEING NE COR OF W 145.98FT OF E1/2 OF N 85.34FT OF SD LOT 34 TH S00*06 OOW ON E LN OF SD W145.98FT DIST OF 78.60FT M/L TO POB AKA LOT 3 CITY OF ED SP S-5-75 REC AFN 239079 SHEET INDEX AO.1 SITE PLAN A1.1 MAIN FLOOR PLAN A1.2 LOWER FLOOR PLAN A1.3 ELEVATIONS, SECTIONS APPROVED BY PLANNING ai Vo Feb 10 2021 OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE Project Title: CANO RESIDENCE 20030 88TH AVE W EDMONDS, WA 98026 Project No.: 2020022 Drawn By: SP Issue PERMIT Date: 12.14.20 Scale: 1 " = 10'-0" Sheet Size: 24" x 36" Title Sheet No.: SITE PLAN A0.1 7'-0" 15'-0" 10'-01, 0 1 (E COLUMN T T u / 00 O X 0 Z Cn _ (E) FIXED WINDOWS EXISTING RESIDENCE 7 14" ABOVE DECK SURFACE 20030 88TH AVE W c�v SAFETY GLAZING EDMONDS, WA 98026 (E) EXTERIOR LIGHT SOURCE D w (E) 72" X 80" (E) 72" X 80" SLIDING DOOR SLIDING DOOR DN DECK 5/4X6 COMPOSITE DECKING Ir O 00o X 0 0 1 Z_ ^ WJ_ O T J Cn _MI `o L 3'-6" 3'-611 71_011 201-011 RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT MAIN FLOOR PLAN /4"= 1 'D�i-0"" PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: CANO RESIDENCE 20030 88TH AVE W EDMONDS, WA 98026 Project No.: 2020022 Drawn By: SP Issue PERMIT Date: 12.14.20 Scale: 1 /411 = 1'-011 Sheet Size: 24" x 36" Title MAIN FLOOR PLAN Sheet No.: A1.1 / 1-211 1 511 (E) CONCRETE LANDING (E COLUMN T T _T1 VJ 71-011 71.3)/411 71_3Y411 I II FEEEEED I II I II T o -1 r I EXISTING RESIDENCE 20030 88TH AVE W EDMONDS, WA 98026 o r co r; I— — — — — DN — (E) CONCRETE LANDING T co O T r_ 0 1 co 71_011 31_011 71_011 71_011 31_0" RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LOWER FLOOR PLAN 1 1 /4" = 1 '-0" PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: CANO RESIDENCE 20030 88TH AVE W EDMONDS, WA 98026 Project No.: 2020022 Drawn By: SP Issue PERMIT Date: 12.14.20 Scale: 1 /411 = 11-011 Sheet Size: 24" x 36" Title LOWER FLOOR PLAN Sheet No.: A1.2 WEST ELEVATION ( �0- SOUT�HEL EVATION 1 /4" = 1 '-0" NORTH ELEVATION 1 /4" = 1 '-0" MANUFACTURED ALUMINUM GUARDR MAX. POST SPACING DECK SECTION AND TENSION TIE TRUCTURAL \. ALL THREADED CREW (STD.) TIPPED GALV. RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PACIFIC LIVING CONSTRUCTION LLC P.O. Box 15841 Seattle, WA 98115 t: 206.678.5477 www.pacificlivingconstruction.com Project Title: CANO RESIDENCE 20030 88TH AVE W EDMONDS, WA 98026 Project No.: 2020022 Drawn By: SP Issue PERMIT Date: 12.14.20 Scale: AS NOTED Sheet Size: 24" x 36" Title ELEVATIONS Sheet No 1 /4" = 1 '-0" 1" = 1'-0" A1.3 STRUCTURAL NOTES O C (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: DECK 9 PSF LIVE LOADS: SNOW LOAD 25 PSF DECK 60 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). EARTHQUAKE LOADS: EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-10 SECTION 12.8. SITE CLASS (ASSUMED) D SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.277 ONE SECOND SPECTRAL RESPONSE ACCEL (SI) 0.500 SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 0.851 ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.500 RISK CATEGORY II SEISMIC IMPORTANCE FACTOR (IF) 1.0 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM CANT WOOD COLUMNS RESPONSE MODIFICATION FACTOR, (R) 1.5 REDUNDANCY FACTOR (p) 1.0 SEISMIC RESPONSE COEFFICIENT (CS) 0.567 W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-10 SECTION 12.7.2. ID BASE SHEAR (V), V = CSW = I W WIND LOADS: BASIC WIND SPEED (3 SECOND GUST) 110 MPH EXPOSURE B I<ZT 1.35 SEE PLANS FOR ADDITIONAL DESIGN LOADS. FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: REPORT NOT AVAILABLE AT TIME OF DESIGN ALLOWABLE SOIL PRESSURE LATERAL EARTH PRESSURE: UNRESTRAINED: RESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 1500 PSF 35 PCF + ANY APPLICABLE SURCHARGE 50 PCF + ANY APPLICABLE SURCHARGE 300 PCF 0.35 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557-00. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. ,�il►100:19: ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD SLABS ON GRADE 3000 PSI 0.55 5 1/2 SACK N/A FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A WALLS 4000 PSI 1 0.45 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. *PROVIDE Pc SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI 318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) #5 EACH SIDE AND (1) #5 x 4'-0" DIAGONAL AT EACH CORNER. EXTEND BARS T-0" BEYOND EDGE OF OPENING. IF T-0" IS UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR 1 #1 1 1200 1 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 11.1.3. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE OTHER PT WOOD WOOD G90 X X X G185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.4. GLUE -LAMINATED TIMBER GLUE -LAMINATED TIMBER SHALL BE DOUGLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE FOLLOWING MINIMUM STANDARDS: SPAN COMBINATION Fb SIMPLE SPAN BEAMS 24F-V8 2400 PSI CANTILEVER OR MULTI -SPAN BEAMS 24F-V8 2400 PSI EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 212112020 CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS J PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. Q GENERAL Z H STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND O MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND cn H CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. U (n CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION C) � OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL Ld N PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL N ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS Y ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT < SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF DESIGN: ZSH CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. DRAWN: ATD CHECK: CMJ JOB NO: 20451.10 _ DATE: 1 2/21 /2020 Hardware and fasteners in contact with ■ ' preservative -treated wood shall be of hot -dipped zinc galvanized steel ■ ' stainless steel, silicon bronze or copper. I In the absence of manufacturer's • ' recommendations a minimum of ASTM A 653 I type G185 zinc -coated galvanized steel, or ■ ■ equivalent, shall be used. I IRC R317.3.1 IBC 2304.10.5.1 ■ RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Y C� W Cq W W 00 U Q Q W 0 = N W 0 O MZ O Z O :2 Q 0 0 U N w SHEET: S1.1 N O Z O C 6' SIM @ FND (4) PLACES PT 412 HF#2 DECK FRAMING PLAN SCALE: 1/4" = V-0" TYPICAL DECK FRAMING PLAN NOTES: 3 PT 412 HF#2 N = N � N 2 X � X � X d N x� x N x Ict - a PT 4x12 HF#2 PT 2x6 HF#2 @ 16" OC 1. PROVIDE SIMPSON HUC HANGERS AT ALL BEAM TO BEAM CONNECTIONS UNO. v\ N LL 2 N c-I X 1 090 PT 4x12 HF#2 SIM @ FND 5 Hardware preservati i hot-dipl stainless sl In the a recommendal type G 185 zi equl I IRC R ti � 40 67�O�CP PT 412 HF4 T-0" 0 T-0" PT 2x12 HF#2 LEDGER; ATTACH TO EXIST RIM W/ (3) SIMPSON 1/4" 0 x 3" SDS SCREWS @ 12" OC ATTACH JOIST TO CONT LEDGER W/ SIMPSON LUS SERIES HANGERS DECKING PER ARCH DECK JOIST PER PLAN; SLOPE PER ARCH SIMPSON DTT1Z @ 6'-0" OC MAX W/ (1) 3/8"0 SIMPSON SDWH DECK SECTION SCALE: 1" = V-0" GUARDRAIL POST AND CONNECTION BY OTHERS COUNTERSINK BOLT THIS END BEAM PER PLAN 3" MIN DECK SECTION SCALE: 1" = V-0" EXIST HOUSE FRAMING EXIST JOISTS PER ARCH ALIGNED BLKG AT GUARDPOST LOCATIONS W/ (1) SIMPSON DTT2Z TENSION TIE ­. ,'ING; (4) BAYS MIN GUARDRAIL POST AND CONNECTION BY OTHERS e 0 COUNTERSINK BOLT THIS END BEAM PER PLAI DECK SECTION SCALE: 1" = V-0" 8"x8" CONCRETE PLINTH W/ (4) #3 TIES EQ SPACED (4) #4 HOOKED bo DOWELS 6" cc u T-0" T-0" @ SIM SECTION V-0" @ STAIR LANDING POST PER ARCH ALIGNED JOIST AT GUARDPOST LOCATIONS W/ (1) SIMPSON DTT2Z TENSION TIE 3T PER PLAN; R ARCH LUS HANGER COL PER PLAN AND SCHED SIMPSON MPB66Z POST BASE; ABU POST BASE @ SIM SECTION _ z �2 (3) #4 BOT, EA WAY, (2) #4 BOT, EA WAY @ SIM SECTION TYPICAL DECK FOOTING DETAIL SCALE: 1" = V-0" RECEIVED Jan 29 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 212112020 Y ry Q DESIGN: ZSH DRAWN: ATD CHECK: CMJ JOB NO: 20451.10 DATE: 1 2/21 /2020 Y W 0 3:: cq O LJJ L. j 00 0) U Q Q L1J 0 N W 00 cri 0 O MZ O z o :2 Q o 0 U N w SHEET: zN Q ^_ Q f ^ W V M Z Q Q O L j_ �-- U D U cy LLJ F- 0 (n S2ml