Loading...
BLD2021-0162+Interior_Lighting_Summary+1.28.2021_1.52.22_PM+2017645over 2019 Project Info Project Title: Dr. Zach Streit Date 1/1/2018 Compliance Applicant Information. Provide contact information for individual who can For SDCI Use forms do not respond to inquiries about compliance form information provided. require a password to 1.21 Company Name: Obsidian Design, LLC Company Address: 5921 SE Cedar St. use. Instructional and Applicant Name: Chelsea Rodgers calculating cells are write- protected. CITY OF Applicant Phone: APP 503-539-3657 DEVEL SERVICES Applicant Email: obsidiandesignpdx@gmail.com Project Description I� 0 New Building 0 Addition 0 Alteration 0 No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System Description B D2I 0 Interior Lighting Plans Included Interior Lighting Power 0 Building Area Method 0 Space -by -space Method Allowance Method Select method used in project. Interior Lighting Permit Q Before January 1, 2018 January 1, 2018 or after Date Select date range for the initial building permit application or initial TI permit acceptance Interior Lighting Controls 0 All C405.2.1- C405.2.8 Lighting Controls 0 C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) 0 Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with required controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: 46 No Dwelling Lighting 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units 10 C406.3 High Efficacy Lighting 10 R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with SEC Residential provisions in lieu of SEC Commercial provisions. Exterior Lighting System Description 0 Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable 0 0 provisions as a stand alone new construction project Refer to Section C502.2.6 for additional Lighting systems in addition are combined with existing 0 0 requirements. building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT--BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXTform. EIVED 9.21 EDMONDS JPMENT )EPARTMENT 021-0162 REVIEWED BY CITY OF EDMONDS over Project Title: Dr. Zach Streit Date 1/1/2018 Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Spaces with more lighting than threshold added, altered or replaced Lighting Alterations (20% int., 50% garage, 50% ext.) Spaces with less lighting than threshold added, altered, or replaced Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes (20% int., 50% garage, 50% ext.) multiple spaces (rooms separated by ceiling height partitions), each space where less than 20% of the existing Lamp and/or ballast replacement only _ existing total wattage not increased 0 v 0 More lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures fixtures are added, altered or replaced can be combined on a single LTG-INT- shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain SPACE form. Spaces where 20% or fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. more of the fixtures are added, altered or replaced and additions maybe combined onto one lighting power compliance form, Parking garages and exterior lighting have 50% thresholds. Less lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. The threshold for interior lighting is 20% of the luminaires within an enclosed space, for parking garages the threshold is 50% of the luminaires within the garage, and for exterior spaces the Refer to Section C503.6 for additional threshold is 50% of the total installed lighting power for the exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting requirements. New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) 0 0 0 All alteration lighting controls shall be commissioned per C408.3. New or moved lighting panel 0 0 0 Interior space is reconfigured - luminaires unchanged or relocated 0 7- New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application 0 No changes are being made to the interior or exterior lighting systems and existing space specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed. space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured over Project Title: Dr. Zach Streit Date 1/1/2018 Calculation NOTE 9 Area 40 New Construction 0 Addition - 0 Addition stand alone + existing o Spaces where < 20% of o Spaces where z 20% of 0 Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) For SDCI Use LPA Calculation Type Standard Additional Efficiency Package Option C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting Wattage N1E1 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ftz Watts Allowed (watts/fe x area) 100,101 Seating area, general 9' -01, 226 0.390 88 102 Restroom: all other 9' -01, 51 0.700 36 103 Breakroom (see Lounge/breakroom) 9' -01, 70 104 Restroom: all other 9' -01, 53 0.700 37 105 Corridor: all other 9' -01, 285 0.480 137 106 Health care facility: Nurse station 9' -0" 85 0.570 48 107 Health care facility: Imaging room 9' -01, 65 1.060 69 108 Storage room 9' -01, 64 0.450 29 109,110 Health care facility: Exam/treatment 9' -01, 208 1.330 277 111 Health care facility: Exam/treatment 9' -01, 118 1.330 157 112,113 Health care facility: Exam/treatment 9' -01, 194 1.330 258 114 Health care facility: Exam/treatment 9' -01, 121 1.330 161 Total Area 1540 Retail Display Allowance from LTG-INT-DISPLAY Lobby Art/Exhibit Display Allowancefrom LTG-INT-DISPLAY NOTE 8 Allowed Watts 1297 Proposed Lighting Wattage 11TE3 Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 1 Watts Proposed 100,101 led pendant 12 15 180 102 6" led can 2 15 30 103 6" led can 4 15 60 104 6" led can 2 15 30 105 6" led can and LED Pendant 13 15 195 106 6" led can 4 15 60 107 6" led can 2 15 30 108 6" led can 2 15 30 109,110 6" led can 6 15 90 111 6" led can 2 15 30 112,113 6" led can 4 15 60 114 6" led can 4 15 60 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1 855 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busmay systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-INT-DISPLAYform only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas.