Engineering Letter - Distinctive Dentistry - 6-18-21FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter 06-18-2021 Big Sky Northwest 19560 381h Ave NE Lake Forest, WA 98155 Attn: Dustin Long RE: Distinctive Dentistry 22815 Edmonds Way, Edmonds, WA 98020 This letter is to confirm that Froelich Engineers, Inc. has reviewed information provided by Dustin Long ( Big Sky Northwest) and Phil Showstead for the Distinctive Dentistry to verify that the construction modifications are structurally acceptable. This letter only approves sections noted in this letter on information provided by the contractor. Outside of this scope has not been reviewed and this letter does not cover them. See attached calculations for ceiling joist and new beam at end of letter showing structural adequacy of the framing. Sketch 1 and typical section show the layout of area of remodel with existing members and new framing noted. Beam framing sketch shows the connections from the new beam and new columns to the existing framing. Pictures 1-4 show existing framing matches sketch 1, typical section, and beam framing sketch Where joists have been cut along the new corridor provide 2x10 ceiling joist spanning between the two beams and attached on each end to joists with (3) 0.148x3" nails. Conditions shown in attached letter are structurally acceptable fix for the remodel of the Distinctive Dentistry in Edmonds Washington. Please feel free to contact our office if you have any questions. Faramarz Dean Azimi, PE, SE Principal www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter Sketch 1 A....................................... OMEC6. (E) CONT 2 5 WEDGED S ITWEENROOFJ01$TS AND ® - - - O' - - - o - O ' ® 1 !i p 1- - - CEILING JOISTS OP `2 .OP #1 - 1 1-0 9 E ........ CBCT ®--z F1077 11 v 4x4 fir . C:> P .... y VT O M . . . ILE SCAHO T1 EC7 RIDGE gpgN0 0iNEGTDT SITTING ON CEILING JOI6T6 . . . . . . . . . . . . . . . . 106 .k . .... . ®.. ®. OP ak P ®® 4x6 fir ---- Post IE1 CONT 1X WEDGED BETWEEN ROOF JOISTS AND- ® ®. - ^ - - A/ - - ®. - - GELINGJOIST5 e. • HALL 105 0 Y................................ ... 15' 4x14 oa slam beam 144.10 paraiam beam (E) 2X4 ROOF RAFTER (E) DBL 2X10 CEILING JOIST Typical Section tE) CONT (2) 2X10 RIDGE BOARD DIRECTLY SITTING (E) CONT 2X6 WEDGED ON CEILING JOISTS BETWEEN ROOF JOISTS AND CEILING JOISTS (x� (N) 3.112X9 1/4 PSL 2.0 r� TYP (N)H2.5A CLIP EA JOIST TYP WHERE CEILING JOIST IS CUT ALONG THE CORRIDOR PROVIDE MINIMUM 2X10 SPANNING ACROSS THE (2) BEAMS WITH (3) 0.148X3- NAILS INTO DBL CEILING JOIST ON EACH END www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter Beam Framing (drawn by other) www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter Picture 1 i lm www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter Picture 2 www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL • STRUCTURAL Structural - Engineering Letter Picture 3 www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 FROELICH ENGINEER S CIVIL STRUCTURAL Structural - Engineering Letter Picture 4 •:ems._ � !�� j / . , y r G p -fir, —`'__ _- I www.froelich-enqineers.com 10 MAIN OFFICE 17700 SW Upper Boones Ferry Road, Suite 115 Portland, Oregon 97224 503-624-7005 Q CENTRAL OREGON 745 NW Mt. Washington Drive, Suite 204 Bend, Oregon 97703 541-383-1828 10 DENVER OFFICE 1333 W. 1201h Avenue, Suite 109, Westminster, Colorado 80234 720-799-1001 WoodWorks ®R COMPANY PROJECT SOFTWARE FOR WOOD DESIGN June 17, 2021 08:57 Ceiling Joist Design Check Calculation Sheet Wood Works Sizer 2019 (Update 1) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Loadl Dead Point 6.00 240 lbs Load2 Snow Point 6.00 300 lbs Self -weight Dead Full UDL 6.6 plf Unfactored• Dead Snow Factored: 160 151 159 149 Total 310 309 Bearing: Capacity Beam 937 937 Support 1055 1055 Des ratio Beam 0.33 0.33 Support 0.29 0.29 Load comb #2 #2 Length 0.50* 0.50* Min req'd 0.50* 0.50* Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.13 1.13 Fcp sup 625 625 Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 17 Fv' = 207 psi fv/Fv' = 0.08 Bending(+) fb = 488 Fb' = 649 psi fb/Fb' = 0.75 Live Defl'n 0.06 = < L/999 0.40 = L/360 in 0.14 Total Defl'n 0.14 = < L/999 0.60 = L/240 in 0.23 ❑ WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN Ceiling Joist WoodWorks® Sizer 2019 (Update 1) Page 2 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv' 180 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 1000 1.15 1.00 1.00 0.513 1.100 - 1.00 1.00 1.00 - 2 Fcp' 625 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.7 million 1.00 1.00 - - - - 1.00 1.00 - 2 Emin' 0.62 million 1.00 1.00 - - - - 1.00 1.00 - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D+S Bending(+): LC #2 = D+S Deflection: LC #2 = D+S (live) LC #2 = D+S (total) Bearing Support 1 - LC #2 = D+S Support 2 - LC #2 = D+S D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.2 CALCULATIONS: V max = 310, V design = 305 lbs; M(+) = 1739 lbs-ft EI = 168.18e06 lb-in^2/ply "Live" deflection is due to all non -dead loads (live, wind, snow...) Total deflection = 1.5 dead + "live" Lateral stability(+): Lu = 12.00' Le = 22.06' RB = 33.0; b = single ply width Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2018), the National Design Specification (NDS 2018), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 4. BUILT-UP BEAMS: it is assumed that each ply is a single continuous member (that is, no butt joints are present) and that each ply is equally top -loaded. Where beams are side -loaded, special fastening details may be required. 5. FIRE RATING: Joists, wall studs, and multi -ply members are not rated for fire endurance. Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. Title Block Line 6 Printed: 17 JUN 2021, 9:05AM Wood Beam File: New Beam.ec6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 DESCRIPTION: New Beam CODE REFERENCES Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Fb + 2900 psi E : Modulus of Elasticity Load Combination ASCE 7-10 Fb - 2900 psi Ebend- xx 2000 ksi Fc - Prll 2900 psi Eminbend - xx 1016.535 ksi Wood Species : iLevel Truss Joist Fc - Perp 750 psi Wood Grade : Parallam PSL 2.0E Fv 290 psi Ft 2025 psi Density 45.07 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling HAW(% 3.5x9.25 Span = 15.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Uniform Load : D = 0.150, S = 0.1880 , Tributary Width =1.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.685 1 Maximum Shear Stress Ratio = 0.316 11 Section used for this span 3.5x9.25 Section used for this span 3.5x9.25 fb: Actual = 2,285.55psi fv: Actual = 105.45 psi Fb: Allowable = 3,335.00psi Fv: Allowable = 333.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 7.500ft Location of maximum on span = 14.234 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.467 in Ratio = 385>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.839 in Ratio = 214 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb Fb V N Fv D Only 0.00 0.00 0.00 0.00 Length = 15.0 ft 1 0.389 0.179 0.90 1.000 1.00 1.00 1.00 1.00 1.00 4.22 1,014.30 2610.00 1.01 46.80 261.00 +D+S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 15.0 ft 1 0.685 0.316 1.15 1.000 1.00 1.00 1.00 1.00 1.00 9.51 2,285.55 3335.00 2.28 105.45 333.50 +D+0.750S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 15.0 ft 1 0.590 0.272 1.15 1.000 1.00 1.00 1.00 1.00 1.00 8.18 1,967.73 3335.00 1.96 90.79 333.50 +0.60D 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 15.0 ft 1 0.131 0.061 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.53 608.58 4640.00 0.61 28.08 464.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. °+° Defl Location in Span +D+S 1 0.8388 7.555 0.0000 0.000 Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Wood Beam DESCRIPTION: New Beam Vertical Reactions Project Title: Engineer: Project ID: Project Descr: Support notation : Far left is #1 Printed: 17 JUN 2021, 9:05AM Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 2.535 2.535 Overall MINimum 1.410 1.410 D Only 1.125 1.125 +D+S 2.535 2.535 +D+0.750S 2.183 2.183 +0.60D 0.675 0.675 SOnly 1.410 1.410