REVIEWED FIR 2021-0100+Fire_Sprinkler_Equipment_Specification_Sheets+9.10.2021_6.25.21_PM+2403318Victaulic° FireLock"m Series FL-QR/DRY/ST Dry, Quick Response ✓ctaulic° Pendent and Recessed Pendent, K11.2 (16.0) 45.04 1.0 PRODUCT DESCRIPTION QUICK RESPONSE PENDENT DRY SPRINKLERS SIN V4002 ORIENTATION Pendent K-FACTORI 11.2Im ./16.1 S.I. CONNECTION 1" NPT/25mm BSPT/1" IGS MAX. WORKING PRESSURE 175 psi (1200 kPa) ESCUTCHEON Plain/Flush/Sleeve and Skirt QUICK RESPONSE RECESSED PENDENT DRY SPRINKLERS SIN V4002 ORIENTATION PENDENT K-FACTORI 11.2Im ./16.1 S.I. CONNECTION 1" NPT/25mm BSPT/1" IGS MAX. WORKING PRESSURE 175 psi (1200 kPa) ESCUTCHEON Recessed Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. Operating Pressure: UL: 7 psi/48 kPa/.5 bar Temperature Rating: See tables in section 2.0 ' For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. virtaulir._rnm 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. 1 ✓ctaulic° victaulic.com 2.0 CERTIFICATION/LISTINGS C&US LISTED APPROVALS/LISTINGS SIN V4002 V4002 Nominal K Factor Imperial 11.2 11.2 Nominal K Factor S.I 2 16.1 16.1 Orientation Pendent Pendent Escutcheon Plain/Flush/Slv & Skt Recessed Approved Temperature Ratings F°/C° cULus 155°F/68°C 175°F/79°C 2007/93°C 286°F/141°C 155°F/68°C 175°F/79°C 200oF/93°C 286°F/141°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTE • Listings and approval as of printing. COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL V4002 Storage Type NFPA Open Frame (that is, no solid shelves) Single, Double, Multiple -Row, or Portable Rack Storage of Class I -IV and Group A or B Plastics NFPA 13 Solid Pile or Palletized Storage of Class I -IV and Group A or B Plastics NFPA 13 Idle Pallet Storage NFPA 13 Rubber Tire Storage NFPA 13 Rolled Paper Storage (Refer to the standard.) NFPA 13 Flammable Liquid Storage (Refer to the standard.) NFPA 30 Aerosol Storage (Refer to the standard.) NFPA 30B 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ ctaulil 3.0 SPECIFICATIONS - MATERIAL Deflector: Brass or Stainless Steel Bulb Nominal Diameter: 3.Omm Split Spacer: Stainless Steel Load Screw: Brass Pip Cap: Stainless Steel Spring Seal Assembly: PTFE coated Beryllium nickel alloy and stainless steel Frame: Brass Inlet Fitting: Brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless Steel Orifice Insert: Stainless Steel Escutcheon/Plate: Stainless steel Torsion Spring: SST wire Installation Wrench: Ductile iron Sprinkler Frame Finishes: • Plain brass • Chrome plated • White polyester painted3, 4 • Bright White polyester painted3, 4 • Flat black polyester painted3, 4 • Custom polyester painted3, 4 • VC-2505 3 Not available on the Intermediate Level Style Pendent. 4 UL Listed for corrosion resistance. 5 UL Listed and FM Approved for corrosion resistance. NOTE • Weather resistant escutcheon available upon request. • For cabinets and other accessories refer to separate sheet. Spring seal assembly Torsion spring Inlet fitting Innertube Outer tube Orifice insert Escutcheon Split spacer Pip cap Bulb Frame Load screw Deflector Spring seal assembly Torsion spring Inlet fitting Innertube Outer tube Orifice insert Escutcheon Split spacer Pip cap Bulb Frame Load screw Deflector Material Specifications V4002 Material Specifications V4002 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com 4.0 DIMENSIONS Tee with same outlet size F t ! as sprinkler thread size. See "Important Installation Information", later in this 1..1----4..I document. 1" NPT/BSPT 1 3/4"/ 44 m m i Plain Barrel,Threaded V4002 Tee with same outlet size as sprinkler thread size. i k-See"Important Installation Information" later in this I--4----1--I document. I" N PT/BS PT y 13/a''/44 mm Min. Hole in ceiling Typical ceiling 3'/e"/99 mm `Finished surface 25/�s°/58 mm F 33he"/81 m m --I Sleeve and Skirt, Threaded V4002 g 3'/s"/99 mm 25/,s'/58 mm 1" Weld outlet. See f`"fit' a "Important Installation Information" with i n ® this document. A-----y 44 m m i Plain Barrel, Grooved V4002 V Weld outlet. See "Important Installation Information within this document. /44 mm Min. riole in ceiling Typical ceiling F33/e"/81 mm -I Sleeve and Skirt, Grooved V4002 Finished surface Dry Sprinkler Take Out Dimensions "A" Flush Recessed Sleeve & Skirt Length 1" NPT/1"BSPT inches IGS Grooved inches 1"NPT/1"BSPT inches IGS Grooved inches 1"NPT/1"BSPT inches IGS Grooved inches inches mm mm mm mm mm mm mm 12 12.00 13.14 12.50 13.64 10.98 12.03 300 304.8 333.8 317.5 364.4 276.6 305.6 18 18.00 19.14 18.50 19.64 16.89 18.03 450 457.2 486.1 469.9 498.8 429.0 458.0 24 24.00 25.14 24.50 25.64 22.89 24.03 600 609.6 613.2 622.3 651.3 518.4 610.4 30 30.00 31.14 30.50 31.64 28.89 30.03 750 762.0 791.0 774.7 803.7 733.8 762.8 36 36.00 37.14 36.50 37.64 34.89 36.03 900 914.4 943.4 927.1 956.1 866.2 915.2 NOTE • IGS "A" dimensions are measured to the end of the pipe. • All three escutcheon options of the matching finish will be included with each sprinkler (see sprinkler finishes). 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com M ✓ ctsullic° victaulic.com 4.0 DIMENSIONS (CONTINUED) 1" Weld outlet Tee with same outlet size See"Important Installation r as sprinkler thread size. 1 1 nfor document this R' See"Important Installation I document Information, within this i L 1 i L*W document 1"NPT/BSPT --r--- q 11/2738 mm Min. A - - 1 Yz"/38 mm Min. Hole in ceiling Hole in ceiling _ v4°/ 6 mm � Typical ceiling Ya"/ � Typical r6 mm ceiling 27 i 27 1 51 mm Finished surface 51 mm Finished surface 3"/ TV 76 mm 76 mm Flush, Threaded Flush, Grooved V4002 V4002 Tee with same outlet size as sprinkler thread size. See"Important Installation Information, later in this document. 'T/BSPT q 2751 mm Min. Hole in ceiling T Typical ceiling 17/a"/48 mm T 1 %s"/28 m m Finished surface 27/s"/73 mm Recessed, Threaded V4002 1 " Weld Outlet. See "Important Installation Instructions within this document. 17/8"/48 mm L W-V 1%s"/28 mm 3 mm 27/s"/73 mm Recessed, Grooved V4002 2751 mm Min. Hole in ceiling Typical ceiling surface Flush Dry Sprinkler Take Out Dimensions "A" Recessed Sleeve & Skirt Length 1" NPT/1"BSPT inches IGS Grooved inches 1"NPT/1"BSPT IGS Grooved inches inches 1"NPT/1"BSPT inches IGS Grooved inches inches mm mm 12.00 mm 13.14 mm mm 12.50 13.64 mm 10.98 mm 12.03 12 300 304.8 333.8 317.5 364.4 18.50 19.64 276.6 16.89 305.6 18.03 18 18.00 19.14 450 457.2 486.1 469.9 498.8 429.0 458.0 24 24.00 25.14 24.50 25.64 22.89 24.03 600 609.6 613.2 622.3 651.3 518.4 610.4 30 30.00 31.14 30.50 31.64 28.89 30.03 750 762.0 791.0 774.7 803.7 733.8 762.8 36 36.00 37.14 36.50 37.64 34.89 36.03 900 914.4 943.4 927.1 956.1 866.2 915.2 NOTE • IGS "A" dimensions are measured to the end of the pipe. • All three escutcheon options of the matching finish will be included with each sprinkler (see sprinkler finishes). 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaill victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from-67°F/-55°C. 1-40: Victaulic FireLockTm Automatic Sprinklers Installation and Maintenance Instructions I-V9: Style V9 Victaulic FireLockTIM IGSTM Installation-ReadyTM Sprinkler Coupling Installation Instructions User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 45.04 16394 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com L ✓ctsulicr