Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-0924+Manufacturer_Specifications_and_Installation_Instructions+6.30.2021_6.19.21_PM+2278355
Job Name: DR. LEE - EDMONDS System Reference: FCU-1/HP-1 Date: 6/26/2021 FCU-1 II i�lTAWE � II,Ia�011111111111111111111111�011�. ..., dIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIICIIh�. dl IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII HP-1 III'�hllllllllllllllllllllllllllllllllllllll�i�lll�' 0 I,pllllllllllllllllllllllllllllllll IIII ngllllllllllllllllllm flll Fx Indoor Unit TPEADA0301AA70A .................................................. Outdoor Unit ° Standard Model........................„..„..„..,.TRUZA0301HA70NA ° Seacoast Model TRUZA0301 HA70BA ....................................... RECEIVED BLD2021-0924 Jul 02 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT INDOOR UNIT FEATURES • Unobtrusive ceiling -concealed design for short -run ductwork • Wide ranging external static pressure (0.14-0.60 in. WG) • Built-in condensate lift mechanism (up to 27-9/16") • Auto fan speed mode • Optional FB Series filter boxes for easy access and service • Ideal for residential homes, retail shopping centers, larger classrooms, office complexes, conference rooms, ballrooms, fitness centers, and more • Multiple control options available: o kumo cloud° smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Power receiver pre -charged with refrigerant volume for piping length up to 70 ft • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity BTU/H 30,000 Rated Capacity BTU/H 30,000 Minimum Capacity BTU/H 9,000 Maximum Power Input W 3,000 Rated Power Input W 3,000 Moisture Removal Pints/h 8.6 Sensible Heat Factor 0.68 Power Factor % 93.8/93.8 Heating at 47°F Maximum Capacity BTU/H 34,000 Rated Capacity BTU/H 32,000 Minimum Capacity BTU/H 8,800 Maximum Power Input W 2,550 Rated Power Input W 2,490 Power Factor % 93.3/93.3 Heating at 17°F3 Maximum Capacity BTU/H 21,200 Rated Capacity BTU/H 18,500 Maximum Power Input W 2,100 Rated Power Input W 1,980 Heating at 5°F4 Maximum Capacity BTU/H 17,700 Maximum Power Input W 1,800 Efficiency SEER 19.1 EER' 10.0 HSPF [IV] 10.8 COP at 47°F2 3.76 COP at 17°F at Maximum Capacity3 2.96 COP at 5°F at Maximum Capacity4 2.88 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 25 Recommended Wire Size [Indoor - Outdoor] AWG 14 Indoor Unit MCA A 2.73 Fan Motor Full Load Amperage A 2.18 Fan Motor Output W 121 Airflow Rate at Cooling, Dry CFM 618-742-883 Airflow Rate at Cooling, Wet CFM 556-668-795 Airflow Rate at Heating, Dry CFM 618-742-883 Sound Pressure Level [Cooling] dB[A] 30-34-39 Sound Pressure Level [Heating] dB[A] 30-34-39 External Static Pressure in.WG 0.14-0.2-0.28-0.4-0.6 Drain Pipe Size In. [mm] 1-1/4 [32] Condensate Lift Mechanism, Maximum Distance In. [mm] 27-9/16 [700] Coating on Heat Exchanger — Extemal Finish Color Galvanized Unit Dimensions W x D x H: In. [mm] 43-5/16 x 28-7/8 x 9-7/8 [1100 x 732 x 250] Package Dimensions W x D x H: In. [mm] 53-3/16 x 34-11/16 x 13-7116 [1350 x 880 x 341] Unit Weight Lbs. [kg] 69 [31] Package Weight Lbs. [kg] 82 [37] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 95 DB, 71 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) "F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Heating at -4°F (Indoor H Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor H Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. » Wind baffles required to operate below 23°F DB in cooling mode. » Cooling -only system with wind baffle: -40°F - 115°F. » Heat pump system with wind baffle: 0°F - 115°F. » Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (TRU*AO*******BA MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 19.0 A 26 Fan Motor Full Load Amperage A 0.4 86 Fan Motor Output W Airflow Rate CFM 1940/1940 LEV Refrigerant Control Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling' dB(A) 47 Sound Pressure Level, Heating2 dB(A) 48 Compressor Type INVERTER -driven twin rotary Compressor Model SNB172FWHM1 Compressor Rated Load Amps A 7.0 Compressor Locked Rotor Amps A 11.0 Compressor Oil Type // Charge oz. FV50S // 23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater N/A Unit Dimensions W x D x H: In. [mm] 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 9431 Package Dimensions W x D x H: In. [mm] 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033] Unit Weight Lbs. [kg] 153 [69] Package Weight Lbs. [kg] 179 [81] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* 'F 115 DB / 0 DB Heating Air Temp [Maximum / Minimum] °F 70 DB, 59 WB / -4 DB, -4 WB Heating Thermal Lock -out / Re -start Temperatures** °F -8.0 / -4 Refrigerant Type R410A Charge Lbs, oz 7,11 Chargeless Piping Length Ft. [m] 70.0 [20.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.7 [50] Piping Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Maximum Piping Length Ft. [m] 165 [50] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47*F (Indoor // Outdoor) *F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Heating at 4*F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5*F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -130F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. » Wind baffles required to operate below 23'F DB in cooling mode. » Cooling -only system with wind baffle: -40°F - 115*F. » Heat pump system with wind baffle: 0°F - 115*F. » Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (TRU*AO*******BA MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. FCU-1 Opposite piping 378(14-15/16) 153(6-1/16) side view Fresh air intake o100(3-15/16) Drain pipe O.D 032 1-1/4 knock out hole (Emergency drain) 120� Note 4 Bottom t 3-02.9 1/8 mount hole p125 � it, t4.15116) � SS'^� Note 1.1-Ise an M10 screw for the suspension bolt (field supply). 2.Keep the service space for maintenance at the bottom. 3.This drawing is for 24-30-36-42 KBTU/H inlet air models,which have 2 fans. side view 09 12-15-18 KBTU/H models have 1 fan. d If th< inlet r1..,f ie .—H — - - - fh< air liter (supplied with the unit), then nstall the filter (Feld supply) at the >uction side. Heat air to 0°C (32T) or higher when aking fresh air with a fresh air intake. Unit:mm(in.) Model J I Gas pipe 12 Liquid pipe 09 KBTU/H 62 09.52 06.35 (2-1/2) (3/8) (1/4) 12,15,18 62 012.7 06.35 KBTU/H (2-1/2) (1/2) (1/4) 24,30 KBTU/H 66 (2-5/8) 015.88 (5/8) 09.52 (3/8) 36,42 KBTU/H Unit:mm(in.) Model A B C D E F G H 09,12,15,18 KBTU/H 900 (35-7/16) 954 (37-9/16) 1000 (39-3/8) 860 (33-7/8) 800 9 (31-1/2) 858 (33-13116) 72 (2-7/8) 24,30 KBTU/H 1100 1154 1200 1060 11 1000 1058 (43-5/16) (45-7/16) (47-1/4) (41-3/4) (39-3/8) (41-11116) 78 36,42 KBTU/H 1400 1454 1500 1360 1300 14 1358 (3-1/8) (55-1/8) (57-1/4) (59-1/16) (53-9/16) (513/16) (53-1/2) Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1 FREE SPACE (Around t 14 PIPING -WIRING DIRECTIONS The diagram below shows a Dimensions of space needed Please secure the unit firmly Piping and wiring connections basic example. for service access are with 4 foundation (M10<W316>) bolts. can be made from 4 directions: Explantion of particular details are shown in thebelow diagram. (Bolts and washers must be FRONT,Right,Rear and Below. given in the installation manuals etc. purchased locally.) ® <Foundation bolt height> Min. 10 <T . � ^ FOUNDATION j Serviced ' s ace Min. M 500 <19-11/16> Example of Notes 8 Refrigeranl GAS pipe connection (FLARE) e15.88(5 2 Refrigerant LIQUID pipe connection(FLARE) a9.52( '1 Indication of STOP VALVE connection location. Piping knockout Hole Details Pawersupplywidng hde Richt oioinc hde FORM# TPEADA0301 AA70A & TRUZA0301 HA70(N/B)A - 202102 Side Air Intake Rear Air Intake Unit: mm<in> L1 N knockout 51 C at�US Intertek Specifications are subject to change without notice. © 2021 Mitsubishi Electric Tirane HVAC US LLC. All rights reserved. Job Name: DR. LEE - EDMONDS System Reference: HP-2 Date: 6/26/2021 UNIT OPTION ° Standard Model TUMYPO6O1AK43NA Seacoast (BS) Mode[,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,TUMYPO6O1AK43BA ACCESSORIES ° Optional Defrost Heater ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,_PAC-SJ2OBH-E ° Drain Pan PAC-SH97DP-E r, ° Front Wind Baffle (One Piece)',,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,_WB-PA3 ° Air Deflector Vertical ADV-1 ° Air Outlet Guide (One Piece)",,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, PAC-SH96SG-E ° Header Kit,,,,,,,,,,,,,,,,,,,,,,,, ,,,,,,,,, for details see Pipe Accessories Submittal ° Joint Kit ,•,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,for details see Pipe Accessories Submittal `PUMY requires two outlet guides and two wind baffles for installation Specifications Unit Type Cooling Capacity (Nominal) BTU/H System i.0 60,000 Heating Capacity (Nominal) BTU/H 66,000 Guaranteed Operating Range Cooling'•2 OF [°C] 5.0-115.0 [-15.0-46.0] Heating OF [°C] -13-59 [-25.0-15.0] External Dimensions (H x W x D) In. [mm] 52-11/16 x 41-11/32 x 13+1 [1,338 x 1050 x 330+25] Net Weight Lbs. [kg] 302 [137] External Finish Galvanized sheets (+power coating for -BS type) <MUNSELL 3Y 7.8/1.1> Electrical Power Requirements Voltage, Phase, Hertz, Power Tolerance 208/230V, 1-phase, 60 Hz, Minimum Circuit Ampacity A 36.0 Maximum Overcurrent Protection A 45 Recommended Fuse Size A 40 SCCR kA 5 Refrigerant Piping Diameter Liquid (High Pressure) In. [mm] 3/8 [9.52] Flare Gas (Low Pressure) In. [mm] 314 [19.051 Flare Indoor Unit Connectable Total Capacity 50.0-130.0 % of outdoor unit capacity Model/Quantity PO4-P7211.0-12.0 Sound Pressure Levels d6(A) 58.0-59.0 Compressor Operating Range Cooling 28.0 % to 100.0 Heating 18.0 % to 100.0 Compressor Type x Quantity INVERTER -driven Scroll Hermetic x 1 Compressor Motor Output kW 3.9 Refrigerant Type x Original Charge R410A x 11 Ibs + 4 oz [5.1 kg] Protection Devices High Pressure Protection High pressure sensor, High pressure switch 601 psi (4.15 MPa) Inverter Circuit (Comp./Fan) Over -heat protection, Over -current protection Compressor Discharge thermo protection, Over -current protection Lubricant FVC68D (2.3 liters) AHRI Ratings (Ducted/Non-ducted) EER 11.1/13.3 SEER 17.8/20.0 COP 3.7/4.1 HSPF 10.7/12.0 NOTES: Cooling I Indoor: 81 ° F (27 ° C) DB 166 ° F (19 ° C) WB; Outdoor: 95 ° F (35 ° C) DB Heating I Indoor: 68' F (20° C) DB, Outdoor 45° F (7° C) DB / 43° F (6° C) WB 'When using Wind Baffles [WB-PA3], the minimum operating range is 5° F. Without Wind Baffles, the minimum operating range is 23' F 2When connecting PKFY-PO6NBMU/P08NHMU,PFFY-PO6/08/12NEMU or PFFY-PO6108/12NRMU indoor units, the minimum operating range is 50° F Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. HP - _ mod !� / ) NOTES: SEACOAST PROTECTION Anti -corrosion Protection: acoating treatment & appliedecondenser coil for protection from air contaminants. Standard: Salt Spray Test Method -_ unusual rust development _nm Sea Coast p>Salt Spray Test Method (JR_2)-munusual rust development _nm FORM TUM 9@,a pNBi @-22o @a Specifications are subbchange «n ! notice. c2ooMitsubishi om qer _ Aa A ±C All rights reserved. Job Name: DR. LEE - EDMONDS System Reference: FCU-2 Date: 6/26/2021 -;�0 GENERAL FEATURES • Single phase • Dual set point functionality • DC Motor • Static Pressure Features -Adjustable up to 1" - No change in static pressure with voltage change • Side access control panel • Flexibility in duct configuration • Choice of fan speed OPTIONS ❑ Joint Adapter (Port Connector)..... ❑ Drain pump ............................... ❑ External Heater Adapter .............. ❑ Filter Box (With 4" MERV 13 filter) Notes: ............CMY-R160C-J ......... PAC-KE05DM-F .CN24RELAY-KIT-CM3 ..........................FBH4-4 SPECIFICATIONS Capacity* Cooling...................................................72,000 Btu/h Heating...................................................80,000 Btu/h Power Power Source ........................208 / 230V, 1-phase, 60 Hz Power Consumption Cooling..........................................................0.63 kW Heating..........................................................0.63 kW Current Cooling.............................................................3.67/3.32A Heating.............................................................3.67/3.32A Minimum Circuit Ampacity (MCA) ................................. 7.7 A Maximum Overcurrent Protection (MOCP) Fuse ............ 15 A External Finish.............................Galvanized-steel Sheet External Dimensions Inches .............................. 18-9/16 H x49-1/4 W x44-1/8 D mm..........................................470 H x 1,250 W x 1,120D Net Weight Unit.......................................................214 Ibs / 97 kg Coil Type .........................................................Cross Fin (Aluminum Plate Fin and Copper Tube) Fan TypexQuantity..........................................SiroccoFanx2 Airflow Rate (Low-Mid-High)...............1,766 - 2,154 - 2,542 CFM External Static Pressure...... 0.20-0.40-0.60-0.80-1.00 "WG (External static pressure is factory set to 0.60"WG) Motor Type...............................................DC Brushless Motor Refrigerant Piping Dimensions Liquid (High Pressure)...................3/8" / 9.52 mm (Brazed) Gas (Low Pressure) ...................... 3/4"/ 19.05 mm (Brazed) Drainpipe Dimension..............................O.D. 1-1/4"/ 32 mm Sound Pressure Levels (Low -Mid -High) Low-Mid-High......................................36-39-43dB(A) * Cooling / Heating capacity indicated at the maximum value at operation under the following conditions: Cooling: Indoor 80T (27°C) DB / 67T (19°C) WB, Outdoor 95T (35°C) DB Heating: Indoor 70T (21 °C) DB, Outdoor 47T (8°C) DB / 43T (6°C) WB Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC 2X11-o31/8 holes 11:C-I d Terminal block M o� M II 0 X Air inlet M o `r o ,n n M 0 0 X O O 0 10 "' 71 � �, Knockout hole o2: (Power souse o �C 0 s !m iq =1 m t= E r n 0 T lic � o0 �M ncn rN r r 0 10 � m- �o 0 0 0 1034(40-3/4)(Suspension bolt pitch) 0 0 X t O o � c Air outlet`, o Suspension bolt hole I , • Nzp 0 Access door 0 Drain Piping. (IDrain hose o in M 170(6-1/4±114) nr;rn et1aX (Actual length) (9-13/16) 15 5/8 Access door Ceiling surface 12 -# 2X4-o3 1/8 holes Make the access door at the appointed position properly for service maintenance. 5'ao m m� m Note 1.1-11se M10 screw for the suspension bolt (field supply). X - 2.Keep the service space for the maintenance from the bottom o when the heat exchanger is cleaned. 3.Keep the service space for the maintenance from the bottom when the fan motor is changed. 4.Make sure to install the air filter (field supply) on the air intake side. 342 13-1/2 N t2 In case field supplied air filter is used, attach it hole N where the filter service is easily done. o M tv tvnel Unit:mm(in.) MODEL DGas i epLi uid pipe OO Drain hose TPEFYP072MH140A, 019.05(3/4) e9.52(3/8) Drain hose 3))2mm <Flex bleljoint> <accessory- TPEFYP096MH740A o22.2(7/8) ERV-1 0 RenewAire IIEnergy Recovery Ventilation SUBMITTAL Date: 6/28/2021 Project Name: Dr Lee - Edmonds Project Number: 0-062967 Job Location: Engineering Firm: Engineer: Contractor: Submittal Revision: 0 Unit Tags Model ERV-1 HE1.5JINH-SI5EE--- GNT --- L Submitted By Name: Date: Approved By Name: Approved By Signature: Date: ❑ Approved as Submitted ❑ Approved as Noted ❑ Rejected as Noted and Resubmit Once this submittal is approved or approved "as noted" a complete copy of this document must be returned to the RenewAire rep office before the equipment can be released for fabrication. An approval area has been provided for your convenience. Disapproval or approved "as noted" actions should be indicated on the appropriate individual submittal sheets. Date: 6/28/2021 Project Number: 0-062967 Project Name: Dr Lee - Edmonds Unit Tag: ERV-1 Model: HE1.5JINH-SI5EE--- GNT --- L Qty: 1 { '-A HE1.5XINH shown Configuration Specifications Ventilation Type: Typical Airflow Range: AHRI 1060 Certified Core CA Filters: RA Filters: Unit Weight: Unit Tag ERV-1 Model [HE1.5] HE1.5 Core Type []] G5 Installation Location [IN] Indoor Unit Airflow Orientation [H] Orientation H Wall [S] Single (Standard) Electrical Service [15] 208-230V / 1 Phase / 60 HZ Fresh Air Motor [E] ECM - Direct Drive Motorized Impeller Exhaust Air Motor [E] ECM - Direct Drive Motorized Impeller Flow Control [-] No Dampers (Standard) Unit Control [G] Terminal Strip For EC Motors Disconnect [N] Non Fused (Standard) Control Option [T] Transformer with Isolation Relay (Standard) Filter Monitor [-] None Paint [-] None Safety Listing [L] Listed Unit Accessories and Service Parts No accessories for this unit SUMMER ON us Intertek Static plate, heat and humidity transfer 375-1,575 CFM One L62-G5, One L125-G5 Total Qty. 2, MERV 8: 14" x 20" x 2" and 16"x20"x2" Total Qty. 2, MERV 8: 14" x 20" x 2" and 16"x20"x2" 337-504 lbs. (varies by option) Airflow Orientation Ii� m a 'Mm K# WINTER Outdoor Air Return Air Fresh Air Outdoor Air Return Air Fresh Air Standard Flow Rate SCFM Actual Flow Rate ACFM 409* 430* 395 408 395 409* 395 395 409 381* 403 397 Dry Bulb °F 85.3 75.0 76.9 25.2 70.0 61.9 Wet Bulb OF 65.2 62.5 62.8 20.5 54.3 48.5 Enthalpy (H) BTU/lb 30.2 28.3 28.5 7.4 22.8 19.5 Moisture Ratio (MR) grains/Ib 62.2 65.7 64.0 9.1 38.6 30.1 Fresh Air - External Static Pressure in w.g. 0.50 0.50 Exhaust Air - External Static Pressure in w.g. 0.50 0.50 Sensible effectiveness % 81.9 81.9 Total effectiveness % 76.9 78.6 Load savings ratio % 76.9 78.6 Moisture removed grains/lb -1.9 -21.0 Original load BTUH [Tons] Sen 4394 [0.4] Lat 902 [0.1] Tot 15296 [0.411 Sen 19112 Lat 1 8220 Tot 1 27332 Load with RenewAire BTUH [Tons] 797 [0.1] 446 [0.0] 11244 [0.111 3468 1 2386 1 5854 Total energy saved BTUH [Tons] 3597 [0.3] 455 [0.0] 14052 [0.311 15644 1 5834 1 21478 *Note: OA Flow Rate values are gross airflow, all others are net airflow. Note: For full certified ERV performance, please see AHRI 1060 Report. Note: Sensible cooling design conditions were used for the summer performance results Fans Gross Fan Signal Motors Protected by Motor Motors Protected by CFM ESP Filters (VDQ Watts Elevation Starters VFDs Qty @ HP FLA Qty @ HP FLA OA 409 0.50 2" MERV3.5 125 8 8 433 2@1.0 4.4 None RA 395 0.50 2" 8 3.5 122 Unit Electrical Data Volts Hertz Phase MCA MOP 208-230 60 1 9.9 15 Fan Curve HE7.5XINH (FA425 Watts, EA-122 Watts) 350 400 450 500 550 600 650 700 750 800 850 SUM OFA Watts Curve OFA ESP Curve OEA Watts Curve OEA ESP Curve •Fresh Air ESP ■ Fresh Air Watts -Exhaust Air ESP ♦Exhaust Alr Walls ERV-1 EA Damper Location (Optional) v �U Loi 32" C3 1 6 3/8" Typ. LEFT VIEW 18" X 18" Duct Receiving Flange Typ. Power Wiring Inlet 7/8" dia. Control Wiring Inlet 7/8" dia. FA Damper Location (Optional) 5 Fr 42 5/8" Case 1_ Patch Pan (Opening Used °LO° for Alternative > M C� I:flTyp. Unit Configurations) co O I I TOP VIEW 48 3/4" " Damper. Overall ames Typ. 3 1 /4" Door -interlocked Disconnect Switch 1 1 /8" Typ. FRONT VIEW Pressure Ports (4) Typ. r-----_� i N /,D or ing co E vE rfS�5wng ✓�l 24 1 /2" i 18" X 18" Duct Receiving Flange Typ. ABBREVIATIONS EA: Exhaust Air to outside OA: Outside Air intake RA: Room Air to be exhausted FA: Fresh Air to inside INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE 1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH. 2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. 3. MIN. DUCT CLEARANCE FROM DAMPER BLADE WHEN FULLY OPENED TO BE 2". SMACNA RULES APPLY. 20 1 /8"Minimum Service Area (Doors can be Removed from Hinges.) - L LO �o 32" 1 6 3/8" Typ. RIGHT VIEW Model: RA"#IRenewAire° T Drawing Type:e: Unit Dimension Version: MAY]8 all Energy Recovery Ventilation