Loading...
REVIEWED BLD2021-0473+Interior_Lighting_Summary+4.2.2021_3.53.33_PM+21257472018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2021 NEEA, All rights reserved Project & Applicant Information Project Title Thrive Kids Dentistry - 2018 WSEC For Building Department Use: I Date: Apr 02, 2021 Project Address 10032 Edmonds Way Suite 102 Edmonds, WA 98020 Applicant Name Alissa Johnson Applicant Phone 425-885-4300 Applicant Email alissa@magellanarchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Medical Building Cond. Floor Area 2,086 General Project Types Tenant Spaces — First Build Out New Building or Addition Lighting Scope g g p Interior Lighting Alteration Lighting Scope Project Cond. Floor Area 2,086 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description First time tenant improvement for a dental office including all new lighting. Lighting Compliance Scope Pro ect Type j yp Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Sco a p p Com Rance Method p LPA Calculation Adjustment Compliance Verification p and Method Tenant Spaces — First Build Out Interior Lighting Space by space No Calculation Adjustments selected COMPLIES Additional Efficiency Options Included 1'ro Thrive Kids Dentistry - 2018 WSEC ate Apr 02, 2 Lighting Power Calculation TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING Compliance Verification I COVIPLTES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Electrical/mechanical 37 0.43 16 Laboratory General 100 1.33 133 Lobby General 236 0.84 198 Lounge/breakroom General 133 0.59 78 Office Enclosed less than 250 sf 42 0.74 31 Office Open plan 130 0.61 79 Restroom General 89 0.63 56 Healthcare facility Corridor 283 0.71 201 Healthcare facility Exam/treatment room 1 1 528 1.40 739 Healthcare facility I Imaging room 57 0.94 54 Healthcare facility Operating room 244 2.26 551 Healthcare facility Recovery room 50 1.25 63 Proposed Total LPD 2159 Totals 2,200 2,159 COMPLIES Proposed Lighting Power Density Watts or Total Wafts Fixture Type Fixture ID Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Troffer LED 2x2 5 35 175 Troffer Recessed Linear LED 6 50 300 Troffer LED 2x4 8 50 400 Recessed downlight R2 3 18 54 Recessed downlight R4 5 14 70 Recessed downlight RI 32 18 576 Recessed downlight R3 10 14 140 Wall -mounted W2 1 30 30 Wall -mounted W 1 2 35 70 Other fixture type Exit Signage 5 4 20 Linear Fixtures LED strip LED Tape Light 54 6 324 Exempt Fixtures Medical & dental task LED Under Cabinet 2 Proposed Total LPD 2159 Project Title Thrive Kids Dentistry - 2018 WSEC Date Apr 02, 2021 Proposed Fixtures Details TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer LED 2x2 A2.2 LED New Fixture Description: LED 2x2 Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Troffer Recessed Linear LED I A2.2 LED New Fixture Description: Recessed Linear LED Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Troffer LED 2x4 A2.2 LED New Fixture Description: LED 2x4 Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight R2 I A2.2 LED New Fixture Description: Recessed adjustable LED Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight R4 I A2.2 LED New Fixture Description: 4" LED Recessed Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight Rl A2.2 LED New Fixture Description: RI Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Recessed downlight R3 I A2.2 LED New Fixture Description: 2" LED Recessed Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Wall -mounted W2 I A2.2 LED New Fixture Description: Wall Sconce Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Wall -mounted W 1 I A2.2 LED New Fixture Description: LED Wall Sconce Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Other fixture type Exit Signage A2.2 LED New Fixture Description: Exit Sign Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Linear Fixtures LED strip LED Tape Light I A2.2 I LED New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: LED Accent Lighting Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: Exempt Fixtures Medical & dental task LED Under Cabinet A2.2 New Fixture Description: LED Under Cabinet Light Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1