Loading...
FIR2021-0072+Fire_Alarm_Plan+7.14.2021_9.39.41_AM+2299404FIRE ALARM LEGEND NEW EXIST SYMBOL DESCRIPTION MANUFACTURER PART # MOUNTING ILI-F C D A E I M T E- E S 1 0 BPSx INTELLIGENT BOOSTER POWER SUPPLY POTTER PSN-64 SELF CONTAINED 9 0 XX STROBE - CEILING MOUNT XX - INDICATES DEVICE CANDELA SETTING POTTER CS-24x DEEP SINGLE GANG OR DOUBLE GANG 2 2 XX HORN/STROBE - CEILING MOUNT XX - INDICATES DEVICE CANDELA SETTING POTTER CHS-24x DEEP SINGLE GANG OR DOUBLE GANG E❑L END OF LINE DEVICE CHANC T SCOPE OF WORK: SUBMIT RELOCATE 2EA HORN/STROBES, ADD 1EA BOOSTER POWER SUPPLY, 2EA HORN/STROBES, 9EA STROBES TO THE EXISTING FIRE ALARM SYSTEM FOR THIS TENANT IMPR❑VEMENT AREA WIRE LEGEND A = 18-2 FPLP ADDRESSABLE INITIATING CKT B = 18-2 X 2 FPLP ADDRESSABLE INITIATING CKT LOOP C = 14-2 FPLP INDICATING CKT D = 14-2 X 2 FPLP INDICATING CKT LOOP E = 18-2 FPLP CONVENTIONAL INITIATING CKT F = 18-2 X 2 FPLP CONVENTIONAL INITIATING CKT LOOP G = 14-2 FPLP 24VDC POWER CKT H = 18-4 FPLP P-LINK CKT I = J = 18-4 FPLP ANNUNCIATOR CKT K = 18-2 FPLP CONTROL CKT L = 18-4 FPLP REMOTE TEST STATION CKT EXISTING RISER DIAGRAM NTS S7-1 S7-2 S7-3 S7-4 S7-5 15 TO DEDICATED 120VAC 15 " '15 30 FIRE ALARM FLOOR PLAN SCALE: 1/8"=1'-0" NEW WORK THIS SUBMITTAL S7-6 S7-7 S7-8 S7-9 30 75 " ' 15 " ' 15 15 w � w ❑ 2 ❑ � � Y D O U) ¢� � 2 r CQ SEQUENCE OF OPERATIONS z m o 0 w ❑ 0 J U J p= 7 w p > w I w o CO 0 m ❑ D LIJ U' w ❑ a 0 0 Y 00 w U J Q w Q 0 w i � 2 U] ❑¢� J } Q < z 7 w w w w 0- Cn 2 co LU 2 ❑ ❑ ❑ � ❑ ACTIVATION OF LOCAL ALARM AT FACP X X x X X X X INDICATION OF ALARM AT LCD ANNUNCIATOR X X X X X X X ACTIVATE ALL AUDIBLE & VISIBLE DEVICES x x x x x x x SHUT DOWN RESPECTIVE HVAC UNIT x INITIATE ELEV. RECALL TO MAIN FLOOR x INITIATE ELEV. RECALL TO ALTERNATE FLOOR X X X RELEASE DOOR HOLDERS x X x X x X X x CLOSE FIRE SMOKE DAMPERS X X X X X X X x TRANSMIT ALARM SIGNAL TO CENTRAL STATION x X X X X X X TROUBLE/SUPV- INDICATION AT FACP }( X X X X X TROUBLE/SUPV. INDICATION AT LCD ANNUNCIATOR X 171 X X x X X TRANSMITTROUBLE/SUPV. SIGNAL TO CENTRAL STATION X X I X I X X X S7-10 S7-11 S7-12 S7-13 C C 1.181 AMP C EOL 18.320 EOL 15 15 15 15 VOLTAGE --LOW ONE FLOOR BELO"IA i I: -PI T6-4fA tM f iiulrimidl WAY, rdii Mm WA 74170 114�&CIL VitLAQL HILLW'DO G Approved by Fire 07/23/2021 AFM fk--/F�tterer Subject to field inspection and approval City Of Edmonds Building Department Work FIRE ALARM MODIFICATION Address 10032 EDMONDS WAY Owner THRIVE DENTISTRY Approved Date Building Official Permit Number F I R2021-0072 0 It 5 I r 44;}ifM I N IFr� IN r � ,r 5 r �JwWNP ' • �I 5' RMJrk1W a � r RUIlimigmi Al,ti■lil N A 'tt SITE MAP N SCALE: NTS .4#l1] 1W Froula Alarm Systems, Inc 861 Industry Drive Tukwila, WA 98188 206-575-1962 m HOWARD E. WILLIAMSON Se r E�gi�ee Ta iaan, L—I ry Eire — Sr:tem: NICET C ,tfcatiosn[N.umber: 82289 Authoring Signature: ~ N W � � J W H a 0 � �o M wCC) W H W z H c�na�0 z �z � w F-4 a aw�� J � W 0 cr W (n H H zo LL � W 0 2 N W U M O � O Q T o RECEIVED Jul 14 2021 Ln V" CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ln Q Q w Q M PROJ. MGR.: Andrew Earle DRAFTER: HEW FA-1 SHEET NO. 1 OF 1