APPROVED BLD PLN BLD2021-1242+MECH & SITE PLANS+9.7.2021_10.56.58_AM+2395006ABBREVIATIONS GENERAL -LEGEND � DIAMETER RTU EQUIPMENT TAG TYPE ABV ABOVE 2 EQUIPMENT TAG NUMBER ACH AIR CHANGES PER HOUR AD ACCESS DOOR 1 DETAIL OR DIAGRAM NUMBER AFF ABOVE FINISHED FLOOR M2.1 SHEET NUMBER WHERE DETAIL SHOWN AFG AVERAGE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY 1 SECTION LETTER AHU AIR HANDLING UNIT M2.1 SHEET NUMBER WHERE SECTION SHOWN AHRI AIR CONDITIONING, HEATING REFRIGERATION INSTITUTE AP ACCESS PANEL � � REVISION CLOUD AND CHRONOLOGICAL NUMBER ARI AMERICAN REFRIGERATION INSTITUTE BHP BRAKE HORSEPOWER DETAIL REFERENCE OUTLINE BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT � POINT OF CONNECTION TO EXISTING OR TO BF BELOW FLOOR OTHERS' WORK BOT BOTTOM BTU(H) BRITISH THERMAL UNIT (HOUR) O KEY NOTE CALLOUT CD CONDENSATE CFM CUBIC FEET PER MINUTE 1Q PHOTO ID CALLOUT CONN CONNECTION COP COEFFICIENT OF PERFORMANCE WORK TO BE REMOVED DB DRY BULB/DECIBELS HVAC - L E G E N D DIBFF D FFIERENTIAL DN DOWN DR DRAIN �► AIR FLOW DIRECTION E EXISTING EA EACH OR EXHAUST AIR SUPPLY OR OSA DUCT SECTION UP, ROUND OR EAT ENTERING AIR TEMPERATURE � � RECTANGULAR EC ELECTRICAL CONTRACTOR EER ENERGY EFFICIENCY RATIO RETURN, RELIEF OR EXHAUST DUCT SECTION UP, EF EXHAUST FAN � � ROUND OR RECTANGULAR EFF EFFICIENCY EG ELEV EXHAUST GRILLE ELEVATION � � SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR EQUIP EQUIPMENT ESP EXH EXTERNAL STATIC PRESSURE EXHAUST � � RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR EXIST EXISTING F FURNACE EXISTING DUCTWORK °F FAHRENHEIT FF FINISHED FLOOR SLSM SOUND LINED SHEET METAL FLA FULL LOAD AMPERAGE FPM FEET PER MINUTE � FC FLEXIBLE EQUIPMENT CONNECTION FREQ FREQUENCY FT FOOT OR FEET SFD COMBINATION FIRE AND SMOKE DAMPER G NATURAL GAS HP HORSEPOWER OR HEAT PUMP FD FIRE DAMPER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR SD SMOKE DAMPER HT HEIGHT HVAC HEATING, VENTILATING, AIR-CONDITIONING EVADE VOLUME DAMPER HZ HERTZ IBC INTERNATIONAL BUILDING CODE M MD MOTORIZED DAMPER ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IFC INTERNATIONAL FIRE CODE � TURNING VANES IFGC INTERNATIONAL FUEL GAS CODE IMC INTERNATIONAL MECHANICAL CODE IN INCHES ROUND TO ROUND 45° FITTING IN WG INCHES WATER GAUGE KW KILOWATT LAT LEAVING AIR TEMPERATURE/LATITUDE SQUARE TO SQUARE 45° FITTING LBS POUNDS LIN FT LINEAR FOOT OR FEET LRA LOCKED ROTOR AMPS SQUARE TO ROUND 45° FITTING MAX MAXIMUM MBH 1,000 BTU PER HOUR MCA MINIMUM CURRENT AMPS VD 45° FITTING FOR DUCTWORK MFR MANUFACTURER MIN MINIMUM GAS PIPING MOCP MAX OVER CURRENT PROTECTION NEC NATIONAL ELECTRICAL CODE Oc CARBON MONOXIDE SENSOR NIC NOT IN CONTRACT NOM NOMINAL COORDINATED POWER LOCATION PROJECT DESCRIPTION THE PROJECT IS A LIKE -FOR -LIKE, ONE (1) SPLIT SYSTEM HEAT PUMP REPLACEMENT FOR A RESIDENTIAL SPACE, WITHIN ATHREE-STORY ASSISTED LIVING BUILDING. THE BUILDING IS SITED WITHIN THE CITY OF EDMONDS (JURISDICTION), SNOHOMISH COUNTY, WASHINGTON. MECHANICAL PERMIT: UNDER APPLICATION RELATED ELECTRICAL PERMIT: UNDER SEPARATE PERMIT GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE INSTALLED BY AN LICENSED COMMERCIAL ELECTRICIAN. 4. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2015 WSEC, IBC AND IMC. 5. ALL RIGGING AND LIFTING TO BE COORDINATED WITH THE BUILDING OWNERSHIP AND ANY OTHER CITY AND LOCAL JURISDICTIONS. APPLICABLE CODES 1. 2018 WASHINGTON STATE ENERGY CODE (WAC) CHAPTER 51-11) 2. 2018 INTERNATIONAL BUILDING CODE (WAC CHAPTER 51-50) 3. 2018 INTERNATIONAL MECHANICAL CODE (WAC CHAPTER 51-52) 4. 2018 INTERNATIONAL FUEL GAS CODE (WAC CHAPTER 51-52) 5. 2018 UNIFORM PLUMBING CODE (WAC CHAPTER 51-56) 6. NATIONAL ELECTRICAL CODE (NFPA 70 -WAC CHAPTER 296-46B) CODE COMPLIANCE NOTES 1. PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF PROVIDING 5 DEGREE DEAD BAND AS REQUIRED BY 2018 WSEC SECTION C403.2.4.1.2. CONTROLS SHALL ALSO BE CAPABLE OF PROVIDING SEVEN DAY PROGRAMMABLE TEMPERATURE SETTINGS, AUTOMATIC SETBACK AND SHUTOFF AND OPTIMUM START AS REQUIRED BY 2018 WSEC SECTION C403.2.4.2 (OFF -HOUR CONTROLS). CONTROLS SHALL BE CONFIGURED TO PREVENT SIMULTANEOUS HEATING AND COOLING. 2. REPLACEMENT SPLIT SYSTEM AIR CONDITIONER IS OF THE SAME TYPE AND OUTPUT CAPACITY. 3. THIS PROJECT MEETS THE 2018 WSEC MINIMUM EFFICIENCY REQUIREMENTS FOR COOLING PROVIDED BY ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS PER TABLE C403.2.3(2)A WITH A EER OF 12.2, WHICH MATCHES THE MINIMUM REQUIREMENT OF 11.2 EER FOR EQUIPMENT SIZE CATEGORY <65 MBH (UNITARY AIR CONDITIONERS, SPLIT SYSTEM). MECHANICAL SCOPE THE PROJECT IS FOR THE REPLACEMENT OF ONE (1) EXISTING SPLIT SYSTEM HEAT PUMP HVAC UNIT. THE EXISTING SYSTEM HAS REACHED THE END OF IT'S USEFUL LIFE. THE NEW SYSTEM IS THE SAME TYPE AND SAME NOMINAL OUTPUT CAPACITY: 1. DEMO THE (1) OAC-1 EXISTING ROOFTOP HVAC UNIT &FAN COIL SERVING THE RESIDENTIAL SPACE. 2. THE REMOVAL AND DISPOSAL OF THE EXISTING UNITS FROM BUILDING SHALL BE IN A LAWFUL MANNER. RECLAIM EXISTING REFRIGERANT PER EPA STANDARDS; R-22 IS EXISTING REFRIGERANT PER EQUIPMENT NAME PLATE DATA. 3. PROVIDE AND INSTALL ONE (1) ROOFTOP OAC UNIT 8c (1) IAC IN PLACE OF THE EXISTING UNITS PER PLAN. NEW EQUIPMENT INCLUDES ELECTRIC DX COOLING &BASIC ELECTRO-MECHANICAL CONTROLS. 4. DISCONNECT AND RE -CONNECT REPLACEMENT IAC 8c OAC TO EXISTING ELECTRICAL SERVICES. RE -USE EXISTING ELECTRICAL DISCONNECT WHERE PRACTICABLE. LINE VOLTAGE WORK SHALL BE BY LICENSED COMMERCIAL ELECTRICIAN (UNDER SEPARATE PERMIT). 5. REUSE EXISTING THERMOSTAT AND CONTROL WIRING. OD OUTSIDE DIAMETER/DIMENSION U vvV�•V������V � V����\ �vv���v" 6. EQUIPMENT AND SYSTEM START-UP, TEST AND BALANCE, PROGRAMMING AND OWNER OPTS OPTIONS O REMOTE SENSOR TRAINING FOR NEW EQUIPMENT, 0&M MANUALS AND RECORD DRAWINGS. OSA OUTSIDE AIR PH ELEC POWER PHASE (14 OR 3�) O THERMOSTAT A P P R V E��CHANICALNEQU ALL OF THE PN PROJECT NORTH (REFERENCE) PMENT ON THE ROOF.INOESCREENING ISANEC SSARYNDING POC PRESS POINT OF CONNECTION PRESSURE COMMISSIONING PLANS MUST BE PSI POUNDS PER SQUARE INCH .,. .,�r��.,.� .�., ,.., .,����� .�„ n �r�� � n w ��� n � �vr+Tr� �� RA RD RETURN AIR OR RELIEF AIR ROOF DRAIN MECHANICAL SYSTE M B REF REFERENCE COPIES OF ALL APPLICABLE SERVICE AND EQUIPMENT DATA, AS WELL AS RPM REVOLUTIONS PER MINUTE PROJECT DOCUMENTATION THAT RELATES, SHALL BE PROVIDED TO THE RTU ROOFTOP UNIT OWNER AND MADE AVAILABLE TO THE AUTHORITY SA SUPPLY AIR WITHIN 90 DAYS OF PROJECT COMPLETION AND IN ACCORDANCE WITH 2O15 WSEC SECTION C408.1, INCLUDING: ALL WORK SUBJECT SEER SUPPOYAFANNORGSQUAREI FO T ORIO EET SMACNA SHEET METAL NATIONAL ASSOCIATION 1. PRELIMINARY COMMISSIONING REPORT AND OT R RELATED REFTO� FIELD T TON (1 TON = 12,000 BTUH) SUCH AS AIR BALANCING, START-UP AND/OR RESS E D T TN TRUE NORTH (REFERENCE) ��I��I���ION FOR T-STAY THERMOSTAT 2. RECORD DRAWINGS DEPICTING FINAL INSTALLA N I 0 TYP TYPICAL SYSTEMS AND EQUIPMENT. ���� �� M P LIAN C E ULL ULTRA LOW LEAK DAMPER UNO UNLESS NOTED OTHERWISE 3. OPERATION AND MAINTENANCE EQUIPMENT MA UPC UNIFORM PLUMBING CODE MANUFACTURER'S INFORMATION WITH SPECIFIC MODEL NUMBERS AND W WATTS/WIDTH/WINDOW OPTIONS NOTED, CONTROLS DATA INCLUDING CALIBRATION AND SET WB WET BULB POINT INFORMATION, AND A SIMPLE NARRATIVE DESCRIPTION OF EACH WSEC WASHINGTON STATE ENERGY CODE SYSTEM. COPYRIGHT 2021 PINEHURST ENGINEERING, PLLC City Of Edmonds Building Department Work ; MECHANICAL Address 750 EDMONDS WAY Owner SUNRISE OF EDMONDS Approved Date ; 09/16/2021 Building Official E1riri � Permit Number BLD2021-1242 \�� 1 _ � 1\� �T Y 1\/1 0 F� !nv �nn�l r ►�nnc� nlnT Tn c,nnl r\ nnn IrnT I nnnTlnnl �Gn rn►�nnmc� �ninv rn►�nnlnc, SITE MAP (BY GOOGLE MAPS, NOT TO SCALE) r l\VULV I LVI�/'11 IVIV - l l � I\VVI I Vr VIVI I I V UL I\Lr U'1l�LU BUILDING INFORMATION LEGAL DESCRIPTION PROJECT ADDRESS: SUNRISE OF EDMONDS 750 EDMONDS WAY, EDMONDS, WA. 98020-5126 SITE CONTACT: RICHARD (425) 673-9700 PROPERTY OWNER: HCP SUN1 EDMONDS WA LLC., 2235 FARADAY AVE, SUITE �0, CARLSBAD, CA. 92009 TAX PARCEL NUMBER: 27032500306200 CONSTRUCTION TYPES: 11 - 1 HR FULLY SPRINKLERED :�I�/_1:i'��ZK�111�_1�[yI�.�K�1�1%1��.Yy��lty���1�:� ORIGINAL CONSTRUCT: 2004 TOTAL BUILDING AREA: 60,052 SF CLIMATE ZONE: 4C-SNOHOMISH THIS ASSISTED LIVING RESIDENTIAL PROPERTY HAS A SINGLE INSTUTUTIONAL RELATED OCCUPANCY AND BUILDING IDENTIFICATION ASSOCIATED WITH IT. ADDITIONAL PROPERTY AND BUILDING DATA CAN BE FOUND FROM THE CITY OF EDMONDS AND SNOHOMISH COUNTY ASSESSORS MAPS. DRAWING INDEX PAGE � SHEET � SHEET TITLE SCALE 1 M0.1 COVER SHEET, LEGEND AND NOTES N/A 2 M0.2 EQUIPMENT SCHEDULES N/A 3 M0.3 NEW EQUIPMENT DATA SHEETS N/A 4 M0.4 NEW EQUIPMENT DATA SHEETS N/A 5 M1.1 ROOF PLAN -MECHANICAL 1/8" = 1'-0" SEC 25 TWP 27 RGE 03 TH PTN SW1/4 SE1 /4 SW1 /4 DAF: BEG SW COR SD SUB;TH N01 *00 36E ALG W LN 60.6FT TH N60*11 41 E 358.30 FT TO SWLY MGN OF SR-104 (EDMONDS WAY) AS CONVD PER DEED REC AF2180193; THS39*05 51 E PLW & 40FT SWLY C/L SR-104 ALG SWLY MGN AS CONVD TO ST OF WA BY DEEDS REC AFN'S 2180193, 2181901 8c 2185476 DIST OF 201.69FT TAP OPST HWY ENGR STA 97+85; TH S01 *05 34W ALG SD MGN DIST OF46.49FT TAP 30FT NWLY & OPST HES 0-70; TH N88*29 44W DIST OF 382.17FT TO POB; PER CITY OF EDM LL-2000-134 REC AFN200303175004 APPROVED BY PLANNING �� ��� Sep 22 2021 0 4' 8' 16' `� SCALE: 1/8" = 1'-0" w �� �� N O az �o� �N a z , �_� wQ °O � � � GV � U J � p W � = L1J LL 3 o0 z m CV 0 ti O� � O Z 0 U LJJ m� J = CV � � � �o oN �� o� w Z � U � J O �� U �°�o 000�°v-9-0'121 EXPIRES: 10/25/22 0 Q Q o w 3 °` O�¢ Wo3 z �oQ boo w� �oQ 0 RECEIVED Sep 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M0.1 COVER SHEET LEGEND AND NOTES PROJECT NO. Q2Q-Q34 9/2/21 IAC-1 EMR OAC-1 EMR ,� 1R C O IVD 1 T1 a 111ER EQUIP NO. SERVICE AIRFLOW, CFM ESP, IN WC COIL CONFGURATION COOLING CAPACITY, TO N5 ELECTRICAL DATA WEIGHT, LBS BASIS OF DESIGN VOLTAGE MGA MOCP IA.C-1 ELEV MACH RM 775 0.5 HORIZONTAL 2 230V11P 1 25 5D MITSUBISHI PKA-A24KA7 cOw��ws�R EQUIP NO. SERVICE CONNECTED INDOOR UNIT NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH EER ELECTRICAL DATA SOUND PRESSURE, DBA WEIGHT, LBS BASIS OF DESIGN (1} (2} (3} (4} VOLTAGE MCA MOCP OAG-1 ELEV MACH RM IAC-1 2 24,400 12 230V11P 19 25 47 160 MITSUBISHI PUY-A24NHA7 NOTES: (1 } ARI LISTED WITH STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION, FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURERES RECCOMENDATIONS. (2} WITH FACTORY OPTION DISCONNECT. (3} PROVIDE ALL REQUIRED ACCESSORIES FOR LONG -LINE AND LOW -AMBIENT APPLICATIONS. (4} ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING. GENERAL NOTES DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW ROOFTOP OAC UNIT &IAC ARE REPLACING THE SAME TYPE AND CAPACITY OAC UNIT 8c IAC IN THE SAME LOCATIONS, UTILIZING EXISTING POWER SUPPLY AND DUCTWORK. 0 4' 8' 16' `� SCALE: 1/8" = 1'-0" O U H v� W m J = CV � oho �' � 0 � Q LL (n � � � � U � . W L.L.I � � r� Z � W (n U_ � J O Q � 0 U V'" "V �QN F WAS C Mq� . , O _ /yin. ��, i G "°oao 000°" 9-0�-21 ExP�RES: 10/25/22 N O 00 Q z 0 Q w 0 RECEIVED Sep 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M0.2 EQUIPMENT SCHEDULES PROJECT NO. 02Q-Q34 COPIRIGHT 2021 PINEHURST ENGINEERING, PLLC Job Name: System Reference: Date: IndoorUnit............................................................................ PKA-A24KA7 Outdoor Unit ° Standard Model,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, PUY-A24NHA7 ° Seacoast Model PUY-A24NHA7-BS �' - ' laolllllllllllllllllllllllllolk, dlllllllllllllllllllllllllllllllllllllllllll IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII. I I �illlllllllllllllllllllllllllllllii����P I III Ill�iiiiiiilll000ll°" hl I t ,. INDOOR UNIT FEATURES • Sleek, compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more • Multiple control options available: o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • Power receiver pre -charged with refrigerant volume for piping length up to 70 ft • Low ambient cooling down to -40°F providing 100%capacity (only for PUY models with wind baffles installed) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers • Superior energy and operational efficiency Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REPLACEMENT EQUIPMENT DATA SHEETS Cooling at 95°F' Efficiency Electrical Indoor Unit IAC-1 EMR Indoor Unit Operating Temperature Range Outdoor Unit OAC-1 EMR Outdoor Unit Operating Temperature Range Refrigerant Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal Sensible Heat Factor Power Factor _ SEER EER' �ERGY STAR® Certified Voltage, Phase, Frequency Guaranteed Voltage Range Voltage: Indoor -Outdoor, S1-S2 Voltage: Indoor -Outdoor, S2-S3 Short-circuit Current Rating [SCCR] Recommended Fuse/Breaker Size (Oudoor) Recommended Wire Size [Indoor -Outdoor] Power Supply MCA Fan Motor Full Load Amperage Fan Motor Output Fan Motor Type Airflow Rate at Cooling, Dry Airflow Rate at Cooling, Wet Sound Pressure Level [Cooling] Drain Pipe Size Coating on Heat Exchanger External Finish Color Unit Dimensions Package Dimensions Unit Weight Package Weight Cooling Intake Air Temp [Maximum /Minimum]' Heating Intake Air Temp [Maximum /Minimum] MCA MOCP i Fan Motor Full Load Amperage Fan Motor Output Airfow Rate Refrigerant Control Defrost Method Coating on Heat Exchanger Sound Pressure Level, Coaling' Compressor Type Compressor Model Compressor Rated Load Amps Compressor Locked Rotor Amps Compressor Oil Type //Charge External Finish Color Base Pan Heater Unit Dimensions Package Dimensions unit Cooling Air Temp [Maximum /Minimum]` Additional Refrigerant Charge PerAdditional BTU/H BTU/H BTU/H W W Pintslh Viz VAC VAC V DC kA A AWG A A w CFM CFM dB[A] In. [mm] WxDxH:ln. WxDxH:ln. Lbs. [kg] Lbs. [kg] °F °F A A A W CFM A A oz. WxDxH:ln. WxDxH:ln. Lbs. [kg] Lbs. [kg] °F Lbs, oz Ft. [m] oz./Ft. [g/r 24,000 24,000 10,000 1,sso 1,960 5.0 0.77 95.7/95.7 21.4 12.2 No 208/230, 1, 60 198 - 253 208/230 24 5 14 Indoor unit is powered by the outdoor unit _1.0 0.36 56 DC Motor 635-705-775 570�35-700 39�2-45 5/8 [16] White Munsell 1.OY 9.2/0.2 46-1/16 x 11-5/8 x 14-3/8 [1170 x 295 x 365 51 x 14-1/4 x 18-1/2 [1295 x 362 x 470] 46 [21 ] 53 [24] I 90 DB, 72 WB / 66 DB, 61 WB 77 DB / 59 DB 1s.o I 2s 0.4 LEV Reverse Cycle Blue Fin Coating (BS Model only) 47 INVERTER -driven twin rotary SN6172FWHM1 7.0 11.0 FVSOS // 23 Ivory Munsell 3Y 7.8/1.1 N/A 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 10: 151 [68] 176 [80] 115 DB / -40 DB R410A 7, 11.0 70.0 [20.0] 0.3 [22.5] NOTES: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 'Cooling (Indoor //Outdoor) °F 80 DB, 67 WB // 95 OB, 75 WB 'Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum /Minimum)): •Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. » Wind baffles required to operate below 23°F DB in cooling mode. » Cooling -only system with advanced wind baffle: -40°F-115°F. » Refer to wind baffle documentation for further information. "Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lockout / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (-BS MODELS) • External Outer Panel: Phosphate coating +Acrylic -Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. I Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] I In.[mm] 3/8 [9.52] Piping Maximum Piping Length Ft. [m] 225 [68] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 'Cooling (Indoor //Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 'Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum /Minimum)): •Applications should be restricted tc comfort ccoling only; equipment cooling applications are not recommended for low ambient temperature conditions. » Wind baffles required to operate below 23°F DB in cooling mode. » Cooling -only system with advanced wind baffle: -40°F-115°F. » Refer to wind baffle documentation for further information. "Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (-BS MODELS) • External Outer Panel: Phosphate coating +Acrylio-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW ROOFTOP OAC UNIT &IAC ARE REPLACING THE SAME TYPE AND CAPACITY EQUIPMENT IN THE SAME LOCATIONS, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. 0 4' 8' 16' `If✓ SCALE: 1/8" = 1'-0" O U H v� W lY] J = CV � oho �' � � � Q Ll_ N U � W � � � Z � W (n U_ � J O Q � 0 U OQNER" T � � � Mqv ..,�oFWASyi,��:�;��. G G o��OFFSS�ONAL. ��G��ooOo ��0000000 9-0� 21 ExPIRES: 10/25/22 0 N 00 ¢' Q z 0 Q w 0 RECEIVED Sep 07 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NO. M0.3 NEW EQUIPMENT DATA SHEETS PROJECT NO. Q2Q-Q34 COPYRIGHT 2021 PINEHURST ENGINEERING, PLLC 9/2/21 Len slee mriw�rthob rti.p�e 2-29/3: A t-3/1 30 1J/8(35) 2-79132 66 Under sine C VanB(allo) Lave m nual s a s Knopwm ride forbwer piping Piping connection Sleeve (purchased locally) Through hole [ 2-15/i6 [ 2-15/16—[ 3-5/32 ([ 75) ([ 75-[ 80) Unit: inch (mm) Rphl s'de t Liquid pipe Refrigerant pipe: 3I8 O.D([ 9.52) Flared connection: 3/8F 2 Gas pipe Refigerant pipe: 5/8 O.D([ 15.88) Flared connection: 5I8F 3 Drain hose 5/8([ 16) O.D Effective length: 23-1/32 (585) Reouired space(Indoor unit) Air inlet C N of \ Alr OUtiet Min.&21/32(220) Min.331/32(100.5) 2-911 65 Center measurement 1pla [ 3r32([ 25) 0.[1,nz091em nob .� _ — rewm hwm ��8� � _ _e a �%�^A�_ r�3•,Rt s,l a "��� � �� � �� ���a�m manor mmn oanir _ _. _ .. - Specifications are subject to change without notice. r � � a r � " n \ r�� a � � � �' " '—^ � iwaa,n non: r« re�pipire wen has m. ,z-srirysmsl ,z-vwanl Knockout hole far piping B 3-711fi(87) 73/32(10.7) © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1 FREE SPACE (Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4PlPING-WIRING DIRECTIONS The diagram below shows a Dimensions of space needed Please secure the unit fnnly Piping and wiring connections basic example. for service aceess are wdh 4 foundation (M10<W3I8>) bolts. can be made from 4 directions: Explantion of paNwlar details are shown in the below diagrem. (Botts and washers must be FRDNT,Right,Rear and Below. given in the installation manuals etc. purchased locally.) �® � <Foundation bolt height> Side Air h10 <13> � FOUNDATION j 9eNiae � o � ' s ace Min. � �<, 500 <i9-t1/ifi> � �8 Example of Notes 8- Refrigerant GAS pipe wnneciion (FLARE) m15.88i5 2 ���Re(rigemm LIQUID pipe connecgon(FLARE) 09.52( •i... Indication of STOP VALVE connection location. Piping knockout Hole Details I PawersgppPywinng hde Rpht oioiiw hole OAC-1 EMR Unit: mm<in> nRear Air Intake ,.. , u m �� ., , - ,^-- _ ��--g n� .� 11114 I d ��tai�yl ��... FORM# PKA-A24KA7.TH & PUY-A24NHA7(-BS) - 202107 Specifications are subject to change without notice. REPLACEMENT EQUIPMENT DATA SHEETS 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Eta G9 Intertek © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. GENERAL NOTES DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW ROOFTOP OAC 8c IAC UNITS ARE REPLACING THE SAME TYPE AND CAPACITY IN THE SAME LOCATIONS, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. 0 4' 8' 16' `� SCALE: 1/8" = 1'-0" O U H t!� W m J = CV � � � � � � Q L.L (/� � � � N U � - W L.LJ � � � Z � W Cn _U � J O Q L.L U O N MO �W V 1 a 3 Q z 0 Q w ED '.1 ICES =NT -s 034 COPYRIGHT 2021 PINEHURST ENGINEERING, PLLC 9/2/21 r" ROOF PLAN -MECHANICAL � SCALE: 1/8" = 1'-0„ GENERAL NOTES 1. DRAWINGS FOR MECHANICAL WORK WITHIN THE EXISTING BUILDING SPACE AND ROOFTOP ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. THE ACCURACY AND COMPLETENESS OF THE DESIGN CONTENT REQUIRES FIELD VERIFICATION FOR ALL LOCATIONS AND DIMENSIONS PRIOR TO START OF MECHANICAL WORK. 2. MECHANICAL SCOPE OF WORK BOUNDED BY BUILDING EXTERIOR WALLS AND ROOF, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE PARALLEL AND PERPENDICULAR TO BUILDING COLUMN LINES. 3. THE NEW ROOFTOP HVAC UNIT IS REPLACING THE SAME TYPE AND CAPACITY HP & FCU IN THE SAME LOCATIONS, UTILIZING EXISTING DUCTWORK AND POWER SUPPLY. PLAN NOTES O1 STAGING OF EQUIPMENT AND CRANE LOCATIONS TO BE COORDINATED AND APPROVED PRIOR TO CONSTRUCTION. O2 NEW UNIT SHALL BE INSTALLED IN SAME LOCATION AS EXISTING O3 EXISTING ROOFTOP HVAC EQUIPMENT NOT IN SCOPE OF WORK (EXISTING TO REMAIN). ® NEW OAC-1 REPLACEMENT 2-TON UNIT IS THE SAME TYPE AND OUTPUT CAPACITY AS EXISTING. NO NEW ROOF PENETRATIONS ARE REQUIRED FOR THIS WORK. RE -USE THE EXISTING ELECTRICAL DISCONNECT SWITCH AS APPLICABLE. RE -USE EXISTING CONTROL WIRING. IAC-1 INDOOR UNIT LOCATED IN ELEVATOR MACHINE ROOM IN BASEMENT. 0 4' 8' 16' `� SCALE: 1/8" = 1'-0" 9/2/21 0 U H rn w m � J = CV � � � �o oQ �N �� o� U � . w �� w ci U � J O �� 0 U N O 00 a 3 Q z 0 Q w ED '.1 ICES �L �34 COPIRIGHT 2021 PINEHURST ENGINEERING, PLLC