REVIEWED BLD BLD2021-0190+Structural_Analysis_or_Calculations+1.31.2021_5.34.30_PM+2025080RECEIVED Swenson Say Faget Feb 02 2021 STRUCTURAL ENGINEERING CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2124 Third Ave, Suite 100 Seattle, WA 98121 O 206.443.6212 934 Broadway, Suite 100 Tacoma, WA 98402 O 253.284.9470 BLD2021-0190 � ssfengineers.com Memorandum To: Karim Khoury Date: Address: 1113 Juniper Beach Road From: Camano Island, WA 98282 Project: 21302 93Id PI. W. Edmonds 12665-2021-01 Structural Recommendations January 27, 2021 REVIEWED BY Ryan Anderson, PE, SE CITY OF EDMONDS SSF Engineers completed on -site structural observation of the existing roof framing at 21302 93" PI W. in Edmonds, Washington. We understand that several interior walls (indicated with dashed lines in the attached partial roof framing plan) are proposed to be removed as part of the renovation. The existing roof framing consists primarily of premanufactured roof trusses spanning east -to -west from exterior wall to exterior wall. Where the orientation of the trusses changes to accommodate the skew in plan the roof is stick framed with rafters and ceiling joists. The rafters frame into short spanning ridge beams that are supported by full span girder trusses as indicated on the plan. The ceiling joists in this area appear to splice above the interior walls below. In these locations, we recommend supporting the existing ceiling joists up to the existing rafter above with a 2x6 each side of each splice location per SSK-2 (attached). Upon completion of the proposed ceiling joist reinforcing, the interior walls below may be removed. All existing framing shall be field verified by the contractor prior to demolition. The contractor shall notify the structural engineer if existing conditions determined during work vary from the existing construction shown on the drawing. Ryan Anderson, PE, SE rnderson@ssfengineers.com (E) PREMANUFACTURED ROOF TRUSS @ 24"oc TYP UNO EXISTING INTERIOR WALLS TO BE REMOVED ' i (E) RIDGE (E) GIRDER TRU06 SS �i G1RpER TRUSS ® � � ,I,, PROVIDE 2x6 VERTICAL EA ' CEILING JOIST EA SIDE OF EA SPLICE LOCATION TO RAFTER ABOVE PER SSK-2 Partial Roof FraMng Ran T s°=T -o° 'RUCTURAL IGINEERING 2124 Third Avenue - Suite loo - Seattle, WA 98121 p:2o6.443.6212 ssfengineers.com Project Title: 21302 93rd PI. W. Edmonds Sheet Title: Partial Roof Framing Plan Date SSF project no. 01/27/21 12665-2021-01 Design RJA Drawn Sheet RJA SSK-1 LS7O RAFTI RIDGE AT SUPPORTIN JOIST (E) RAFTEF (E) RIDGE (E) CEILINV Qdi l l SPLICING OVER (E) INTERIOR WALL 'RUCTURAL IGINEERING (3) 0.22" 0 SDWS SCREW VERTICAL 2x6 TO (E) CEILING JOIST AND RAFTER. PROVIDE SOLID BLOCKING AS REQD FOR ALIGNMENT AND PROVIDE SCREWS w/ FULL PENETRATION INTO JOIST AND RAFTER PROVIDE 2x6 VERTICAL SUPPORT EA SIDE OF CEILING JOIST SPLICE TO RAFTER ABOVE. W --INTERIOR WALL TO BE REMOVED Project Title: Date 21302 93rd PI. W. Edmonds 01/27/21 Sheet Title: Ceiling Joist Reinforcing Design RJA SSF project no. 12665-2021-01 Drawn Sheet RJA SSK-2 2124 Third Avenue - Suite loo - Seattle, WA 98121 p:2o6.443.6212 ssfengineers.conn