APPROVED BLD BLD2021-1186+Mechanical_Plan+8.25.2021_12.53.43_PM+2375751
ABBREVIATIONS 0 DIAMETER MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL AFF ABOVE FINISHED FLOOR MIN MINIMUM AHU AIR HANDLING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION BHP BRAKE HORSEPOWER NC NOISE CRITERIA BDD BACKDRAFT DAMPER NOM NOMINAL BPD BY-PASS DAMPER NO. NUMBER BTU/H BRITISH THERMAL UNIT PER HOUR NTS NOT TO SCALE C CONDENSATE DRAIN PIPING CD CEILING DIFFUSER OA OUTSIDE AIR CFM CUBIC FEET PER MINUTE OBD OPPOSED BLADE DAMPER ODD OUTSIDE DIMENSION OF DIAMETER DB DECIBAL OU OUTDOOR UNIT DH DUCT HEATER DOAS DEDICATED OUTDOOR AIR SYSTEM POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE R REFRIGERATION LINES ESP EXTERNAL STATIC PRESSURE RA RETURN AIR EXH EXHAUST RCP REFLECTED CEILING PLAN RG RETURN GRILLE FCU FAN COIL UNIT RPM REVOLUTIONS PER MINUTE FD FIRE DAMPER RTU ROOFTOP UNIT FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER SD SUPPLY DIFFUSER SL SOUND LINED GF GAS FURNACE SP STATIC PRESSURE GRID GRILLE, REGISTER, DIFFUSER SM/D SMOKE DAMPER HP HORSEPOWER, HEAT PUMP TG TRANSFER GRILLE HRU HEAT RECOVERY UNIT T'STAT THERMOSTAT HVAC HEATING VENTILATION & AIR CONDITIONING TYP TYPICAL ID INSIDE DIMENSION VAV VARIABLE AIR VOLUME IECC INTERNATIONAL ENERGY CONSERVATION CODE VFD VARIABLE FREQUENCY DRIVE IFR INFRARED HEATER VTR VENT TO ROOF IMC INTERNATIONAL MECHANICAL CODE IN INCH WSEC WASHINGTON STATE ENERGY CODE ISP INTERNAL STATIC PRESSURE ZD ZONE DAMPER LB POUND LVR LOUVER PLAN SYMBOLS GENERAL HVAC NOTES CEILING SUPPLY DIFFUSER 1. COMPLETE INSTALLATION OF MECHANICAL SYSTEMS CEILING RETURN GRILLE SHALL MEET APPLICABLE CODES PER 2018 IBC WITH WASHINGTON STATE AMENDMENTS, 2018 IMC WITH Z CEILING EXHAUST GRILLE WASHINGTON STATE AMENDMENTS, & 2018 IECC. nVw FLEX DUCT 2. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE CEILING EXHAUST FAN FOR INSPECTORS. 3. DUCT INSULATION AND SEALING TO MEET REQUIREMENTS INLINE EXHAUST FAN OF SEC C403.10.1 OF THE 2018 WSEC. (S) EXHAUST FAN UP 4. SYSTEM CONTROLS TO MEET ALL APPLICABLE SECTIONS C ROUND DUCT UP UNDER SEC C403.4 OF 2018 WSEC. 5. THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM ROUND DUCT DOWN DEADBAND OF 5OF PER WSEC C403.4.1.2. VAV FAN BOX 6. CONTROLS TO BE EQUIPPED WITH AUTOMATIC TIME BALANCE DAMPER (MANUAL) CLOCK CAPABLE OF STARTING AND STOPPING THE SYSTEM WITH MANUAL OVERRIDE PER WSEC C403.4.2.2 F� FIRE DAMPER 7, OUTDOOR AIR SUPPLY, EXHAUST OPENING, RELIEFS TO BE FSD FIRE SMOKE DAMPER PROVIDED WITH CLASS 1 MOTORIZED DAMPER AND CLOSE M MOTORIZED DAMPER DURING UNOCCUPIED EQUIPMENT OPERATION PER WSEC C403.7.8.1. IF GRAVITY DAMPER, IT SHALL HAVE AN AIR B ZONE DAMPER LEAKAGE RATE NOT GREATER THAN 20 CFM/FTA2. FIRE DAMPER ABOVE DIFFUSER 8, VENTILATION BY MECHANICAL OR NATURAL MEANS FIRE DAMPER ABOVE GRILLE SHALL BE NO GREATER THAN 150 PERCENT OF THE MINIMUM OA REQUIRED PER WSEC C403.2.2. OT THERMOSTAT b ALL ECONOMIZERS PROVIDED SHALL MEET SEC C403.5 OF OS SENSOR 2018 WSEC AND BE ABLE TO PROVIDE UP TO 100 PERCENT 0 GAS METER OSA FOR COOLING PER WSEC C403.5.3.1. 10. SMOKE DETECTORS INSTALLED IN MAIN RETURN PER SEC sM SMOKE DETECTOR 606 OF THE 2018 IMC. SD-# SUPPLY DIFFUSER 11. ALL HVAC EQUIPMENT TO BE LABELED FOR THE SPACE RG-# RETURN GRILLE SERVED. 12. DUCTS TO BE SUPPORTED AT EACH CHANGE IN EF-# EXHAUST FAN DIRECTION, VERTICAL AT 12'-0" MAX, HORIZONTAL AT 10'-0" TG-# TRANSFER GRILLE MAX WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT 13. ALL SUPPLY GRILLES TO HAVE MANUAL VOLUME DAMPERS - C - CONDENSATE LINE FOR BALANCING OF SYSTEM UPON COMPLETION. - R - PAIRED REFER LINES 14. ALL PIPING TO BE INSULATED ACCORDING TO SECTION C403.10.3 OF 2018 WSEC. 15. FRESH AIR INTAKE AND RELIEF/EXHAUST WILL BE EQUIPPED WITH A LOW LEAK, CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSES DURING UNOCCUPIED HOURS TO COMPLY WITH SEC C403.7.8.1 OF 2018 WSEC 16. GAS PIPING TO BE INSTALLED IN ACCORDANCE WITH THE 2018 IFGC TABLE C404.6 WHEN APPLICABLE. 17. All EQUIPMENT SPECIFIED THE SMALLEST SIZE THAT EXCEEDS THE CALCULATED LOADS PER WSEC C403.3.1. DIFFUSERS AND GRILLE SCHEDULE TAG Q TY MAKE MODEL SIZE NECK BORDER TYPE NOTES SD-1 1 SHOEMAKER 700MA - 8" LAY -IN R G -1 1 SHOEMAKER 600T 12X24 - LAY- I N APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 18. HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 IN 2018 WSEC HAVE BEEN SATISFIED, INCLUDING AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS, BALANCE REPORT, AND COMMISSIONING 6 REPORT. 1 . FLEXIBLE INSULATED DUCTS SHALL BE MAXIMUM 5'0" LONG AND STALL MEET INSTALLATION AND MATERIAL REQUIREMENTS OF LOCAL CODES. 20. ALL BRANCH TAKE -OFFS SHALL BE PROVIDED WITH MANUAL BALANCING DAMPERS. -, Banner Sank ///Q Etlmonda Cannabfs... © Q �claarwmer car w 2141n srsw 21ztns sw • � Swl ckaM TOYeta �r3ut f , Park 2l2Q r ,Q; t1p F � 219D] 72nd Avg YY, � - Edmonds, WA 96626 - Altlercrest Healxh Q - / • + &Rehab Center ©MCDorialtl'e QForeign Engines � Cat1 FAcura� �SRepaei r[ - n �Sahm Gpok Jih S€ac¢ �• � _ �� � Premera BI-CrossQ ' A VICINITY MAP 1 -b t WWIAR . i Iry - IMF :. F. A PROPERTY SITE N TENANT: THE EVERETT CLINIC LAND OWNER: HSRE EDMONDS MOB OWNER LLC 444 W LAKE ST STE 2100, CHICAGO, IL 60606 PARCEL NO. 00580700002208 LEGAL DESCRIPTION: 66 THE WEST 20 FEET OF LOT B AND ALL OF LOT C OKb CITY OF EDMONDS SHORT6PL T NO. S- 8-44, ACCORDING TO THE SHORT PLAT RECORDED SEPTEMBER 15,1 8 UNDER RECORDING NO. 80 50217, IN SNOHOMISH COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON ALL SUBJECT TO EASEMENTS, RESTRICTIONS AND RESERVATIONS OF RECORD. "NO -BUILD, LIGHT AND OPEN AIR EASEMENT", RECORDING NO. 201108080106. SITE AREA: 411.4 SF BUILDING AREA: 82,074 SF ZONING: CG-2 SCOPE OF WORK: 1. Relo cote 1 existin g su pply diffu ser. 66 2. Provide a n d in sto 11 1 n ew su pply diffu ser fo r ro o m #3 7. 3. Relo co te th e existin g exh a u st g rill a s n eeded to a(to wforthenewwoIt. 4. Pro vide a n d in sto 11 1 retu rn g rill. City Of Edmonds Building Department Work MECHANICAL Address 21401 72ND AVE W Owner THE EVERETT CLINIC Approved Date: OW66 2021 -------------------- Building Official -------------------------------- Permit Number BLD2021-1186 SHEET INDEX M0.0 COVER SHEET M1.0 HVAC MECHANICAL PLAN M2.0 SCHEDULES RECEIVED Aug 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z W O O z U O O U 06 Lo Z � X Q m = O U z U W 1-0 O > LLJ Q > w oU W N Z 0 O N LU a U) Z O U) LU CV co La -O I, o0 Z a O L 0 N O U) \ a J U (10 Q 00 LU T v z U a Z m Z < w < LLJ MO.0 //11 51$N J59---7 7`ll� 10" RG-11 12X24 811 L� BY / 301 / U 00 Y ROO 8, EF-1 (E 10" UP TO ROO 10"— � '-, EG-1 (E SD-19 8 11 SDLED PCK UP 156 CFM �l \ /� HVAC DESIGN SD- , 1011 (E RELOCATE i inr -roil T/--. nii r%rr--..i It.--rr ----------- Ir------- ----------- II II II II II II II I 357 MR v CO ROL (;;�77 ) / I II II II II II II II II II II II II II II FIRST FL SCALE: Custom TRY (0 OOR MECHANICAL W z� z _w O O z O O U U 06 w(DLO LO z X � Qm wo RECEIVED Aug 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U z U w Oc o W � wQ >� LIJ W ou Z N Z �0 o � 0 N W a 0 w CV M L6 O I-.� a0 a) Z Q 4- 6 C) � N O LN a J U 4-1 -- Z Q Iw- Q W Q V m Z W Q c() a 0 LIJ M 1 cn .0