Loading...
FIR2021-0066+Fire_Alarm_Plan+7.1.2021_1.59.09_PM+2279960EVERETT CLINIC EDMONDS STORAGE TI FIRE ALARM SYSTEM SHEET NUMBER SHEET TITLE FA-01 SYSTEM INFORMATION FA-02 SINGLE LINE DIAGRAM & CALCULATIONS FA-03 FLOOR FIRE ALARM PLAN HEETINDEX ADD TWO(2) NEW STROBES TO AN EXISTING FIRE ALARM SYSTEM QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT E E FIRE ALARM HORN STROBE EXISTING EXISTING 4S BOX CEILING (EXISTING) 2 FIRE ALARM STROBE EGCFVM KIDDIE-EDWARDS 4S BOX CEILING (CEILING MOUNT) V END -OF -LINE N/A N/A N/A N/A RESISTOR A.F.F. ABOVE FINISHED N/A N/A N/A N/A FLOOR E EXISTING N/A N/A N/A N/A DEVICE --- F.B.O. FURNISHED BY N/A N/A N/A N/A OTHERS N/A NOT N/A N/A N/A N/A APPLICABLE --- RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT N/A N/A N/A N/A REMOVE BLUE AS BUILT N/A N/A N/A N/A NOTES TO CAD SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE S SIGNALING CIRCUIT TWO #14 FPLP RED (JACKET) EDMONDS, WASHINGTON 0 TO EXIST DEVICE CEILIN TI LE ■e HORN STROBE STROBE TYPICAL NAC CIRCUIT WIRING DETAIL 4" SQUARE OR OCTAGONAL BOX MOUNTING PLATE CEILING MOUNT HORN STROBE OR STROBE ONLY HORN/STROBE, STROBE MOUNTING (DROP CEILING HARD LID - CEILING EOL STROBE i bNIL) L 4" SQUARE OR OCTAGONAL BOX MOUNTING PLATE CEILING MOUNT .10 HORN STROBE OR STROBE ONLY HORN/STROBE, STROBE MOUNTING (HARD LID RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2022 z 0 cn w w a w w � r0 o 0` _ 0 z N o � � z o N Lu x a yw Z~ w oLc) N LLJ N Q o Cn N � � W W m U m w z z 0 Q w w U co w 0 0 W Q N co N O O 0aaaaa SCALE: AS NOTED DRAWN BY: R- CRUZ DESIGNED BY: T. QUAALE DATE: 06 28 21 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 59096-1 Java uaralan )ecurITY JYSTems, Inc. All KIgnTS Keserve SHEET FA- 01 S � 2S 2S FROM EXISTING NAC DEVICES E S1_10 75cd S1_11 15cd SINGLE LINE DIAGRAM Sl-12 15cd FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project: EVERETT CLINICS EDMOND Panel: EXISTING EBPS 6A BOOSTER POWER SUPPLY Date: June 28, 2021 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 90 90 0 90 90 0 A TOTAL FIRE ALARM POWER SUPPLY 90 90 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / rnA) 0 126 Total(A)= 90 Total(B)= 216 CALCULATION D Total current ratings of all devices in system (line A + line B + line C) 90 216 E Total current ratings converted to amperes (line D x .001) 0.09 0.216 F Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 G Multiply lines E and F Total Standby AH 2.16 H Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 1 Multiply lines E and H Total Alarm AH 0.0179928 J Add lines G and I Total Standby and Alarm AH 2.1779928 K Multiply line J by 1.2 (20% extra insurance to meet desired performance) 2.61359136 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 *** RECOMMENDED MINIMUM BATTERY SIZE = 12VDC 7.0 AMP-HR *** Notification Appliance Circuit Detail PROJECT: EVERETT CLINIC EDMONDS Panel: EXISTING EBPS 6A BOOSTER POWER SUPPLY Wire Resistance 2.58 Date: June 28, 2021 CURRENT TOTAL= 126.00 EGCF-HDVM015cd 641 0 EGCF-HDVM@30cd EGCF-HDVM(a--)75cd 137 0 EGCF-HDVM@95cd 2 SCWL @15cd 63 126 SCWL @30cd p DEVICES 2 TOTAL mA= 126 14 50 23.97 126 Total Wire Resistance ( R) (W L - 2) * (R/ft) 0.26 Total Device Load, Amps (1) _ (Total Cct Load) 1 0.13 Voltage Drop ( E) (E= I * R) 0.03 EOLolta 23.97 ..- Voltage QTY Device Type Current Tota I Size Le ngth at EOL Tota I EGCF-HDVM@15cd 54 0' - EGCF-HDVM@30cd 0 EGCF-HDVM@75cd 137 0 EGCF-HDVM@95cd 0 SCWL @15cd 63 0 SCWL @30cd "TOTAL '90 0 DEVICES 0 mA= 0 14 0 24.00 0 Total Wire_ Resistance ( R) (WL * 2) * (R/ft) 0.00 Total Device Load, Amps (1) (Total Cct Load) 0.00 Voltage Drop ( E) (E= I - R) 0.00 EEOL Voltage M 24 - E) 1 24.00 CALCULATIONS RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01/2022 CO z 0 cn LLJ LLJ V) Q W w __S r(D o 0\ 0 z N o z C) — N LQ x 3: Q yw Q Ln Ln U Q N Q f— � CD � W m 0 � w Z z 0 Q CL co W 0 W Q N 00 N O 0aaaaa H O Ir > N p WNO U) Q Nz °z NJ �re c1n 0� 43 o rJU) w 0Qo W IO � N w w w ,w Z O 5161 W Z_ J W J (D M SCALE: AS NOTED DRAWN BY: R. C IFS U Z DESIGNED BY: T. QUAALE= DATE: 06/28/21 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 59096-1 Cogyright 2013 by Guardian Security Sysfems, Inc. All Riqhfs Reserved SHEET FA-02 FLOOR FIRE ALARM PLAM SCALE: 1 /21I = 1 I-01I 101 RONALD MANSFIELD JR. NICET LEVEL IV CERT. #111878 EXP. 09/01 /2022 cn z 0 w w Q w J W --s r0 O O\ oft CY\ z N o Z O N 44 x a yw W Z~ w Q�LC) �milli oL,) N LJ_J N Q � � O C/� N � � W W 52 m 0 � w o' z 0 Q CL V) w 0 0 I� VI W F-- Q 0 N Co N to O 2- <<< O > N p WNO U) Q Nz °z N �c�n O� 43 o rJU) w 0Qo W IO r �2 � N in w w ,w LU LL rr 0 0 J LL SCALE: AS NOTED DRAWN BY: IFS. C IFS U Z DESIGNED BY: T. QUAALE= DATE: 06/28/21 BACKROUND PLAN PROVIDED BY: JOB NUMBER: 59096-1 Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved SHEET FA-03