ENG2021-0406 ROW PERMITOF WAY EUC PERMIT PERMIT NUMBER City of Edmonds EdmondsRIGHT A•:0i 1 141. www.cityofedmonds.gov Description: ZIPLY-CHECK CONDUIT AND IF DAMAGED, BORE & PLACE NEW CONDUIT ISSUED: 11/01/2021 Address: 130 W DAYTON ST EDMONDS WA 98020-4130 EXPIRES: 05/01/2022 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 27032300409600 Isle]' NAME TYPE NAME ADDRESS PHONE APPLICANT ZIPLY FIBER 1800 41ST ST, EVERETT WA 98201 (425)949-0230 CONTRACTOR PACIFIC CABLE CONSTRUCTION, INC. , EVERETT WA 98201-1255 (425)348-7735 OWNER EDMONDS PORT OF 156 W DAYTON ST, EDMONDS WA 98020 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $0.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW 11 /01 /2021 RELEASED BY DATE Printed: Monday, November 01, 2021 8:13:18 AM 1 of 2 -KRWOF WAY EUC PERMIT PERMIT NUMBER City of • • • AveA•:•• 1 141. www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. TRAFFIC CONTROL Traffic Control per approved plan and MUTCD. All Flaggers shall be certified. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS RESULT INSPECTION MEN A-1 JOB START X-2 ENGINEERING FINAL" Printed: Monday, November 01, 2021 8:13:18 AM 2 of 2 ENG2021-0406 of E°M°tio� RECEIVED RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION OCT 15 2021 Complete and submit this Application in accordance with the Submittal CITY OF EDMONDS /Ivc. i aa° Requirements outlined in Right -of -Way permit Handout E6�. DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. SECTION A General • Project Name 5504204-519 Site Address or if no site address use Property Address at NW corner of project area: 130 W Dayton Street, Edmonds, WA Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of Company Ziply Fiber Franchise Ordinance No: WN U-17 Point of Contact Mike HaKahan Title Engineer Address 1800 41 St St, Ste N 100 city Everett State WA Zip 98203 Phone 425-949-0230 Email mike.hakahan@ziply.com Contractor and Authorized Agent of Owner (see note below) Name of company Pacific Cable Construction Contractor Contacts Primary Name During Construction Danielle Harrera Agent Name Danielle Herrera Title Permit Manager Title Permit Manager Mobile 425-348-7735 Address PO BOX 573 Email danielle@paccab.com City Woodinville State WA Zip 98072 Secondary Name Phone 425-348-7735 Title Email danielle@paccab.com Mobile City of Edmonds Business License No: PACI FCC954PJ Email State License No: 3636CON 1096 Of Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) Ix Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Telecommunications and broadband arovider Zialy Fiber to: Locate HH3 in parking lot near rear entrance of 110 W Dayton ST and check conduit from HH3 to HH4 for access to pull new 12-port tail through. If conduit is damaged or not available. D-Bore SE from HH3 to HH4 (19oFT) and place new 4" conduit in new path. Locate MH6 at iio W Dayton ST and pull a 12-port fiber tail in existing/new conduit from the customer MPOE to HH4, to HH3, to HHl, and then to MH6. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: VZtelecommunications ❑ cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes No X 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? X If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 5 1 How many are to be added? i City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: 4—a a)a&- DATE: 10/15/2021 APPLICANT PRINTED NAME: TRACI WEST APPLICANT TITLE: OSP ENGINEER AND PERMIT COORDINATOR NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 PLANNING NOTES: The Planning solution for this order from planner Ed Meneses is: Existing Copper Term: C9EDM A900 Count: C9EDM DFV,801-825 FDT: New 12-port term Fiber Count: 5XD+FC1031,78+6XD CO CLLI CODE 1: HLLKWAXX CUST CLLI CODE 2: Facilities note: Reserve HLLKWAXX H5032,145. GIS note: Reserve HLLKWAXX FC1031,78. OSP Estimate: N/A OSP Blanket: 5504204-519 Solution: HLLKWAXX - 130 W DAYTON ST, EDMONDS, WA Locate HH3 in parking lot near rear entrance of 110 W Dayton ST and check conduit from HH3 to HH4 for access to pull new 12-port tail through. If conduit is damaged or not available, D-Bore SE from HH3 to HH4 (190FT) and place new 4" conduit in new path. NOTE: FROGS records show existing conduit from HH3 to HH4. Fielder site walk has determined D-Bore is required from HH3 to HH4. Locate MH6 at 110 W Dayton ST and pull a 12-port fiber tail in existing/new conduit from the customer MPOE to HH4, to HH3, to HH1, and then to MH6. In MH6, splice H5032,145 from the RBN-96 cable to XD,6 on the 12-port tail (5XD+FC1031,78+6XD). Locate FDH H5032 at 201 2ND Ave S and place a red jumper from FC1031,78 port 6 (in Hub) and H5032,145 port 145. Test Fiber FC1031,78 from MPOE back to HALLS LAKE CO BAY: 011, MS: 03, Connector: 06. Feeder Fiber: FC1031,78 from MPOE back to HALLS LAKE CO on 2100/BAY: 011, MS: 03, Connector: 06. Distribution Fiber: H5032,145 port 145 red jumper to FC1031,78, port 6. Fiber Trunk Schematic: HLLK FTTCS FTTP.DWG, Sheet 17 APP Date: 09/20/21 Order: PSR 3396649 Customer Desired Due Date: 10/29/21 Carrier: N/A Customer End User: BEST WESTERN PLUS EDMONDS HARBOR INN Address: 130 W DAYTON, EDMONDS, WA 98020 Service: 500M Circuit ID: 86/L1XN/722664//NWFC/ Exchange: HLLK/51419 OA/CO: 032/962 Copper Terminal: C9EDM A900 Fiber Terminal: None LCON: SITE LCON: Mark Raden RECEIVED SITE TEL NO: (206) 300-5265 SITE EMAIL: mlraden@yahoo.com OCT 15 2021 ALCON: ALCON: None Provided ALCON TEL NO: None Provided ALCON EMAIL: None Provided CITY OF EDMONDS DEVELOPMENT Project Manager: Bryan Graham SERVICES DEPARTMENT DSAT#: 2191829 SF#/PON: SF00006896UNIN I CERTIFY THAT THE WORK I COMPLETD ON THIS WORK ORDER AND AS -BUILT IS IN COMPLIANCE WITH FRONTIER QUALITY STANDARDS AS IDENTIFIED ON THE IPQIP CHECKLIST. (SIGNATURE AND DATE) TOTAL ALLOTTED HOURS CONTACT SUPERVISOR IF ADDITIONAL HOURS ARE REQUIRED TO COMPLETE PROJECT CAP. X-TIME MAINT CREW 0 0 0 SPLICING 0 0 0 W.O. DRIVER CONSTRUCTION START I@ ETHERNET 10/11/21 ❑ CIAC IN SERVICE DATE ❑ DAMAGE 12/03/21 ❑ OTHER CONSTRUCTION ❑ FLAGGING ❑ BRUSHING ❑ CONTRACTOR PERMITS MUNICIPALITY: CITY OF EDMONDS ❑ BLANKET ® TCP/TRAFFIC ® DETAILED (NOT BLANKET) ❑ NO PERMIT REQUIRED JOINT POLE JFN/NJUNS# ® NO JPN REQUIRED POLE JPN JPN OWNER TO FROM ❑ ❑ ❑ POWER ❑ ❑ ❑ CATV ❑ ❑ ❑ FRONTIER ACCOUNT CODES ❑ 2411.001 POLES ❑ 2422.201 UG FIBER ❑ 2421.101 OH COPPER ❑ 2441.001 CONDUIT ❑ 2421.201 OH FIBER ❑ 34XX.XXX REMOVAL ❑ 2422.101 UG COPPER ❑ 64XX.XXX MAINT. SITE CONTACT: MARK RADEN 206-300-5265 SCHEDULING: PHONE: ENGINEER: PHONE: FACILITIES: PHONE: FIELDED BY: JOHN WOOD 425-261-1412 MIKE HAKAHAN 425-949-0230 ELAINE GRACE 425-263-4001 SHANE NEWTON � ziplyfiber HLLK - 500M - ASR# 3396649 - BEST WESTERN 130 W DAYTON, EDMONDS, WA PROJECT 5504204-519 C.O. AREA: 962 NUMBER: EXCH. CODE: 51419 DRAWN DATE: ENGR: M. HAKAHAN NTY: SNOHOMISF 10/11/21 PHONE:425-949-0230 FILE: SCALE: 1:100 TAX DISTRICT: DWG 1 OF 4 TWNSHP: 27N RING: 3E SEC: 23D SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM 0 05.2010 RBN 96 �. OPT / HLLKWAXX H5032,97-110+ XD,111-120+ HLLKWAXX H5032,121-131+ HLLKWAXX FC1031,101+ HLLKWAXX H5032,133-168+ XD,73-96 I � � W DAYTON ST (W DAYTON S I 434 09. 20 RBHL XX H5032,145 296' AE 100 24 . C9EDM DFV,801-900 FTTP PIGTAIL 1000FT 12 XD,1-5+ HLLKWAXX H5032,145+ XD,7-12 ' Utility patches shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. Z 09.200� �- �RBN 96I ILH52 782 09.2009 I HL,97-111+ RBN 96 I C1031,81+ XD,97-144+ i HILL113-131+ HLLKWAXX H5032,145-168+ I 1031,101+XD,73-96 PLACE FIBER TAIL HLL133-168+ROM MH6 TO MPOE.xD,73-96 SEE MH DETAIL WP4.J HH14F7 VC 60' 4 i 168 --- HH1 C9EOM 110 / LLK IN: HL OUT: BORE 190' 1-4- ,FROM HH3 TO HH4 SEE NOTES RIGHT MPO INe XD,1-5+ H5032,145+ XD,7-12 OUT: RECEIVED OCT 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 130 BEST WESTERN PLUS EDMONDS HARBOR INN 130 W DAYTON 200 2ND AVE S AKF 100 26 1 RED JUMPER C9EDM DFV,8Q1-900 FC1031,78 0 09.2009 1 TO H5032,145 FDT MDU 12P IOFT 12 HLLKWAXX H5 32,157-168 HLLKWAXX 1­15037 1 FDH 48/288 0 IN: HLLKWAXX FC1031,73-78+ e8p� I XD,79-82+ XD,101+ HLLKWAXX FC1031,102-104+ < 101886 XDJ 05-108+ 4XX H5032,1,57-168 XDJ9-24 OUT: HLLKWAXX H5032,1-432 5022 FIT7 302 09.2009 RBN 288 I HLLKWAXX H5032,1-2+ HLLKWAXX FC1031,79+ HLLKWAXX I H5032,4-46+ XD,47-48+ HLLKWAXX H5032,49-57+ HLLKWAXX I FC1031,82+ HLLKWAXX H5032,59-64+ HLLKWAXX FC1031,105-108+ HLLKWAXX I H5032,69-111+ HLLKWAXX FC1031,81+ LLKWAXX HLLKWAXX H5032,113-131+ FC1031,101+ HLLKWAXX II I H5032,133-288 1AYTMLS_T_ QaAyTQ.N_ Cs ®s I 102 09.2009 RBN 56 HLLKWAXX FC1031,73-82+ J HLLKWAXX FC1031,101-10F r XD,11-48 I 194' AE 100 24 C9EDM DFV,801-840+ XD,41-100 Locate HH3 in parking lot near rear entrance of 110 W Dayton ST and 1 check conduit from HH3 to HH4 for access to pull new 12-port tail through. If conduit is damaged or not available, D-Bore SE from HH3 1 to HH4 (190FT) and place new 4" conduit in new path. 244' I NOTE: FROGS records show existing conduit from HH3 to HH4. AE 25 24 C9EDM DFV,801-825 Fielder site walk has determined D-Bore is required from HH3 to HH4. > Locate MH6 at 110 W Dayton ST and pull a 12-port fiber tail in Q existing/new conduit from the customer MPOE to HH4, to HH3, to w HH1, and then to MH6. I � z can In MH6, splice H5032,145 from the RBN-96 cable to XD,6 on the 415' 1 12-port tail (5XD+FC1031,78+6XD). AE 50 24 C9EDM DFV,801-804+ XD,805+ OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING C9EDM DFV,806-813+ ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY XD,814-815+ C9EDM DFV,816-840+ UTILITIES MAY REQUIRE A SEPERATE PERMIT. I CERTIFY THAT THE WORK I COMPLETD ON THIS WORK ORDER AND AS -BUILT IS IN COMPLIANCE WITH FRONTIER QUALITY STANDARDS AS IDENTIFIED ON THE IPQIP CHECKLIST. (SIGNATURE AND DATE) TOTAL ALLOTTED HOURS CONTACT SUPERVISOR IF ADDITIONAL HOURS ARE REQUIRED TO COMPLETE PROJECT CAP. X-TIME MAINT CREW 0 0 0 SPLICING 0 0 0 W.O. DRIVER CONSTRUCTION START ® ETHERNET 10/11/21 ❑ CIAC IN SERVICE DATE ❑ DAMAGE 12/03/21 ❑ OTHER CONSTRtY=Nt - - ❑ FLAGGING ❑ BRUSHING ❑ CONTRACTOR PERMITS MUNICIPALITY: CITY OF EDMONDS ❑ BLANKET ® TCP/TRAFFIC ® DETAILED (NOT BLANKET) ❑ NO PERMIT REQUIRED JOINT POLE JFN/NJUNS# ® NO JPN REQUIRED POLE JPN JPN OWNER TO FROM ❑ ❑ ❑ POWER ❑ ❑ ❑ CATV ❑ ❑ ❑ FRONTIER ACCOUNT CODES ❑ 2411.001 POLES ❑ 2422.201 UG FIBER ❑ 2421.101 OH COPPER ❑ 2441.001 CONDUIT ❑ 2421.201 OH FIBER ❑ 34XX.XXX REMOVAL ❑ 2422.101 UG COPPER ❑ 64XX.XXX MAINT. SITE CONTACT: MARK RADEN 206-300-5265 SCHEDULING: JOHN WOOD PHONE: 425-261-1412 ENGINEER: MIKE HAKAHAN PHONE: 425-949-0230 FACILITIES: ELAINE GRACE PHONE: 425-263-4001 FIELDED BY: SHANE NEWTON � ziplYfiber XD,41-50 I� HLLK - 500M - ASR# 3396649 - BEST WESTERN / 130 W DAYTON, EDMONDS, WA 1 Applicant shall repair/replace all ENGINEERING DIVISION PROJECT C.O. AREA:962 damage to utilities or frontage APPROVED AS NOTED NUMBER: 5504204-519 EXCH. CODE: 51419 OWNER/CONTRACTOR IS RESPONSIBLE FOR improvements in City right-of-way DRAWN DATE: ENGR: M. HAKAHAN NTY: SNOHOMIS EROSION CONTROL AND DRAINAGE per city standards that is caused or 10/28/2021 10/11/21 PHONE: 425-949-0230 FILE: occurs during the permitted project. SCALE: 1:100 TAX DISTRICT: DWG 3 OF 4 TWNSHP: 27N RNG: 3E SEC: 23D wei2121a O SIGNALIZED INTERSECTION O CONE (CANDLESTICK) TYPE III BARRICADE WORK TRUCK WORK ZONE LIMITS EMEP WARNING SIGN WHERE REQUIRED) I)IRE(NOTCPAAVVEMMEENTT MARKINGS) (AS NEEDED) a ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) SIGN LEGEND: � w1-640 0 LW20-1 \W9-3R \Wl-4L X X X— ROAD RIGHT LANE WORK CLOSED AHEAD AHEAD W20-1 W9-3R CLOSURE O Wl-4L CENTER LANE CLOSED AHEAD W9-3C WI-6R SUNSET AVE (25 MPH) I W DAYTON STREET � I v 11*1 4 L (25 MPH) "" ! " W1-6R -� o... DRIVEWAY TO PARKING LOT (I BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' FFER SPACE (B NOTE: MON. - FRI. = 7:00am TO 4:00pm ENGINEERING DIVISION APPROVED AS NOTED lQa i,W41,,,,44? 10/28/2021 VV CHANNELIZATION DEVICE SPACING (feet) MPH F TAPER TANGENT 50/70 40 80 25/30 20 40 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANE POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 10 105 150 205 270 450 500 550 - - - 11 115 165 225 295 495 550 605 660 12 125 180 245 320 540 600 660 720 780 840 EDMONDS WAY (25 MPH) NORTH RECEIVED OCT 15 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. O ATCO COMMUNICATIONS SE"ICES, LLC WWW.atcotelecom.com 360.563.9000 708 First Street Snohomish, WA 98290 WSTCT# 012569 zilyfiber p Everett, WA 98206 I vi 04 0 0 :2 Ill Lw F_ w w F- z 0 Q 0 0 W z U j O w a Q 0 z 0 Ld Q w z D U) 0 z Q w w z 0 i Q 0 0 Q O J w U N Q ry Ld Z U Ld z J 0 3 v 3r 0 0 a 0 I rn I 0 (V 0 In Q z n w DATE: 10/15/2021 DESIGNED BY: ATCO TELECOM ATCO CONTACT: 360.562.9021 SCALE: � OT TO SCAT F SHEET: O NO: 1 OF "