Loading...
2017-1335 Mietzner lot 2City of Edmonds OF EDP 0�° PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 �sr, t s90 DATE: November 27, 2017 TO: Mike Mietzner MIKEM@MIETZNERGROUP.COM FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2017-1335 Project Address: 8609 244TH ST SW #2, EDMONDS Scope: Addition, VB construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the `clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: A3: In accordance with the provided lower floor lateral design, it appears that detail 4 is called out for the window of room B2 and is not indicated on the plans. Please clarify and add to the plans. 2. The gravity loads for the indicated girder truss do not appear to have been accounted for. Please indicate on the plans the size and location of the posts on both the first and second floor plans. Furthermore; indicate any additional enlarged footings or isolated piers on the plans. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 3 Page 3 of 3