Loading...
APPROVED BLD BLD2021-1272+Plans+9.13.2021_1.59.57_PM+240532331 51 61 71 C VIRGINIA MASON EDMONDS FAMILY MEDICINE EXAM ROOMS WTHE BOWL OF EDMONDS Marina Beach park Edmonds INoodway Esperance (1_� q0F.. 99 I ECHO LAKW' Shoreline 7315 212th Street S.W. Lynnwood sxa� Ed ands Professional Center I (fr Mountlake Terrace VICINITY MA 2( M1 Q LD Prestige Post -Acute and ReN b ... u Auda s Farber ',hap Virg Rarrea s Famois Fzza. 3urger K.n9 y'! Virg 212th St SW Woodway thigh xhool � I311� t • Q 215111 5t SW S ids-Woodway Nigh School Swedish 56st SW &wed sh Edmords Ca rr n s � � 216th St SW w Swedish SW a lty �s C'nic - Edm... ',cattle',k r, & Laser ztoth St SW V I LOCATION 1 Ds Lake Forest Park P NORTH PROJECT LOCATION -ra 3�ates eoslal Service' Wa greers 208th St SW F, 1101,, 51 SW aye Neo Edmonds z 212th St SW Q � r e`rl r _ Nk16 �, �r � y ll rtr Kali Creek Platt Electric 5ugl Br er PLAN NORTH A KP IX COOLING LOAD BASIS OF DESIGN: Plan set is for Mechanical ONLY. Additional information is for reference. EDMONDS. WASHINGTON PROJECT DESCRIPTION: PROJECT LOCATION: 7315 212th STREET S.W. SUITE 207 EDMONDS, WASHINGTON 98026 OWNER: VIRGINIA MASON xxx SEATTLE, WASHINGTON 98101 CONSULTANTS: ARCHITECT SABA 2 NICKERSON STREET SUITE 200 SEATTLE, WA 98109 PHONE: (206) 957-6400 CONTACT: xxx sabarch.com MECHANICAL ENGINEERING ENGINEERING ECONOMICS INC. 1201 WESTERN AVENUE, SUITE 325 SEATTLE, WASHINGTON 98101 PHONE: (206) 622-1001 FAX: (206) 622-5747 CONTACT: DWIGHT GRAY www.eeiengineers.com DRAWING INDEX: GENERAL GO.01 COVER SHEET, LOCATION PLANS AND NOTES GO.02 SYMBOLS AND ABBREVIATIONS GO.03 SPECIFICATIONS GO.04 SPECIFICATIONS PHASE 1 MEP1.01 SCHEDULES AND DETAILS PHASE 1 MP1.10 SECOND FLOOR MECHANICAL AND PLUMBING PLANS — PHASE 1 E1.10 SECOND FLOOR ELECTRICAL PLANS — PHASE 1 City Of Edmonds Building Department Work MECH - DUCTWORK MODIFICATION Address 7315 212TH ST SW -------------------------------------------------- Owner EDMONDS FAMILY MEDICINE -------------------------------------------------------------- Approved Date : 09/30/2021 Building Official Eris. Ga� Nermlt Number'BLD2021-1272 ^-------- ^---------- r � 5o I PHASE 1 I I I I oo n o �000 0 — — — — — I I I I I PHASE 2 I I I I 17-1 I I I I 0 PHASING PLAN 0 NORTH CHECK SET Plans to comply with: 2018 IBC 2018 IMC CODE INFORMATION: • 01- SEATTLE BUILDING CODE (SBC) • 5 SEATTLE MECHANICAL CODE (SMC) • 2 18 SEATTLE ENERGY CODE (SEC) • 01 UNIFORM PLUMBING CODE (UPC) • 014 NATIONAL ELECTRIC CODE (NEC) • WASHINGTON STATE AMENDMENTS • STATE OF WASHINGTON AMENDMENTS TO THE ABOVE CODES • WAC 296-46B L&I SAFETY STANDARDS, ADMIN AND INSTALLATION LEGAL DESCRIPTION: PARCEL A: LOTS 6, 7 AND 8 AND THE SOUTH HALF OF LOT 9, BLOCK 5, SEATTLE HEIGHTS DIVISION 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 9 OF PLATS, PAGE 11, IN SNOHOMISH COUNTY, WASHINGTON. TOGETHER WITH THE EAST 60 FEET OF THE WEST 180 FEET OF LOT 10 AND THE EAST 60 FEET OF THE WEST 180 FEET OF THE NORTH HALF OF LOT 9, BLOCK 5, SEATTLE HEIGHTS DIVISION 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 9 OF PLATS, PAGE 11, IN SNOHOMISH COUNTY, WASHINGTON. TOGETHER WITH THE EAST 60 FEET OF THE WEST 120 FEET OF LOT 10, BLOCK 5, SEATTLE HEIGHTS DIVISION 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 9 OF PLATS, PAGE 11, IN SNOHOMISH COUNTY, WASHINGTON. PARCEL B: (ADJOINING PARCEL WITH DETENTION SYSTEM EXTENSION) THE EAST 60 FEET OF LOT 10 AND THE EAST 60 FEET OF THE NORTH HALF OF LOT 9, BLOCK 5, SEATTLE HEIGHTS DIVISION 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 9 OF PLATS, PAGE 11, IN SNOHOMISH COUNTY, WASHINGTON. PARCEL C: TOGETHER WITH LOT 10 AND THE NORTH HALF OF LOT 9, BLOCK 5, SEATTLE HEIGHTS DIVISION 4, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 9 OF PLATS, PAGE 11, IN SNOHOMISH COUNTY, WASHINGTON. EXCEPT THE EAST 60 FEET OF SAID LOTS. ALSO EXCEPT THE WEST 180 FEET OF SAID LOTS. SITE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. PARCEL NUMBERS: 005669-005-006-00 005669-005-006-02 005669-005-006-04 USE AND OCCUPANCY BUSINESS MERCANTILE (ACCESSORY USE) INCIDENTAL USE MEDICAL OFFICES PHARMACY OPEN PARKING GARAGE (AMBULATORY/OUTPATIENT) ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE AREA OF WORK — APPROVED PLANS MUST BF ON JOB SITS 0 KEY PLAN 0 NORTH i� C:)~ N N U C/� V O (0 •� O O O N O O Z O L X LL • W •ti O •� O G% o Co O � O h W E co O c N N O cncn Al Z Q O 0_ O U w 0 W W D W L w Q 0 6 z W U U Q J_ U) � � (n O 0 O Z Q� OC G Q 0 x W W U C o N O .F 4� - N 0 cn00 a, _ 0) 4 OL N O 0- Q� w 70 N41 s3 4� O N N I 0 Wn M0 r- LI-I RECEIVED Sep 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: DRAWN BY: RH RH DATE: APPROVED BY: 7/15/21 DG SCALE: FILE NAME: None .16 GO.01 PROJECT No: 21146.02 SHEET TITLE: Cover Sheet and Location Plans SHEET NUMBER: GO.01 0 4. C G I MEP SYMBOLS LEGEND (NOT ALL SYMBOLS ARE USED ON THESE DRAWINGS) SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SINGLE DOUBLE HVAC PIPING AND PLUMBING MEDICAL GASES TELEPHONE AND COMPUTER SYSTEMS ABBREVIATIONS LINE LINE - DOMESTIC COLD WATER MA MEDICAL AIR TELEPHONE OUTLET MOUNTED AT +18" AFF A AMPERES �® �® DUCT CONNECTION TO SUPPLY DIFFUSER, REFER TO DETAILS DOMESTIC HOT WATER MAI MEDICAL AIR INTAKE (UPSTEAM OF THE MEDICAL AIR COMPRESSOR) TELEPHONE OUTLET MOUNTED AT +54" AFF AFF ABOVE FINISH FLOOR HOT WATER CIRCULATING MV MEDICAL VACUUM W AP ACCESS PANEL DUCT CONNECTION TO RETURN GRILLES, REFER TO DETAILS - - W - - SOIL OR WASTE (BURIED) MVE MEDICAL VACUUM EXHAUST (DOWNSTEAM FROM < COMPUTER DATA OUTLET AHU AIR HANDLING UNIT W SOIL OR WASTE (SUSPENDED) THE MEDICAL VACUUM PUMP) � COMBINATION TELEPHONE/DATA OUTLET AD AREA DRAIN ®® DUCT CONNECTION TO EXHAUST GRILLES, REFER TO DETAILS - - -V- - - PLUMBING VENT N NITROGEN C CONDUIT 2 NITROUS OXIDE EQUIPMENT CB CIRCUIT BREAKER SUPPLY AIR (SA) ELEVATION CHANGE (SOLID LINE UP, G NATURAL GAS 0 OXYGEN CC CONTROL CONTRACTOR BROKEN LINE DOWN ) D EQUIPMENT DRAIN ELECTRICAL PANELBOARD DIFF DIFFUSER DI DEIONIZED WATER RETURN AIR (RA), RELIEF AIR OR EXHAUST (SOLID LINE UP, PC I�G PUMPED CONDENSATE EVAC WASTE ANESTHETIC GAS EVACUATION EQUIPMENT CONNECTION, E=EMERGENCY POWER DG DOOR GRILLE BROKEN LINE DOWN) GATE VALVE (ISOLATION VALVE) IEN ZONE VALVE BOX DUCT RISE/DROP WITH 90° ELBOWS (RECTANGULAR DUCTS) Dom BALL VALVE AREA ALARM PANEL MOTOR CONNECTION -SINGLE PHASE (E) EXISTING EC ELECTRICAL CONTRACTOR 45 D 45 D BUTTERFLY VALVE MASTER ALARM PANEL DUCT RISE/DROP W/ 45° ELBOWS (RECTANGULAR DUCTS) WALL CEILING /a MOTOR CONNECTION -THREE PHASE ELEV ELEVATION PRESSURE REDUCING VALVE ❑A MEDICAL AIR OUTLET EM EMERGENCY —�2 F-FIF-2 DUCT RISE/DROP W/ 90° ELBOWS (OVAL DUCTS) PRESSURE REGULATING VALVE 0 MEDICAL VACUUM OUTLET TRANSFORMER E EMERGENCY POWER OFF EAT ENTERING AIR TEMPERATURE D D DUCT RISE/DROP W/ 45° ELBOWS (ROUND OR OVAL DUCTS) 2-WAY AUTOMATIC CONTROL VALVE ❑N NITROGEN OUTLET CIRCUITS EQ EQUAL DISTANCE 2 �2 NITROUS OXIDE OUTLET 3-WAY AUTOMATIC CONTROL VALVE a ❑O OXYGEN OUTLET BRANCH CIRCUIT WIRING SHOWING HOMERUN TO PANELBOARD/ EWT ENTERING WATER TEMPERATURE —�2 DUCT RISE/DROP W/ 90° ELBOWS (ROUND DUCTS) 2-WAY AUTOMATIC CONTROL VALVE (TWO POSITION) 0 EVACUATION 3A1 1 / '3'S CIRCUITS INDICATED. HASH MARKS INDICATE NUMBER EXH EXHAUST W OF WIRES. #12 AWG WIRE U.O.N. TWO WIRES PLUS ESP EXTERNAL STATIC PRESSURE R=1.5 W RADIUS ELBOW 3-WAY AUTOMATIC CONTROL VALVE (TWO POSITION MODULATING) PULSE SENSOR GROUND IF NO HASH MARKS SHOWN. LONG HASH MARK DENOTES NEUTRAL. INDICATES GROUND WIRE. FCO FLOOR CLEAN OUT SQUARE ELBOW WITH TURNING VANES SAFETY RELIEF VALVE HIGH/LOW PRESSURE SWITCH CONDUIT CONCEALED (INCLUDING ABOVE SUSPENDED CEILING FD GC FLOOR DRAIN GENERAL CONTRACTOR J 45 SQUARE/RECTANGULAR BRANCH TAKE -OFF Ya W s � VACUUM SWITCH & UNDER RAISED FLOOR) GFI GR GROUND FAULT CIRCUIT INTERRUPTER GRILLE W OR 6" MIN. SOLENOID VALVE - - - - - CONDUIT BURIED (UNDERGROUND OR IN FLOOR SLAB) Q VACUUM GAUGE HOA HAND/OFF/AUTOMATIC SELECTOR SWITCH RECTANGULAR/ROUND, ROUND/ROUND BRANCH TAKE -OFF E GATE VALVE WITH HOSE END AA AREA ALARM PANEL RACEWAY UP IE INVERT ELEVATION W C BALL VALVE W/ HOSE END DVB DOUBLE VALVE BOX RACEWAY DOWN JB JUNCTION BOX VRADIUS TEE � CHECK VALVE E01 EMERGENCY OXYGEN INLET LAV LAVATORY R=1.5 W �� RACEWAY STUB -OUT WITH BUSHING LAT LEAVING AIR TEMPERATURE SQUARE TEE W/ TURNING VANES STRAINER WITH BLOW OFF MA MASTER ALARM PANEL HOMERUN TO PANEL OR LOCATION NOTED LWT LEAVING WATER TEMPERATURE � MVP MEDICAL VACUUM PLANT MA MIXED AIR W BULLHEAD TEE STRAINER OM OXYGEN MANIFOLD CIRCUIT CONTINUATION MD MOTORIZED DAMPER 45' TRANSITION -ECCENTRIC (15° MAX. SUPPLY) (30° THERMOMETER S VACUUM BOTTLE SLIDE J J � a JUNCTION BOX CEILING OR WALL MOUNTED MCB MAIN CIRCUIT BREAKER MAX. RETURN/EXHAUST) 4 WG WALL GAUGE MC MECHANICAL CONTRACTOR 'T' THERMOMETER IN WELL PB PULL BOX MCC MOTOR CONTROL CENTER -2 �. TRANSITION - CONCENTRIC (15° MAX. SUPPLY) (30° ML MOTORIZED LOUVER -2 MAX. RETURN/EXHAUST) SENSOR WELL — EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) MVD MANUAL VOLUME DAMPER BOOT TEE TAKE OFF FROM THE BOTTOM OF THE DUCT BOTTOM TT LIGHTING (N) NEW OF THE DUCT TEMPERATURE SENSOR IN WELL FLUORESCENT FIXTURE, WALL MOUNTED CONDUIT SEAL N NEUTRAL 45 DEG. RADIUS ELBOW T TEMPERATURE SENSOR �WM--Vd SURFACE METAL RACEWAY (WIREMOLD G-4000 SERIES) NC NORMALLY CLOSED Y WITH RECEPTACLES AND/OR DEVICES INDICATED NO NORMALLY OPEN BELLMOUTH TAKE OFF WITH VOLUME DAMPER PRESSURE GAUGE IN FIXTURE INDICATES SWITCHLEG CONTROL N.I.C. NOT IN CONTRACT � Q SURFACE MOUNTED OR RECESSED LIGHTING FIXTURE NTS NOT TO SCALE 2 BOOT -TEE TAKE OFF WITH VOLUME DAMPER PRESSURE GAUGE WITH COCK SEE SCHEDULE WORK DEFINITION CIA OUTSIDE AIR PUMP Q WALL MOUNTED LIGHTING FIXTURE CONNECTION TO EXISTING OFCI OWNER FURNISHED, CONTRACTOR INSTALLED 2--®-� FLEXIBLE DUCT CONNECTOR PRV PRESSURE REDUCING VALVE ,_, PRESSURE/TEMPERATURE TEST TAP ]� RECESSED WALL WASHER ® DISCONNECTION FROM EXISTING RA RETURN AIR c'--� L VOLUME DAMPER p REDUCED PRESSURE BACKFLOW PREVENTOR o � STRIP LIGHT CEILING MOUNTED TYPE CFM RG RETURN GRILLE L/ GRILLE, REGISTER AND DIFFUSER CALLOUT SWBD SWITCHBOARD [�] MOTORIZED DAMPER FLOOR DRAIN FLOOR SINK 2 Sa STRIP LIGHT WALL MOUNTED SWITCH -SINGLE POLE, SUBSCRIPTS a,b, etc., DENOTES SIZE 1 M1.1 INDICATES DETAIL AND SHEET NUMBER WHERE ADDITIONAL INFORMATION ABOUT DETAIL CAN BE FOUND S SA SINK SUPPLY AIR CIRCUIT CONTROLLED SG SUPPLY GRILLE (', BACKDRAFT DAMPER ® FLOOR CLEANOUT EF MECHANICAL EQUIPMENT CALLOUT; REFER TO TSP TOTAL STATIC PRESSURE BD�—d-1 BDD lCo CLEANOUT S3 3-WAY SWITCH 1 MECHANICAL EQUIPMENT SCHEDULE TYP TYPICAL OPPOSED BLADE DAMPER UR URINAL i I WCO WALL CLEANOUT S4 4-WAY SWITCH WC-1 PLUMBING FIXTURE CALLOUT V VOLTS PARALLEL BLADE DAMPER WALL HYDRANT OR HOSE BIBB ]D DIMMER Fx LIGHTING FIXTURE TYPE - SEE FIXTURE SCHEDULE VAV VARIABLE AIR VOLUME 1 VTR VENT THROUGH ROOF c'-•-�-2 � J ACCESS PANEL io PIPE ELBOW UP P O PHOTOCELL WC WATER CLOSET PIPE ELBOW DOWN Fx LIGHTING FIXTURE TYPE -SEE LIGHT FIXTURE SCHEDULE 1 INDICATES SECTION AND SHEET NUMBER WHERE WCO WALL CLEAN OUT xx SECTION CAN BE FOUND WP WEATHERPROOF DUCT LINER PIPE TEE UP RECEPTACLES XFMR TRANSFORMER PIPE TEE DOWN FLEXIBLE DUCT ] PIPE CAP OR PLUG DUPLEX RECEPTACLE 1 O DETAIL / FLAG NOTE NOTE: NOT ALL REQUIRED PIPE FLEXIBLE CONNECTION DUPLEX RECEPTACLE ON EMERGENCY SYSTEM CHANGES IN DIRECTION AREail�2 FOURPLEX RECEPTACLE REVISION SYMBOL SHOWN ON THE DRAWINGS. ---------- REMOVE EXISTING MECHANICAL EQUIPMENT/WORK PIPE UNION � FOURPLEX RECEPTACLE ON EMERGENCY SYSTEM FIRE DAMPER CONCENTRIC REDUCER G DUPLEX RECEPTACLE -GROUND FAULT CIRCUIT ECCENTRIC REDUCER INTERRUPTER TYPE >— SMOKE DAMPER EXPANSION JOINT 0IG DUPLEX RECEPTACLE -ISOLATED GROUND COMBINATION FIRE/SMOKE DAMPER DIRECTION OF FLOW S DUPLEX RECEPTACLE -SAFETY TYPE OT THERMOSTAT PITCH DOWN IV DUPLEX RECEPTACLE -MOUNTED +3" ABOVE COUNTER BACKSPLASH, �T TEMPERATURE SENSOR K® RECEPTACLE 208V OR 240V, SINGLE PHASE TEMPERATURE SENSOR WITH TAMPER RESISTANT GUARD MCI CD N N (,% CNI O CO O CD (DO � X Cu • ti w .N c •� o G% o CD 00, r c W E CD C a> LO a O N N 9_1 �(nW Al z 0 0 E O U w 0 W W W U) LEI 0 0 z W U_ U Q � � a) U � � o N N G 0 N OC) LL U) 0 U)� O O O a_ (N 0' o z O O EX -0 N N � 3 C: E W W W � Ld RECEIVED Sep 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: DRAWN BY: RH RH DATE: APPROVED BY: 7/15/21 DIG SCALE: FILE NAME: None .16 GO.02 PROJECT No: 21146.02 SHEET TITLE: Legends and Abbreviations SHEET NUMBER: GO.02 0 c F 5 6 PLUMBING FIXTURE SCHEDULE TAG DESCRIPTION MANUFACTURER and MODEL FITTINGS FIXTURE CONNECTIONS ACCESSORIES NOTES CW FU I HW FU I W FU I V FU I L-1 WALL HUNG VITREOUS CHINA KOHLER K-2054-N-0 CHICAGO 895-317GN8AE73ABCD 3/8 I 1 3/8 1 1 1 /4 1 1 /4 1, 2, 3, 4, 5 GENERAL SCHEDULE NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIXTURES AND MOUNTING HEIGHTS. 2. PROVIDE INSULATION COVERS FOR EXPOSED PLUMBING UNDER ADA SINKS. 3. REMOVE AERATORS FROM ALL FAUCETS. 4. PROVIDE CLEANOUTS ON ALL SINK AND LAV TRAPS. 5. DECK MOUNTED CHICAGO FAUCET WITH 4" WRITBLADE HANDLES MOUNTED ON 4" CENTERS, DRILLED FOR CARRIER SUPPORT MATERIALS SCHEDULE ITEM MATERIAL JOINING REFERENCE INSULATION NOTES DESCRIPTION METHOD STANDARDS THICKNESS DOMESTIC COLD WATER DUCTILE IRON PUSH ON TYPE WITH ASTM-C151 PIPE (BELOW GRADE) CLASS 51 < 4" SINGLE RUBBER SEAL AWWA-C110 - > 2 1 /2" CLASS 50 > 4" OR MECHANICAL TYPE DOMESTIC HOT AND COLD < 3" NON -LEAD, WATER PIPE COPPER/L NON -ANTIMONY SOLDER ASTM-1388 1" FOR =&< 2" PIPE (ABOVE GRADE) =&> 3" GROOVED FITTING ASTM-13813 FLUX 1 1 /2" FOR > 2" PIPE MECHANICAL PIPE COUPLING SOIL AND WASTE PIPE SERVICE WEIGHT CAST IRON, NO -HUB ASTM-A888 - (ABOVE GRADE) COPPER DWV CISPI 301 SOIL AND WASTE PIPE SERVICE WEIGHT CAST IRON, NO -HUB FITTINGS WITH ASTM-A888 - (BELOW GRADE) XH CLASS HEAVY DUTY COUPLINGS CISPI 301 VENT PIPE CAST IRON WITH CAST NO -HUB 1" WITHIN 5 FEET FROM (ABOVE GRADE) IRON DRAINAGE FITTINGS BUILDING EXTERIOR VENT PIPE CAST IRON NO -HUB FITTINGS WITH ASTM-A74-94 - (BELOW GRADE) HEAVY DUTY COUPLINGS GALVANIZED STEEL, LOCK PER APPLICABLE SMACNA SUPPLY AIR DUCTWORK, FORMING QUALITY WITH A DUCT MANUAL, ALL JOINTS 1" (R-3.3) GAUGE PER APPLICABLE RECTANGULAR ZINC COATING OF 1.25 OUNCES TO BE SEALED WITH GASKETS SMACNA EXTERNAL WRAP SMACNA DUCT MANUAL, PER SQUARE FOOT ON OR LISTED MASTIC TYPE DUCT USE +4" PRESSURE CLASS EACH SIDE SEALANT (NO DUCT TAPE) GALVANIZED STEEL, SINGLE HEAVY DUTY FLANGE. WALL LINED -OR- WITH COORDINATE FLANGE EXTERNAL INSULATION, REQUIREMENTS WITH SUPPLY AIR DUCTWORK, SPIRAL LOCKSEAM, LOCK STRUCTURAL ENGINEER, 1" (R-3.3) GAUGE PER APPLICABLE ROUND AND FLAT OVAL FORMING QUALITY WITH A PER APPLICABLE SMACNA SMACNA EXTERNAL WRAP SMACNA DUCT MANUAL, ZINC COATING OF 1.25 OUNCES DUCT MANUAL, ALL JOINTS USE +4" PRESSURE CLASS PER SQUARE FOOT ON TO BE SEALED WITH GASKETS EACH SIDE OR LISTED MASTIC TYPE DUCT SEALANT (NO DUCT TAPE) GALVANIZED STEEL, LOCK PER APPLICABLE SMACNA RETURN AIR DUCTWORK, FORMING QUALITY WITH A DUCT MANUAL, ALL JOINTS 4" EXTERIOR DUCT GAUGE PER APPLICABLE ROUND AND FLAT OVAL ZINC COATING OF 1.25 OUNCES TO BE SEALED WITH GASKETS SMACNA (WITH ALUMINUM SMACNA DUCT MANUAL PER SQUARE FOOT ON OR LISTED MASTIC TYPE DUCT WEATHER PROOF BARRIER) EACH SIDE SEALANT (NO DUCT TAPE) FIBERGLASS RIGID, MOLDED, 3" WIDE VAPOR BARRIER PIPE INSULATION NON COMBUSTIBLE, TAPE ASTM-0547 - FOIL SCRIM KRAFT JACKET FLEXIBLE FIBERGLASS BLANKET, ASTM-0553 K VALUE= 0.27 © 75' DUCT INSULATION FACTORY APPLIED FOIL SCRIM VAPOR JOINT SEAL TYPE 1 - DENSITY= 3.0 LBS/CU FT KRAFT VAPOR BARRIER JACKET CLASS B-2 MINIMUM THERMAL RESISTANCE= 3.3 DUCT SOUNDLINING FIBERGLASS DUCT LINING (WHERE INDICATED ON COATED TO PREVENT FIBER ASTM-C1071 1" K VALUE= 0.27 @ 75' THE DRAWINGS) EROSION AT VELOCITIES UP TO DENSITY= 3.0 LBS/CU FT 4000 FPM GENERAL SCHEDULE NOTES: 1. ALL MATERIALS REQUIRED FOR THIS PROJECT MAY NOT BE LISTED IN SCHEDULE. 2. REFER TO MECHANICAL SPECIFICATIONS AND APPLICABLE STANDARDS FOR FURTHER INFORMATION. 3. ALL INSULATION LOCATIONS SHALL COMPLY WITH THE CURRENT WASHINGTON STATE ENERGY CODE. ROOF 77 REFER TO DRAWINGS FOR SIZES AND CONTINUATION — 1 WATER PROOF MASTIC CLAMPING RING MOLDED PIPE FLASHING BY G.C. REINFORCING RINGS MEMBRANE ROOF & LAP SEALANT BY G.C. STEEL FLANGE WELDED TO PIPE AND ANCHORED TO ROOF DECK OR RISER CLAMP WELDED TO DECK PIPE THROUGH ROOF DETAIL NOT TO SCALE GRILLE/REGISTER/DIFFUSER SCHEDULE TAG MANUFACTURER AND MODEL SERVICE FACE TYPE MOUNTING DAMPER MATERIAL NOTES TYPE S1 PRICE SMCD SUPPLY 4 WAY LAY -IN NA NA STEEL 1, 2, 3 R1 PRICE 1OFF RETURN PERF LAY -IN STEEL 1, 2, 3 l[0008 1. MAX NOISE CRITERIA NC SHALL BE NC = 35 UNLESS NOTED OTHERWISE. 2. SEE DRAWINGS FOR CFM AND NECK SIZE. (DIFFUSER INLET TO BE SAME SIZE AS FLEX DUCT) 3. PROVIDE BORDER TYPE TO MATCH CEILING. LIGHTING FIXTURE SCHEDULE TAG MANUFACTURER MODEL VOLTAGE BALLAST LAMP TYPE MOUNTING NOTES F1 LITHONIA GTL SERIES 2GTL 4 3OLGZ10 LP830 120 N/A LED RECESSED 1 F2 HEALTHCARE HALF CYLINDER WALL SCONCE HPSC 120 N/A LED WALL MOUNT 2 F3 LITHONIA GTL SERIES 2GTL 4 3OLGZ10 LP830 120 N/A LED RECESSED 1,3 SPECIFIC SCHEDULE NOTES: 1. NO DIMMING CONTROLS, INTEGRAL PIR SENSOR IN SWITCH 2. PROVIDE DIMMER SWITCH COMPATIBLE WITH FIXTURE 3. EMERGENCY 700 LUMEN BATTERY OPTION TO BE INCLUDED MCI CD N N � CD O Z. o X �co W .N t� •� o G% o CD r � V)L� N W �C/) C/) Al z o E O U w 0 W W D LEI a 0 6 z W U U � � U o N N G 0 N � LL (n 0 �^ VCJ C O O � 0 w (N N N 0 4-1 � � z O X O -0 N N N � 3 E W W Wui RECEIVED Sep 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: DRAWN BY: RH RH DATE: APPROVED BY: 7/15/21 DIG SCALE: FILE NAME: None .16 MEP1.01 PROJECT No: 21146.02 SHEET TITLE: Schedules and Details Phase 1 SHEET NUMBER: MEP1.01 2 M 5 M. 7 Mo A I B i PARTIAL FLOOR PLAN - HVAC DEMOLITION Scale: 1 /4"=V-0" Y2" CU TYPE L /r\ 4" nii 'O C�-BYRES 2 PARTIAL FLOOR PLAN - PLUMBING NEW WORK Scale: 1 /4"=V-0" 0 0 NORTH (E) 3" NO —HUB WASTE BELOW FLOOF STRESS ECHO O rZ� 0 NORTH E I F I G I H Phase 1 3 PARTIAL FLOOR PLAN - HVAC NEW WORK Scale: 1 /4"=V-0" 0 0 NORTH SPECIFIC NOTES THIS SHEET: OCONNECT DOMESTIC HOT & COLD WATER SUPPLY TO NEW LAVATORY SINK FIXTURE BELOW FLOOR. FIELD VERIFY EXACT LOCATION. 20 CONNECT NEW LAVATORY SINK WASTE LINE TO EXISTING 3" NO —HUB WASTE LINE IN FLOOR. FIELD VERIFY EXACT LOCATION. 30 EXTEND NEW 1Y2" VENT THROUGH ROOF. SEE DETAIL 1, SHEET MEP1.01. Phase 1 L. MCI CD N N •� �C O O L x LL ' W .N � o •� o G% o N C-,0 • Z3 O � O > 5 C L z N M O N N 9_1 U) U) z o O U w 0 w w D LEI Q 0 6 Z w U U Q � U � � o N J O °' (C) N G U) � L U) �^ VCCJ G O 0 " 3j (N N 0 � z O X O -0 N N � E w w W r- w RECEIVED Sep 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: DRAWN BY: DG RH DATE: APPROVED BY: 7/15/21 DG SCALE: FILE NAME: As Noted MP1.01 PROJECT No: 21146.02 SHEET TITLE: Second Floor Mechanical and Plumbing Plans Phase 1 SHEET NUMBER: M P 1 . 10 U1 1 2 3 0 5 n 7 111 III c F PARTIAL FLOOR PLAN - LIGHTING DEMOLITION3 Scale: 1 /4"=1'—O" NORTH PC3-20 1 .iJ 1 i IP71 I I 1 1 I I REMOVE EXI 1 1 1 `1 WSHP-5 11 78 MCA-480V-3PH P 0 2 PARTIAL FLOOR PLAN - POWER DEMOLITION 04 Scale: 1 /4"=1'—O" NORTH m PARTIAL FLOOR PLAN - LIGHTING NEW WORK rZ� �7 Scale: 1 /4"=1'—O" NORTH 0 PARTIAL FLOOR PLAN - POWER NEW WORK Scale: 1 /4"=1'—O" NORTH THHN+G; T THHN+G; T SPECIFIC NOTES THIS SHEET: OCONDUIT AND CONDUCTORS FOR BRANCH CIRCUITS, IN GENERAL, HAVE NOT BEEN SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL NECESSARY WIRE AND CONDUIT FOR A COMPLETE SYSTEM, HOMERUN FROM FIRST DEVICE TO PANE SHALL BE INDICATED ON AS —BUILT DRAWINGS. 20 REPLACE WITH NEW LED RECESSED LIGHTING FIXTURE PER LIGHTING SCHEDULE. COORDINATE WITH ARCHITECTURAL RCP. 30 DEMO EXISTING 208 VAC OUTLET AND RELOCATE TO NEW LOCATION SHOWN IN NEW WORK. FIELD VERIFY PANEL LOCATION OF OUTLET SERVICE TO STORAGE CLOSET ACROSS THE HALL TO THE EAST OF THE REMODELED SUITE. VERIFY BREAKER SIZE AND REPLACE CONDUCTORS IF NECESSARY TO ACCOMMODATE DEDICATED 20A TREADMILL BRANCH CIRCUIT. 04 PROVIDE WALL MOUNTED SWITCH WITH INTEGRAL OCCUPANCY SENSOR SET FOR 30 MINUTE AUTO OFF AFTER MANUAL SWITCH ON. 50 PROVIDE WALL MOUNTED 0-10V DIMMER SWITCH WITH OCCUPANCY SENSOR. ODATA DROPS TO BE LOCATED IN WALL AT HEIGHT TO BE SPECIFIED BY OWNER. COORDINATE DATA NETWORK CONNECTIONS WITH OWNER IT TECHNICIANS. 70 MOUNT OUTLET AT 40" AFF. Phase 1 Phase 1 I CD ~ U CD_CD y O L Cu LL � v W .ti C o •� o G% o N 0 y a o C > a, W :_ ti (L? ( V;L� N Cl) �U)U) Al z Q o O U w 0 w w D LEI Q 0 6 z __LLj w U U � � U � � o N J O °' (C) N N lb L U) V) G O 0 w 3 (N N 0 � z O Q X O N N N 3 E w w w r w RECEIVED Sep 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGNED BY: DRAWN BY: DG RH DATE: APPROVED BY: 7/15/21 DG SCALE: FILE NAME: As Noted E1.01 PROJECT No: 21146.02 SHEET TITLE: Second Floor Electrical Plans Phase 1 SHEET NUMBER: E1.10