APPROVED BLD-BLD2021-1004+Architectural_Plan+7.18.2021_10.07.28_AM+2306723fM1CL===EoODDDCQSS,__.C�MQ.N R=S.DIENCE, 91 31o 0L Y M P C V W V� DMONDS, WA 90'00200 t ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ (PRESERVATIVE -TREATED LUMBER REQUIRED ALL WOOD ON CONCRETE OR IN DIRECT CONTACT WITH THE GROUND, EXTERIOR (SIDING, SHEATHING AND FRAMING WITH A CLEARANCE LESS THAN 6" TO THE GROUND OR 2" TO CONCRETE SURFACES, ANY WOOD (ATTACHED DIRECTLY TO CONCRETE WALLS BELOW GRADE.NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE , I Hardware and fasteners in contact with preservative -treated wood shall be of ■ ' hot -dipped zinc galvanized steel, I Istainless steel, silicon bronze or copper. .In the absence of manufacturers recommendations a minimum of ASTM A 653 type G185 zinc -coated I galvanized steel, or equivalent, shall be used. ■ L I RC R317.3.1 IBC 2304.10.5.1 I 0 APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE ............................................I"! Install per manufacturers specifications. Have all manufacturer documentation on site. r...............................................' City Of Edmonds Building Department Work DECK Address 9318 OLYMPIC VIEW DR ---------------------------------------- Owner MCLEOD Approved Date 08/04/2021 Building Official lrelt-6111( 610ON416( Permit Number BLD2021-1004 FROJECT TEAM OWNERS MURRAI' MCLEOD/HEATHER G,455ELMAN 9318 OLYMPIC VIEW DR EDMONDS, WA e0020 ARCHITECT TAMRA GROH, AIA 131(o CALIFORNIA AVE SW SEATTLE, WA 98116 PHONE: 206-89m-1529 EMAIL: tam_38(o-IaHOTMAIL.COM CONTRACTOR PORTER HOMES LLC 2-101 229TH PL NE SAMMAMISH, WA cJOO-14 CONTACT: JONATHAN PORTER PHONE: 2mro-941-roro92 EMAIL: MRPORTER206,I@CaMAIL.GOM PROPERTY DATA PROJECT ADDRESS 9318 OLYMPIC VIEW DRIVE ASSESSOR'S TAX NUMBER 0056500101001 LEGAL DESCRIPTION NE 1/4 5EC13 T21N IR3E 6HEET INDEX ARCHITECTURAL A -I COVER SHEET/SITE MAP A-2 GENERAL NOTES A-3 SITE PLAN A-4 DECK FRAMING PLAN/ELEV. A-5 DETAILS RECEIVED Jul 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N Ld O �w �tZ oz CDV) LLJ J Q M O = w j:5 c�0 c~n rn Q q chi rn N _ a a _ o R V a J v 0 a c 0 U c� ,Q 0 �Q z lu 0 o � aZ w Ll U) oLU i o� Q 3 O� UO } W w� DRAWN: TG CHECK: TG JOB NO: SHEET: _ OF: SHEETS GENERAL NOTES 1. ALL WORK TO COMPLY WITH THE ''2018 INTERNATIONAL RESIDENTIAL CODE" (IRC) AND ALL THE SUPPLEMENTS AND AMENDMENTS OF THE LOCAL JURISDICTION. 2. ALL APPLICABLE CODES, ORDINANCES AND MINIMUM STRUCTURAL REQUIREMENTS TAKE PRECEDENCE OVER ALL DRAWINGS, NOTES AND SPECIFICATIONS. 3. CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR ANY DISCREPANCIES IN CONTRACT DOCUMENTS OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK, 4. CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO PROCEEDING WITH WORK. 5. CONTRACTOR TO VERIFY ALL DIMENSIONS, GRADES AND EXISTING CONDITIONS BEFORE PROCEEDING WITH WORK. 6. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF/HERSELF WITH ALL ASPECTS OF THE WORK PRIOR TO CONTRACTING WITH THE OWNER TO PERFORM THE WORK. 7, CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL NECESSARY PERMITS FOR THE WORK, EXCEPT FOR THE BUILDING PERMIT WHICH IS THE RESPONSIBILITY OF THE OWNER. 8. GUARANTEE ON ALL MATERIALS AND WORKMANSHIP TO BE (1) YEAR FROM DATE OF COMPLETION UNLESS NOTED OTHERWISE IN CONTRACT. 9. REPETITIVE FEATURES MAY BE DRAWN ONLY ONCE, BUT SHALL BE PROVIDED AS IF DRAWN IN FULL. REPETITIVE NOTES MAY BE CALLED OUT ONLY ONCE AND INDICATED AS TYPICAL. 10. DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE OR CENTERLINE OF INTERIOR COLUMNS UNLESS NOTED OTHERWISE. 11. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS AND NOTIFYING THE ARCHITECT OF ANY DISCREPANCIES IN FRAMING PRIOR TO PROCEEDING WITH WORK. 12, THESE DRAWINGS ARE DESIGN -BUILD IN THE AREAS OF MECHANICAL, ELECTRICAL AND PLUMBING. JOB SITE SAFETY 1. THE ARCHITECT HAS NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND/OR CONSTRUCTION REVIEW SERVICES RELATING TO THE CONTRACTOR'S SAFETY PRECAUTIONS. 2. PERIODIC SITE VISITS PERFORMED BY THE ARCHITECT SHALL NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION SAFETY PRECAUTIONS. 3. THE ARCHITECT IS NOT RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR OR THE CONTRACTOR'S EMPLOYEES OR EMPLOYEES OF SUPPLIERS OR SUBCONTRACTORS, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL OR OCCUPANCY BY ANY PERSON. SITE WORK 1. ALL EXCAVATION AND FILL SHALL BE STORED AND PROTECTED SUCH AS TO PREVENT RUN OFF OF MATERIAL TO ADJACENT PROPERTIES. 2. FOOTING DRAIN TO BE SEPARATE FROM ROOF AND IMPERVIOUS AREA DRAINS, 3. DOWNSPOUT DRAIN TO BE 4" DIAMETER TIGHTLINE UNLESS NOTED OTHERWISE. 4. FOOTING DRAIN TO BE 4" DIAMETER PERFORATED PIPE UNLESS NOTED OTHERWISE 5. CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH REQUIRED SEEWER AND/OR STORM WATER SYSTEMS. EARTH WORK 1. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING SITE VISITS BY THE GEOTECHNICAL ENGINEER TO VERIFY SOIL CONDITIONS. 2. EXTEND EXCAVATION DOWN TO UNDISTURBED SOIL OF THE SPECIFIED STRENGTH WITH A MINIMUM OF 18" BELOW LOWEST ADJACENT FINISH GRADE, 3. COMPACTED FILL TO BE WELL GRADED AND GRANULAR WITH NOT MORE THAN 5% PASSING A 200 SIEVE. PLACE IN 8" LOOSE LIFTS AND COMPACT TO 9551. MODIFIED AASHO DENSITY AT OPTIMUM MOISTURE CONTENT. 4. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. MOISTURE PROTECTION (SEE IRC R319) I. PROVIDE PRESSURE TREATED PLATES BETWEEN CONCRETE AND FRAMING. 2. PROVIDE A MINIMUM OF 12" CLEAR BETWEEN WOOD GIRDERS AND EARTH. 3. PROVIDE A MINIMUM OF IV CLEAR BETWEEN WOOD JOISTS AND EARTH. 4. PROVIDE A MINIMUM OF 8" CLEAR BETWEEN WOOD POSTS AND EARTH. 5. PROVIDE A MINIMUM OF 1" CLEAR BETWEEN WOOD POSTS AND CONCRETE FLOORS. 6. CAULK ALL OPENINGS THOROUGHLY. -1. FLASH ALL OPENINGS WITH A MINIMUM OF 26 GAUGE GALVANIZED STEEL TO ACCEPTABLE INDUSTRY STANDARDS. 8. METAL COPING AT PARAPET TO BE A MINIMUM OF 22 GAUGE GALVANIZED STEEL. VENTILATION NOTES I. ALL WORK TO COMPLY WITH THE m 150-1 OF THE 2015 SRC. 2. SOURCE SPECIFIC FANS SHALL BE LOCATED IN ALL KITCHENS, BATHROOMS, WATER CLOSETS AND LAUNDRY FACILITIES. VENTILATION CAPACITY SHALL BE AT LEAST 50 G.F.M. FOR BATHROOMS AND LAUNDRY ROOMS (Intermittent use) AND 100 C.F.M. FOR KITCHENS (Intermittent use). DUCTING SHALL TERMINATE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH BACKDRAFT DAMPERS. 3. WHOLE HOUSE VENTILATION SYSTEM SHALL PROVIDE THE VOLUME OF OUTDOOR AIR SPECIFIED BY 1-1150-1.3.30) OUTDOOR AIR SHALL BE PROVIDED TO ALL HABITABLE ROOMS. FAN SHALL HAVE A $ONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE FOR FAN LOCATED LESS THAN 4 FEET FROM GRILL. 4. PROVIDE VENTILATION OPENINGS PER SECTION 150-1.3.4.4, 5. ALL SUPPLY DUCT WORK IN CONDITIONED SPACE SHALL BE INSULATED TO A MINIMUM OF R-4 PER 150-1.3.6.4. 6. PROVIDE A MINIMUM NET AREA OF 1 SQUARE FOOT OF VENTILATION AREA FOR EACH 150 SQUARE FEET OF CRAWLSPACE AREA. PLACE OPENINGS WITHIN 3' OF EACH CORNER .SRC SECTION R408, -1. ALL CRAWLSFACE VENTS TO BE PROVIDED WITH 1/4" NON -CORROSIVE WIRE MESH OR SRC R408.2 APPROVED EQUIVALENT. 8. PROVIDE A MINIMUM NET AREA OF 1 SQUARE FOOT OF FREE VENTILATION AREA FOR EVERY 150 SQUARE FEET OF ATTIC AREA. PROVIDE A CONTINUOUS 1 INCH MINIMUM AIR SPACE ABOVE INSULATION FOR CROSS VENTILATION PER SRC. 9. ALL ATTIC VENTS TO BE PROVIDED WITH 1/4" NON -CORROSIVE WIRE MESH OR APPROVED SOFFIT VENTS. ENERGY NOTES I. ALL WORK TO COMPLY WITH THE "2015 WASH. STATE ENERGY CODE" (WSEC) AND ALL THE SUPPLEMENTS AND AMENDMENTS OF THE LOCAL JURISDICTION. 2, PER WSEC 401.3 AN 15NULATION CERTIFICATE PROVIDED BY THE INSULATOR TO BE POSTED WITHIN 3 FEET OF ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. 3. PRESCRIPTIVE MINIMUM INSULATION VALUES PER WSEC TABLE 402.1.1 UNLESS NOTED OTHERWISE: CEILING R-49 (1" clear vent space) JOIST VAULTED CLG R-38 (1" clear vent space) ABOVE GRADE WALL R-21 BELOW GRADE WALL R-21 (Interior) BELOW GRADE WALL R-10 (Exterior) FLOOR R-30 SLAB ON GRADE R-10 (First 24") 4. PER WSEC R402.4-THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH TEH REQUIREMENTS OF SECTIONS R402.4.1 THROUGH R402.4.4 5. PER WSEC TABLE R402.4.1.1-A CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BUILDING ENVELOPE. EXTERIOR THERMAL ENVELOPE CONTAINS A CONTINOUS AIR BARRIER WITH ALL BREAKS OR JOINTS SEALED. 6. PER SEC R403.1-AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM. -1. PER WSEC R403.3.2-ALL DECTS, AIR HANDLERS AND FILTER BOXES SHALL BE SEALED. 8. PER WSEC R403.5.5-ALL ELECTRIC WATER HEATERS IN UNHEATED SPACES OR ON CONCRETE FLOORS SHALL BE PLACED ON AN INCOMPRESSABLE, INSULATED SURFACE WITH A MINIMUL THERMAL RESISTANCE OF R-10, 9. PER WSEC R403.6- THE BUILDING MUST BE PROVIDED WITH VENTILATION THAT MEETS THE REQUIREMENTS OF THE IRC OR IMC. OUTDOOR AIR INTAKES ADN EXHAUST SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE VENTILATION SYSTEM IS NOT OPERATING. 10. PER R403.6.1 WHOLE -HOUSE MECHANICAL VENITILATION FAN EFFICACY PER TABLE R403.6.1 11. PER WSEC 4031 HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN ACCORDANCE WITH THE ACCA MANUAL S BASED ON TEH BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER APPROVED HEATING AND COOLING CALCULATIONS METHODOLIGIES. 12. PER WSEC R404.1 -MIN OF -15io OF PERMANENTLY INSTALLED NEW LAMPS IN LIGHTING FIXTURES TO BE HIGH -EFFICACY 13. PER WSEC R406.2 - DWELLING SHALL COMPLY WITH TABLE R406.2 TO ACHIEVE A MINIMUM OF 1.5 CREDITS FOR A SMALL DWELLING UNIT. APPLICABLE CREDITS ARE LISTED BELOW AND ON SHEET A-1. OPTION 5a. EFFICIENT WATER HEATING 5a. .05 CREDITS -ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL BE RATED AT 115 GPM OR LESS. -ALL OTHER LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR LESS, OPTION 3d - HIGH EFFICIENCY HVAC EQUIPMENT 3d: 1.0 CREDITS -DUCTLESS SPLIT SYSTEM HEAT PUMP, ZONAL CONTROL: IN HOMES WEHRE THE PRIMARY SPACE HEATING SYSTEM IS ZONAL ELECTRIC HEATING, A DUCTLESS HEAT PUMP SYSTEM SHALL BE INSTALLED AND PROVIDE HEATING TO EH LARGEST ZONE OF THE HOUSING UNIT. FIRE PROTECTION 1. PROVIDE (1) HOUR FIRE SEPARATION BETWEEN GARAGE AND DWELLING UNIT. RESIDENTIAL, DIVISION 3, AND M OCCUPANCY FIRE SEPARATION CONSISTS OF: - (1) LAYER OF 5/8" GYPSUM WALLBOARD ON THE GARAGE SIDE AT ALL WALLS AND AT CEILINGS. PROVIDE (2) LAYERS AT CEILINGS BELOW HABITABLE SPACES. - 1-3/8" MINIMUM THICK, SOLID CORE, TIGHT FITTING, SELF CLOSING DOOR WITH SMOKE GASKET. - DUCTS PIERCING FIRE SEPARATION TO BE A MINIMUM OF 26 GAUGE, AND HAVE NO OPENINGS INTO THE GROUP "U" OCCUPANCY. 2. FIRE SEPARATION TO BE HORIZONTAL AND VERTICAL INCLUDING ALL STRUCTURAL MEMBERS SUPPORTING THE FIRE SEPARATION. 3. ALL ENCLOSED USEABLE SPACE UNDER STAIRWAYS SHALL BE (1) LAYER OF 5/8" TYPE 'X' GYPSUM WALLBOARD ON ENCLOSED SIDE. 4. SMOKE DETECTORS SHALL BE HARD WIRED TO BUILDING POWER AND SHALL HAVE BATTERY BACKUP. 5. SMOKE DETECTORS SHALL BE INTERCONNECTED TO PROVIDE AN AUDIBLE ALARM IN ALL SLEEPING ROOMS. 6, SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM, OUTSIDE EACH SLEEPING ROOM IN THE IMMEDIATE VICINITY, AND A MINIMUM OF (1) SMOKE DETECTOR SHALL BE INSTALLED ON EACH FLOOR INCLUDING THE GARAGE. -1. FIRESTOPPING AND DRAFTSTOPPING SHALL CONSIST OF 2" NOMINAL LUMBER. 8. FIRESTOPPING AND DRAFTSTOPFING IS REQUIRED IN THE FOLLOWING PLACES: - CONCEALED SPACES AT ALL FLOOR AND CEILING LEVELS AND AT 10 FOOT INTERVALS ALONG THE LENGTH OF THE WALL. - INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES (Le. Soffits) - CONCEALED SPACES BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF THE RUN. 9. ROCK WOOL AROUND ALL OPENINGS FOR VENTS, PIPES, DUCTS, ETC. 10. EMERGENCY EGRESS WINDOWS SHALL MEET THE FOLLOWING REQUIREMENTS: CLEAR OPEN WIDTH 20" (Minimum) CLEAR OPEN HEIGHT 24" (Minimum) CLEAR OPEN AREA 51 s.f. (Minimum) SILL HEIGHT 44" (Maximum) 11. PREFABRICATED FIREPLACES SHALL BEAR U.L. OR I.C.B.O. SEAL OF APPROVAL AND SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 12. APPLIANCE GENERATING A GLOW, A SPARK, OR FLAME MAY BE INSTALLED IN THE GARAGE PROVIDED THE HEATING ELEMENTS AND SWITCHES ARE 18" ABOVE THE FLOOR. 13. GARAGE FLOOR TO BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL (CONCRETE). SAFETY AND SECURITY I. DEADBOLTS WITH A MINIMUM THROW OF 1/2" AND A VIEWPORT ARE REQUIRED AT ALL EXTERIOR DOORS. 2. DEADBOLTS OR APPROVED LOCKING DEVICES ARE REQUIRED ON ALL SLIDING DOORS. 3. ALL LOCKS SHALL BE OPENABLE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT. 4. WINDOWS WITHIN 10'-0" OF FINISHED GRADE SHALL BE PROVIDED WITH LATCHING DEVICES. 5. STAIRWAYS SHALL MEET THE FOLLOWING FOR OCCUPANCIES LESS THAN 10: STAIR WIDTH 36" (Minimum clear above the handrails) 31-1/2" (Minimun clear with handrail on one side) 21" (Minimum clear with handrails on both sides) TREAD DEPTH 10" (Minimum) RISER HEIGHT -1-3/4" (Maximum) HEADROOM 50" (Minimum) HANDRAIL HEIGHT 34" to 38" above nosing HANDRAIL DIAMETER 1-1/4"(Min) to 2" (Max), or per IRC R311.5.6.3 (o. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. -1. GUARDRAILS SHALL BE A MINIMUM OF 36" ABOVE FINISH FLOOR. 8. GUARDRAIL INTERMEDIATE MEMBERS SHALL BE CONFIGURED AS TO PROHIBIT PASSING A 4" DIAMETER SPHERE THROUGH ANY OPENING. GLAZING NOTES I. ALL GLAZING TO BE (2) PANE INSULATED GLASS OR BETTER UNLESS NOTED OTHERWISE. 2. SLIDING DOORS TO BE SAFETY GLASS, LAMINATED GLASS, OR TEMPERED GLASS. 3. SHOWER DOORS AND ENCLOSURES TO BE SAFETY GLASS, LAMINATED GLASS, OR TEMPERED GLASS. 4. REFER TO WINDOW SCHEDULE FOR ADDITIONAL REQUIREMENTS. BATHROOM NOTES I. WALL COVERINGS IN SHOWERS TO BE MOISTURE RESISTANT MATERIAL TO -12" (Minimum) ABOVE THE FLOOR. 2. TOILET TO HAVE CLEAR SPACE OF 30" WIDE (Minimum) AND 21" CLEAR (Minimum) IN FRONT OF STOOL. SHOP DRAWINGS I. SHOP DRAWINGS ARE REVIEWED FOR DESIGN INTENT ONLY. 2. THE CONTRACTOR IS TO REVIEW AND APPROVE ALL SHOP DRAWINGS PRIOR TO SUBMITTING TO ARCHITECT OR STRUCTURAL ENGINEER. 3. SEE STRUCTURAL NOTES AND PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND CLARIFICATIONS REGARDING SHOP DRAWINGS. DRAWING LEGEND SYMBOL DESCRIPTION REMARKS OWINDOW SYMBOL See Window Schedule A DOOR SYMBOL See Door Schedule 202 SPACE NUMBER See Finish Schedule O2 GRID LINE A 12 MATCH L INE 40'-8" VERTICAL T.O. Slab DATUM POINT �--�► SURFACE MATERIAL Stone Wood CHANGE DWG SHT DETAIL REFERENCE WG SECTION CUT 11_sNT REFERENCE I INTERIOR 4 SHT 2 ELEVATION See Interior Elevations REFERENCE 3 MATERIAL 5YM50L LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION III=III=III=IIIz El I El 11=III=1 EARTH / COMPACT FILL >< ROUGH WOOD FRAMING 0 GRAVEL / POROUS FILL WOOD BLOCKING a a � a CONCRETE PLYWOOD CMU / BRICK / STONE VENEER FINISH WOOD GYPSUM WALL BOARD / PLASTER GATT INSULATION ?000/0' STEEL OR OTHER METALS RIGID INSULATION NATURAL STONE ABBREVIATION LIST AB ANCHOR BOLT ABV ABOVE AC AIR CONDITIONING ACT ACOUSTICAL TILE ADDT ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AGG AGGREGATE ALT ALTERNATE ALUM ALUMINUM APPR APPROXIMATE ARCH ARCHITECT/ARCHITECTURAL ,45PH ASPHALT BD BOARD BEL BELOW BLDG BUILDING BLK BLOCKING BM BEAM BO BY OTHERS BOF BOTTOM OF FOOTING BOT BOTTOM BOW BOTTOM OF WALL BRG BEARING BSMT BASEMENT BTB BURY THE BODIES BTWN BETWEEN BUR BUILT UP ROOFING CAB CABINET CAP CAPACITY (ATV CABLE TELEVISION CB CATCH BASIN CIF CAST IN PLACE CJ CONTROL JOINT CL CENTER LINE CLG CEILING CLKG CAULKING CLR CLEAR CMU CONCRETE MASONRY UNIT CNTR CENTER CO CLEAN OUT COL COLUMN GONG CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CPT CARPET CRV CONTINUOUS RIDGE VENT CSMT CASEMENT CT CERAMIC TILE CY CUBIC YARD d PENNY D DEEP D DRYER DAFD DON'T ASK FOR DETAIL DBL DOUBLE DCU DON'T CALL US DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DN DOWN DR DOOR IDS DOWNSPOUT (EXTERIOR) DTL DETAIL DW DISHWASHER DWG DRAWING DWR DRAWER E EAST EA EACH EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC ELEV ELEVATION ENCL ENCLOSURE ENG ENGINEER EQ EQUAL EQUIP EQUIPMENT EW EACH WAY EXIST EXISTING EXT EXTERIOR FB FLAT BAR FD FLOOR DRAIN FF FINISH FLOOR FIN FINISH FLASH FLASHING FLR FLOOR FLUOR FLUORESCENT FND FOUNDATION FOC FACE OF CONCRETE FOF FACE OF FINISH FOS FACE OF STUD FRMG FRAMING FT FOOT/FEET FTG FOOTING GA GAUGE GAL GALLON GALV GALVANIZED GFI GROUND FAULT INTERRUPTER GL GLASS GLB GLU-LAMINATED BEAM GR GRADE GWB GYPSUM WALL BOARD GYP GYPSUM H HE IGHT HB HOSE BIBB HC HOLLOW GORE HD HEAVY DUTY HDR HEADER HDWD HARDWOOD HDWR HARDWARE HGR HANGER HORZ HORIZONTAL HR HOUR HT HE IGHT HWT HOT WATER TANK ID INSIDE DIAMETER IDS INTERIOR DOWNSPOUT IN INCH INSUL INSULATION INT INTERIOR JST JOIST JT JOINT KID KILN DRIED LAM LAMINATED LB POUNDS LF LINEAL FOOT LH LEFT HAND LL LIVE LOAD LT L IGHT LTG LIGHTING MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MC MEDICINE CABINET MECH MECHANICAL MEMB MEMBRANE MFR MANUFACTURER MILP MAKE IT LOOK PRETTY MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MTL METAL N NORTH NA NOT APPLICABLE N I C NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE O/ OVER OBSC OBSCURE OC ON CENTER OD OUTSIDE DIAMETER OD OVERFLOW DRAIN OH OVERHEAD OPNG OPENING OPP OPPOSITE FBD PARTICLE BOARD PERF PERFORATED PERP PERPENDICULAR PH PAPER HOLDER PL PLATE FL PROPERTY LINE PLAM PLASTIC LAMINATE PLYWD PLYWOOD FOL POLISHED PR PAIR PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED FTC) PAINTED QT QUARRY TILE QTY QUANTITY R RADIUS R RISER RD ROOF DRAIN REF REFRIGERATOR RE INF REINFORCING READ REQUIRED RH RIGHT HAND RJ ROOF JACK/VENT RM ROOM RO ROUGH OPENING RV RIDGE VENT $ SOUTH SB SETBACK $B SAND BLAST SC SOLID CORE SCHED SCHEDULE SF SQUARE FOOT SHMTL SHEET METAL SHTHG SHEATHING $IM SIMILAR SPECS SPECIFICATIONS $Q SQUARE SS STAINLESS SS STL STAINLESS STEEL STD STANDARD STL STEEL $TOR STORAGE $TRUC STRUCTURAL SV SOFFIT VENT $YM SYMBOL T TREAD TEL TELEPHONE TEMP TEMPERED TEMP TEMPERATURE T 8G TONGUE AND GROOVE THK THICK TO TOP OF TOP TOP OF PLATE TOS TOP OF SLAB TOW TOP OF WALL TV TELEVISION TW TRAIN WRECK TYP TYPICAL UBC UNIFORM BUILDING CODE UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VER VERIFY VERT VERTICAL VG VERTICAL GRAIN W WEST W WATT W WIDTH W/ WITH W/O WITHOUT WD WOOD WP WATERPROOF WR WATER RESISTANT WS WOOD SCREW WT WE IGHT WWM WELDED WIRE MESH YD YARD YM YOUR MOTHER RECEIVED Jul 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (V Ljjaf F o (V O w Ld zp z 5UJ 0 J Q 0.1: o M L,LJ M a 0 N _ aco (Q' o N i � V o a J i 0 U Q� �O H 4Q Z Z� !Y Z lu U ~ Z 0 oUj Y o� s O Jk Ljj Q i VD � } � W mu w� NLi � DRAWN: TG CHECK: TG JOB NO: LOF:SHEET:2 SHEETS (GUARDRAILS SHALL BE MIN. 36" IN HEIGHT .WHERE THE ADJACENT SURFACE OR !GRADE IS 30" OR MORE BELOW. RAILINGS .SHALL BE SPACED TO NOT ALLOW THE !PASSAGE OF A 4" SPHERE. IRC R312.1 0 EXISTING STEPS (o TREADS a 11 -1 RISERS AT -I" ME ME . THERE SHALL BE A FLOOR OR LANDING AT THE ! ! BOTTOM OF EACH STAIRWAY. THE LANDING SHALL BE AT LEAST AS WIDE AS THE STAIRWAY IT SERVES AND 36" IN THE DIRECTION OF TRAVEL. R311.7.6 Landings for Stairways ■ t ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ ■ _ !GUARDRAILS SHALL BE DESIGNED TO RESIST A ■CONCENTRATED LOAD OF 200 POUNDS IN ANY ! DIRECTION AT THE TOP OF THE GUARDRAIL. ■ .INFILL COMPONENTS SHALL BE DESIGNED TO ! !OVER A HORIZONTAL LOAD OF 50 POUNDS ■ A ONE SQUARE FOOT AREA. IRC R301.5. i [DEC< FRAI"IINCz/FLOOR PLAN - GROSS AfP--,,E4 150 SF FLAN1/4 = 1 - ! HANDRAILS ARE REQUIRED AT STAIRS WITH FOUR NORTH■ OR MORE RISERS. ALL HANDRAILS TO BE LOCATED ■ 34" TO 38" ABOVE TREAD NOSING. OPEN SIDES OF ! !STAIRS MORE THEN 30" ABOVE ADJACENT FLOOR ■ !SHALL HAVE HANDRAILS & GUARDRAILS. THE ! ■ HANDGRIP PORTION SHALL HAVE ACROSS !SECTIONAL DIMENSION OF 11/" TO 2". IRC R311.7.8. j UJE5T ELEVATION < NOT 5C��4DULE DE eCfRIf=TION LUS 210 M IAX HANGER TYP ATTACH W/#10 2.5" SIMi=SON STRONG SCREWS 7YP ATTACH 3XIm LEDGER W/ (2)6DWS 5" LAG SCREWS a 16" O.C. TO EXIST. RIM JOIST 7YP - HUG 410 A7 ALL FLU5HMOUN7 BEAMS W/#9 SIMPSON STRONG SCREWS 70P MOUNTED LUS 210 ZMAX HANGER 70 COUNTER UPLIFT. ATTACH W/#10 2B" 5IMF50N STRONG SCREWS 71'P OF 3 JOISTS PROVIDE 6I1"fP50N HI'S FOR POSITIVE CONNECTION BETWEEN PERPENDICULAR DROPPED BEAMS AND JOISTS PROVIDE SIMPSON H2.5 FOR POSITIVE CONNECTION BETWEEN ALL ANGLED DROPPED BEAMS AND JOISTS 2X1O BLOCKING BETWEEN ALL JOISTS U.N.O.-ALL RIMS ARE DOUBLE 2XIO'5 GLUED TOGETHER WITH CONSTRUCTION S ADHESIVE. INSIDE LAYER IS LAGGED INTO JOIST WITH 3.5" SDS SCREWS, AND SECOND RIM IS GLUED TO FIRST AND SCREWED TOGETHER WITH 3.5" SDS SCREWS. NEW DECK IS CONNECTED TO OLD DECK BY ADDING AN EXTRA 2X1O 70 CREATE A TRIPLE RIM JOIST A7 JUNCTURE BETWEEN OLD AND NEW. LAG RIM TOGETHER WITH 5" SDS SCREWS 10 PROVIDE 12" TOP MOUNT LAG SCREW FOR BEAM 70 BEAM CONNECTION BETWEEN ALL FLUSH BEAMS (FB) AND DROPPED BEAMS (DB) I1 TOENAIL DIAGONAL JOISTS TO RIM 12 PICKET STYLE STAIR RAILING -STAINED CEDAR HAND RAIL TO BE 3ro" AS MEASURED FROM THE EDGE OF TREAD NOSING. PICKETS AND RAILS ARE 70 PREVENT A 4" SPHERE FROM PASSING THROUGH. HANDRAIL ON TOP OF GUARDRAIL SHALL BE 1 1/2" IN CROSS -SECTIONAL DIMENSION AND SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. 13 PICKET STYLE GUARD RAILING -STAINED CEDAR 36" GUARDRAIL, PICKETS 70 PREVENT PASSAGE OF A 4" SPHERE. GUARD RAIL TO BE BE DESIGNED TO RESIST A 200LB CONCENTRATED 70P LOAD AND A SOPSF ON ALL INFILL COMPONENTS. 14 GLASS GUARD RAIL 36" TEMPERED GLASS GUARDRAIL GUARD RAIL TO BE BE DESIGNED 70 RESIST A 20OL5 CONCENTRATED TOP LOAD AND A 50P5F ON ALL INFILL COMPONENTS. 15 PRIVACY SCREEN/TRELLIS SCREEN HEIGHT NOT TO EXCEED (o FEET ABOVE FINISHED DECK HEIGHT SCREEN TO BE CEDAR LATTICE WITH BUILT IN GUARD RAIL AT 3ro" ABOVE FINISHED DECK HEIGHT. 16 REMOVABLE DECK AREA AND CONCRETE SLAB BELOW PROVIDED FOR FUTURE HOT 7U5. P7 4XIO FLUSH BEAMS ARE RIMMED INSIDE WITH A P7 2XIO FASTENED FROM THE INSIDE FACE. TEMPORARY DECK AREA IS SUPPORTED INDEPENDANTLY WITH (6) 4X4 POSTS SET ON TOP OF CONCRETE SLAB. 1� DECKING TO BE 1" COMPOSITE DECKING - TIMBERTECH AZEK OR EQUAL ENGL 16H WALNUT TYP. IS PROVIDE WALL MOUNTED EXTERIOR LIGHT WITH MOTION 5EN50RED 70 PROVIDE SUFFICIENT LIGHTING AT TOP OF ALL STAIR LANDINGS. 19 STAIRS RISERS MUST EITHER BE SOLID OR PARTIALLY CLOSED SO THAT OPENING CAN NOT PERMIT THE PASSAGE OF A 4" DIAMETER SPHERE. r•".ra■� NOfRT1-4 ELEVATION '5C,4L -- 1/-411- 1I RECEIVED Jul 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N N C ofC) LLJ LLJ zp ~ z cn LLJ J � Q O a 0 N _ a c6 (Q' o N i V a ■ J � 0) i Q j) _EZ Q 0 U cp c� 00 �Q Z LU Z T F Q w z0 LU W Ld � u0 o w� NU w LLI� N:3 0� N(j) DRAWN: TG CHECK: Tr-z; JOB NO: IN TIM5ERTECH DECKING 2XIm PT DF JOISTS SIMPSON HI TIE W SDS SCREWS - 4X12 PRESSURE TREATED DOUG FIR 5EAM CCQ(oro POST CAP W/ SDS2.5 i=OST TO FOOTING SECTION 1' = 3/4'-0" 0 I N 1'-0' SLA5 SECT ION &X6 PRESSURE TREATED DOUG FIR POST C55Q66 POST BASE WET SET IN CONC W/ SDS2 Hardware and fasteners in contact with ■ preservative -treated wood shall be of hot -dipped zinc galvanized steel, ■ stainless steel, silicon bronze or copper. I In the absence of manufacturers • recommendations a minimum of ASTM A 653 I type G185 zinc -coated galvanized steel, or ■ equivalent, shall be used. I I I RC R317.3.1 IBC 2304.10.5.1 ■ IS' DIA CONC. FOOTING W/ (4) 04 VERT *4 TIES AT 10" OC a a a 7'-7j• I" TIM5ERTECH DECKING 2XIm PT DF JOISTS U SIMPSON HI TIE W SDS SCREWS 4X12 PRESSURE TREATED DOUCs FIR BEAM AC4 POST CAP W/ SDS2 4X4 PRESSURE TREAT DOUG FIR POST A5U44 POST BASE W/ 10" J-50LT EMBED IN 12' DIA CONC. FOOTING W/ (4) *4 VERT 04 TIES AT 10' OC 1'-0' FOST TO FOOTING SECTION 1 " = 3/4' - 0' 1'-6' 0 IN TIM5ERTECH DECKING 2X10 PT DF JOISTS SIMPSON H1 TIE W SDS SCREWS 4X12 PRESSURE TREATED .� DOUG FIR BEAM 'OST CAP W/ 'RESSURE TREATED o FIR POST C5SQ44 POST BASE WET SET IN CON SDS2 2' DIA GONG. FOOTING J/ (4) 04 VERT 6 4 TIES AT 10" OC POST TO FOOTING SECTION 1" = 3/4'-0" IN TIMRF7QTFC!-I nFGIGINrs IT DF JOISTS ESSURE TREATED R BEAM OST CAP W/ :ESSURE TREATED IR POST =06T BASE W/ ELT EMBED IN CONC. REINFORCING POST TO SLA5 SECT ION 1' = 3/4' - 0' PLACE VICOR ON SHEATHING BETWEEN LEDGER AND EXIST. HOUSE FLASHING 4" UP WALL AND OVER NEW LEDGER 3X10 PRESSURE TREATED LEDGER DOUG FIR *12 I' TIM5ERTECH DECKING I LATERAL LOADS SHALL BE ■ TRANSFERRED TO THE GROUND OR THE STRUCTURE THAT IS CAPABILE 6%_11, F TRANSFERRING THE LOAD. PLEASE i REFER TO 2018 IRC R507.9.2 FOR MORE. DETAILS AND REQUIERMENTS. 2X10 PT DF JOISTS LUS 210 ZMAX HANGER TYP ATTACH W/010 2.5" SIMPSON STRONG SCREWS TYP (2)5DW5 5" LAG SCREWS DECK LEDGER DETAIL RECEIVED Jul 21 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N 0 W U pLLJ 0 Ld x LLJ f0 5 w N R Q 2 0 _ N .v A o ® Qu N i � V o a J V p a 0 U 00 �Q LU Z 0 �Z U U' Z 0 lu W s O� Q 3 VO } u1 N 0� w DRAWN: TG CHECK: TG OB NO: SHEET: OF: ) SHEETS