APPROVED_PLN BLD_RESUB1 BLD2021-0777+Mechanical_Plan+9.9.2021_4.07.12_PM+2400873PROJECT STATISTICS
SITE ADDRESS:
PARCEL NUMBER
CODES USED:
LEGAL DESCRIPTION
PROPERTY DESCRIPTION
YEAR BUILT:
ZONING:
NEIGHTBORHOOD CODE:
BUILDING GROSS SQ FT:
PROJECT AREA:
PRESENT USE:
PROPOSED USE:
CONSTRUCTION TYPE:
SPRINKLERS:
PARKING:
PROJECT TEAM
22931 HWY 99 EDMONDS, WA 98026
00576700000205
2018 INTERNATIONAL BUILDING CODE
(STATE OF WASHINGTON AMENDMENTS)
2018 INTERNATIONAL MECHANICAL CODE
2018 WASHINGTON STATE ENERGY CODE
SKELTONS LK MC ALEER 5 ACRE TRS BLK 000 D-05 - LOT 2 LY E OF ST RD
LESS PTN LY N OF ALN WH BEGINS AAP S02*28 02E 317.34FT FR THE INT
OF PRIMARY S/HY NO 1 & E LN SD LOT & EXT S87*56 01 W PLW S LN OF
SD LOT A DIST OF 157.53FT TO SELY HWYR/W LN AKA LOT 2 OF SP
S-39-77 REC AF 7709140278 LESS R/W TO CITY LYNN PER WD REC AF
9712170397
BRENTWOOD PLAZA -COMMERCIAL
1986
EDMONDS CITY
5604000 TOWNSHIP: 27 RANGE: 04 SECTION: 31 QUARTER : NE
13,826 SF.
1,049 SF.
R - RETAIL GROCERY STORE
B - BUSINESS RESTAURANT 35 OCCUPANTS OR LESS
II -A
NO SPRINKLERS
ADEQUATE
DESIGN TEAM: CATCH DESIGN STUDIO
1405 BOYLSTON AVE.
SEATTLE, WA 98122
CONTACT: NOS NARIN
#206.322.4323
E-MAIL: NOS@CATCHSTUDIO.COM
ARCHITECT OF
RECORD: THAN SUTAN
CATCH DESIGN STUDIO
LANDLORD: FIVE CR LLC
PO BOX 33548 SEATTLE, WA 98133
CONTACT: JUN RYU
BEST CHOICE REALTY
15213 29TH DR SE MILL CREEK, WA
#206-200-8668
RESTAURANT
OWNER: IDY CHANG, KAY SAM KO
#206-946-5248
UP20027UP@YAHOO.COM.HK
LEGEND
2424 T-BAR CEILING MOUNT DIFFUSER
DUCT CONNECTOR W/ ADJUSTABLE AIR
FLOW DAMPER
2424 T-BAR CEILING MOUNT
OT
RETURN AIR DIFFUSER
THERMAL STATE
DOWNWARD ROUND DIFFUSER. SIZE
SUPPLY AIR
ACCORDING TO CONNECTED DUCT SIZE
RETURN AIR
SPIRAL DUCT
INSULATED FLEXIBLE DUCT, SIZE PER PLAN
HVAC SYSTEM REQUIREMENTS NOTES:
1. HVAC SYSTEM AND INSTALLATION SHALL COMPLY WITH 2O15 WASHINGTON STATE ENERGY CODE SEC. C403.
2. CONDITIONED AREA OCCUPANT LOAD IS 35, REQUIRED MIN. O.S.A.:350 CFM . PROVIDE 5 TON UNIT WITH TOTAL 710 CFM CAPACITY
3. SYSTEM DUCTS SHALL BE CLASSIFIED AS LOW-PRESSURE DUCT SYSTEM (STATIC PRESSURE LESS THEN OR EQUAL TO 2" W.G. ).
ALL DUCT JOINTS, SEAMS AND CONNECTIONS SHALL BE SECURELY FASTENED AND SEALED WITH APPROVED MASTIC DUCT SEALER.
ALL DUCT AND PIPE INSULATION SHALL BE R-6 MIN. DUCT AND PIPE INSTALLATION AND SEAL SHALL BE COMPLY WITH SEC. C403.2.8
4. HVAC SYSTEM SCHEDULE: (OCCUPANCY GROUP B)
ALL 7 DAYS
9:OOPM -- 9:00 AM SYSTEM OFF;
9:00 AM -- 9:00 PM SYSTEM ON.
5. HVAC SYSTEM CONTROL PER 2015 WSEC C403.2.4
6. ALL SUPPLY AIR DIFFUSERS SHALL EQUIP WITH ADJUSTABLE DAMPER OR LOUVER TO OBTAIN THE EXHAUST RATE PER PLAN.
7. ALL OTHER RELATED PERMIT (ELECTRICAL, GAS LINE, FIRE ALARM AND ANY OTHER PERMIT REQUIRED FOR SYSTEM INSTALLATION)
8. CONNECT BUILDING FIRE ALARM TO NEW HVAC UNIT.
9. MINIMUM MOTORS EFFICIENCY PER WSEC C403.2.10.3 AND TABLE C403.2.3(3)
CONTROL SEQUENCES:
GENERAL
OPERATING SCHEDULES SHALL BE CONFIRMED AND ADJUSTED AS NECESSARY. ALL SETPOINTS SHALL BE ADJUSTABLE.
OPTIMUM START-UP:
SYSTEM SHALL BE STARTED TO ESTABLISH SPACE TEMPERATURE PRIOR TO OCCUPANCY. SCHEDULES SHALL BE CONFIRMED AND
ADJUSTED TO CLIENT'S REQUIREMENTS. DURING THE OPTIMUM START-UP PROCESS, DAMPERS SHALL REMAIN IN FULL RE -CIRCULATION
POSITION.
OCCUPIED MODE :
BASED ON TIME OF DAY SCHEDULE. SYSTEM SHALL MAINTAIN MINIMUM OUTDOOR AIR VENTILATION CFM DURING OCCUPIED MODE
ON CALL FOR HEATING, MINIMUM OUTDOOR VENTILATION CFM SHALL BE MAINTAINED. GAS FIRED SECTION SHALL BE ENERGIZED AS
REQUIRED TO MEET SETPOINT.
UNOCCUPIED MODE : RTU SHALL BE OFF.
UPON FALL IN SPACE TEMPERATURE BELOW 55°F, SYSTEM SHALL BE STARTED WITH DAMPER IN FULL RE -CIRCULATION POSITION. SYSTEM
SHALL OPERATE UNTIL SPACE TEMPERATURE EXCEEDS 60OF
W
z
a
H
W
__
zi
►�
ROOF PLAN
SCALE : 3/16" = V-0"
53'-8"
7'-6"
r- I 1�
L" 17'-711 I<Y 9'-511 UU 25'-10" I<
FLOOR PLAN
SCALE: 1/4" = 1'-01,
HVAC DUCT PLAN
SCALE: 1/4" = V-0"
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
APPROVED BY PLANNING
9/1700? 1
VENTILATION REQUIREMENTS
RATE
OUTDOOR
AREA
AIRFLOW
OUTDOOR
EXHAUST
AREA&USE
AREA
DISTRIBUTION
(#PEOPLE/
POPULATION
AIR RATE
OUTDOOR AIR
RATE
AIRFLOW
AIRFLOW RATE
(NET SF)
EFFECTIVENESS
1000 SQ.FT)
(CFM/PERS
RATE
(CFM)
PROVIDED
(CFM)
ON)
((CFM/ SF)
DINING AREA
322
1
70.0
22.54
7.5
0.18
227.01
250.00
RECEPTION
30
1
5
0.15
5
0.06
2.55
10.00
SERVICE AREA
62
1
30.0
1.86
5
0.06
13.02
15.00
KITCHEN
356
0.7
250.0
MEN'S RR
47
50
WOMEN'S RR
47
50
SUB -TOTAL
275
350
City Of Edmonds
Building Department
-------------- --------------------
Work MECVHANICAL
-------------- - - - -------------------------
Address 22931 HIGHWAY 99
Owner HARVEST WONTON NOODLE
Approved Date: 09/21 /2021
------------------------------------
---------------------------------
Building Official Eris. Carfer
--------------------------
Permit Number
BLD2021-0777
----------------------------
4WATFM
=Z-V � -M �
1405 BOYLSTON AVE.
SEATTLE, WA 98122
TEL. 206.322.4323
FAX. 206.322.9177
E-MAIL:INFO@CATCHSTUDIO.COM
WWW.CATCHSTUDIO.COM
ARCHITECT:
PROJECT TITLE:
HARVEST
WONTON
NOODLE
22931 HWY 99
EDMONDS, WA 98026
SHEET TITLE:
PROPOSED HVAC DUCT PLAN
REVISIONS:
CATCH DESIGN STUDIO
DRAWN: NOS NARIN
CHECKED:
SCALE: AS NOTED
FILE:
RECIIR
---
Sep 09 2021
CITY Z EDMONOS
DEVELOPMENT SERVICES
DEPARTMENT
DATE: 08/26/2021
SHEET#
M 1
I I I
I I III� '
:�•
I
1 �1
�
11ILMAKER Mill
I P� A
��
ow
I
®
NEW W1 •�
RESTROOM
RESTROOM�■
rM111
STEAM11FREEZER
REACHIN
■
Ux
■
_T
DISH
■■■�
1 _
WORK A,
____
CLEAN
TABLE 24,
WASHER
0
,j
EXISTING ROOF STRUCTURE PLAN
SCALE : 1/4" = V-0"
JLAM BEAM 6" x 28"
u -u H.r.r.
SECTION - A
SCALE: 3/8" = V-0"
4VAIVM
=zw � -m a-t;"= � =
1405 BOYLSTON AVE.
SEATTLE, WA 98122
TEL. 206.322.4323
FAX. 206.322.9177
E-MAIL:INFO@CATCHSTUDIO.COM
WWW.CATCHSTUDIO.COM
ARCHITECT:
PROJECT TITLE:
HARVEST
WONTON
NOODLE
22931 HWY 99
EDMONDS, WA 98026
SHEET TITLE:
EXISTING ROOF STRUCTURE PLAN
ELEVATION - A
REVISIONS:
CATCH DESIGN STUDIO
DRAWN: NOS NARIN
CHECKED:
SCALE: AS NOTED
FILE:
DATE: 08/26/2021
SHEET#
M1.2
RTU SPECSHEET: 50ZHC-5 TONS
4Ffirm
=-s � -M wt;w= � =
50ZHC
14 SEER Single Packaged Heat Pump System
with Puron® (R-410A) Refrigerant
Single Phase
2 to 5 Nominal Tons (024-060)
Product Data
A10165
024-048 Size
Al 50067
060 Size
Fig. 1- Unit 50ZHC
Single -Packaged Heat Pump Units with:
• Easy installation design
• Corrosion -proof unit base
• Class leading sound ratings
• Sloped drain for improved indoor air quality
• Scroll compressors
• Front and side service access
• Louvered panel coil protection
• Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air
leakage less than 1.4% at 0.5 in WC. when tested in accordance with
ASHRAE standard 193
Features/Benefits
This unit is a. packaged heat pump for manufactured housing, residential,
and light commercial applications. Factory assembled package is a
compact, horizontal supply and return unit, combining easy installation
and maintenance with efficient performance.
EASY TO INSTALL -The units are lightweight, compact single
package units that are easy to handle. Every size unit has an identical 32
by 51-in. (813 by 1295 mm) footprint to make job site planning simple.
50ZHC: Product Data
Physical Data
4 ifr
turn to the expert_
The efficient design uses less sheet metal and makes this unit lighter than
competitive units. The unit can be easily positioned on the job site with
the hand -holds built into the unit basepan.
AERODYNAMIC FAN BLADE DESIGN reduces overall sound by
up to 3dBA; low as 73dBA.
SERVICE ACCESS -The units are designed to be serviced from both
front and side. Routine maintenance tasks, such as coil cleaning, are
sped up with the multiple side panels design.
CORROSION PROOF UNIT BASE The unit features a tough,
high-tech, single -piece composite material unit base with an integrated
drain. The composite material eliminates the potential problem of rust
and premature replacement which are common with standard metal
pans. Each unit base is sloped to eliminate standing water. This feature
minimizes the amount of standing water inside the unit, which limits
mold and mildew growth.
DURABLE STEEL CABINET The watertight construction and
corrosion -resistant finish will keep it looking like new for years. A
specialized paint treatment process ensures quality protection against the
elements. A compact, low -profile design utilizes a louvered coil
enclosure for maximum protection against hail damage and vandalism.
SCROLL COMPRESSORS Each unit comes standard with a scroll
compressor. Each scroll compressor is hermetically sealed against
contamination to help promote longer life and dependable operation. All
scroll compressors have internal high-pressure and overcurrent
protection.
COIL EFFICIENCY Indoor and outdoor coils are computer designed
for optimum heat transfer and cooling efficiency.
DEFROST SYSTEM The system provides time/ temperature -based
defrost cycles to maintain unit efficiency. This highly reliable system
monitors coil temperature and initiates a defrost cycle only if it is
required. The defrost cycle ends as soon as defrosting is complete.
ACCESSORY ELECTRIC HEATERS -A variety of accessory
electric heaters are available for these units. These heaters are comprised
of a separate heater module mounted on the blower inlet and remote
mounted controls located in the unit control box. Single point electrical
connections are provided for powering both the heater and the unit.
START COLLARS -Start collars are provided with each unit to
provide easy connection to the structure ductwork.
DEPENDABLE COMPONENTS Direct -drive, multi -speed blower
motor is standard on all models.
DIRECT -DRIVE, PSC OUTDOOR -FAN MOTORS are designed to
help reduce energy consumption and provide for cooling operation down
to 40°F (4.4°C). It's high efficiency design ensures high performance
with most duct systems.
REFRIGERANT SYSTEM is designed to provide dependability.
Liquid refrigerant filter driers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full refrigerant charge and
is fully run tested. Refrigerant service connections make checking
operating pressure easier.
UNIT SIZE
024
030
036
042
048
060
NOMINAL CAPACITY (ton)
2
2.5
3
3.5
4
5
SHIPPING WEIGHT (Ib)
312
333
334
388
407
475
(kg)
142
151
152
177
185.
215
COMPRESSOR TYPE
SCROLL
REFRIGERANT
R-410A
REFRIGERANT QUANTITIY (lb)
7.00
7.20
6.30
9.10
7.70
11.5
QUANTITY (kg)
3.18
3.27
2.86
4.13
3.49
5.22
OUTDOOR METERING DEVICE
TXV
Piston
TXV
Piston
ORIFICE ID (in.)
0.049
0.057
0.059
0.070
(MM)
1.245
1.448
1.499
1.778
OUTDOOR COIL
ROWS...FINS(n.
2...20
2...20
2...20
2...20
2...20
2...20
FACE AREA (sq. ft)
9.1
10.2
10.2
13.0
15..5
15.5
OUTDOOR FAN
NOMINAL AIRFLOW (CFM)
2000
2000
2800
3100
3100
3300
DIAMETER (in.)
20
20
20
20
20
20
DIAMETER (mm)
508
508
508
508
508
508
MOTOR HP (RPM)
1/8 (825)
1/8 (825)
1/4 (1100)
1/4 (1100)
1/4 (1100)
1/3 (1100)
INDOOR METERING DEVICE
Piston
TXV
TXV
ORIFICE ID (in.)
0.059
0.059
0.067
0.076
-
(mm)
1.499
1.499
1.702
1.9304
-
INDOOR COIL
ROWS ... FINS/in.
3...12
3...14
3...12
3...14
3...14
3...14
FACE AREA (sq. ft)
4.3
4.3
4.9
4.9
4.9
4.9
INDOOR BLOWER
NOMINAL COOLINGAIRFLOW (CFM)
800
1000
1200
1400
1600
1700
NOMINAL SIZE DxL(in.)
10x8
11x9
11 x9
11x9
11 x9
12x11
(mm)
254 x 203
279 x 229
279 x 229
279 x 229
279 x 229
305 x 279
MOTOR (HP)
1/3
1/3
1/2
1/2
3/4
1
HIGH-PRESSURE SWITCH (psig)
CUTOUT 650 +/- 15
RESET (AUTO) 420 +/- 25
LOW-PRESSURE SWITCH (psig)
CUTOUT
20 +/- 5
RESET (AUTO)
45 +/- 10
RETURN -AIR FILTERS
THROWAWAY (in.)
20x20x1
24x30x1
24x36xl
(MM)
508x508x25
610x762x25
610x914x25
*. Required filter sizes shown are based on the AHRI (Air Conditioning, Heating & Refrigeration Institute) rated airflow ata velocity. of 300 ft/min (91 iti)
for throwaway type or 450 ft/min (137 m) for high capacity type. Recommended filters are 1-in. (25 mm) thick.
50ZHC: Product Data
Base Unit Dimensions--060 I
i O
-41
�- -- -
50ZHC: Product Data
9C
s
Q W
m
LL
--
LL
-- o
K
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
8
Performance Data (cont)
Filter Pressure Drop (IN. W.C.)
A150071
FILTER SIZE
CFM
in. (mm)
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
20X20X1
0.05
0.07
0.08
0.10
0.12
0.13
0.14
00.15
-
-
-
-
-
-
-
-
-
-
(508X508X25)
20X24X1
(508X610x25)
-
-
-
0.08
0.09
0.10
0.11
0.13
0.14
0.15
0.16
-
-
-
-
-
-
-
24X30X1
_
-
-
0.04
0.05
0.06
0.07
0.07
0.08
0.09
0.10
-
-
-
-
-
-
-
(610X762x25)
24X36X1
-
-
-
-
-
-
-
0.06
0.07
0.07
0.08
0.09
0.09
0.10
0.11
0.12
0.13
0.14
(610X914X25)
Accessory Electric Heat Pressure Drop (IN. W.C.)
HEATER kW
CFM
800
1000
1200
1400
1600
1800
2000
2200
5-20
0.033
0.037
0.042
0.047
0.052
0.060
0.067
0.075
Wet Coil Air Delivery*
(Deduct 10 percent for 208 Volt Operation)
230 VOLT HORIZONTAL DISCHARGE
UNIT
SIZE
SPEED
TAP
AIR
DELIVEW
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1
SCFM
933
799
758
707
675
608
549
497
435
394
024
2
SCFM
1016
921
882
854
809
761
711
668
599
552
�_3
SCFM
1079
1041
1003
970
944
909
866
810
764
724
1
SCFM
1052
1018
984
943
914
879
833
795
732
678
030
2
SCFM
1141
1107
1069
1036
1006
974
932
899
856
784
3
SCFM
1246
1213
1181
1144
1108
1078
1043
1015
973
931
1
SCFM
1311
1253
1195
1136
1083
1023
958
895
818
729
036
2
SCFM
1413
1364
1313
1256
1203
1148
1084
1022
969
882
3
SCFM
1571
1525
1473
1423
1364
1313
1261
1210
1156
1090
1
SCFM
1499
1434
1394
1349
1307
1273
1232
1169
1108
1038
042
2
SCFM
1568
1532
1497
1459
1407
1381
1346
1304
1252
1185
3
SCFM
1635
1593
1560
1523
1484
1439
1406
1369
1335
1264
1
SCFM
1657
1625
1590
1554
1517
1486
1448
1417
1381
1340
048
2
SCFM
1707
1673
1644
1614
1586
1549
1515
1479
1449
1407
3
SCFM
1931
1900
1870
1840
1809
1778
1749
1714
1683
1646
1418
1
SCFM
1774
1746
1717
1678
1639
1590
1538.
1492
1461
060
2
SCFM
1857
1820
1784
1752
1720
1671
1625
1579
1532
1509
3
SCFM
2183
2144
2115
2079
2049
2018
1986
1933
1859
1733
*. Air delivery values are based on operating voltage of 230v, wet coil, without filter.or electric heater. Deduct, filter and electric heater pressure drops to obtain static pressure
available for ducting.
t. Standard Cubic Feet per Minute
1405 BOYLSTON AVE.
SEATTLE, WA 98122
TEL. 206.322.4323
FAX. 206.322.9177
E-MAIL:INFO@CATCHSTUDIO.COM
WWW.CATCHSTUDIO.COM
ARCHITECT:
PROJECT TITLE:
HARVEST
WONTON
NOODLE
22931 HWY 99
EDMONDS, WA 98026
SHEET TITLE:
RTU SPECSHEET
REVISIONS:
CATCH DESIGN STUDIO
DRAWN: NOS NARIN
CHECKED:
SCALE: AS NOTED
FILE:
DATE: 08/26/2021
SHEET#
NOTES:
1. Do not operate the unit at a cooling airflow that is less than 350 CFM for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below this
point.
M 2
Harvest Wo nto n
COOLING COIL PEAS
Peaked at Time: M o/H r: 7 / 18
Outside Air: OAD BMB/H R : 70 / 00 / 3
Envelope Loads
kylite Solar
kylite Cond
Roof Cond
Glass Solar
Iris/Door Cond
Wall Cond
Partition/Door
Floor
Adjacent Floor
Infiltration
Sub Total
Internal Loads
Lights
People
Misc
Sub Total
Ceiling Load
Ventilation Load
Adj Air Vans Heat
Dehumi d. Ov Sizing
Oar/Undr Sizing
Exhaust Heat
Sup. Fan Heat
Ret. Fan Heat
Duct Heat Pkup
U nderfir Sup Ht Pkup
Supply Air Leakage
Grand Total
Space
Sens. + Lat.
Btu/h
0
0
0
151298
147
08
0
0
0.00
0
161073
4a04
241000
11610
291904
313
0
0
X
40a00
Total Capacity
ton
M Bh
Main Cig 3.8
4.4
Aux Cig 0.0
0.0
Opt lent 0.0
0.0
Project Name:
Data etName:
Harvest Wonton
TIA E00 1 .TR
Plenum
Sens. + Lat
Btu/h
0
0
01
0
0
17
rArel
1 a074
0
0
1,074
-313
0
X
1 J 04
N et
Percent
Total
Of Total
Btu/h
N
0
0�
0
0�
01
1
151298
34
147
0
840
21
0
0�
0
0�
0.00
0.00
0
01
161791
37
a 308
1
241000
53
11610
4
301978
681
0
0'
-,1 0
-
0
01
0
0
0
0
-84
-1
0
0
0
0;
0
0�
0
0�
0
0�
45a382
100.00 '
System Checksums
By burr n design
M o/H r:
0 / 18
ADB:
71
Space
Percent
Sensible
Of Total
Btu /h
(%)
Envelope Loads
0
0
Skylite Solar
0
0
Skylite Cond
0
0 ;
Roof Cond
151937
48 ;
Glass Solar
- 07
-1
Glass/Door Cond
505
1 ;
Wall Cond
0
0
Partition/Door
0.00
0
Floor
0.00
0.00 ;
Adjacent Floor
0
0
Infiltration
161235
47
Sub Total
Internal Loads
4a04
12
Lights
121000
35
People
1,010
5
Misc
171904
1
Sub Total
91
1 ;
Ceiling Load
0
0 ;Ventilation
Load
0
0
Adj Air Trans Heat
Ovl U ndr Sizing
0
0 ;
Exhaust Heat
OA Preheat Riff.
RA Preheat Riff.
Additional Reheat
U nder fi r Sup Ht Pkup
Supply Air Leakage
34 A 31
100.00 '
Grand Total
COOLING
IL SELECTION
Sens Cap.
Coil Airflow
Enter DBfW BIH R
M Bh
cfm
OF OF
gr/Ib
3.8
11429
70.0 0.3
03.
0.0
0
0.0 0.0
0.0
0.0
0
0.0 0.0
0.0
Leave DBfWBIHR
OF
OF
grAb
53.1
51.2
54.0
0.0
0.0
0.0
0.0
0.0
0.0
HEATING COIL PEAK
M o/H r: Heating Design
AD B : 26
Space Peak Coil Peak Percent
Space Sens Tot Sens Of Total
Btu /h Btu /h (%)
0
0
0.00
0
0
0.00
0
-1 , 377
7.30
0
0
0.00
- a80 0
- a 800
15.15
-1 ,04
-1 ,08
8.03
0
0
0.00
0
0
0.00
0.00
0.00
0.00
0
0
0.00
-4100 3
-51865
31.07
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
-31
0
0
0
-4a378
0
-1 3,00
0
0
80
0
0
0
-18a87
AREAS
Gross
Total
Glass
ft��
Floor
11048
Part
0
Int Door
1
EFI r
0
Roof
11048
0
0
al 1
400
107
21
Et Door
21
0
0
A
0.00
70.44
0
0.00
-1.52
0.00
0.00
0.00
1 00.00
Constant Volume
Cooling
ADB
53.1
Ida Plenum
75.9
Return
75.9
R et/OA
76.0
Fn MtrTD
0.0
Fn BI dTD
0.0
Fn Frit
0.0
Heating
72.8
09.1
00.1
00.8
0.0
0.0
0.0
AIRFLOWS
W
Cooling Heating
Diffuser
1140
1140
Terminal
11429
11429
Main Fan
1 ,40
1 ,49
Sec Fan
0
0
N om lent
275
275
AH U lent
275
275
I nfil
0
0
Min top/Rh
0
0
Return
11429
11429
Exhaust
275
275
Ism Eh
0
0
Auxiliary
0
0
Leakage Darn
0
0
Leakage Ups
0
0
ENGINEERING IN
Cooling Heating
% OA 19.2 10.
fmift, 1.36 1.36
fmiton 377.07
ft"Iton 277.23
Btulhr•ft 43.28 -18.00
No. People 40
HEATING COIL
SELECTION
Capacity
Coil Airflow
Ent
Lvg
MBh
cfm
°F
°F
Main Htg
-18.0
11429
00.8
72.8
Aux Htg
0.0
0
0.0
0.0
Preheat
0.0
0
0.0
0.0
Humidif
0.0
0
0.0
0.0
Opt lent
0.0
0
0.0
0.0
Total
- 1 8.0
TRAC EO 700 v6.3.5 cal cu lated at 0 :08 P M On 0/ 0/ 0 1
Alternative - 1 System Checksums Report Page 1 Of 1
4VAIVM
=ZZ� -=
1405 BOYLSTON AVE.
SEATTLE, WA 98122
TEL. 206.322.4323
FAX. 206.322.9177
E-MAIL:INFO@CATCHSTUDIO.COM
WWW.CATCHSTUDIO.COM
ARCHITECT:
PROJECT TITLE:
HARVEST
WONTON
NOODLE
22931 HWY 99
EDMONDS, WA 98026
SHEET TITLE:
SYSTEM CHECKSUMS
REVISIONS:
CATCH DESIGN STUDIO
DRAWN: NOS NARIN
CHECKED:
SCALE: AS NOTED
FILE:
DATE: 08/26/2021
SHEET#
M3