APPROVED_PLN BLD_RESUB1 BLD2021-0777+Mechanical_Plan+9.9.2021_4.07.12_PM+2400873PROJECT STATISTICS SITE ADDRESS: PARCEL NUMBER CODES USED: LEGAL DESCRIPTION PROPERTY DESCRIPTION YEAR BUILT: ZONING: NEIGHTBORHOOD CODE: BUILDING GROSS SQ FT: PROJECT AREA: PRESENT USE: PROPOSED USE: CONSTRUCTION TYPE: SPRINKLERS: PARKING: PROJECT TEAM 22931 HWY 99 EDMONDS, WA 98026 00576700000205 2018 INTERNATIONAL BUILDING CODE (STATE OF WASHINGTON AMENDMENTS) 2018 INTERNATIONAL MECHANICAL CODE 2018 WASHINGTON STATE ENERGY CODE SKELTONS LK MC ALEER 5 ACRE TRS BLK 000 D-05 - LOT 2 LY E OF ST RD LESS PTN LY N OF ALN WH BEGINS AAP S02*28 02E 317.34FT FR THE INT OF PRIMARY S/HY NO 1 & E LN SD LOT & EXT S87*56 01 W PLW S LN OF SD LOT A DIST OF 157.53FT TO SELY HWYR/W LN AKA LOT 2 OF SP S-39-77 REC AF 7709140278 LESS R/W TO CITY LYNN PER WD REC AF 9712170397 BRENTWOOD PLAZA -COMMERCIAL 1986 EDMONDS CITY 5604000 TOWNSHIP: 27 RANGE: 04 SECTION: 31 QUARTER : NE 13,826 SF. 1,049 SF. R - RETAIL GROCERY STORE B - BUSINESS RESTAURANT 35 OCCUPANTS OR LESS II -A NO SPRINKLERS ADEQUATE DESIGN TEAM: CATCH DESIGN STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 CONTACT: NOS NARIN #206.322.4323 E-MAIL: NOS@CATCHSTUDIO.COM ARCHITECT OF RECORD: THAN SUTAN CATCH DESIGN STUDIO LANDLORD: FIVE CR LLC PO BOX 33548 SEATTLE, WA 98133 CONTACT: JUN RYU BEST CHOICE REALTY 15213 29TH DR SE MILL CREEK, WA #206-200-8668 RESTAURANT OWNER: IDY CHANG, KAY SAM KO #206-946-5248 UP20027UP@YAHOO.COM.HK LEGEND 2424 T-BAR CEILING MOUNT DIFFUSER DUCT CONNECTOR W/ ADJUSTABLE AIR FLOW DAMPER 2424 T-BAR CEILING MOUNT OT RETURN AIR DIFFUSER THERMAL STATE DOWNWARD ROUND DIFFUSER. SIZE SUPPLY AIR ACCORDING TO CONNECTED DUCT SIZE RETURN AIR SPIRAL DUCT INSULATED FLEXIBLE DUCT, SIZE PER PLAN HVAC SYSTEM REQUIREMENTS NOTES: 1. HVAC SYSTEM AND INSTALLATION SHALL COMPLY WITH 2O15 WASHINGTON STATE ENERGY CODE SEC. C403. 2. CONDITIONED AREA OCCUPANT LOAD IS 35, REQUIRED MIN. O.S.A.:350 CFM . PROVIDE 5 TON UNIT WITH TOTAL 710 CFM CAPACITY 3. SYSTEM DUCTS SHALL BE CLASSIFIED AS LOW-PRESSURE DUCT SYSTEM (STATIC PRESSURE LESS THEN OR EQUAL TO 2" W.G. ). ALL DUCT JOINTS, SEAMS AND CONNECTIONS SHALL BE SECURELY FASTENED AND SEALED WITH APPROVED MASTIC DUCT SEALER. ALL DUCT AND PIPE INSULATION SHALL BE R-6 MIN. DUCT AND PIPE INSTALLATION AND SEAL SHALL BE COMPLY WITH SEC. C403.2.8 4. HVAC SYSTEM SCHEDULE: (OCCUPANCY GROUP B) ALL 7 DAYS 9:OOPM -- 9:00 AM SYSTEM OFF; 9:00 AM -- 9:00 PM SYSTEM ON. 5. HVAC SYSTEM CONTROL PER 2015 WSEC C403.2.4 6. ALL SUPPLY AIR DIFFUSERS SHALL EQUIP WITH ADJUSTABLE DAMPER OR LOUVER TO OBTAIN THE EXHAUST RATE PER PLAN. 7. ALL OTHER RELATED PERMIT (ELECTRICAL, GAS LINE, FIRE ALARM AND ANY OTHER PERMIT REQUIRED FOR SYSTEM INSTALLATION) 8. CONNECT BUILDING FIRE ALARM TO NEW HVAC UNIT. 9. MINIMUM MOTORS EFFICIENCY PER WSEC C403.2.10.3 AND TABLE C403.2.3(3) CONTROL SEQUENCES: GENERAL OPERATING SCHEDULES SHALL BE CONFIRMED AND ADJUSTED AS NECESSARY. ALL SETPOINTS SHALL BE ADJUSTABLE. OPTIMUM START-UP: SYSTEM SHALL BE STARTED TO ESTABLISH SPACE TEMPERATURE PRIOR TO OCCUPANCY. SCHEDULES SHALL BE CONFIRMED AND ADJUSTED TO CLIENT'S REQUIREMENTS. DURING THE OPTIMUM START-UP PROCESS, DAMPERS SHALL REMAIN IN FULL RE -CIRCULATION POSITION. OCCUPIED MODE : BASED ON TIME OF DAY SCHEDULE. SYSTEM SHALL MAINTAIN MINIMUM OUTDOOR AIR VENTILATION CFM DURING OCCUPIED MODE ON CALL FOR HEATING, MINIMUM OUTDOOR VENTILATION CFM SHALL BE MAINTAINED. GAS FIRED SECTION SHALL BE ENERGIZED AS REQUIRED TO MEET SETPOINT. UNOCCUPIED MODE : RTU SHALL BE OFF. UPON FALL IN SPACE TEMPERATURE BELOW 55°F, SYSTEM SHALL BE STARTED WITH DAMPER IN FULL RE -CIRCULATION POSITION. SYSTEM SHALL OPERATE UNTIL SPACE TEMPERATURE EXCEEDS 60OF W z a H W __ zi ►� ROOF PLAN SCALE : 3/16" = V-0" 53'-8" 7'-6" r- I 1� L" 17'-711 I<Y 9'-511 UU 25'-10" I< FLOOR PLAN SCALE: 1/4" = 1'-01, HVAC DUCT PLAN SCALE: 1/4" = V-0" ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE APPROVED BY PLANNING 9/1700? 1 VENTILATION REQUIREMENTS RATE OUTDOOR AREA AIRFLOW OUTDOOR EXHAUST AREA&USE AREA DISTRIBUTION (#PEOPLE/ POPULATION AIR RATE OUTDOOR AIR RATE AIRFLOW AIRFLOW RATE (NET SF) EFFECTIVENESS 1000 SQ.FT) (CFM/PERS RATE (CFM) PROVIDED (CFM) ON) ((CFM/ SF) DINING AREA 322 1 70.0 22.54 7.5 0.18 227.01 250.00 RECEPTION 30 1 5 0.15 5 0.06 2.55 10.00 SERVICE AREA 62 1 30.0 1.86 5 0.06 13.02 15.00 KITCHEN 356 0.7 250.0 MEN'S RR 47 50 WOMEN'S RR 47 50 SUB -TOTAL 275 350 City Of Edmonds Building Department -------------- -------------------- Work MECVHANICAL -------------- - - - ------------------------- Address 22931 HIGHWAY 99 Owner HARVEST WONTON NOODLE Approved Date: 09/21 /2021 ------------------------------------ --------------------------------- Building Official Eris. Carfer -------------------------- Permit Number BLD2021-0777 ---------------------------- 4WATFM =Z-V � -M � 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: PROPOSED HVAC DUCT PLAN REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: RECIIR --- Sep 09 2021 CITY Z EDMONOS DEVELOPMENT SERVICES DEPARTMENT DATE: 08/26/2021 SHEET# M 1 I I I I I III� ' :�• I 1 �1 � 11ILMAKER Mill I P� A �� ow I ® NEW W1 •� RESTROOM RESTROOM�■ rM111 STEAM11FREEZER REACHIN ■ Ux ■ _T DISH ■■■� 1 _ WORK A, ____ CLEAN TABLE 24, WASHER 0 ,j EXISTING ROOF STRUCTURE PLAN SCALE : 1/4" = V-0" JLAM BEAM 6" x 28" u -u H.r.r. SECTION - A SCALE: 3/8" = V-0" 4VAIVM =zw � -m a-t;"= � = 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: EXISTING ROOF STRUCTURE PLAN ELEVATION - A REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 08/26/2021 SHEET# M1.2 RTU SPECSHEET: 50ZHC-5 TONS 4Ffirm =-s � -M wt;w= � = 50ZHC 14 SEER Single Packaged Heat Pump System with Puron® (R-410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024-060) Product Data A10165 024-048 Size Al 50067 060 Size Fig. 1- Unit 50ZHC Single -Packaged Heat Pump Units with: • Easy installation design • Corrosion -proof unit base • Class leading sound ratings • Sloped drain for improved indoor air quality • Scroll compressors • Front and side service access • Louvered panel coil protection • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in WC. when tested in accordance with ASHRAE standard 193 Features/Benefits This unit is a. packaged heat pump for manufactured housing, residential, and light commercial applications. Factory assembled package is a compact, horizontal supply and return unit, combining easy installation and maintenance with efficient performance. EASY TO INSTALL -The units are lightweight, compact single package units that are easy to handle. Every size unit has an identical 32 by 51-in. (813 by 1295 mm) footprint to make job site planning simple. 50ZHC: Product Data Physical Data 4 ifr turn to the expert_ The efficient design uses less sheet metal and makes this unit lighter than competitive units. The unit can be easily positioned on the job site with the hand -holds built into the unit basepan. AERODYNAMIC FAN BLADE DESIGN reduces overall sound by up to 3dBA; low as 73dBA. SERVICE ACCESS -The units are designed to be serviced from both front and side. Routine maintenance tasks, such as coil cleaning, are sped up with the multiple side panels design. CORROSION PROOF UNIT BASE The unit features a tough, high-tech, single -piece composite material unit base with an integrated drain. The composite material eliminates the potential problem of rust and premature replacement which are common with standard metal pans. Each unit base is sloped to eliminate standing water. This feature minimizes the amount of standing water inside the unit, which limits mold and mildew growth. DURABLE STEEL CABINET The watertight construction and corrosion -resistant finish will keep it looking like new for years. A specialized paint treatment process ensures quality protection against the elements. A compact, low -profile design utilizes a louvered coil enclosure for maximum protection against hail damage and vandalism. SCROLL COMPRESSORS Each unit comes standard with a scroll compressor. Each scroll compressor is hermetically sealed against contamination to help promote longer life and dependable operation. All scroll compressors have internal high-pressure and overcurrent protection. COIL EFFICIENCY Indoor and outdoor coils are computer designed for optimum heat transfer and cooling efficiency. DEFROST SYSTEM The system provides time/ temperature -based defrost cycles to maintain unit efficiency. This highly reliable system monitors coil temperature and initiates a defrost cycle only if it is required. The defrost cycle ends as soon as defrosting is complete. ACCESSORY ELECTRIC HEATERS -A variety of accessory electric heaters are available for these units. These heaters are comprised of a separate heater module mounted on the blower inlet and remote mounted controls located in the unit control box. Single point electrical connections are provided for powering both the heater and the unit. START COLLARS -Start collars are provided with each unit to provide easy connection to the structure ductwork. DEPENDABLE COMPONENTS Direct -drive, multi -speed blower motor is standard on all models. DIRECT -DRIVE, PSC OUTDOOR -FAN MOTORS are designed to help reduce energy consumption and provide for cooling operation down to 40°F (4.4°C). It's high efficiency design ensures high performance with most duct systems. REFRIGERANT SYSTEM is designed to provide dependability. Liquid refrigerant filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge and is fully run tested. Refrigerant service connections make checking operating pressure easier. UNIT SIZE 024 030 036 042 048 060 NOMINAL CAPACITY (ton) 2 2.5 3 3.5 4 5 SHIPPING WEIGHT (Ib) 312 333 334 388 407 475 (kg) 142 151 152 177 185. 215 COMPRESSOR TYPE SCROLL REFRIGERANT R-410A REFRIGERANT QUANTITIY (lb) 7.00 7.20 6.30 9.10 7.70 11.5 QUANTITY (kg) 3.18 3.27 2.86 4.13 3.49 5.22 OUTDOOR METERING DEVICE TXV Piston TXV Piston ORIFICE ID (in.) 0.049 0.057 0.059 0.070 (MM) 1.245 1.448 1.499 1.778 OUTDOOR COIL ROWS...FINS(n. 2...20 2...20 2...20 2...20 2...20 2...20 FACE AREA (sq. ft) 9.1 10.2 10.2 13.0 15..5 15.5 OUTDOOR FAN NOMINAL AIRFLOW (CFM) 2000 2000 2800 3100 3100 3300 DIAMETER (in.) 20 20 20 20 20 20 DIAMETER (mm) 508 508 508 508 508 508 MOTOR HP (RPM) 1/8 (825) 1/8 (825) 1/4 (1100) 1/4 (1100) 1/4 (1100) 1/3 (1100) INDOOR METERING DEVICE Piston TXV TXV ORIFICE ID (in.) 0.059 0.059 0.067 0.076 - (mm) 1.499 1.499 1.702 1.9304 - INDOOR COIL ROWS ... FINS/in. 3...12 3...14 3...12 3...14 3...14 3...14 FACE AREA (sq. ft) 4.3 4.3 4.9 4.9 4.9 4.9 INDOOR BLOWER NOMINAL COOLINGAIRFLOW (CFM) 800 1000 1200 1400 1600 1700 NOMINAL SIZE DxL(in.) 10x8 11x9 11 x9 11x9 11 x9 12x11 (mm) 254 x 203 279 x 229 279 x 229 279 x 229 279 x 229 305 x 279 MOTOR (HP) 1/3 1/3 1/2 1/2 3/4 1 HIGH-PRESSURE SWITCH (psig) CUTOUT 650 +/- 15 RESET (AUTO) 420 +/- 25 LOW-PRESSURE SWITCH (psig) CUTOUT 20 +/- 5 RESET (AUTO) 45 +/- 10 RETURN -AIR FILTERS THROWAWAY (in.) 20x20x1 24x30x1 24x36xl (MM) 508x508x25 610x762x25 610x914x25 *. Required filter sizes shown are based on the AHRI (Air Conditioning, Heating & Refrigeration Institute) rated airflow ata velocity. of 300 ft/min (91 iti) for throwaway type or 450 ft/min (137 m) for high capacity type. Recommended filters are 1-in. (25 mm) thick. 50ZHC: Product Data Base Unit Dimensions--060 I i O -41 �- -- - 50ZHC: Product Data 9C s Q W m LL -- LL -- o K Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 Performance Data (cont) Filter Pressure Drop (IN. W.C.) A150071 FILTER SIZE CFM in. (mm) 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 20X20X1 0.05 0.07 0.08 0.10 0.12 0.13 0.14 00.15 - - - - - - - - - - (508X508X25) 20X24X1 (508X610x25) - - - 0.08 0.09 0.10 0.11 0.13 0.14 0.15 0.16 - - - - - - - 24X30X1 _ - - 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.10 - - - - - - - (610X762x25) 24X36X1 - - - - - - - 0.06 0.07 0.07 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.14 (610X914X25) Accessory Electric Heat Pressure Drop (IN. W.C.) HEATER kW CFM 800 1000 1200 1400 1600 1800 2000 2200 5-20 0.033 0.037 0.042 0.047 0.052 0.060 0.067 0.075 Wet Coil Air Delivery* (Deduct 10 percent for 208 Volt Operation) 230 VOLT HORIZONTAL DISCHARGE UNIT SIZE SPEED TAP AIR DELIVEW EXTERNAL STATIC PRESSURE (IN. W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1 SCFM 933 799 758 707 675 608 549 497 435 394 024 2 SCFM 1016 921 882 854 809 761 711 668 599 552 �_3 SCFM 1079 1041 1003 970 944 909 866 810 764 724 1 SCFM 1052 1018 984 943 914 879 833 795 732 678 030 2 SCFM 1141 1107 1069 1036 1006 974 932 899 856 784 3 SCFM 1246 1213 1181 1144 1108 1078 1043 1015 973 931 1 SCFM 1311 1253 1195 1136 1083 1023 958 895 818 729 036 2 SCFM 1413 1364 1313 1256 1203 1148 1084 1022 969 882 3 SCFM 1571 1525 1473 1423 1364 1313 1261 1210 1156 1090 1 SCFM 1499 1434 1394 1349 1307 1273 1232 1169 1108 1038 042 2 SCFM 1568 1532 1497 1459 1407 1381 1346 1304 1252 1185 3 SCFM 1635 1593 1560 1523 1484 1439 1406 1369 1335 1264 1 SCFM 1657 1625 1590 1554 1517 1486 1448 1417 1381 1340 048 2 SCFM 1707 1673 1644 1614 1586 1549 1515 1479 1449 1407 3 SCFM 1931 1900 1870 1840 1809 1778 1749 1714 1683 1646 1418 1 SCFM 1774 1746 1717 1678 1639 1590 1538. 1492 1461 060 2 SCFM 1857 1820 1784 1752 1720 1671 1625 1579 1532 1509 3 SCFM 2183 2144 2115 2079 2049 2018 1986 1933 1859 1733 *. Air delivery values are based on operating voltage of 230v, wet coil, without filter.or electric heater. Deduct, filter and electric heater pressure drops to obtain static pressure available for ducting. t. Standard Cubic Feet per Minute 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: RTU SPECSHEET REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 08/26/2021 SHEET# NOTES: 1. Do not operate the unit at a cooling airflow that is less than 350 CFM for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below this point. M 2 Harvest Wo nto n COOLING COIL PEAS Peaked at Time: M o/H r: 7 / 18 Outside Air: OAD BMB/H R : 70 / 00 / 3 Envelope Loads kylite Solar kylite Cond Roof Cond Glass Solar Iris/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total Internal Loads Lights People Misc Sub Total Ceiling Load Ventilation Load Adj Air Vans Heat Dehumi d. Ov Sizing Oar/Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup U nderfir Sup Ht Pkup Supply Air Leakage Grand Total Space Sens. + Lat. Btu/h 0 0 0 151298 147 08 0 0 0.00 0 161073 4a04 241000 11610 291904 313 0 0 X 40a00 Total Capacity ton M Bh Main Cig 3.8 4.4 Aux Cig 0.0 0.0 Opt lent 0.0 0.0 Project Name: Data etName: Harvest Wonton TIA E00 1 .TR Plenum Sens. + Lat Btu/h 0 0 01 0 0 17 rArel 1 a074 0 0 1,074 -313 0 X 1 J 04 N et Percent Total Of Total Btu/h N 0 0� 0 0� 01 1 151298 34 147 0 840 21 0 0� 0 0� 0.00 0.00 0 01 161791 37 a 308 1 241000 53 11610 4 301978 681 0 0' -,1 0 - 0 01 0 0 0 0 -84 -1 0 0 0 0; 0 0� 0 0� 0 0� 45a382 100.00 ' System Checksums By burr n design M o/H r: 0 / 18 ADB: 71 Space Percent Sensible Of Total Btu /h (%) Envelope Loads 0 0 Skylite Solar 0 0 Skylite Cond 0 0 ; Roof Cond 151937 48 ; Glass Solar - 07 -1 Glass/Door Cond 505 1 ; Wall Cond 0 0 Partition/Door 0.00 0 Floor 0.00 0.00 ; Adjacent Floor 0 0 Infiltration 161235 47 Sub Total Internal Loads 4a04 12 Lights 121000 35 People 1,010 5 Misc 171904 1 Sub Total 91 1 ; Ceiling Load 0 0 ;Ventilation Load 0 0 Adj Air Trans Heat Ovl U ndr Sizing 0 0 ; Exhaust Heat OA Preheat Riff. RA Preheat Riff. Additional Reheat U nder fi r Sup Ht Pkup Supply Air Leakage 34 A 31 100.00 ' Grand Total COOLING IL SELECTION Sens Cap. Coil Airflow Enter DBfW BIH R M Bh cfm OF OF gr/Ib 3.8 11429 70.0 0.3 03. 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 Leave DBfWBIHR OF OF grAb 53.1 51.2 54.0 0.0 0.0 0.0 0.0 0.0 0.0 HEATING COIL PEAK M o/H r: Heating Design AD B : 26 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h (%) 0 0 0.00 0 0 0.00 0 -1 , 377 7.30 0 0 0.00 - a80 0 - a 800 15.15 -1 ,04 -1 ,08 8.03 0 0 0.00 0 0 0.00 0.00 0.00 0.00 0 0 0.00 -4100 3 -51865 31.07 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 -31 0 0 0 -4a378 0 -1 3,00 0 0 80 0 0 0 -18a87 AREAS Gross Total Glass ft�� Floor 11048 Part 0 Int Door 1 EFI r 0 Roof 11048 0 0 al 1 400 107 21 Et Door 21 0 0 A 0.00 70.44 0 0.00 -1.52 0.00 0.00 0.00 1 00.00 Constant Volume Cooling ADB 53.1 Ida Plenum 75.9 Return 75.9 R et/OA 76.0 Fn MtrTD 0.0 Fn BI dTD 0.0 Fn Frit 0.0 Heating 72.8 09.1 00.1 00.8 0.0 0.0 0.0 AIRFLOWS W Cooling Heating Diffuser 1140 1140 Terminal 11429 11429 Main Fan 1 ,40 1 ,49 Sec Fan 0 0 N om lent 275 275 AH U lent 275 275 I nfil 0 0 Min top/Rh 0 0 Return 11429 11429 Exhaust 275 275 Ism Eh 0 0 Auxiliary 0 0 Leakage Darn 0 0 Leakage Ups 0 0 ENGINEERING IN Cooling Heating % OA 19.2 10. fmift, 1.36 1.36 fmiton 377.07 ft"Iton 277.23 Btulhr•ft 43.28 -18.00 No. People 40 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -18.0 11429 00.8 72.8 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt lent 0.0 0 0.0 0.0 Total - 1 8.0 TRAC EO 700 v6.3.5 cal cu lated at 0 :08 P M On 0/ 0/ 0 1 Alternative - 1 System Checksums Report Page 1 Of 1 4VAIVM =ZZ� -= 1405 BOYLSTON AVE. SEATTLE, WA 98122 TEL. 206.322.4323 FAX. 206.322.9177 E-MAIL:INFO@CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM ARCHITECT: PROJECT TITLE: HARVEST WONTON NOODLE 22931 HWY 99 EDMONDS, WA 98026 SHEET TITLE: SYSTEM CHECKSUMS REVISIONS: CATCH DESIGN STUDIO DRAWN: NOS NARIN CHECKED: SCALE: AS NOTED FILE: DATE: 08/26/2021 SHEET# M3