REVIEWED BLD BLD2020-1146+Structural_Calculations+10.25.2020_11.30.19_AMNASH & ASSOCIATES
RECEIVED ARCHITECTS
Oct 29 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2020-1146
PLAN 3009
BEAM,
LATERAL
and
SEISMIC
CALCULATIONS
it
EGIRSTERED
.4RGHITEGT
�TATE=OF WASHIN&TON
2015 IBC
OCTOBER 2020
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
NASH & ASSOCIATES
ARCHITECTS
BEAM CALCULATIONS
2015 IBC
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
CLIENT:
NASH&ASSOCIATES
BEAM DESIGN DATA
PROJECT:
ARCHITECTS
PER 2015 IBC
DATE:
NAME:
Roof Loads:
LL 25 #/sf
DL 15 #/sf
Total 40 #/sf
Unless
Noted Otherwise
Floor Loads:
LL 40 #/sf
DL 10 #/sf
Total 50 #/sf
Deck Loads:
LL 60 #/sf
DL 10 #/sf
Total 70 #/sf
Soil: 1500 PSF Min.
Concrete: Per IBC 2015
Masonry: Per IBC 2015
Steel: Per IBC 2015
Wood: Per IBC 2015
Nailing: Per IBC 2015
4" Beam: Douglas Fir #2
fv = 1B0
fb = 900 PSI
E = 1,600,000
6" Beam: Douglas Fir #2
fv = 170
fb = B75 PSI
E = 1,300,000
i
Joists & Hem Fir #2
Rafters: fv = 150
fb = 850 PSI
E = 1,300,000
Glu—Lam Beams:
fv = 240 PSI
fb = 2,400 PSI
(reduced by size factor, CF*KI)
E = 1,800,000
8003 118th
Ave. NE. Kirkland, WA 98033 (425)
828-4117
WWW. NASH—ARCHITECTS. COM
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
MASTER BDRM.
RB-1 Date: 7/30/18
Selection 4x 8 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 1.5 in2 R2= 1.5 in (1.5) DL Defl= 0.03 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span
6.0 ft
Reaction 1 LL
564 # Reaction 2 LL 564 #
Beam Wt per ft
6.17 #
Reaction 1 TL
918 # Reaction 2 TL 918 #
Bm Wt Included
37 #
Maximum V
918 #
Max Moment
1378 '#
Max V (Reduced)
734 #
TL Max Defl
L / 240
TL Actual Defl
L / >1000
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in')
Shear (in')
TL Defl (in)
LL Defl
30.66
25.38
0.06
0.03
12.29
5.32
0.30
0.20
OK
OK
OK
OK
40%
21%
20%
15%
Fb
Values
Reference Values
900
Adjusted Values
1346
Adjustments
CF Size Factor
1.300
Cd Duration
1.15
Cr Repetitive
1.00
Ch Shear Stress
Fv (psi) E (psi x mil) Fc
180 1.6 625
207 1.6 625
1.15
N/A
Cm Wet Use 1.00 1.00 1.00
CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft
Loads Uniform LL: 188 Uniform TL: 300 = A
i9lA]
Uniform Load A
R1 =918 R2=918
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
MASTER BDRM.
RB-2 Date: 7/30/18
Selection 4x 8 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 2.2 in2 R2= 3.4 in2 (1.5) DL Defl= 0.13 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
8.0 ft
Reaction 1 LL
Beam Wt per ft
6.17 #
Reaction 1 TL
Bm Wt Included
49 #
Maximum V
Max Moment
3095 W
Max V (Reduced)
TL Max Defl
L / 240
TL Actual Defl
LL Max Defl
L / 360
LL Actual Defl
847 # Reaction 2 LL 1332 #
1377 # Reaction 2 TL 2153 #
2153 #
1678 #
L/369
L/712
Section in'
Shear(in')
TL Defl in
LL Defl
30.66
25.38
0.26
0.13
27.61
12.16
0.40
0.27
OK
OK
OK
OK
90%
48%
65%
51%
Fb(psi)
Fv(psi)
E(psi x mil).Fc!(psi)
Reference Values
900
180
1.6
625
Adjusted Values
1346
207
1.6
625
CIF Size Factor
1.300
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Par Unif LL Par Unif TL Start _End
188 H = 300 0 5.75
488 1 = 780 5.75 8.0
I
H
R1 = 1377 R2 = 2153
SPAN = 8 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
MASTER BATH & BDRM. #2
R B-3 Date: 7/30/18
Selection 4x 8 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 3.1 in R2= 3.1 in (1.5) DL Defl= 0.04 in
Data Beam Span 5.0 ft Reaction 1 LL 1220 # Reaction 2 LL 1220 #
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Loads
Beam Wt per ft
6.17 #
Reaction 1 TL
1965 # Reaction 2 TL 1965 #
Bm Wt Included
31 #
Maximum V
1965 #
Max Moment
2457'#
Max V (Reduced)
1490 #
TL Max Defl
L / 240
TL Actual Defl
L / 813
LL Max Defl
L / 360
LL Actual Defl
L / > 1000
Section (in')
Shear {ice
TL Defl (in)
LL Defl
30.66
25.38
0.07
0.04
21.91
10.80
0.25
0.17
OK
OK
OK
OK
71%
43%
30%
23%
ro si
ry si
t tpsl x me
rc!(psi)
Reference Values
900
180
1.6
625
Adjusted Values
1346
207
1.6
625
CF Size Factor
1.300
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
CI Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 488 Uniform TL: 780 =A
Uniform_ Load A
R1 = 1965 R2 = 1965
SPAN =5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
BONUS RM.
RB-4 Date: 7/30/18
Selection _4x 8 DF-L #2 Lu = 0.0_Ft
Conditions NDS 2015
Min Bearing Area R1= 1.4 inz R2= 1.4 in (1.5) DL Defl= 0.03 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span
6.0 ft
Reaction 1 LL
525 #
Beam Wt per ft
6.17 #
Reaction 1 TL
858 #
Bm Wt Included
37 #
Maximum V
858 #
Max Moment
1288'#
Max V (Reduced)
686 #
TL Max Defl
L / 240
TL Actual Defl
L / >1000
LL Max Defl
L / 360
LLActual Defl
L / >1000
Reaction 2 LL
Reaction 2 TL
525 #
858 #
Section in')
Shear (inz)
TL Defl (in)
LL Defl
30.66
25.38
0.06
0.03
11.48
4.97
0.30
0.20
OK
OK
OK
OK
37%
20%
19%
14%
Fb(psi)
Fv(psi)
E(psi x mil
Fc i(psi)
Reference Values
900
180:
1.6
625
Adjusted Values
1346
207
1.6
625
CF Size Factor
1.300
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 175 Uniform TL: 280 = A
Uniform Load A ]
1
a
R1 = 858 R2 = 858
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GREAT RM.
B-1 Date: 7/30/18
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions_ NDS 2015
Min Bearing Area R1= 3.9 in2 R2= 2.1 in (1.5) DL Defl= 0.02 in
Data
Beam Span
6.0 ft
Reaction 1 LL
1569 # Reaction 2 LL 962 #
Beam Wt per ft
7.87 #
Reaction 1 TL
2418 # Reaction 2 TL 1337 #
Bm Wt Included
47 #
Maximum V
2418 #
Max Moment
2909'#
Max V (Reduced)
1918 #
TL Max Defl
L / 240
TL Actual Defl
L / >1000
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Attributes
Section in'
Shear in2
TL ❑O in
LL Defl
Actual
49.91
32.38
0.06
0.03
Critical
28.10
13.90
0.30
0.20
Status
OK
OK
OK
OK
Ratio
56%
43%
20%
17%
Values
Adiustments
Fb(psi)
Fv(psi)
E(psi x mil)
Fc!(psi)
Reference Values
900
180
1.6
625
Adjusted Values
1242
207
1.6
625
CF Size Factor
1.200
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
?ds Uniform LL: 240 Uniform TL: 300 = A
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
847 B = 1397 1.5 H = 80 0 1.5
163 1 = 260 0 1.5
I
H
Uniform Load A
Pt loads:
R1 = 2418 R2 = 1337
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GREAT RM.
B-2 Date: 7/30/18
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 4.1 in R2= 3.6 in (1.5) DL Defl= 0.04 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
6.0 ft
Reaction 1 LL
1630 # Reaction 2 LL 1390 #
Beam Wt per ft
7.87 #
Reaction 1 TL
2545 # Reaction 2 TL 2229 #
Bm Wt Included
47 #
Maximum V
2545 #
Max Moment
3836'#
Max V (Reduced)
2308 #
TL Max Defl
L / 240
TL Actual Defl
L / 866
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in3)
Shear (in')
TL Defl (in)
LL Defl
49.91
32.38
0.08
0.04
37.06
16.72
0.30
0.20
OK
OK
OK
OK
74%
52%
28%
22%
Fb(psi)
Fv si
E sl x mil
Fc! si
Reference Values
900
180
1.6
625
Values
1242
207
1.6
625
_Adjusted
CF Size Factor
1.200
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 240 Uniform TL: 300 = A
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
847 B = 1397 1.5 H = 80 1.5 6.0
163 1 = 260 1.5 6.0
_ I l
H
Uniform Load A
Pt loads:
R1 = 2545 R2 = 2229
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GREAT RM./ DINING RM.
B-3 Date: 7/30/18
Selection 5-1/8x 9 GLIB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 1.6 in2 R2= 1.9 in2 (1.5) DL Defl= 0.08 in Recom Camber= 0.12 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
12.0 ft
Reaction 1 LL
743 # Reaction 2 LL 913 #
Beam Wt per ft
11.21 #
Reaction 1 TL
1023 # Reaction 2 TL 1247 #
Bm Wt Included
135 #
Maximum V
1247 #
Max Moment
5260'#
Max V (Reduced)
1189 #
TL Max Defl
L / 240
TL Actual Defl
L / 612
LL Max Defl
L / 360
LL Actual Defl
L / 941
Section (in'}
Shear (in2)
TL Defl (in)
LL Defl
69.19
46.13
0.24
0.15
22.87
6.46
0.60
0.40
OK
OK
OK
OK
33%
14%
39%
38%
Fb (psi)
Fv (psi)
E (psi x mi) Fc! (psi)
Reference Values
2400
240
1.8 650
Adiusted Values
2760
276
1.8 650 _
Cv Volume
1.000
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00 1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 53 Uniform TL: 66 = A
Point LL Point TL Distance
1020 B = 1344 7.0
Uniform Load A
Pt loads: _
R1 = 1023 R2 = 1247
SPAN =12FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
DINING RM.
B-4 Date: 7/30/18
Selection 5-1/8x 10-1/2 GLIB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 4.3 in2 R2= 4.3 in2 (1.5) DL Defl= 0.08 in Recom Camber= 0.12 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span
12.0 ft
Reaction 1 LL
2160 # Reaction 2 LL 2160 #
Beam Wt per ft
13.08 #
Reaction 1 TL
2778 # Reaction 2 TL 2778 #
Bm Wt Included
157 #
Maximum V
2778 #
Max Moment
8335'#
Max V (Reduced)
2373 #
TL Max Defl
L / 240
TL Actual Defl
L / 535
LL Max Defl
L / 360
LL Actual Defl
L / 764
Section in'
Shear 02
TL Defl in
LL Defl
94.17
53.81
0.27
0.19
36.24
12.90
0.60
0.40
OK
OK
OK
OK
38%
24%
45%
47%
1-D (psl�
ry psi)
t ips3 x mu?
rc!
Reference Values
2400
240
1.8
650
Adjusted Values
2760
276
1.8_ _
650
Cv Volume
1.000
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 360 Uniform TL: 450 = A
Uniform Load A
R1 = 2778 R2 = 2778
SPAN =12FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
CVRD. PATIO
B-5 Date: 7/30/18
Selection (2) 1-3/4x 18 1.9E TJ Microllam LVL Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 9.9 in2R2= 10.1 in (1.5) DL Defl= 0.20 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Beam Span
15.0 ft
Reaction 1 LL
4549 # Reaction 2 LL 4551 #
Beam Wt per it
16.19 #
Reaction 1 TL
7437 # Reaction 2 TL 7585 #
Bm Wt Included
243 #
Maximum V
7585 #
Max Moment
28035'#
Max V (Reduced)
6046 #
TL Max Defl
L / 240
TL Actual Defl
L / 444
LL Max Defl
L / 360
LL Actual Defl
L / 877
Section (W)
Shear On')
TL Defl (in)
LL Defl
189.00
63.00
0.40
0.21
118.89
27.67
0.75
0.50
OK
OK
OK
OK
63%
44%
54%
41%
Fb(psi)
Fv(psi)
E(psi x mil
Fc E(psi)
Reference Values
2600
285
2.0
750
Adjusted Values
2830
328
2.0
750
CF Size Factor
0.946
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 120 Uniform TL: 150 = A
Point LL Point TL Distance Par Unif LL Par Unif TL Start 1 nd
1220 B = 1965 2.0 488 H = 860 0 2.0
1200 C = 1965 7.0 488 1 = 860 7.0 15.0
I
0
�11 Uniform Load A
Pt loads: `ol ICZLI
R1 = 7437 R2 = 7585
SPAN =15FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
KITCHEN
B-6 Date: 7/30/18
Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 6.7 in2 R2= 4.3 in (1.5) DL Defl= 0.06 in Recom Camber= 0.09 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiusttnents
Beam Span
6.0 ft
Reaction 1 LL
2878 # Reaction 2 LL 1963 #
Beam Wt per ft
6.83 #
Reaction 1 TL
4369 # Reaction 2 TL 2787 #
Bm Wt Included
41 #
Maximum V
4369 #
Max Moment
6642'#
Max V (Reduced)
3344 #
TL Max Defl
L / 240
TL Actual Defl
L / 535
LL Max Defl
L / 360
LL Actual Defl
L / 930
Section (ins)
Shear (in2) TL Defl (in)
LL Defl
42.19
28.13 0.13
0.08
28.88
18.17 0.30
0.20
OK
OK OK
OK
68%
65% 45%
39%
Fb(psi)
Fv sI)
E(psi x mil
Fc I si
Reference Values
2400
240
1.8
650
Adjusted Values
2760
276
1.8
650
Cv Volume
1.000
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 400 Uniform TL: 500 = A
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
1220 B = 1965 2.5 488 H = 860 0 2.5
H
Uniform Load A
Pt loads:
R1 = 4369 R2 = 2787
SPAN =6FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
B-7
Selection
Conditions
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
DEN/ GUEST RM.
Date: 7/30/18
(2) 1-3/4x 18 1.9E TJ Microllam LVL
Lu = 0.0 Ft
NDS 2015
Min Bearing Area
R1= 2.1 in
R2= 6.4 in (1.5) DL Defl=
0.12 in
Beam Span
17.5 ft
Reaction 1 LL
975 #
Reaction 2 LL 2813 #
Beam Wt per ft
16.19 #
Reaction 1 TL
1574 #
Reaction 2 TL 4767 #
Bm Wt Included
283 #
Maximum V
4767 #
Max Moment
14198'#
Max V (Reduced)
4103 #
TL Max Defl
L / 240
TL Actual Defl
L / 853
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in')
Shear (in')
TL Defl (in)
LL Defl
189.00
63.00
0.25
0.13
60.21
18.78
0.88
0.58
OK
OK
OK
OK
32%
30%
28%
21%
Fb(psi)
Fv si
E(psi x mil
Fc I si
Reference Values
2600
285
2.0
750
Adjusted Values
2830
328
2.0
750
CF Size Factor
0.946
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 53 Uniform TL: 66 = A
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
1224 B = 2008 14.0 H = 80 14.0 17.5
1024 C = 1634 14.0 175 1 = 280 14.0 17.5
0
Uniform Load A
Pt loads:
R1 = 1574 R2 = 4767
SPAN =17.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BearnChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
DEN/ GUEST RM,
B-8 Date: 7/30/18
Selection 3-1/8x 9 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 2.0 in2 R2= 6.4 in (1.5) DL Defl= 0.05 in Recom Camber= 0.08 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
6.0 ft
Reaction 1 LL
771 # Reaction 2 LL 2582 #
Beam Wt per ft
6.83 #
Reaction 1 TL
1297 # Reaction 2 TL 4186 #
Bm Wt Included
41 #
Maximum V
4186 #
Max Moment
5773'#
Max V (Reduced)
3844 #
TL Max Defl
L / 240
TL Actual Defl
L / 687
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (ire')
Shear (W)
TL Defl its}
LL Defl
42.19
28.13
0.10
0.05
25.10
20.89
0.30
0.20
OK
OK
OK
OK
59%
74%
35%
26%
Fb (psi)
Fv (Psl) I. (psi x mtl
Fc! si)
Reference Values
2400
240
1.8
650
Adjusted Values
2760
276
1.8
650
Cv Volume
1.000
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Point LL Point TL Distance Par Unif LL Par Unif TL Start_ End
2813 B = 4767 4.5 360 H = 450 4.5 6.0
H
Pt loads:
R1 = 1297 R2 = 4186
SPAN = 6 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
CVRD.PORCH
B-9 Date: 7/30/18
Selection 4x 10 DF-L #2 V _Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 2.5 inz R2= 1.7 in2 (1.5) DL Defl= 0.07 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
8.0 ft
Reaction 1 LL
934 # Reaction 2 LL 590 #
Beam Wt per ft
7.87 #
Reaction 1 TL
1549 # Reaction 2 TL 1042 #
Bm Wt Included
63 #
Maximum V
1549 #
Max Moment
4588'#
Max V (Reduced)
1446 #
TL Max Defl
L / 240
TL Actual Defl
L / 678
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in')
Shear (in')
TL Defl (in)
LL Defl
49.91
32.38
0.14
0.07
44.33
10.48
0.40
0.27
OK
OK
OK
OK
89%
32%
35%
25%
Fb(psi)
Fv(psi)
E(psi x mil
Fc!(psi)
Reference Values
900
180
1.6
625
Adjusted Values
1242
207
1.6
625
CIF Size Factor
1.200
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
1174 B = 2090 3.5 100 H = 125 0 3.5
H
Pt loads:
R1 = 1549 R2 = 1042
SPAN = 8 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GARAGE
GB-1 Date: 7/30/18
Selection (2) 1-3/4x 18 1.9E TJ Microllam LVL Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 9.0 in2 R2= 9.0 in (1.5) DL Defl= 0.05 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Ad1uslments
Beam Span
10.0 ft
Reaction 1 LL
4340 # Reaction 2 LL 4340 #
Beam Wt per ft
16.19 #
Reaction 1 TL
6756 # Reaction 2 TL 6756 #
Bm Wt Included
162 #
Maximum V
6756 #
Max Moment
16890'#
Max V (Reduced)
4729 #
TL Max Defl
L / 240
TL Actual Defl
L / >1000
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in')
Shear (in{)
TL Defl (n)
LL Defl
189.00
63.00
0.11
0.06
71.63
21.64
0.50
0.33
OK
OK
OK
OK
38%
34%
22%
18%
Fb(psi)
Fv(psi)
E(psi x mil
Fc(psi)
Reference Values
2600
285
2.0
750
Adjusted Values
2830
328
2.0
750
CF Size Factor
0.946
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 380 Uniform TL: 475 = A
Par Unif LL Par Unif TL Start End
H = 80 0 10.0
488 1 = 780 0 10.0
1 1
H i
Uniform Load A
R1 = 6756 R2 = 6756
SPAN =10FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GARAGE
GB-2 Date: 7/30/18
Selection 7x 18 2.0E TJ Parallam W.S. PSL Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 18.4 in2R2= 18.4 in (1.5) DL Defl= 0.30 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
19.0 ft
Reaction 1 LL
8844 # Reaction 2 LL 8844 #
Beam Wt per ft
39.38 #
Reaction 1 TL
13788 # Reaction 2 TL 13788 #
Bm Wt Included
748 #
Maximum V
13788 #
Max Moment
58041 '#
Max V (Reduced)
11764 #
TL Max Defl
L / 240
TL Actual Defl
L / 345
LL Max Defl
L / 360
LL Actual Defl
L / 625
Section (W)
Shear (in')
TL Defl (in)
LL Defl
378.00
126.00
0.66
0.36
218.47
52.91
0.95
0.63
OK
OK
OK
OK
58%
42%
70%
58%
Fb(psi)
Fv(psi)
E(psi x mil
Fc I(psi)
Reference Values
2900
290
2.2
750
Adjusted Values
3188
334
2.2
750
CF Size Factor
0.956
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Uniform LL: 360
Uniform TL: 450 = A
Point LL
Point TL
Distance
Par Unif LL Par Unif TL
Start
End
2196
B = 3560
5.0
488 H = 860
0
5.0
428
C = 829
5.0
488 1 = 860
14.0
19.0
2196
D = 3560
14.0
80 J = 100
5.0
14.0
428
E = 829
14.0
J
H
Uniform Load A
Pt loads:
R1 = 13788 R2 = 13788
SPAN =19FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3009
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GARAGE
GB-3 Date: 7/30/18
Selection 5-1/8x 12 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 2.2 inz R2= 2.2 in2 (1.5) DL Defl= 0.13 in Recom Camber= 0.20 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Beam Span
16.0 ft
Reaction 1 LL
828 # Reaction 2 LL 828 #
Beam Wt per ft
14.94 #
Reaction 1 TL
1449 # Reaction 2 TL 1449 #
Bm Wt Included
239 #
Maximum V
1449 #
Max Moment
5715'#
Max V (Reduced)
1434 #
TL Max Defl
L / 240
TL Actual Defl
L / 716
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section (in)
Shear (ink
TL Defl (in)
LL Defl
123.00
61.50
0.27
0.13
24.85
7.79
0.80
0.53
OK
OK
OK
OK
20%
13%
34%
25%
Fb (psi)
Fv(psi)
E (psi x rail)
Fc!(psi)
Reference Values
2400
240
1.8
650
Adjusted Values
2760
276
1.8
650
Cv Volume
1.000
Cd Duration
1.15
1.15
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
CI Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Point LL Point TL Distance Par Unif LL Par Unif TL Start End
428 B = 829 3.0 80 H = 100 3.0 13.0
428 C = 829 13.0
H
Pt loads:
R1 = 1449 R2 = 1449
SPAN =16FT
Uniform and partial uniform loads are Ibs per lineal ft.
1 :j Act: [KIiIly:
BeamChek v2016 licensed to: Nash Jones Anderson Architects Reg # 6464-622
GARAGE
GP-1 Prepared by: Date: 7/30/18
Selection (4) 2x 6 DF-L #2 Nailed Built -Up Wood Column
Conditions NDS 2015, Using values for 2x and 4x solid sawn, Dimension Lumber.
Laminate built-up nailed columns per NDS 15.3.3.1 or per local code.
Data Load 20534 # Column Area 33.0 in Kf 1.00
Actual Height 9.0 ft le d1 Effective Ht 108 in c 0.80
Unbraced L1 9.0 ft le d2 Effective Ht 108 in KcE 0.30
Unbraced L2 9.0 ft Ke Buckling Mode 1.0 FcE 1246
Affributes anti Valdes Controlling d is 5.5 inches Fc 11 (psi) E (psi x mil)
le/d
psi
Area (in')
Actual
20
622
33.0
Critical
50
981
20.93
Status
OK
OK
OK
Ratio
40%
63%
63%
Reference Values
Adjusted Values
1350 1.6
981 1.6
CF Size Factor
1.10
Cd Duration
1.15
Cm Wet Use
1.00 1.00
Cp Stability
0.57
Note: A wood plate under this column must have an Fc value, perpendicular to the grain, greater than 622 psi.
NASH & ASSOCIATES
ARCHITECTS
LATERAL & SEISMIC
CALCULATIONS
2015 IBC
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
:PAJRCHITECTS
CLIENT:
H&ASSOCIATES
7
WIND AND SEISMIC DESIGN DATA
PROJECT:
PER 2015 IBC
DATE:
NAME:
WIND DESIGN CRITERIA
DESIGN PER ASCE 7-10
I. NOMINAL/ULTIMATE WIND SPEED V/asd / Vult 85/110 mph
2. RISK CATEGORY II 1.00
3. WIND EXPOSURE CATEGORY "B"
4. INTERNAL PRESSURE COEFFICENT +/-55
5. COMPONENTS AND CLADDING
DESIGN PRESSURE +/— 16 psf
BUILDINGS, STRUCTURES, AND PARTS THEREOF SHALL BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD, AND RESISTANCE
FACTOR DESIGN, ALLOWABLE STRESS DESIGN, EMPIRICAL DESIGN OR CONVENTIONAL
CONSTRUCTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER, SECTION 1604.1
BUII.DINGS, STRUCTURES, AND PARTS THEREOF, SHALL BE DESIGNED TO WITHSTAND WIND LOADS
AS DEFINED IN SECTION 1609 AND ASCE 7-10
SIMPLIFIED METHOD TO BE USED FOR WIND DESIGN PER ASCE 7-10, SECTION 27.5
BUILDING HEIGHT IS LESS THAN 160 FEET)
110 MPH ULTIMATE WIND SPEED
USE 19.6 PSF PER TABLE 27.6.1 "EXPOSURE B"
WOOD DESIGN PER SECTIONS 2304-2306. STRUCTURES USING WOOD SHEAR WALLS
AND DIAPHRAGMS TO RESIST WIND, SEISMIC, AND ALL OTHER LATERAL LOADS SHALL
BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AF & PA SDPWS AND PROVISIONS
OF SECTIONS 2305-2306
SEISMIC DESIGN DATA
DESIGN PER ASCE 7-10/SECTION 1613
1. SEISMIC IMPORTANCE FACTOR Ie 1.00
2. SHORT PERIOD ACCELERATION Ss 1.66 *see footnote at bottom of page
3. 1 SECOND ACCELERATION S 1 0.748 *see footnote at bottom of page
4. SITE CLASS D (default class per IBC)
5. SPECTRAL RESPONSE COEFFICIENT S w 0.972 *see footnote at bottom of page
6. SPECTRAL RESPONSE COEFFICIENT S m 0.748 *see footnote at bottom of page
7. SEISMIC DESIGN CATEGORY D
8. SEISMIC FORCE RESISTING SYSTEM PLYWOOD SHEAR WALLS
9. DESIGN BASE SHEAR (see seismic calculations)
10. SEISMIC RESPONSE COEFFICIENT CB 0.13
11. RESPONSE MODIFICATION FACTOR R 6.5
12. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
13. RISK CATEGORY II
THE ANCHORAGE OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE
DESIGNED IN ACCORDANCE WITH ASCE 7-10, SECTION 12.11.2
IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C—F, COLLECTOR ELEMENTS
AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RESIST
MAXIMUM EFFECTS AS SPECIFIED IN ASCE 7-10, SECTION 12.10.2.1
BASE SHEAR V= (F SDS /R) W
ANCHOR BOLTS: 5/8" DIA X 10", A307 OR BETTER W/ 7" MIN. EMBEDMENT. V= 1104#/BOLT
• PER USGS, THE MAXIMUM IS IN THE STATE OF WASHINGTON IS 0.748. ALL SEISMIC DESIGN VALUES USED
IN THIS ANALYSIS ARE BASED UPON THIS NUMBER. SINCE, S IS LESS THAN 0.75, THEN USE SEISMIC CATEGO
D IF RISK CATEGORY IS 1, II, OR 111
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
w1w
FRONT ELEVATION
R16HT ELE\/ATION
14.6 p5f
IG.6 psf
B
A
HOLDDONN SCHEDULE
MARK
HOLDONN/
STRAP
FASTENERS
Y�kO MEWBt
THICKNESS/5PECIE5
ANCHOR
REQUIRED
T-1
STHDI4/14 RJ
24-16d SINKER
(2) 2X4/2 X& STUDS
HF/SPF
T-2
MST48
(34)-16d
(2) 2X4/2X6 STUDS
HF/5PF
T-3
MSTA36
(26)-IOd
(2) 2X4/2X6 STUDS
HF/SPF
T-4
MSTr-4BB3
(38)-IOd
HF/SPF
T-5
j HD-!B
(5)- 3/4"
3-I/2" MIN.
vF/SP
SSTB2B (-f/B")
MIN. 24--1/B"
EMBEDMENT
Fy 7S
MAIN FLOOR
18�
10.5 � J
B A
m
HOLDDOWN SCHEDULE
MARK
.0 MEMBER
ANCHOR
STRAP
THILKNESS/SPEGIES
REp Jl
T-1
STHDI4/14 RJ
24-1&d SINKER
7:2/ 2X4/2X6 STUBS
HF/SPF
T-2
MST45
(54)-16d
(2) 2X4/2Xb STUBS
HF� F
T-3
MSTA36
(26)-IOd
(2) 2X4/2X& STUDS
HF/5PF
T-4
MSTG48B3
(38)-IOd
HF/SPF
T-5
HD-IB
�)_ 3/4
MIN.
OF/SP
S5TB28 (7/8"7
MIN. 24-7/95"
EMBEDMENT
---- .IJ 1
UPPER PLOOR
2a.5�
21�
CLIENT:
NASH&ASSOCIATES
LATERAL
DESIGN DATA
PROJECT:
PER IBC 2015
DATE:
;ARCHITECTS
NAME:
1
SHEAR
UNIT
SHEAR
LINE
LEVEL
TOTAL SHEAR FORCE (#)
WALL
SHEAR
WALL
LENGTH (ft)
(#/ft)
TYPE
W
H
P
Abv.
A
2
25
x
6.5
x 19.6
+ 0 = 3185
14.5
219.7
P1-6"
1
25
x
10.5
x 19.6
+ 3185 = 8330
18.5
450.3
P1-2"
B
2
25
x
6.5
x 19.6
+ 0 = 3185
34
93.7
-
1
25
x
10.5
x 19.6
+ 3185 = 8330
42
198.3
P 1-6"
1
2
11
x
6.5
x 19.6
+ 0 = 1401.4
29.5
47.5
-
1
11
x
10.5
x 19.6
+ 1401.4 = 3665.2
18
203.6
P1-6"
2
2
20.5
x
6.5
x 19.6
+ 0 = 2611.7
21.5
121.5
-
1
20.5
x
10.5
x 19.6
+ 2611.7 = 6830.6
37
184.6
P 1-6"
3
2
11.5
x
6.5
x 19.6
+ 0 = 1465.1
21
69.8
-
1
11.5
x
10.5
x 19.6
+ 1465.1 = 3831.8
10.5
364.9
P 1-3"
8003
118th
Ave. NE.
Kirkland, WA 98033
(425) 828-4117
WWW. NASH-ARCHITECTS. COM
5HEAR AALL 5GHr=:%LF-
PER 2015 1 BG
GENERAL NOTES:
SEE PLANS TO DETERMINE THE DIFFERENT DE516NATORS FOR SHEAR WALL MATERIALS,
NAILING, ANCHOR BOLTS, AND HOLDOWN5. LOCATE HOLDOWN5 AS CLOSE AS P055113LE TO THE END
OF THE DE516NATED WALL.
ALL HOLDOWN5, ANCHOR BOLTS, WA5HER5, 8 NAILS IN CONTACT WITH P.T. WOOD TO BE
HOT DIPPED &ALVANIZED.
PI = ONE SIDE PLYWOOD
P2 = TWO SIDES PLYWOOD
NAIL 5PAGIN6 5 SILL OPTIONAL BASE HEM FIR #
.
MARK �/I6" _ TOP BTM. ANCHORS BLKG. PLATE 51MP50N MASAP PLATE
VALUE
PLYWD. EDGES FIFi D PLATES g N1 REO'D. ANCHOR BOLT5 ANGHOR5 NAILING
(#/LF)
PI-6" Sd 6" 12" 6" 18" O.G. 2x4 5/8" ® 48" ® 48" 4 ENDS (2) Ibd ® 10"
240
PI-4" 8d 4" 12" 4" I6" O.G. 2x4 5/8" ® 32" ® 50" 4 ENDS (2) Ibd ® 7"
344
PI-3" **
8d
3"
12"
39
14" O.G.
(2) 2x4/6
5/8" ® 24"
® 24" 4 ENDS
(2) Ibd ® 5"
450
PI-2" **
ad
2"
12"
2"
12" O.G.
(2)2 X4/6
3/4" ® 24"
® 18" 4 ENDS
(2) 16d ® 5"
585
P2-6" **
8d
6"
12"
6"
loll O.G.
(2) 2x4/6
5/8" ® 24"
N/A
(2) Ibd ® 5"
480
P2-4" **
8d
4"
12"
4"
8" O.G.
(2) 2x4/6
3/4" ® 20"
WA
.(3) 16d ® 5"
700
P2-3" **
8d
3"
12"
3B
8" O.G.
(2) 2x4/6
3/4" ® 16"
WA
(4) Ibd ® 5"
c100
P2-2" ** 8d 2" 12" 2" 8" O.G. (2) 2x4/6 3/4" ® 12" N/A (4) 16d ® 4"
1170
**NOTE: WALL5 WITH UNIT SHEAR OF 350#/ft. OR GREATER SHALL HAVE FRAMING
MEMBERS (STUDS $ PLATES) ABUTTING PANELS NOT LE55 THAN 3X MEMBERS OR (2) 2X MEMBER5
PER IBG 2015 AND 5DPW5-2008
PER SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC, CHAPTER
4.3.7.1 #4 EXPEGTION; (2) 2X MEMBERS ARE OK IN LIEU OF 3X
MEMBERS
STITCH NAIL DOUBLE STUDS AND PLATES TOGETHER WITH
16d NAILS ® 12" O.G. 5TA6ERRED ON THE STUD FACE
I. USE POWER -DRIVEN STEEL STUDS AND NAILS BY HILTY OR RAMSET WHERE APPLICABLE.
2. PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY.
3. 50LID BLOCK WITH JOIST UNDER INTERIOR SHEAR WALLS.
SHEAR WALL NOTES
7/16" 05B OR PLYWOOD SHEATHING - USE 8d COMMON OR GALVANIZED NAILS. BLOCK ALL PANEL
EDGE5. LONG DIMENSIONS OF PLYWOOD MAY BE INSTALLED VERTICALLY. NAIL ® 12" O.G. TO ALL
INTERMEDIATE STUDS. WHERE 3" NAIL 5PAGIN6 IS SPECIFIED AT PANEL EDGE5, USE 1-1/2" 8d
SHORT NAILS OR 3X STUDS WITH 8d COMMON NAILS. FOR 2" NAIL 5PAGIN6, USE 3X STUDS
AND 5TA66ER PANELS. WHERE PLYWOOD 15 2 SIDES OF WALL, JOINTS TO FALL ON
SEPARATE STUDS ON EACH SIDE.
FLOOR PLYWOOD - USE 8d COMMON NAILS ® 10" O.G. AT INTERMEDIATE SUPPORTS, 6" O.G.
AT ALL PANEL EDGES AND 4" O.G. AT ALL SHEAR WALL5, UNLESS OTHERN15E 5HOWN ON PLANS.
FLOOR JOISTS - JOIST PARRALLEL TO FLOOR OPENINGS AND EXTERIOR WALLS SHALL BE
GRO55 BLOCKED AT 48" O.G. ® EDGE5 W/ (4) IOd NAILS FOR THE FIRST BAY.
3" x 3" x 1/4" SGUARE WASHERS AT ALL ANCHOR BOLTS. PLATE WASHERS TO BE INSTALLED WITHIN
1/2" OF SHEATHING
7/I6" 055 OR PLYWOOD SHEATHING - STAPLE SCHEDULE
ALLOWABLE SHEAR VALUES WITH HEM FIR #2 STUDS
2" 16 &A. STAPLES ® 15 6A. 5TAPLE5 ® 14 &A. STAPLES
3" O.G. - 280 #/ft. 4" O.G. - 280#/ft. 4" O.G. - 303#/ft.
2" O.G. - 360#/ ft. 2-1/2" O.G. - 430#/ft. 3" O.G. - 3q0#/ft.
4" O.G. AND IOd NAILS 2" O.G. - 504#/ft.
® 6" O.G. - 620#/ft.
FIELD 5PAGIN6: 12" O.G. NAILS 8 STAPLES.
HOLDOWN5 - INSTALL 51MP50N HOLDOWNS OR U5P HOLDOWN5 AT THE END OF SHEAR WALLS
WHEN 5HOWN ON DRAWINGS.
PER PLAN, SIMP50N 5THD14 OR U5P STAD14 SIMPSON M5T36 OR U5P M5TI36
51MP50N M5T48 OR U5P K5T248 5IMP50N HDUB OR U5P TDXIO 06" ANCHOR BOLT MIN.
SIMP50N M5TG48B3 OR U5P MSTG54B3 24" EMBEDMENT, 3" BOLT INTO (3) 2x4(6))
CLIENT:
NASH & ASSOCIAM
SEISMIC ANALYSIS
PROJECT:
PER IBC 2015
DATE:
ARCHITECTS
NAME:
Weight of Building:
Roof Assembly
Asphalt Shingles -
Felt -
1/2" Plywood -
Trusses ® 24" o.c.
R-38 Insulation -
1/2" GWB Ceiling -
2.00 #/it
0.15 #/It
1.50 #/ft
- 1.75 #/ft
2.35 #/ft
2.00 #/ft
Cedar Shakes -
Felt -
1/2" Plywood -
Trusses ® 24" o.c.
R-30 Insulation -
1/2" GWB Ceiling -
2.25 #/ft
0.15 #/ft
1.50 #/ft
- 1.75 #/ft
2.25 #/ft
2.00 #/ft
Tile - 9.50 #/ft
Felt - 0.15 #/ft
1/2 Plywood - 1.50 #/ft
Trusses ® 24" o.c. - 1.75 #/ft
R-30 Insulation - 2.25 ##/ft
1/2" GWB Ceiling - 2.00 #/ft
Total
Use
9.75 #/ft
10.00 #/ft
Total
Use
9.90 #/ft
10.00 ##/ft
Total 17.90 #/ft
Use 18.00 ##/ft
1st & 2nd Floor Assembly.
Caret / Pad -
0.50 #/ft
Hardwood -
2.50 #/ft
3/4' T&G Plywood -
2x10 ® 16o. c. -
1/2" GWB Ceiling -
2.50 #/ft
2.30 #/ft
2.00 #/ft
3/4" T&G Plywood
2x10 0 16" o.c- -
1/2" GWB Ceiling -
- 2.50 #/ft
2.30 #/ft
2.00 #/ft
Total
Use
7.30 #/ft
10.00 #/ft
Total
Use
9.30 #/ft
10.00 ##/ft
Interior Wall Assembly
Exterior Wall Assembly.
1/2" GWB -
2X4 ® 16" o.c. -
1/2" GWB -
Total
Use
2.00 #/ft
1.10 #/ft
2.00 #/ft
5.10 #/ft
8.00 ##/ft
3/4" Wood Siding -
1/2" Plywood -
2x6 @ 16" o.c.
R-21 Insulation
1/2" GWB -
Total
Use
2.30 #/ft
1.50 #/ft
1.37 #/ft
2.10 #/ft
2.00 #/ft
9.27 #/ft
10.00 #/ft
4" Brick Veneer -
+ 3.20 #/ft
8003
118th Ave. NE. Kirkland, WA 98033 (425)
828-4117
WWW. NASH-ARCHITECTS.
COM
NASH - ASSOCIATES
ARCHITECTS
SEISMIC ANALYSIS
PER IBC 2015
3
Wdl
Cs V
LEVEL 2:
28.7
x
0.13
=
3.7
LEVEL 1:
53.8
x
0.13
=
7
TOTAL:
82.5
x
0.13
=
10.7
CLIENT:
PROJECT.
DATE:
NAME:
DEAD LOAD
MOMENT
SHEAR @ STORY
REMARKS
LEVEL
(Wdl)
HIGHT (h)
(Wdl)(h)
Fx = [(Wdl)(h)]V /
[(Wdl)(h)]
ALPHA I NUMERIC
2
28.7
18
516.6
52%
5.56
21
2.8
31
1.9
1
53.8
9
1 484.2
48%
5.14
TOTAL
j 82.5
1 1000.8
100%
10.7
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
NASH & ASSOCIATES SEISMIC ANALYSIS
ARCHITECTS PER IBC 2015
CLIENT:
PROJECT:
DATE:
NAME:
LEVEL
LINE
LINE
LINE
SHEAR
TOTAL
P > 1
WALL
Vmax
SEISMIC (3/ft)
WIND
WALL
OVER
TURNING
SHEAR
SHEAR
ABOVE
LENGTH
V / 1.4
SHEAR
RIGHT
FORCE
WALL
2
A
2.81
0
2.8
14.5
193
138
219.7
8.08
1775.176
P 1-6"
B
2.8
0
2.8
34
82
59
93.7
8.08
757.096
1
1.9
0
1.9
29.5
64
46
47.5
8.08
383.8
2
1.9
0
1.9
21.5
88
63
121.5
8.08
981.72
3
1.9
T-1-9
21
90
64
69.8
8.08
563.984
LEVEL
LINE
LINE
LINE
SHEAR
TOTAL
P > 1
WALL
Vmax
SEISMIC (3/ft)
WIND
WALL
OVER
TURNING
SHEAR
SHEAR
ABOVE
LENGTH
V / 1.4
SHEAR
RIGHT
FORCE
WALL
1
A
2.6
2.8
5.4
18.5
292
209
450.3
9
4052.7
P1-2"
B
2.6
2.8
5.4
42
129
92
198.3
9
17847
P1-6"
1
1.7
1.9
3.6
18
200
143
203.6
9
1832.4
P1-6"
2
1.7
1.9
3.6
37
97
69
184.6
9
1661.4
P1-6"
3
1.7
1.9
3.6
10.5
343
245
364.9
9
3284.1
P1-3"
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH-ARCHITECTS. COM