FIR2021-0028+Fire_Alarm_Equipment_Specification_Sheets+3.24.2021_10.36.48_AM+2108987Model 5204 Fire Alarm Control Panel and Optional Digital Communicator Silent Knight's 5204 is compact and easy to install and service, delivering features you'd expect to find in systems costing much more. The Silent Knight Model 5204 Fire Alarm Control Panel is a local fire evacuation control panel designed for applications requiring manual and automatic fire alarm as well as water flow and sprinkler supervisory service. Description The basic 5204 unit offers local fire alarm control for up to four zones and central station communications with the optional UL Listed Model 5205 Digital Communicator. The 5204 provides 3 amp current for external devices and two 1.5 amp supervised notification circuits. The system is compatible with both 2- and 4-wire smoke detectors. The 5204 includes an annunciator inside the cabinet for annunciation and operation. LEDs are visible without opening the cabinet. Operation keys include SILENCE, DIALER RESET, and DISPLAY TROUBLES. Remote annunciation is available through the optional Model 5230. This four -wire annunciator can perform the same operation as the main system annunciator and features English -language LCD display. Features • The 4 Class B zones are interchangeable to Class A using the Model 7181 Zone Converter. • Fuseless design reduces service calls. • Field selectable 24 or 12 VDC power supply. • 3 amp current output available for external devices. • Compatible with 2- and 4-wire smoke detectors as well as water flow and sounding devices. • Two 1.5 amp supervised notification circuits programmable for steady, pulsing, temporal or supervisory • Auxiliary outputs of 1.5 amp at • 12 or 24 VDC and 175 mA at 12VDC (only) • Smoke verification, pre -alarm delay and cross -zoning minimize false alarms. • Two general purpose relays (2.5A dry contact, Form C) • Optional plug-in UL Listed digital communicator (Model 5205) • Up/downloading (reduces installation time) • Programmable from on -board touchpad or optional remote annunciator (Model 5230) • Accu-ZoneTm diagnostics for on - site troubleshooting. Specifications Electrical Specifications: Primary AC: 120 VRMS @ 60 hz, 2.5A Total Accessory Load: 3A @ 12 or 24 VDC Notification Circuits: Two Class B 1.5A @ 12 or 24 VDC. Programmable for steady, pulsing, temporal and supervisory for sprinkler system supervision. 5204 Auxiliary Outputs: 1.5A @ 12 or 24 VDC 175 mA @ 12VDC Mechanical Specifications: Dimensions: 14-7/8"W x 15-5/8"H x 4-1 /4"D (37.8 x 49.8 x 10.6 cm) Color: Red Telephone Requirements: Type of Jack: RJ31X (2 required) Approvals: UL 864 NFPA 72 -Central Station Reporting -Local Protective Signaling System -Auxiliary Signaling System -Remote Signaling FCC Part 68 and Part 15 CSFM: 7165-0559:117 New York City: MEA 429-92-E SILENT 13. KNIGHT Model 5204 Fire Alarm Control Panel and Optional Digital Communicator Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control system. The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, alarm notification devices and visual annunciators. An optional digital communicator shall transmit fire alarm, trouble and supervisory signals to a central station. The controller shall be UL Listed for use under NFPA 72 standards. It shall provide power and control for four supervised detection zones, 2 supervised notification circuits, and, optionally, an approved plug-in digital communicator. The controller shall be Silent Knight 5204 or equivalent. There shall be four Class B detection zones. Products of combustion detection may be either 2- or 4-wire and shall be cross - listed by UL for use on the system. The detection zones shall be programmable to (1) be cross zones so that two adjacent detectors must sense products of combustion, (2) automatically reset a detector to verify that smoke exists, and (3) see a single detector in alarm%before an alarm is sounded, and, optionally, transmit a signal to the central station. There shall be two 1.5 amp supervised alarm notification circuits. They shall cause the bells/horns to ring steady/pulsing/ temporal through the premises until reset or silenced. The control shall be equipped with two auxiliary relays that shall be programmable to operate on (1) alarm, (2) trouble, (3) supervisory, (4) supervisory trouble and (5) system trouble. The relays shall maintain contact until cleared. The control shall have one on -board touchpad and shall support 3 remote annunciators. LEDs shall augment the display to clarify the system status to an operator. An integral touchpad shall be provided to operate, set up and interrogate the system. The optional plug-in digital communicator shall be UL Listed for use under NFPA 72 standards. It shall have the capability to supervise two telephone lines, seize the phone line and send the alarm signal on one or both lines without additional equipment. It shall be able to communicate to a central station in SIA, SK FSK (4/2), SK4/2 tone burst, SK 3/1, SESCOA 3/1, Radionics BFSK. The communicator shall sound a local trouble signal if the telephone service is interrupted for longer than 45 seconds and it shall transmit a signal indicating restoral of phone service. The optional digital communicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program within the communicator. The alarm signals transmitted to the central station shall indicate which zones are in alarm and which zones are in trouble. Restoral from an alarm shall also be transmitted by zone. Optional Accessories 5230 Remote Annunciator Performs all the same functions as the on -board annunciator and features an LCD English -language display and backlighting. 5205 Digital Communicator Performs all the same functions as the on -board annunciator and features LCD English -language display and backlighting. 5211 Auxiliary Relay Enables ground start phone lines 4180 Status Display Module Provides 16 outputs to give alarm and trouble conditions by zone. Can be used to drive LED or graphic annunciators. Non - supervised. 7181 Fire Zone Converter Converts Class A zones to Class B and vice versa. SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com 5220 Direct Connect Module Used for city box and polarity reversing direct wire applications. 5541 Downloading Software and 5530 Modem For remote programming of 5204 and other Silent Knight products using an IBM PC or compatible computer. MADE IN AMERICA FORM# 350778. Rev. 4/98 Copyright © 1998 Silent Knight 4,�� SYSTEM Photoelectric Smoke Detectors System Sensor i3- series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features • Plug-in detector line, mounting base included Large wire entry port • In -line terminals with SEMS screws • Mounts to octagonal and single -gang back boxes, 4-square back boxes, or direct to ceiling • Stop -Drop 'N Lock attachment to base • Removable detector cover and chamber • Built-in remote maintenance signaling Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Wide-angle, dual -color LED indication • Loop testing via EZ Walk feature • Built-in test switch Agency Listings & F M X MEA MSFMWs LISTED APOapproved approved c 5911 3011446 7272-1653:152 290-01 " 313C93? Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installerto pre -wire bases (included with heads). The large wire entry port and in -line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED - indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent -per -foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of -sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (-L3) Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single -gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non -polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 NA maximum average; 4-wire: 50 NA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 uA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 1207 (0°C to 49°C); 2WT-B and 4WT-B: 327 to 1007 (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non -condensing Thermal Sensor 1357 (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only:417 (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting LED Modes 3'/2-inch octagonal back box 4-inch octagonal back box Single -gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No Wiring Alarm Current 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter f_ SYSTEM �/ SENSOR m2cha System Sensor. 3825 Ohio Avenue • St. Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09latest version okhisdata sheet. A06-0318-007.6/09•#2169 Edwards Signaling Catalog ► Conventional Initiating Edwards Signaling Rate - of- rise/Fixed Temperature Heat Detectors 280B-PL Series Overview 280B-PL Series heat detectors offer fixed temperature or combi- nation rate -of -rise and fixed temperature detection. RATE -OF -RISE: A temperature increase at the sensor of 15°F (9°C) or more per minute activates the rate -of -rise feature. This closes the contacts in the sensor to transmit the alarm condition to the fire alarm control panel. When the rate -of -rise element alone has been activated, the sensor is self -restoring. FIXED TEMPERATURE: If the temperature of the center disk rises to the sensor's rated temperature, the fixed temperature element activates. This closes contacts in the sensor and trans- mits an alarm condition to the fire alarm control panel. The fixed temperature element is non -restorable and, when activated, the detector must be replaced. The need for replacement is indicated when the center disk has fallen free from the detector . Y Standard Features • UL listed for 50 ft. (15.2m) spacing • Single pole — normally open contact • Low profile with mounting plate • Pure white finish • Mounting flexibility with screw terminals • Easy twist -on installation • On -site testing of rate -of -rise feature • Positive operating indication — for fixed temperature element Application Heat detectors are most suitable for environments where rapid fire development can be expected. When selecting the location on the ceiling for the heat sensor, do not locate it in direct path of hot or cold air flow. Refer to the detector specifications for the recom- mended maximum spacing. Earlier detector response may be obtained by reducing the spacing between detectors. Installation Edwards 280B series heat sensors come standard with a white plastic reversible mounting plate. The plate is designed for surface or flush mounting and installs directly to a standard North Ameri- can 31/2 or 4 inch octagon box. Once the mounting plate is fixed, a simple twist will lock the sensor in place. It can be removed using a screwdriver to release the tamper -resistant locking finger. This helps prevent unauthorized removal. Page 1 of 2 DATA SHEET S85001-0261 Not to be used for installation purposes. Issue 4 Mounting C'ow�►Ros Contact us... Phone: 1-800-336-4206 Web: www.edwardssionaling.com Edwards Signaling is an EDWARDS brand. 3 Farm Glen Boulevard Farmington, CT 06032 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. WARNING — Use For Property Protection Only: Heat sen- sors do not protect life against fire and smoke. In most fires, hazardous levels of smoke, heat and toxic gases can build up before a heat detector would initiate an alarm. Independent studies indicate that heat detectors should only be used when property protection alone is involved. In cases where life safety is a factor, the use of smoke detectors is recommended. The plastic mounting plate is molded to accommodate exposed wiring. 2 LOCKING FINGERS SURFACE FLUSH SURFACE MOUNTING MOUNTING MOUNTING SIDE /SIDE Q HOLES (,I) 5' SURFACE (722mm) MOUNT 2 SNAP -OUTS FOR WIRE o O ENTRANCE . 4 I— FLUSH MOUNT. 2U32" BREAK AWAY 2 SECTIONS (52mmf FRONT VIEW ON CIRCUMFERENCE Plastic Reversible Mourning Plate Cat. No. 280A-P1_ Specifications TO INSTALL DETECTOR — MATCH ARROWS ON DETECTOR AND MOUNTING ELECTRICAL BOX PLATE, PUSH UP AND TURN (NN %Pviw) CLOCKWISE. w + T 1-13132' ±m, LIFTREMOVE DETECTOR — Flush MmM LIFE LOCKING FINGER WITH Cun,luN Wiring SCREW DRIVER TIP AND TURN DETECTOR COUNTER- CLOCKWISE FRONT VIEW Mete)Mw, WPlele PM—MPL (o,ae. Sewm+eN) Catalog Number 281B-PL 282113-PL 283B-PL 284113-PL UL Temperature Rating 135°F (57°C) 194°F (90°C) 135°F (57°C) 194°F (90°C) UL Max Ambient Temp. at 100°F (38°C) 150°F (66°C) 100°F (38°C) 150°F (66°C) Ceiling Fixed Temperature and Rate -of - Detector Type Rise Rate -of -rise: Fixed Temperature Only 15' F (9° C), self restoring UL Recommended Cover 2,500 ft.2 (232 m2) age* UL Recommended Spacing 50 ft. (15.2 m) FM Recommended Spacing 30 ft. (9.14 m) UL Maximum Distance from 25 ft. (7.6m) from any wall or projection extending down from the Wall ceiling more than 12 inches (305 mm) Contacts — Rating Single Pole Normally Open 3.0 amps at 6 to 125 Vac; 1.0 amp at 6 to 24 Vdc; 0.3 amps at 125 Vdc; 0.1 amps at 250 Vdc Operating Environment Indoor — Dry Agency Listings I UL, FM, CSFM * Maximum detector coverage has been determined by UL to provide detection time equal to sprinkler devices spaced at 10 ft (3.05m) intervals on a smooth ceiling 15 feet 9 inches (4.8m) high. Higher ceilings may adversely affect detection time. Earlier detection may be obtained by reducing the spacing between sensors. (See NFPA 72, Chapter 5) Under no circumstances should heat detectors be relied upon as the sole measure to ensure fire safety. However, if they are spaced in accordance with the directions in the Specifica- tions table, these sensors can contribute, within an overall Ordering Information fire safety program, to reducing the risk of avoidable properly losses. Ship Wt. Cat. No. Description Ib (kg) 281 B-PL Heat Detector, 135°F (57°C), Rate -of -Rise and Fixed Temperature 282B-PL Heat Detector, 194°F (90oC), Rate -of -Rise and Fixed Temperature 1.0 (0.5) 283B-PL Heat Detector, 135°F (57°C), Fixed Temperature 284B-PL Heat Detector, 194°F (90oC), Fixed Temperature Detector Accessories 280A-PL Plastic Mounting Plate —White, Reversible (included) Page 2 of 2 DATA SHEET S85001-0261 Not to be used for installation purposes. Issue 4 FIRESWITCH FireSwitch108 Managed NAC Power Extender Description Altronix FireSwitch108 Networked NAC Power Extender adds greater flexibility and capac- ity to your system. Eight (8) Class B NACs are individually programmable for Aux. power or up to Four (4) Class A outputs. FireSwitch generates CO Temporal Code 4, compatible with GentexD, Potter and System Sensor® signals. Selectable EOL resistor values simplify retrofits. Programmable LCD display interface and an ethernet port interface for remote programmability and monitoring add to flexibility and conveneince. flow Gon+Y Yroc - Power outputs are programmable as: - 8 Class B NAC outputs; - 4 Class A NAC outputs; - Aux. power outputs (with or without battery backup); - Any combination of the above. - Local and remote status monitoring (LCD display/Ethernet port). - EOL resistor value is programmable by output. - Temporal Code 3, Steady Mode and Input to Output Follower Mode. MAltronix@1 FireSwitch - CO Temporal Code 4 (NFPA720) include Gentex®, Potter and System Sensor® devices. - Thermal and short circuit protection with auto reset. - Signal circuit trouble memory - quickly locates intermittent system trouble and eliminates unnecessary service calls. - Synchronize up to twelve (12) FireSwitch108 units. - UL Listed in the U.S. and Canada for Fire Alarm Systems. - California State Fire Marshall Approved. LINQTm Dashboard with FireSwitch Management Interface: I ItronixRRESWITCH ..xary a,,. l+wn flnrn.w-an a�Ytc+.wti 1 G�z 1 iurrr wirF IFi LYr7 �� Ew� Ifs ] plmpd� - md iYY'rYlW+ fi 51d4W9"-1K 11� kA ! i�!!YNI.L- IWfrl �W ki ! cooft l +WM W ■4�1� IYA %Y 01, � Li XX�W b1iW �A Sum Rev. FireSwitch108-08022017 FIRESWITCH QD FireSwitch108 Managed NAC Power Extender %JjJG\il 1 IVC1LIV1 IJ Input Voltage 120VAC 60Hz, 4.8A. FACP Two (2) Class A or two (2) Class B. Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits (polarity reversal) or dry contacts. Outputs Voltage 24VDC regulated power -limited NACs. Current 10A max total alarm current. 7A max stand-by without battery back-up. 1A with battery back-up including Aux. output (0.45A for Canadian applications). Auxiliary One (1) rated at 1A (regulated, battery backed -up) (0.45A for Canadian applications). Other Any NAC can be configured as an Aux. output, with or without battery backup. Programmable supervised indicating circuit options; Eight (8) Class B, four (4) Class A or any combination of Class A, Class B or Aux power. Back-up Battery Type Sealed lead acid or gel type. Switchover Upon AC loss, instantaneous. Zero voltage drop. Supervision AC Failure Form "C" contacts. Battery Fail Form "C" contacts. Battery Presence Form "C" contacts. Low DC Power Shutdown Prevents deep discharge (24VDC / 70-75%). Indicators (LED) LCD Display Indicates trouble and conditions of operation Facilitates quick identification of a fault. Displays which output fault has occurred on. Agency Listings UL/cUL UL 864 Control Units and Accessories for Fire Systems. UL 2017 General Purpose Signaling Devices and Systems. CAN/ULC-S527-99 Control Units for Fire Alarm Systems. FM Factory Mutual Approved. California State Fire Marshall Approved NFPA 72 and NFPA 720 Compliant Physical and Environment Dimensions (L x W x H) 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm) Enclosure accommodates up to two (2) 12VDC/12AH batteries. Product Weight 12.4 lbs. (5.62 kg). Shipping Weight 13.7 lbs. (6.21 kg). Temperature Operating 0°C to 490C (32°F to 1200F). Storage -200C to 700C (-4°F to 1580F). Relative Humidity 85% +/-5%. BTU/Hr. (approx.): 123 BTU/Hr. Altronix Corporation 1 140 58th St I Brooklyn, NY 11220 USA phone: +1 718.567.8181 1 fax: +1 718.567.9056 1 email: info@altronix.com I www.altronix.com Commander Series Selectable Candela Evacuation Signals Applications The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone. All tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the temporal three alarm mode. The GC Series has a very minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander Series comes standard with the 4" mounting plate which incorporates the popular Super -Slide° feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander also features the patented Checkmate° - Instant Voltage Verification feature which allows the installer to check the voltage drop draw without removing the signal. The GC Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use with fire protective systems and are warranted for three years from the date of purchase. Standard Features • Nominal voltage 24VDC • Tamperproof field selectable candela options of 15, 30, 75, 95,115 & 150 • Super -Slide° Bracket - Ease of Supervision Testing • Checkmate° - Instant Voltage Verification • Unit Dimensions: 6" (15.24 cm) x 2.6" (6.604 cm) • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input Terminals 12 to 18 AWG • Switch Selection for High or Low dBA • Switch Selection for 2400Hz or Mechanical Tone • Switch Selection for Continuous or Temporal 3 • Tamperproof re-entrant grill • Surface mount with the GCSB (Gentex Ceiling Surface Mount Box) GCS/GCC 24VDC SERIES ;k t. ; Product Listings SIGNALING OO APPROVED FRViGQ' LISTED • ANSI/UL 464 and ANSI/UL 1971 Listed • FM Approved • CSFM: 7135-0569:122 (GCC) 7125-0569:123 (GCS) • MEA: 285-91-E Patents • 7,375,617 May 20, 2008 Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • I BC/I FC/I RC • City & State ordinances/Laws/Regulations • Quality Management System is certified to: ISO 9001:2008 • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white MEMBER ASSEMBLED IN THE USA GCS Series 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela GCS24CR 904-1213-002 24VDC 15, 30, 75, 95, 115, 150 GCS24CW 904-1215-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCR 904-1214-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCW 1 904-1216-002 1 24VDC 1 15, 30, 75, 95, 115, 150 GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA @ 1Oft. per ANSI/UL 464 In Anechoic Room dBA @ 1011t. GCC24CR 904-1209-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCW 1 904-1212-002 1 24VDC 1 15, 30, 75, 95, 115, 150 1 81-86 90 Model Designations: C = Ceiling Mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. GC24 Product Strobe Current Ratings (mA) Candela 15cd 30cd 75cd 95cd 115cd 150cd 24VDC (16-33 Volts) 24VDC 72mA 101 mA 167mA 200mA 214mA 286mA UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA GCC24 Product Horn Decibel and Current Ratings (mA) Horn Mode Minimum dBA @ 10ft. per ANSI/UL 464 (HIGH) Minimum dBA @ 10ft. per ANSI/UL 464 (LOW) Regulated 24VDC Max. Operating @ High Setting (mA) Temp 3 2400Hz 83 75 23 emp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • Operating temperature: 32°to 120°F (0° to 49°C). The GC Series is not listed for outdoor use. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super -Slide° 3. SNAP COVER OVER ASSEMBLY 2. INSERT LOCKING SCREW �r o �BMWs� a�o4s f • 8 1. SLIDE ONTO BRACKET Checkmate° Instant Voltage Verification Switch Locations D® 0 G°�PdfP - 0 0 o� o O o R E M 0 O s+ �e t H. ® H- x t A 0 FH- (e�w4��D O00o C� � �J o The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTICE: CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. Switch positions 1 and 2 in the down position to select isolated horn and strobe power inputs. Switch 3 selects between temporal or non -temporal tone. Up is temporal. Switch 4 selects between mechanical or high frequency tone. Up is mechanical. Switch 5 selects between high or low dBA. Up is high dBA. GCS/GCC 24VDC S E R I E Conventional GC Series Wiring Diagrams UL Listed Control Signal Signal Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised S S &I B Signal Circuit \ + END OF LINE RESISTOR UL Listed Control SignalMEND Panel S+ S+ S- H+ H-Supervised _77- Signal Circuit \ + OF LINE SISTOR \ + END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (551-0031) AND/OR AVSM CONTROL MODULE MANUAL (550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 29 pounds per carton Important Notice: 551-0051-06 G E N T E X These materials have been prepared Gentex Corporation Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and CORPORATION accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding Fire Protection Products Grou • www. entex.com interpretation of laws, regulations and rules and the application of such laws, regulations and rules to p g particular fact patterns. Each person's activities can differently affect the obligations that exist under 10985 Chicago Drive • Zeeland, Michigan 49464 applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. Commander Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications The Commander' Series is a low profile strobe and horn/strobe combination S E R I E S that offers dependable audible and visual alarms and the absolute lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela. The Commander' Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by the use of switches. The GE3 Series has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander' Series is shipped with a standard 4" metal mounting plate which incorporates the popular Super -Slide° feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander' also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The GE3 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase. Standard Features • Nominal voltage 12VDC and 24VDC • 24VDC units have field selectable candela options of 15, 30, 60, 75 & 110 • 12VDC units have field selectable candela options of 15, 30, 60 & 75 • GEH horn is available in 12VDC or 24VDC • Unit Dimensions: 5" (12.7 cm) high x 4.5" (11.43 cm) wide x 2.5" (6.35 cm) deep • Super -Slide° Bracket - Ease of Supervision Testing • Checkmate° - Instant Voltage Verification • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime, whoop, mechanical and 2400Hz tone • Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone (not available on whoop tone) • Surface mount with the GSB (Gentex Surface Mount Box) • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white Product Listings SIGNALING Uv,ST�pp LISTED FR" ANSI/UL 464 & ANSI/UL 1971 Listed CSFM: 7135-0569:122 (GEC3-24 & GEH-24) 7125-0569:123 (GES3-24) 7125-0569:129 (GES3-12) 7135-0569:130 (GEC3-12 & GEH-12) MEA: 285-91-E (GEC3-24 & GES3-24) 580-06-E (GEC3-12 & GES3-12) Patents • 7,375,617 May 20, 2008 Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • IBC/IFC/IRC • Quality Management System is certified to: ISO 9001:2008 Jii 1�i MEMBER ASSEMBLED IN THE USA GEH 12VDC or 24VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage ever erant dBA at 10ft., per ANSI/UL 464 In Anechoic Room dBA at 10ft. GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 GEH24-W 1 904-1207-002 1 24VDC 1 62-82 1100 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) GES3-12WR 904-1235-002 12 VDC 15, 30, 60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30, 60, 75 GES3-24WR 904-1321-002 24 VDC 15, 30, 60, 75, 110 GES3-24WW 1 904-1319-002 24 VDC 15, 30, 60, 75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela (ANSI/UL 1971) Reverberant dBA at 1Oft., per ANSI/UL 464 In Anechoic Room dBA at 1Oft. GEC3-12WR 904-1231-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 1 904-1315-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GE3 Product Strobe Current Ratings (mA) 12 VDC (8-17.5 Volts) 24 VDC (16-33 Volts) Candela 12VDC UL Max' 24VDC UL Max' 15cd 106mA 92mA 30mA 42mA 30cd 131 mA 141 mA 35mA 58mA 60cd 186mA 260mA 66mA 97mA 75cd 237mA 312mA I 80mA I 116mA 110cd 1103mA 1 161 mA GE3.12 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Mode Minimum SPL at tOft., per ANSI/UL 464 (HIGH) Minimum SPL at loft., per ANSI/UL 464 (LOW) Regulated 12VDC Max. Operating High Setting (mA) Temp 3 2400Hz 76 dBA 69' dBA 29mA Temp 3 Mechanical 75 dBA 68' dBA 26mA Temp 3 Chime 62` dBA 60` dBA 13mA Continuous 2400Hz 79 dBA 74` dBA 29mA Mechanical 78 dBA 72" dBA 26mA [Conl.,nuous ntinuous Chime 63` dBA 61' dBA 13mA hop 78 dBA 71dBA 55mA NOTES: Model Designations: W = Wall mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. ERT bezel available for order iENT bezel available for order GE3.24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Horn Mode Minimum SPL at 1 Oft., per ANSI/UL 464 (HIGH) Minimum SPL at 10ft., per ANSI/UL 464 (LOW) Regulated 24VDC Max. Operating High Setting (mA) Temp 3 2400Hz 78 dBA 71' dBA 28mA Temp 3 Mechanical 76 dBA 70' dBA 25mA Temp 3 Chime 70' dBA 66' dBA 15mA Continuous 2400Hz 81 dBA 74' dBA 28mA Continuous Mechanical 80 dBA 72" dBA 25mA Continuous Chime 70' dBA 66` dBA 15mA Whoop 82 dBA 69' dBA 56mA • Operating temperature: 32°to 120°F (0' to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). ' RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical - Continuous OFF ON ON 2400Hz - Temporal 3 ON OFF ON 2400Hz - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Chime - Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Gentex Super -Slide° Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap -in -place installation. Candela selection slider switch. Depress center and slide switch to desire brightness level. \ Break off pin and insert into hole at the bottom of the selector to lock candela setting. Signal must be removed from bracket and pin pushed — forward from backside out of hole to change candela. GENT�x 75 30 60 i5 DE 76 MODEL SELECTION MARKER Gentex Checkmate° Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. To remove bezel, grip both sides of bezel and pull in a downward and outward motion. GEC3/GES3 12 &24VDC SElIEa&m Conventional Wiring Diagrams for Emergency Notification Evacuation Series Signal Signal S+ S+ S- H+ H- S+ S+ S- H+ H- Signal Signal S+ S+ s- H+ H- S+ S+ S- H+ H- LIL Listed Control Panel su ervis p ad UL Listed Control Panel SupervisedIf—if Signal Circuit & 0 &I J L Signal Circuit \ + END OF LINE RESISTOR END OF LINE \ _ RESISTOR ��D + \ - ENDOFLINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (551-0031) AND/OR AVSM CONTROL MODULE MANUAL (550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. • When synchronizing the GE312VDC Series, the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH, GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 1971 and/or ANSI/UL 464. The notification appliance shall also be listed with Factory Mutual Listing Service (FM) and the California State Fire Marshal (CSFM). The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. GENTEX CORPORATION Fire Protection Products Group• www.gentex.com 10985 Chicago Drive • Zeeland, Michigan 49464 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each persons activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Standard Features: • 16 gauge steel construction • Durable red textured finish • White 1"indelible lettering "AS BUILT DRAWINGS" • Stainless steel piano hinge with CAT 30 keyed door lock • Surface mount box • Wall mounting holes Options: • Custom finish • Custom legend • Custom lock • Flush Flange As Built Drawings Cabinet The DBX "AS BUILT DRAWINGS" Cabinet offers the conve- nience of having building layouts and alarm documents readily accessible for fire departments and other authorized person- nel. This surface mount cabinet is fabricated from 16 gauge steel with a durable, baked on, red textured powder coat finish, white 1" high lettering and features a stainless steel piano hinge and a high security CAT 30 keyed door lock. Stainless Sti Custom Loc Hvaiiame in sizes AA, A & D ISO 9001 �1► REGISTERED N'F11P'l� Made In u.s.a. COMPANY Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0132 LT10045 Rev.F 1/2 No Excuses, Just Solutions! /NSPACE AGE LECTRONICS, INC_ Specifications: The DBX As Built Drawings Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and fin- ished with a durable red textured, heat -resistant baked -on enamel finish. The front cover includes a durable label displaying "AS BUILT DRAWINGS" in 1" white indelible lettering, applied to the cover relative to the orientation of the installed back box. The front cover features a high security CAT 30 keyed door lock. Custom finish, legend and lock available. Back box universal surface mount design and wall mounting holes. Size Dimensions of Cabinet W H D AA 12 1 /4" 14 1 /4" 4" A 26 1 /4" 14 1 /4" 4" D 26 1 /4" 23 5/8" 4" Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Custom labels available 1� w ;s steel D hinge Ordering Information: Part # Description SS000674 DBXAA As Built Drawings Cabinet, Red SS000677 DBXA As Built Drawings Cabinet, Red SS000678 DBXD As Built Drawings Cabinet, Red SS000680 DBXA Semi Flush Flange, Red SS000681 DBXD Semi Flush Flange, Red No Excuses, Just Solutions! This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0132 LT10045 Rev.F 2/2