Loading...
FIR2021-0028+Fire_Alarm_Plan+3.24.2021_10.36.53_AM+2108988R D�I-C���la�DO�laN RC� A�Q��] �KAF 1� - -Doi p�0�1�[�k EDMONDS9 MA VICIMTY MAP e� ya" Elementary School r z �� ert�nssw -' lam 5[6N 2Ppl.9 Gw FIVE N ago- 22fillr 51 �t: ,e>n��srr *ns Edmonds Memorial79 _ Cemetery 22817 t02nd PI VV, WESTGATE x s mm� s+ew ♦Vdmonds, WA 98020 Westg s _ - -- Sherwood Ono Aulberttic Elementary School THawaiian Poke Y +Q� ` 9 y P © { PRC E. North Amaricart Martyrs Senber Lake High School Catholic Church SHERWOOD = :saihs,sw FOREST P Edmonds Heights K-12 c f OPERATIONAL MATRIX I EQUIPMENT LEGEND I SHEET INDEX SYSTEM OUTPUTS Required Fire Safety Control Central Station Reporting Control Unit Annunciation o� C y0 C� yw� r0 O G � C O co CO �V J C y =0 Q O Nv w C Q co oo C i 0 A.i 4y v� v hv v Q IT IT Q SYSTEM INPUTS A I B I C D E F oke Detectors X X X X 1 Q V4Unused at Detectors X X X X 2 Jused Q 3 4 5 Fire Alarm AC Power Failure XI IxI5 W 6 J Fire Alarm System Low Battery X X 6 CID 7 Open Circuit X X 7 0 8 Ground Fault X X 8 ~ 9 Notification Appliance Circuit Short X X 9 10 RPS Trouble Condition x x 10 DODO©R AFF ABOVE FINISHED FLOOR NAC N❑TIFICATI❑N APPLIANCE CIRCUIT AHJ AUTH❑RITY HAVING JURISDICTI❑N NEC NATI❑NAL ELECTRIC CODE ccl CANDELA NFPA NATIONAL FIRE PR❑TECTI❑N AGENCY ELEV ELEVATOR RPS REMOTE POWER SUPPLY E❑L END OF LINE RESISTOR SIG SIGNAL (N❑TIFICATI❑N) CIRCUIT EX EXISTING SMK SMOKE DETECTOR FACP FIRE ALARM CONTROL PANEL T.I. TENANT IMPR❑VEMENT IBC INTERNATIONAL BUILDING CODE WP WEATHERPROOF IFC INTERNATI❑NAL FIRE CODE ZN ZONE (INITIATING CIRCUIT) MACH MACHINE City Of Edmonds Fire Department Work F/A MODIFICATION FOR T/I Address 1]❑817 10❑ND PL W Owner TR INTERNATIONAL Approved Date Appravedby_-Fire Fire Official 04/07/2021 AFM KFitterer ---------------------------------- Permit Number ---- FIR1101111100118 I I A A A < < < < < A A A A A A A A A A A < < < < A A A A A A A A A < < < < Need Annunciator in front lobby with a Knox entry key box DEVICE SYMBOL CITY. MANUFACTURER PART NO. DESCRIPTION BACK BOX FACP EX SILENT KNIGHT 5204 EXISTING FACP , CONVENTIONAL, 4 ZONE N/A 1 ALTRONIX FIRESWITCH108 10 AMP, 8 OUTPUT 24 VOLT POWER SUPPLY N/A 0 2 EDWARDS 302-194 HEAT DETECTOR, RATE COMPENSATED, 194F SINGLE -GANG 0 16 SYSTEM SENSOR 2W-B 2-WIRE STANDARD 13 DETECTOR SINGLE -GANG o, 12 GENTEX GCC24CR CEILING MOUNT SELECTABLE HORN STROBE, RED SINGLE -GANG I0. 14 GENTEX GCS24CR CEILING MOUNT SELECTABLE STROBE, RED SINGLE -GANG �o EX GENTEX GEC3-24WR SELECTABLE CANDELA HORN/STROBE, RED EX �Ii EX GENTEX GES3-24WR SELECTABLE CANDELA, STROBE, RED EX WP EX SYSTEM SENSOR SRK STROBE OUTDOOR RED EX l EX SYSTEM SENSOR SSM24-8 ALARM BELL 8" 24VDC, RED EX D0C 1 SPACEAGE BW-DOC FA DOCUMENT CABINET N/A 2 DURACELL 12V8AH 12vdc 8Ah RPS BATTERY N/A THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. POWER FOR ALL FIRE ALARM PANELS, COMMUNICATORS AND FIRE ALARM POWER SUPPLIES MUST BE PROVIDED BY A DEDICATED 120VAC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE FACP, MECHANICALLY PROTECTED, ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL AND SHALL BE RED AND LABELED "FIRE ALARM CIRCUIT CONTROL" IN ACCORDANCE WITH NFPA 72. POWER -LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NON -POWER LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NON -POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION EQUIPMENT. WHERE INSTALLED EXPOSED, CABLES SHALL BE ADEQUATELY SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR, IT SHALL BE RUN IN RACEWAY. THE INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND NOTIFICATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B"). THESE LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. CENTER SMOKE DETECTORS IN CORRIDORS W/ CEILING LIGHTING WHEN POSSIBLE. SMOKE DETECTORS IN CORRIDORS ARE TO BE SPACED PER NFPA 72 17.6.3.1.1(H) & 17.7.3.2.4.2(4). LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. WALL -MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MAXIMUM OF 12" FROM CEILING. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED 100%. WALL MOUNTED STROBES SHALL BE PLACED 80" MINIMUM TO 96" MAXIMUM ABOVE FLOOR LEVEL. (NFPA72 18.5.4.1 & 2). WALL MOUNTED STROBES SHALL BE SIZED IN ACCORDANCE WITH (NFPA72 TABLE 18.5.4.3.1(A). CEILING MOUNTED STROBES SHALL BE PLACED AND SIZED IN ACCORDANCE WITH (NFPA-72 TABLE 18.5.4.3.1(B). WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME WHETHER THEY ARE IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THE FLASH OF THOSE STROBES SHALL BE SYNCHRONIZED (NFPA-72, SECTION 18.5.4.3.2(3) & (4). INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD DRAWINGS OTHERWISE REFERRED TO AS ("AS -BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM DOCUMENT CABINET NEXT TO THE FACP (NFPA-72 10.18.2.3). PRIOR TO CALLING FOR INSPECTION, THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE SYSTEM HAS BEEN INSTALLED, TESTED, EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE APPROVED PLANS. THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN NFPA-72 RECORD OF COMPLETION (NFPA-72 10.18.2.1.1). THE COMPLETED RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ INSPECTOR PRIOR TO REQUESTING A FIRE FINAL INSPECTION (NFPA-72 10.18.2.1.2.4). SHEET # SHEET DESCRIPTION FA 0+0 FIRE ALARM - PROJECT DETAILS FA 1,0 FIRE ALARM - FLOOR PLAN FA 2.0 FIRE ALARM - EXISTING LAYOUT FA 3+0 FIRE ALARM - CEILING PLAN FA 4+0 FIRE ALARM - BATTERY & VOLTAGE DROP CALCULATIONS FA 5+0 FIRE ALARM - SINGLE LINE RISER DIAGRAM FA 6,0 FIRE ALARM - EQUIPMENT INSTALLATI❑N DETAILS TENANT TR International 22817 102nd Place W Edmonds, WA 98020 Contact : Beth Tragus-Campbell 206.505.3500 ELECTRICAL CONTRACTOR Evergreen Power Systems Inc. 3623 E. Marginal Way S Seattle, WA 98134 Contact : Justin Branson 425.736.2407 ibranson ©evergreenps.net FIRE ALARM CONTRACTOR Fire Protection Inc 17410 ASH WAY, Ste 8 LYN N WOOD, WA 98037 CONTACT : David Mow 425.290.9600 david©fpiseattle.com AUTH❑RITY HAVING JURISDICTI❑N : CITY ❑F EDMONDS MUNICIPAL CODE : CITY ❑F EDMONDS BUILDING CODE : INTERNATIONAL BUILDING CODE, 2015 EDITI❑N FIRE CODE : INTERNATI❑NAL FIRE CODE, 2015 EDITI❑N BUILDING USE AND OCCUPANCY I B - N❑N-SPRINKLED STANDARDS: 2014 NFPA 70, 2016 NFPA 72, CITY OF EDMONDS STANDARDS CLASSIFICATI❑N OF SUPERVISING STATION : REMOTE SUPERVISING STATI❑N PARCEL NUMBER : 00610700202001 A Part/Smarts Fire Alarm Tenant Improvement per the City of Edmond's requirements. The main floor of the existing non —sprinkled building is undergoing a tenant improvement. This is a Parts/Smarts project, FPI will provide a code compliant design, fire alarm permit/submittals, new fire alarm equipment, system pre —testing and final acceptance testing. Evergreen Power Systems Inc will provide the electrical permit and electrical installation as shown. The main floor of the existing building will be brought up to current code per Edmonds Municipal Code 19.25.035. Additional Detection and Occupant Notification will be installed in areas lacking proper coverage, all exiting devices to remain unless noted. The existing FACP (SK-5204) is located in the electrical room on the lower floor. Edmonds Municipal Code as it relates to fire amendments: 19.25.035 Fire protection systems: C. Fire Alarms and Detection Systems. In addition to the requirements of Section 907.2, an approved, monitored automatic fire alarm system shall be installed and maintained throughout all buildings, structures, floors, and suites described in this section. If conflicts exist between the IFC and this section, this section shall prevail. Fire alarm systems shall be installed per NFPA 72 and SCF's fire alarm standard. Partial area fire alarm systems are prohibited except where approved by the fire code official. A re alarm sianaar as approved by the fire code official. Fire Alarm Device Identification INITIATING DEVICES NOTIFICATION DEVICES FACP ZONE NAC CIRCUIT # CANDELA DEVICE NUMBER F-DEVICE # NAC3.01 Z02.30 S 15 CD by NFPA 72 and SCF's CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. ( Q/M ft ) DESCRIPTION TOTAL A 14/2 FPLR 14 3.07 NAC NOTIFICATION APPLIANCE CIRCUIT 1200' Z 18/2 FPLR 18 7.77 IDC ANALOG INITIATING DEVICE CIRCUIT 500' All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION C❑NDITI❑NS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) �p AV FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS nor Cpx VIM 4 1 M NFPA 30 ti CFP5 # 1473 H � H U rn H cn w H A U H � a � �oHaH�a C)l�H W ('4 4 a C1 1n O A N l -4C)M ; 01-1 C411 �wa 1Q aH a AM H k 0W4 rT4 En HoA0HA vW o zi E=W14 Ea—I=WWa 0 H W> WL46W Q REVISION RECORD DATE / DESCRIPTION DATE: 1 3/22/21 PROJECT NAME O 00 .0 a Q i N ., 0 O N � O 00 E N 'a N LU RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM TENANTIMPROVEMENT PROJECT DETAILS SHEET NUMBER I FA OmO cpk CD LOWER LEVEL - FLOOR PLAN SCALE: 1 /8" = l' OD -O OFF- (MGB) EOL . N AC3.08 EOL 30cd # KEY NOTE DETAILS 11) A DEDICATED 120VAC POWER CIRCUITS IS REQUIRED FOR THE REMOTE POWER SUPPLY, ® EXISTING SMOKE/HEAT DETECTOR TO REMAIN AS -IS, ® EXISTING SMOKE/HEAT DETECTOR TO BE REUSED AND RELOCATED TO THE LOCATION SHOWN, ® EXISTING OCCUPANT NOTIFICATION DEVICE AND CIRCUIT TO REMAIN AS -IS. ® EXISTING OUTDOOR BELL AND STROBE TO REMAIN AS -IS, © NEW SMOKE/HEAT DETECTORS ARE TO BE TIED INTO THE EXISTING INITIATING ZONE SERVING THIS FLOOR, VERIFY THAT THIS EXISTING DEVICE IS CURRENTLY THE END OF LINE (EOL) DEVICE, THE EOL RESISTOR WILL BE RELOCATED TO THE LAST DEVICE ON THE NEW CIRCUIT, SEE EXISTING FA PLAN ON SHEET FA 2,0 FOR EOL DEVICE, EXISTING FA PLAN SHOWN ON SHEET FA 2,0 IS BASED ON A PREVIOUS FIRE ALARM TI PLAN DATED 04/28/2007, ALL EXISTING DEVICE LOCATIONS SHOWN ARE TO BE FIELD VERIFIED), CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. (n/M ft ) DESCRIPTION A 14/2 FPLR 14 3.07 NAC NOTIFICATION APPLIANCE CIRCUIT Z 18/2 FPLR 18 7.77 IDC ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATION C❑NDITI❑NS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS vv;,0TEC;5O� 4 # � �. NFPA` CFPS #1473 H HLO UCA rn H 2 U p CO w El c �r U � H a 3 o �oaHc�a wUa O l- ?H Gj N QchLo AN H C) m C) AAP�HO H OG+ mHOAWa'HA O w H E-1 o > H W W Q Az14 rAaaa c REVISION RECORD DATE / DESCRIPTION DATE:1 3/22/21 1 PROJECT NAME I N m O r _ 00 Oaa i N ., (D O N S ti c O N N W RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM TENANTIMPROVEMENT FLOOR PLAN MAIN LEVEL - FLOOR PLAN SCALE : 1 /8" = l' SHEET NUMBER FA lm0 (D o- O O MAIN LEVEL - EXISTING FIRE ALARM PLAN SCALE : 1/8" = 1' • • m # KEY NOTE DETAILS 1) A DEDICATED 120VAC POWER CIRCUITS IS REQUIRED FOR THE REMOTE POWER SUPPLY, ® EXISTING SMOKE/HEAT DETECTOR TO REMAIN AS -IS, © EXISTING SMOKE/HEAT DETECTOR TO BE REUSED AND RELOCATED TO THE LOCATION SHOWN, 4O EXISTING OCCUPANT NOTIFICATION DEVICE AND CIRCUIT TO REMAIN AS -IS, ® EXISTING OUTDOOR BELL AND STROBE TO REMAIN AS -IS. © NEW SMOKE/HEAT DETECTORS ARE TO BE TIED INTO THE EXISTING INITIATING ZONE SERVING THIS FLOOR, VERIFY THAT THIS EXISTING DEVICE IS CURRENTLY THE END OF LINE (EOL) DEVICE, THE EOL RESISTOR WILL BE RELOCATED TO THE LAST DEVICE ON THE NEW CIRCUIT. SEE EXISTING FA PLAN ON SHEET FA 2.0 FOR EOL DEVICE. EXISTING FA PLAN SHOWN ON SHEET FA 2.0 IS BASED ON A PREVIOUS FIRE ALARM TI PLAN DATED 04/28/2007, ALL EXISTING DEVICE LOCATIONS SHOWN ARE TO BE FIELD VERIFIED). CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. ( S2/Mft) DESCRIPTION A 14/2 FPLR 14 3.07 NAC NOTIFICATION APPLIANCE CIRCUIT Z 18/2 FPLR 18 7.77 IDC ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATI❑N C❑NDITI❑NS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) 177 r— �r � f FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS ❑ ' rn w Y NFPA' ti7 � CFPS #1473 H Ln FLn W rn U ON H 2 U I � PG 3 o �oaHoa o r- >4 04 A0)Ln0AN >Nw°4 a�a A xow 0M wEn POHOWW�HA O �3aUGG� Hew H�wa g o H� W ta cn a Q Az14�cn4P4 o REVISION RECORD I DATE / DESCRIPTION DATE: I 3/22/21 1 PROJECT NAME I RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM TENANT IMPROVEMENT EXISTING FIRE ALARM LAYOUT SHEET NUMBER I FA 2.0 MAIN LEVEL - CEILING PLAN SCALE: 1/8" = 1' 5' 10' 2 0' FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS vm #0 ❑ -� w ��. NFPA` CFPS #1473 H LO H Lo Urn H Z U U) p cn al p U �c U � H a 3 o wop0a Z aUa O r- H 0 01 p4 O \ 4HA�+a 14 A APO H* Ow * wU) WHOW p O �3aUp4� H=tl--wH wa � o U H ',ww� Q,' H Q VWI > REVISION RECORD DATE / DESCRIPTION DATE:1 3/22/21 1 PROJECT NAME I N m O _ 00 oaCD .�Q i N .. O N S _ O N N W RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM TENANTIMPROVEMENT CEILING PLAN SHEET NUMBER EXISTING FACP (SK-5204) BATTERY CALCULATION SECONDARY POWER SOURCE REQUIREMENTS STANDBY CURRENT SECONDARY ALARM (AMPS) CURRENT (AMPS) QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL PANEL COMPONENTS 1 SK-4 MAIN BOARD FIRE ALARM CONTROL 1 x 0 = 0 1 x 0 = 0 PANEL MAIN BOARD CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT TOTAL (A) CURRENT TOTAL (A) DRAW (A) DRAW (A) Selectable Candela, Low 0 1 GEC3-24WR Profile Evacuation 1 x 0 = 0 1 x 0.108 = 0.108 Horn/Strobe, Red 75cd Selectable Candela, Low 3 GES3-24WR Profile Evacuation Strobe, 3 x 0 = 0 3 x 0.042 = 0.126 FACP-NAC2 Red 15cd 1 SRK Strobe red 1 x 0 = 0 1 x 0.158 = 0.158 WP 75tddoor l 1 SSM24-8 Alarm Bell 8" 24VDC, red 1 x 0 = 0 1 x 0.0535 = 0.0535 0 28 2W-B 2-wire Standard i3 28 x 0.0001 = 0.0028 28 x 0.13 = 3.64 Detector FACP •Z02 Heat Detector, rate 0 4 302-194 compensated, 194F 90.2C4 x 0 = 0 4 x 0 = 0 FACP•Z04 S 1 2W-B 2-wire Standard i3 1 x 0.0001 = 0.0001 1 x 0.13 = 0.13 Detector TOTAL 0.0029 TOTAL 4.2155 TANDBY (A ALARM (A) REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD 0.0029 x 24 = 0.07 AH SECONDARY ALARM LOAD 4.2155 x 0.08 = 0.35 AH STANDBY AND ALARM LOAD SUBTOTAL 0.42 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 0.51 AH PROVIDE (2) 12V 7AH BATTERIES @ 24VDC NEW RPS (FIRESWITCH108) BATTERY CALCULATION SECONDARY POWER SOURCE REQUIREMENTS PANEL POWER SUPPLY MAX CURRENT = 10A TOTAL USED CAPACITY = 4.016A (40.16 %) STANDBY CURRENT SECONDARY ALARM (AMPS) CURRENT (AMPS) QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL ( A) CURRENT DRAW (A) TOTAL PANEL COMPONENTS 1 FireSwitch108 Main 1 x 0.18 = 0.18 1 x 0.2 = 0.2 Board CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT TOTAL (A) CURRENT TOTAL (A) DRAW (A) DRAW (A) Horn Strobe, 24 VDC, 0 3 GCC24CR Red, Ceiling 15cd 3 x 0 = 0 3 x 0.143 = 0.429 Horn Strobe, 24 VDC, RPS-NAC1 0 1 GCC24CR Red, Ceiling 75cd 1 x 0 = 0 1 x 0.223 = 0.223 GCS Series 24 Volt 6 GCS24CR Ceiling Mount Selectable 6 x 0 = 0 6 x 0.12 = 0.72 Strobe, Red 15cd Horn Strobe, 24 VDC, 0 3 GCC24CR Red, Ceiling 15cd 3 x 0 = 0 3 x 0.143 = 0.429 Horn Strobe, 24 VDC, 0 1 GCC24CR Red, Ceiling 75cd 1 x 0 = 0 1 x 0.223 = 0.223 RPS-NAC2 GCS Series 24 Volt 3 GCS24CR Ceiling Mount Selectable 3 x 0 = 0 3 x 0.12 = 0.36 Strobe, Red 15cd GCS Series 24 Volt 1 GCS24CR Ceiling Mount Selectable 1 x 0 = 0 1 x 0.2 = 0.2 Strobe, Red 75cd Horn Strobe, 24 VDC, 0 4 GCC24CR Red, Ceiling 15cd 4 x 0 = 0 4 x 0.143 = 0.572 RPS•NAC3 GCS Series 24 Volt 4 GCS24CR Ceiling Mount Selectable 4 x 0 = 0 4 x 0.12 = 0.48 Strobe, Red 15cd TOTAL 0.18 TOTAL 3.836 STANDBY (A ALARM (A) REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD 0.18 x 24 = 4.32 AH SECONDARY ALARM LOAD 3.836 x 0.08 = 0.32 AH STANDBY AND ALARM LOAD SUBTOTAL 4.64 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 5.57 AH PROVIDE (2) 12V 7AH BATTERIES @ 24VDC Point -To -Point Voltage Drop Calculation for Panel FACP Circuit NAC2 Starting Calculation Voltage: 20.4v Minimum Operational Voltage: 16v Total Circuit Current: 0.4455A Total Distance: 390' Voltage Drop: 0.7v End Of Line Voltage: 19.7v Percent Drop: 3.43 % Wire GA=#14 AWG Wire Resistance (Q/Ft): 0.00307 Distance measured using drawn segment lengths with 15.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent Selectable Candela, Low Profil NAC2-01 GEC3-24WR Evacuation Horn/Strobe, Red 0.108A 113' 20.09v 0.31 v 1.51 % 75cd NAC2-02 SRK Strobe outdoor red 75cd 0.158A 157' 19.77v 0.63v 3.11 % NAC2-03 SSM24-8 Alarm Bell 8" 24VDC, red 0.0535A 3' 19.76v 0.64v 3.12 % NAC2.04 GES3-24WR electable Candela, Low Profile Evacuation Strobe, Red 15cd 0.042A 39' 19.73v 0.67v 3.27 % NAC2-05 GES3-24WR electable Candela, Low Profile 0.042A 50' 19.71v 0.69v 3.39 % Evacuation Strobe, Red 15cd NAC2-06 EOL GES3-24WR electable Candela, Low Profile Evacuation Strobe, Red 15cd 0.042A 29' 19.7v 0.7v 3.43 % Point -To -Point Voltage Drop Calculation for Panel RPS Circuit NAC1 Starting Calculation Voltage: 20.4v Minimum Operational Voltage: 16v Total Circuit Current: 1.372A Total Distance: 276' Voltage Drop: 1.39v End Of Line Voltage: 19.01v Percent Drop: 6.80 % Wire GA=#14 AWG Wire Resistance (n/Ft): 0.00307 Distance measured using drawn segment lengths with 15.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent GCS Series 24 Volt Ceiling NAC1-01 GCS24CR Mount Selectable Strobe, Red 0.12A 65' 19.85v 0.55v 2.68 % 15cd NAC1-02 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 13 19.76v 0.64v 3.16 NAC1-03 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 35' 19.52v 0.88v 4.32 % GCS Series 24 Volt Ceiling NAC1-04 GCS24CR Mount Selectable Strobe, Red 0.12A 23' 19.39v 1.01v 4.98 % 15cd GCS Series 24 Volt Ceiling NAC1-05 GCS24CR Mount Selectable Strobe, Red 0.12A 9' 19.34v 1.06v 5.22 % 15cd GCS Series 24 Volt Ceiling NAC1 -06 GCS24CR Mount Selectable Strobe, Red 0.12A 25' 19.22v 1.18v 5.76 % 15cd NAC1-07 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 19 19.15v 1.25v 6.10 GCS Series 24 Volt Ceiling NAC1-08 GCS24CR Mount Selectable Strobe, Red 0.12A 16' 19.11 v 1.29v 6.33 % 15cd NAC1 -09 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 75cd 0.223A 32' 19.04v 1.36v 6.66 % GCS Series 24 Volt Ceiling NAC1 •10 EOL GCS24CR Mount Selectable Strobe, Red 0.12A 40' 19.01v 1.39v 6.80 % 15cd Point -To -Point Voltage Drop Calculation for Panel RPS Circuit NAC2 Starting Calculation Voltage: 20.4v Minimum Operational Voltage: 16v Total Circuit Current: 1.212A Total Distance: 221' Voltage Drop: 1.09v End Of Line Voltage: 19.31v Percent Drop: 5.36 % Wire GA=#14 AWG Wire Resistance (n/Ft): 0.00307 Distance measured using drawn segment lengths with 15.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent GCS Series 24 Volt Ceiling NAC2-01 GCS24CR Mount Selectable Strobe, Red 0.12A 73' 19.86v 0.54v 2.67 % 15cd GCS Series 24 Volt Ceiling NAC2-02 GCS24CR Mount Selectable Strobe, Red 0.12A 12' 19.78v 0.62v 3.05 % 15cd GCS Series 24 Volt Ceiling NAC2-03 GCS24CR Mount Selectable Strobe, Red 0.12A 12' 19.71v 0.69v 3.39 % 15cd NAC2-04 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A , 27 19.57v 0.83v 4.09 NAC2-05 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 19, 19.48v 0.92v 4.49 % NAC2-06 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 75cd 0.223A , 23 19.41v 0.99v 4.87 NAC2-07 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 34' 19.34v 1.06v 5.22 % GCS Series 24 Volt Ceiling NAC2.08 EOL GCS24CR Mount Selectable Strobe, Red 0.2A 23' 19.31v 1.09v 5.36 % 75cd Point -To -Point Voltage Drop Calculation for Panel RPS Circuit NAC3 Starting Calculation Voltage: 20.4v Minimum Operational Voltage: 16v Total Circuit Current: 1.052A Total Distance: 319' Voltage Drop: 1.47v End Of Line Voltage: 18.93v Percent Drop: 7.22 % Wire GA=#14 AWG Wire Resistance (n/Ft): 0.00307 Distance measured using drawn segment lengths with 15.00 % additional length calculated Device Label Part No. Description Device Current Distance From Voltage At Voltage Drop Voltage Drop Previous Device Device From Source Percent NAC3-01 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A , 148 19.44v 0.96v 4.68 Horn Strobe, 24 VDC, Red, NAC3-02 GCC24CR Ceiling 15cd 0.143A 11' 19.38v 1.02v 4.98 % NAC3-03 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 30cd 0.143A 38' 19.21 v 1.19v 5.86 % GCS Series 24 Volt Ceiling NAC3-04 GCS24CR Mount Selectable Strobe, Red 0.12A 20' 19.13v 1.27v 6.23 % 15cd GCS Series 24 Volt Ceiling NAC3-05 GCS24CR Mount Selectable Strobe, Red 0.12A 26' 19.05v 1.35v 6.62 % 30cd GCS Series 24 Volt Ceiling NAC3-06 GCS24CR Mount Selectable Strobe, Red 0.12A 28' 18.98v 1.42v 6.94 % 15cd NAC3-07 GCC24CR Horn Strobe, 24 VDC, Red, Ceiling 15cd 0.143A 24' 18.95v 1.45v 7.13 GCS Series 24 Volt Ceiling NAC3.08 EOL GCS24CR Mount Selectable Strobe, Red 0.12A 25' 18.93v 1.47v 7.22 % 30cd FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS 90TEC;5O� 4 � � �. NFPA` CFPS #1473 H HLn Urn H U 2En c �r U *I-- H 3a o �oaHc�a O l- ?H Gj N A cn Ln C14 AAP�HO H OG+ f�HOAWa'HA O w Hftww o > Cn H � Az14 rWAaaa c REVISION RECORD DATE / DESCRIPTION DATE:1 3/22/21 1 PROJECT NAME I RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM BATTERY & VOLTAGE DROP CALCULATIONS SHEET NUMBER FA 4mO NAC2.02 NAC2.06 EOL NAC2.05 75cd NAC2.01 15cd 15cd NAC2.04 NAC2.03 WP 75cd EX j EX\ 15cd� EX� EX EX NAC3.08 EOL NAC3.07 NAC3.06 NAC3.05 NAC3.04 NAC3.03 NAC3.02 NAC3.01 30,d 15cd 15cd 30cd� 15cd", 30cd 15cd 15cd ;O7 NAC2.08 EOL NAC2.07 NAC2.06 NAC2.05 NAC2.04 NAC2.03 NAC2.02 NAC2.01 75cd 15cd 75cd 15cd 15cd 15cd� 15cd�c( 15cd i NAC1 •10 EOL NAC1 •09 NAC1.08 NAC1.07 NAC1.06 NAC1.05 NAC1.04 NAC1.03 NAC1.02 NAC1.01 I ,5cd 75cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd .Mgw-FLDQ2--- - -- - - -- -- - -- - - I I I I I I I I I NAC EXPANDER POWER SUPPLY H -� DEDICATED 120V Cf-.520 AMP CIRCUIT Z04.1 EOL EX Z02.1 Z02.2 Z02• EX EX EX - S S CABLE AND WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. (Q/Mft) DESCRIPTION A 14/2 FPLR 14 3.07 NAC NOTIFICATION APPLIANCE CIRCUIT Z 18/2 FPLR 18 7.77 IDC ANALOG INITIATING DEVICE CIRCUIT All CONDUCTORS SHALL BE INSTALLED IN RACEWAYS SUITABLE FOR THE INSTALLATI❑N C❑NDITI❑NS, PER THE REQUIREMENTS OF IBC, IFC, NPFA-72 & NFPA-70 (NEC) Z02.32 EOL Z02.31 Z02.30 Z02.29 Z02.28 Z02.27 Z02.26 Z02.25 Z02.24 Z02.23 Z02.22 Z02.21 Z02.20 Z02.19 3 Z02.4 Z02.5 Z02.6 Z02.7 Z02.8 Z02.9 Z02.10 Z02.11 Z02.12 Z02.13 Z02.14 EX EX EX EX EX EX EX EX EX EX EX Z02.15 �ZO�6Z02.17 Z02.18 UU H S U S U U S USS S S LOWER FLOOR----------------------------------------------------------------------------------- LOWER FLOOR FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS qi�OTEC��O� 4 � (p C7 CFPS #1473 H Ln W CA U rn H 2 U p co w p � �r U *I-- H 3a o �oaHc�a aUa Or�?H WN AchU)2QN HC)m O\ �cliA�H W AAPO H k OG+ mHOAWa'HA O �aHw>wwacn 'a A2a�acn4 c REVISION RECORD DATE / DESCRIPTION DATE:1 3/22/21 1 PROJECT NAME I RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM SINGLE LINE RISER DIAGRAM SHEET NUMBER FA 5mO m m m m m m U) cn co� cn cn OJ OJ OJ OJ OJ OJ SK-5204 EXISTING FACP TERMINATION OF WIRE AT DEVICE YES NO TO FACP ZONE 4" MIN 12" MAX CEILING -MOUNTED 4" MIN `HEAT DETECTOR AUDIBLE/VISUAL NEVER AND/OR VISUAL HERE ONLY APPLIANCE � WALL -MOUNTED HEAT DETECTOR FSA ®Iko 66" TO TOP OF FSA FACP SYSTEM n RECORDSm DOCUMENTS 66" TO TOP OF FACP 82"-96" TO LOWEST PART OF LENS 66" TO TOP OF CABINET HEAT DETECTOR HEAT DETECTOR 6" MIN. A/C SUPPLY OR RETURN DIFFUSER CEIL � 36" MIN. PENDANT MOUNTED- AUDIBLE/VISUAL APPLIANCES -AUDIBLE-ONLY REMOTE ALARM CEILING MOUNTED) CEILING MOUNTED APPLIANCES � INDICATOR SMOKE/HEAT AUDIBLE/VISUAL � DETECTOR APPLIANCES 82-96" MIN. WHERE CEILING HEIGHT ALLOWS FINISHED FLOOR 4.7k RESISTOR CONVENTIONAL 2-WIRE HEAT DETECTOR AC utral 10' MAX AFF DOOR WIDTH T LESS 3!1--d 6" MAGNETIC �o DOOR HOLDER TERMINATION OF WIRE AT DEVICE YES NO 30' MAX AFF - 5' MAX. FROM EXIT o MANUAL PULL 42"-48" STATION TO FACP ZONE AC In TERMINATION OF TERMINATION OF WIRE AT DEVICE WIRE AT DEVICE YES NO YES NO FROM FACP TYPICAL REMOTE POWER S UPPL Y TO FACP/RPS SIG/NAC '� TOP �` '� 0 ®�aae:Q ® Op DO NOT PNFIr 0 WALL HORN/STROBE WALL HORN/STROBE 10k RESISTOR TO FACP/RPS SIG/NAC 30' MAX AFF NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST POINT OF DETECTOR 12" MAX WALL -MOUNTED SMOKE DETECTOR SIDE WALL FINISHED WALL 4.7k RESISTOR SMOKE DETECTOR SMOKE DETECTOR CONVENTIONAL 2-WIRE SMOKE DETECTOR \ DO NOT MNr / J Q O b CEILING HORN/STROBE 101 DO NOT MNr C�Q o O D K CEILING HORN/STROBE 10k RESISTOR r— f �' }' { � r z-J f FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM NFPA` #1473 H LO H Lo Urn H Z U U) H cn w F4 U � H a 3 o wop00 Eve wUa O N a' AMLO C4 H H C:) 0) O \ AAPO H >< Ow * w� WHOW p Q �H�wH�wa o U H ',ww� 4H Q WW � 0 Az4f U)i004 REVISION RECORD DATE / DESCRIPTION DATE: 1 3/22/21 PROJECT NAME RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE I FIRE ALARM EQUIPMENT INSTALLATION DETAILS WALL MOUNTED STROBE & HORN/STROBE CEILING MOUNTED STROBE & HORN/STROBE SHEET NUMBER