REVIEWED BLD BLD2020-1129+Structural_Calculations+10.21.2020_1.39.08_PMNASH & ASSOCIATES
ARCHITECTS
PLAN 3010
EDMONDS, WA
BEAM,
LATERAL
and
SEISMIC
CALCULATIONS
12871
REGISTERED`
A OHITECT e
ICHAE WAYNEJOHNSON
STATE OF WASHINGTON
2015 IBC
SELECT HOMES FEBRUARY 2020
7TH AVE S.P.
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
NASH & ASSOCIATES
ARCHITECTS
BEAM CALCULATIONS
2015 IBC
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
CLIENT:
NASH & ASSOCIAIM
BEAM DESIGN DATA
PROJECT:
ARCHITECTS
PER 2015 IBC
DATE:
NA.-lE-
Roof Loads:
LL 25 #/sf
DL 15 #/sf
Total 40 #/sf
Unless Noted Otherwise
Floor Loads:
LL 40 #/sf
DL 10 #/sf
Total 50 #/sf
Deck Loads:
LL 60 #/sf
DL 10 #/sf
Total 70 #/sf
Soil: 1500 PSF Min.
Concrete: Per IBC 2015
Masonry: Per IBC 2015
Steel: Per IBC 2015
Wood: Per IBC 2015
Nailing: Per IBC 2015
4" Beam: Douglas Fir #2
fv = 180
fb = 900 PSI
E = 1,600.000
6" Beam: Douglas Fir #2
fv = 170
fb = 875 PSI
E = 1,300,000
Joists & Hem Fir #2
Rafters: fv = 150
fb = 850 PSI
E = 1,300,000
Glu—Lam Beams:
fv = 240 PSI
fb = 2,400 PSI (reduced by size factor, CF*KI)
E = 1,800,000
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
PLAN 3010
DB-1
Selection
Conditions
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
CVRD. DECK
Date: 2/26/20
6x 12 DF-L #2 Lu = 0.0 Ft
NDS 2015
min Dearing Area K1= z.z in- Kz= z.z in- t7.01 uL ueti= u.-ie in
Beam Span
15.5 ft
Reaction 1 LL
775 # Reaction 2 LL 775 #
Beam Wt per ft
15.37 #
Reaction 1 TL
1359 # Reaction 2 TL 1359 #
Bm Wt Included
238 #
Maximum V
1359 #
Max Moment
5267 W
Max V (Reduced)
1191 #
TL Max Defl
L / 240
TL Actual Defl
L / 610
LL Max Defl
L / 360
LL Actual Defl
L / > 1000
Section (in')
Shear (in')
TL Defl (in)
LL Defl
121.23
63.25
0.30
0.14
72.23
10.51
0.78
0.52
OK
OK
OK
OK
60%
17%
39%
28%
Fb(psi)
Fv(psi)
E(psi x mil
Fc i(psi)
Reference Values
875
170
1.3
625
Adiusted Values
875
170
1.3
625
CF Size Factor
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 100 Uniform TL: 160 = A
Uniform Load A
R1 = 1359 R2 = 1359
SPAN =15.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
CVRD.DECK
DB-2 Date: 2/26/20
Selection 6x 12 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Searing Area R1= 1.4 in2 R2= 1.4 in (1.5) DL Defl= 0.11 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Loads
Beam Span
15.5 ft
Reaction 1 LL
488 # Reaction 2 LL 488 #
Beam Wt per ft
15.37 #
Reaction 1 TL
894 # Reaction 2 TL 894 #
Bm Wt Included
238 #
Maximum V
894 #
Max Moment
3465'#
Max V (Reduced)
784 #
TL Max Defl
L / 240
TL Actual Defl
L / 918
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section in'
Shear in2
TL Defl in
LL Defl
121.23
63.25
0.20
0.09
47.52
6.91
0.78
0.52
OK
OK
OK
OK
39%
11%
26%
17%
ra {Psl)
rv(psi)
t(psi x m1l
rc i s3
Reference Values
875
170
1.3
625
Adjusted Values
875
170
1.3
625
CF Size Factor
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
CI Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 63 Uniform TL: 100 = A
Uniform Load A
R1 = 894 R2 = 894
SPAN = 15.5 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
DINING
RB-1 Date: 2/26/20
Selection 6-3/4x 10-1/2 GLB 24F-V4 DF/DF Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 8.7 in2 R2= 8.7 in (1.5) DL Defl= 0.22 in Recom Camber= 0.32 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adiustments
Loads
Beam Span
12.0 ft
Reaction 1 LL
3450 # Reaction 2 LL 3450 #
Beam Wt per ft
17.22 #
Reaction 1 TL
5623 # Reaction 2 TL 5623 #
Bm Wt Included
207 #
Maximum V
5623 #
Max Moment
16870'#
Max V (Reduced)
4803 #
TL Max Defl
L / 240
TL Actual Defl
L / 324
LL Max Defl
L / 360
LL Actual Defl
L / 630
Section in'
Shear in2
TL Defl in
LL Defl
124.03
70.88
0.44
0.23
84.35
30.02
0.60
0.40
OK
OK
OK
OK
68%
42%
74%
57%
Fb (psi)
Fv (psi)
E (psi x mil)
FC!
Reference Values
2400
240
1.8
650
Adjusted Values
2400
240
1.8
650
Cv Volume
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 575 Uniform TL: 920 =A
Uniform Load A
Z
R 1 = 5623 R2 = 5623
SPAN =12FT
Uniform and partial uniform loads are Ibs per lineal ft.
RB-2
Selection
Conditions
Data
Attributes
Actual
Critical
Status
Ratio
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
MASTER BDRM.
3-1/8x 9 GLIB 24F-V4 DF/DF
Lu = 0.0 Ft
NDS 2015
Min Bearing Area
R1= 4.3 inZ
R2= 4.3 in (1.5)
DL Defl= 0.11 in Recom Camber= 0.16 in
Beam Span
8.0 ft
Reaction 1 LL
1752 # Reaction 2 LL 1752 #
Beam Wt per ft
6.83 #
Reaction 1 TL
2827 # Reaction 2 TL 2827 #
Bm Wt Included
55 #
Maximum V
2827 #
Max Moment
5655'#
Max V (Reduced)
2297 #
TL Max Defl
L / 240
TL Actual Defl
L / 424
LL Max Defl
L / 360
LL Actual Defl
L / 814
Section in'
Shear ins
TL Deft in
LL Defl
42.19
28.13
0.23
0.12
28.27
14.36
0.40
0.27
OK
OK
OK
OK
67%
51%
57%
44%
Fb [psi
Values Reference Values 2400
Ad'usted Values 2400
Fv (psi) E (psi x mil) Fc
240 1.8 650
240 1.8 650
Adjustments
Cv Volume 1.000
Cd Duration 1.00 1.00
Cr Repetitive 1.00
Ch Shear Stress N/A
Cm Wet Use 1.00 1.00
Loads
1.00 1.00
Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft
Uniform LL: 438 Uniform TL: 700 =A
Uniform Load A
R1 = 2827 R2 = 2827
SPAN = 8 FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
GUEST RM.
RB-3 Date: 2/26/20
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 3.7 in2 R2= 3.7 in' (1.5) DL Defl= 0.03 in
Data
Beam Span
6.0 ft
Reaction 1 LL
1425 # Reaction 2 LL 1425 #
Beam Wt per ft
7.87 #
Reaction 1 TL
2304 # Reaction 2 TL 2304 #
Bm Wt Included
47 #
Maximum V
2304 #
Max Moment
3455'#
Max V (Reduced)
1712 #
TL Max Defl
L / 240
TL Actual Defl
L / 999
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Attributes
Section [in')
Shear (in')
TL Defl (in)
LL Defl
Actual
49.91
32.38
0.07
0.04
Critical
38.39
14.26
0.30
0.20
Status
OK
OK
OK
OK
Ratio
77%
44%
24%
19%
Values
Adiustments
Loads
_
ro si
ry sr
t(psi x ma)
t-c! si
Reference Values
900
180
1.6
625
Ad'usted Values
1080
180
1.6
625
CF Size Factor
1.200
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Uniform LL: 475 Uniform TL: 760 = A
1. Uniform Load A
R1 = 2304 R2 = 2304
SPAN =6FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
CVRD. DECK
DB-3 Date: 2/26/20
Selection 6x 14 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 3.7 in2 R2= 3.7 in (1.5) DL Defl= 0.08 in
Data
Attributes
Actual
Critical
Status
Ratio
Beam Span
15.5 ft
Reaction 1 LL
1860 # Reaction 2 LL
Beam Wt per ft
18.04 #
Reaction 1 TL
2310 # Reaction 2 TL
Bm Wt Included
280 #
Maximum V
2310 #
Max Moment
8951 '#
Max V (Reduced)
1975 #
TL Max Defl
L / 240
TL Actual Defl
L / 643
LL Max Defl
L / 360
LL Actual Defl
L / 876
1860 #
2310 #
Section W
Shear inx
TL Defl in
LL Defl
167.06
74.25
0.29
0.21
124.87
17.42
0.78
0.52
OK
OK
OK
OK
75%
23%
37%
41%
Fb(psi)
Fv psi)
E (psi x mil)
Fc
Values
Reference Values
875
170
1.3
625
Adiusted Values
860
170
1.3
625
Ad ustmenfs
CF Size Factor
Cd Duration
0.983
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Loads
Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft
Uniform LL: 240 Uniform TL: 280 = A
Uniform Load A
R1 = 2310 R2 = 2310
SPAN =15.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
CVRD.PORCH
DB-4
Date: 2/26/20
Selection
6x 12 DF-L #2
Lu = 0.0 Ft
Conditions
NDS 2015
Min Bearing Area
R1= 2.4 in2
R2= 2.4 in (1.5) DL
Defl=
0.09 in
Data
Beam Span
15.5 ft
Reaction 1 LL
1163 #
Reaction 2 LL
Beam Wt per ft
15.37 #
Reaction 1 TL
1475 #
Reaction 2 TL
Bm Wt Included
238 #
Maximum V
1475 #
Max Moment
5717'#
Max V (Reduced)
1293 #
TL Max Defl
L / 240
TL Actual Defl
L / 617
LL Max Defl
L / 360
LL Actual Defl
L / 867
Attributes
Actual
Critical
Status
Ratio
Values
Ad(ustments
Loads
1163 #
1475 #
Section (in')
Shear (in')
TL Defl (in)
LL Defl
121.23
63.25
0.30
0.21
78.41
11.41
0.78
0.52
OK
OK
OK
OK
65%
18%
39%
42%
Fb(psi)
Fv(psi)
E(psi x mil
Fc(psi)
Reference Values
875
170
1.3
625
Adjusted Values
875
170
1.3
625
CF Size Factor
1.000
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
R 1 = 1475
Uniform LL: 150
Uniform Load A
Uniform TL: 175 = A
J
R2 = 1475
SPAN =15.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
BDRM. #3
B-1 Date: 2/26/20
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 3.4 in2 R2= 3.4 in (1.5) DL Defl= 0.02 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
6.0 ft
Reaction 1 LL
1740 # Reaction 2 LL 1740 #
Beam Wt per ft
7.87 #
Reaction 1 TL
2139 # Reaction 2 TL 2139 #
Bm Wt Included
47 #
Maximum V
2139 #
Max Moment
3208'#
Max V (Reduced)
1589 #
TL Max Defl
L / 240
TL Actual Defl
L / >1000
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Section ins
Shear in2
TL Defl in
LL Defl
49.91
32.38
0.06
0.05
35.64
13.24
0.30
0.20
OK
OK
OK
OK
71%
41%
21%
23%
Fb(psi)
Fv si
E(psi x mil
Fc 1(psi)
Reference Values
900
180
1.6
625
Ad'usted Values
1080
180
1.6
625
CF Size Factor
1.200
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 340 Uniform TL: 425 = A
Par Unif LL Par Unif TL Start End
240 H = 280 0 6.0
[ H
Uniform Load A
R1 = 2139 R2 = 2139
SPAN =6FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464--622
BONUS/ MEDIA RM.
B-2 Date: 2/26/20
Selection 4x 10 DF-L #2 Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 2.4 in2 R2= 2.4 in (1.5) DL Defl= 0.01 in
Data
Attributes
Actual
Critical
Status
Ratio
Values
Adjustments
Beam Span
6.0 ft
Reaction 1 LL
Beam Wt per ft
7.87 #
Reaction 1 TL
Bm Wt Included
47 #
Maximum V
Max Moment
2240'#
Max V (Reduced)
TL Max Defl
L / 240
TL Actual Defl
LL Max Defl
L / 360
LL Actual Defl
1200 # Reaction 2 LL 1200 #
1494 # Reaction 2 TL 1494 #
1494 #
1110 #
L / >1000
L / >1000
_Section (in3)
Shear (in2)
TL Defl (in)
LL Defl
49.91
32.38
0.04
0.03
24.89
9.25
0.30
0.20
OK
OK
OK
OK
50%
29%
15%
16%
Fb(psi)
Fv si
E(psi x mil
Fc I(psi)
Reference Values
900
180
1.6
625
Adjusted Values
1080
180
1.6
625
CF Size Factor
1.200
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads Uniform LL: 280 Uniform TL: 350 = A
Par Unif LL Par Unif TL Start End
120 H=140 0 6.0
H 77-71
Uniform Load A
Z\ Q
R1 = 1494 R2 = 1494
SPAN =6FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
B-3
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
BONUS/ MEDIA RM.
Date: 2/26/20
Selection
6-3/4x 13-1/2 GLIB 24F-V4 DF/DF
Lu = 0.0 Ft
Conditions
NDS 2015
Min Bearing Area
R1= 8.6 in2
R2= 8.6 in (1.5)
DL Defl= 0.13 in Recom Camber= 0.19 in
Data
Beam Span
15.5 ft
Reaction 1 LL
4340 # Reaction 2 LL 4340 #
Beam Wt per ft
22.14 #
Reaction 1 TL
5597 # Reaction 2 TL 5597 #
Bm Wt Included
343 #
Maximum V
5597 #
Max Moment
21687'#
Max V (Reduced)
4784 #
TL Max Defl
L / 240
TL Actual Defl
L / 445
LL Max Defl
L / 360
LL Actual Defl
L / 638
Attributes
Section in'
Shear(in')
TL Defl in
LL Defl
Actual
205.03
91.13
0.42
0.29
Critical
109.41
29.90
0.78
0.52
Status
OK
OK
OK
OK
Ratio
53%
33%
54%
56%
Values
Adiustments
Loads
Fb
Reference Values
2400
Adjusted Values
2379
Cv Volume
0.991
Cd Duration
1.00
Cr Repetitive
1.00
Ch Shear Stress
Cm Wet Use
1.00
Cl Stability
1.0000
Fv psi) E (psi x roil) Fc L (psi)
240 1.8
240 1.8
1.00
N/A
1.00 1.00
Rb=0.00 Le=0.00Ft
Uniform LL: 560 Uniform TL: 700 = A
Uniform Load A
R1 = 5597 R2 = 5597
SPAN =15.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
BEAM @ STAIR OPENING
B-4 Date: 2/26/20
Selection (2) 1-3/4x 11-7/8 1.9E TJ Microllam LVL Lu = 0.0 Ft
Conditions NDS 2015
Min Bearing Area R1= 1.7 in2 R2= 2.9 in2 (1.5) DL Defl= 0.05 in
Data
Beam Span
12.0 ft
Reaction 1 LL
960 # Reaction 2 LL
Beam Wt per ft
10.68 #
Reaction 1 TL
1264 # Reaction 2 TL
Bm Wt Included
128 #
Maximum V
2164 #
Max Moment
5380'#
Max V (Reduced)
1733 #
TL Max Defl
L / 240
TL Actual Defl
L / 905
LL Max Defl
L / 360
LL Actual Defl
L / > 1000
Attributes
Actual
Critical
Status
Ratio
Values
Adiusfinents
1680 #
2164 #
Section (W)
Shear (ins)
TL Defl (in)
LL Defl
82.26
41.56
0.16
0.11
24.80
9.12
0.60
0.40
OK
OK
OK
OK
30%
22%
27%
28%
Fb (psi)
Fv(psi)
E(psi x mil
Fc I(psi)
Reference Values
2600
285
2.0
750
Adjusted Values
2604
285
2.0
750
CF Size Factor
1.001
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Par Unif LL Par Unif TL Start End
100 H = 125 0 6.0
340 1 = 425 6.0 12.0
I
H
R1 = 1264 R2 = 2164
SPAN =12FT
Uniform and partial uniform loads are Ibs per lineal ft.
PLAN 3010
BeamChek v2018 licensed to: Nash & Associates Architects Reg # 6464-622
BEAM @ STAIR OPENING
B-5
Date: 2/26/20
Selection
(2) 1-3/4x 11-7/8
1.9E TJ Microlla_m LVL
Lu = 0.0 Ft
Conditions
NDS 2015
_
Min Bearing Area
R1= 1.8 inz
R2= 1.2 in (1.5) DL Defl= 0.06 in
Data
Beam Span
12.5 ft
Reaction 1 LL
1008 # Reaction 2 LL 672 #
Beam Wt per ft
10.68 #
Reaction 1 TL
1365 # Reaction 2 TL 932 #
Bm Wt Included
133 #
Maximum V
1365 #
Max Moment
6701 '#
Max V (Reduced)
1355 #
TL Max Defl
L / 240
TL Actual Defl
L / 864
LL Max Defl
L / 360
LL Actual Defl
L / >1000
Attributes
Section in'
Shear in'
TL Defl in
LL Defl
Actual
82.26
41.56
0.17
0.11
Critical
30.88
7.13
0.63
0.42
Status
OK
OK
OK
OK
Ratio
38%
17%
28%
28%
Values
Adjustments
Fb(psi)
Fv(psi)
E(psi x mil
Fc(psi)
Reference Values
2600
285
2.0
750
Adjusted Values
2604
285
2.0
750
CIF Size Factor
1.001
Cd Duration
1.00
1.00
Cr Repetitive
1.00
Ch Shear Stress
N/A
Cm Wet Use
1.00
1.00
1.00
1.00
Cl Stability
1.0000
Rb = 0.00
Le = 0.00 Ft
Loads
Point LL Point TL Distance
1680 B = 2164 5.0
Pt loads:
R1 = 1365 R2 = 932
SPAN =12.5FT
Uniform and partial uniform loads are Ibs per lineal ft.
CLIENT:
NASH&ASSOCIATES WIND AND SEISMIC DESIGN DATA PROJECT:
ARCHITECTS PER 2015 IBC DATE:
NAME:
WIND DESIGN CRITERIA
DESIGN PER ASCE 7-10
1. NOMINAL/ULTIMATE WIND SPEED V/asd / Vult
2. RISK CATEGORY II
3. WIND EXPOSURE CATEGORY
4. INTERNAL PRESSURE COEFFICENT
5. COMPONENTS AND CLADDING
DESIGN PRESSURE
85/110 mph
1.00
"B"
+/-55
+/— 16 psf
BUILDINGS, STRUCTURES, AND PARTS THEREOF SHALL BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD, AND RESISTANCE
FACTOR DESIGN, ALLOWABLE STRESS DESIGN, EMPIRICAL DESIGN OR CONVENTIONAL
CONSTRUCTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAPTER, SECTION 1604.1
BUILDINGS, STRUCTURES, AND PARTS THEREOF, SHALL BE DESIGNED TO WITHSTAND WIND LOADS
AS DEFINED IN SECTION 1609 AND ASCE 7-10
SIMPLIFIED METHOD TO BE USED FOR WIND DESIGN PER ASCE 7-10, SECTION 27.5
BUILDING HEIGHT IS LESS THAN 160 FEET)
110 MPH ULTIMATE WIND SPEED
USE 19.6 PSF PER TABLE 27.6.1 "EXPOSURE B"
WOOD DESIGN PER SECTIONS 2304-2306. STRUCTURES USING WOOD SHEAR WALLS
AND DIAPHRAGMS TO RESIST WIND, SEISMIC, AND ALL OTHER LATERAL LOADS SHALL
BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AF & PA SDPWS AND PROVISIONS
OF SECTIONS 2305-2306
SEISMIC DESIGN DATA
DESIGN PER ASCE 7-10/SECTION 1613
1. SEISMIC IMPORTANCE FACTOR
2. SHORT PERIOD ACCELERATION
3. 1 SECOND ACCELERATION
4. SITE CLASS
5. SPECTRAL RESPONSE COEFFICIENT
6. SPECTRAL RESPONSE COEFFICIENT
7. SEISMIC DESIGN CATEGORY
6. SEISMIC FORCE RESISTING SYSTEM
9. DESIGN BASE SHEAR
10. SEISMIC RESPONSE COEFFICIENT
11. RESPONSE MODIFICATION FACTOR
12. ANALYSIS PROCEDURE
13. RISK CATEGORY
Ie 1.00
Ss 1.86 *see footnote at bottom of page
S 1 0.748 *see footnote at bottom of page
D (default class per IBC)
S w 0.972 'see footnote at bottom of page
S n 0.748 *see footnote at bottom of page
D
PLYWOOD SHEAR WALLS
(see seismic calculations)
C s 0.13
R 6.5
EQUIVALENT LATERAL FORCE
II
THE ANCHORAGE OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE
DESIGNED IN ACCORDANCE WITH ASCE 7-10, SECTION 12.11.2
IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C—F, COLLECTOR ELEMENTS
AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RESIST
MAXIMUM EFFECTS AS SPECIFIED IN ASCE 7-10, SECTION 12.10.2.1
BASE SHEAR V= (F SDS /R) W
ANCHOR BOLTS: 5/8" DIA X 10", A307 OR BETTER W/ 7" MIN. EMBEDMENT. V= 1104#/BOLT
• PER USGS, THE MAXIMUM iS IN THE STATE OF WASHINGTON IS 0.748. ALL SEISMIC DESIGN VALUES USED
IN THIS ANALYSIS ARE BASED UPON THIS NUMBER. SINCE, S IS LESS THAN 0.75, THEN USE SEISMIC CATEC
D IF RISK CATEGORY IS 1, II, OR 111
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWW. NASH—ARCHITECTS. COM
Iqb psf
WEST ELEVATION
1Db•
SOUTH eLI=-Vr4TION
v
v
O
O
El------- --- --------- 19
HOL PE70M 5GHEMLE
HARK
HOLDOWW
STRAP
FA5TENER5
WOOD MEMBER
THICKNESS/SPECIES
ANCHOR
REQUiREP
T-1
STHM4/14 RJ
24-16d SINKER
(2) 2X4/2X6 STIRS
HF/5PF
T-2
MST46
(34)-16d
(2) 2X4/2X6 STIRS
Hp/$PF
T-3
1-15TA36
(26)-IOd
(2) 2X4/2X6 STIRS
HF/5PF
T-4
MSTG48B5
(B6)-IOd
WPl9
T-5
Hp-IB
(3)- 3/4"
B-1/2' MIN.
OF/SP
SSTH28 ('1/8")
MIN. 24-T/6"
EMBEDMENT
LOWER FLOOR
A
B
r
�
cv
m
HOLDDOwri sorIEDUIP
MARK
HOLDOWW
STRAP
FASTENERS
WOOD MEMBER
THICKNESS/SPECIES
ANCHOR
REGIUIRED
T-1
5THDI4/14 RJ
24-16d SINKER
(2) 2X4/2X6 STUDS
HF/SPF
T-2
M5T45
(54)-16d
(2) 2XF4/2X6 STUDS
M
T-5
M5TA56
(26)-IOd
(2) 2X4/2X6 STUDS
HF/SPF
T-4
MSTG4BB5
(SB)-IOd
HF/SPF
T-5
HD'!B
(5)- 5/41,
5-I/2" MIN.
DF/SP
SSTB20 (T/B")
EMBEDMENT
MAIN PLOOK
SHEAR YSAL.L. SGHE:w:�UL.E:m
PER 2015 1 BG
(GENERAL NOTES:
SEE PLANS TO DETERMINE THE DIFFERENT DE516NATOR5 FOR SHEAR WALL MATERIALS,
NAILING, ANCHOR BOLTS, AND HOLDOWN5. LOCATE HOLDOWN5 AS GL05E AS POSSIBLE TO THE END
OF THE DESIGNATED WALL.
ALL HOLDOV4N5, ANCHOR BOLTS, WA5HER5, 8 NAILS IN CONTACT WITH P.T. WOOD TO BE
HOT DIPPED GALVANIZED.
PI = ONE 51DE PLYWOOD
P2 = TWO SIDES PLYWOOD
7/I6°
NAIL SPAGIN6
TOP 4 BTM.
NGHORS
BLKG.
OPTIONAL
BASE
VALIUE#2
MARK
PLYWD.
EDGE5 FIELD
PLATES
d9.%ejj
REQ'D.
PLATE
ANCHOR BOLTS
SIMPSON
ANCHORS
NAILING
(#/LF)
PI-6"
ad
6"
12"
6"
18" O.G.
2x4
5/8" ® 48"
® 48" 8 ENDS
(2) Ibd ® 10"
240
PI-4"
8d
4"
12"
4"
I6" O.G.
2x4
5/5" ® 32"
® 30" 4 ENDS
(2) Ibd ® 7"
344
PI-3" **
ad
3"
12"
3"
14" O.G.
(2) 2x4/6
5/8" ® 24"
® 24" 4 ENDS
(2) Ibd ® 5"
450
PI-2" **
ad
2*
12"
2"
12" O.G.
(2) 2x4/6
3/4" ® 24"
® 18" 4 ENDS
(2) Ibd ® 5"
585
P2-6" **
8d
b"
12"
b"
10" O.G.
(2) 2x4/6
5/8" ® 24"
N/A
(2) Ibd ® 5"
480
P2-4" **
ad
4"
12"
4"
8" O.G.
(2) 2x4/6
3/4" ® 20"
N/A
(3) Ibd ® 5"
700
P2-3" **
8d
3"
12"
3*
1 8" O.G.
(2) 2x4/b
3/4" ® I6"
N/A
(4) Ibd ® 5"
Q00
P2-2" **
8d
2"
12"
2"
8" O.G.
(2) 2x4/6
3/4" ® 12" N/A
(4) Ibd ® 4"
1170
**NOTE: WALL5 WITH UNIT SHEAR OF 350#/ft. OR 6REATER SHALL HAVE FRAMING
MEMBERS (STUDS 4 PLATES) ABUTTING PANELS NOT LE55 THAN 3X MEMBERS OR (2) 2X MEMBERS
PER IBG 2015 AND 5DPW5-2015
PER SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC, CHAPTER
4.3.7.1 #4 EXPEGTION; (2) 2X MEMBERS ARE OK IN LIEU OF 3X
MEMBERS
STITCH NAIL DOUBLE STUDS AND PLATES TOGETHER WITH
Ibd NAILS ® 12" O.G. 5TA6ERRED ON THE STUD FACE
1. USE POWER -DRIVEN STEEL STUDS AND NAILS BY HILTY OR RAMSET WHERE APPLICABLE.
2. PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY.
3. SOLID BLOCK WITH J015T UNDER INTERIOR SHEAR WALLS.
SHEAR WALL NOTES
7/16" 05B OR PLYWOOD SHEATHING - USE 8d COMMON OR GALVANIZED NAILS. BLOCK ALL PANEL
EDGE5. LONG DIMENSIONS OF PLYWOOD MAY BE INSTALLED VERTICALLY. NAIL ® 12" O.G. TO ALL
INTERMEDIATE STUDS. WHERE 3" NAIL 5PAGIN6 15 SPECIFIED AT PANEL EDGE5, USE 1-1/2" Sd
SHORT NAILS OR 3X STUDS WITH 8d COMMON NAILS. FOR 2" NAIL 5PAGIN6, USE 3X STUDS
AND 5TA66ER PANELS. WHERE PLYWOOD 15 2 51DE5 OF WALL, JOINTS TO FALL ON
SEPARATE 5TUD5 ON EACH SIDE.
FLOOR PLYWOOD - USE 8d COMMON NAILS ® 10" O.G. AT INTERMEDIATE SUPPORTS, 6" O.G.
AT ALL PANEL ED6E5 AND 4" O.G. AT ALL SHEAR WALL5, UNLE55 OTHERWISE 5HOWN ON PLANS.
FLOOR JOISTS - J015T PARRALLEL TO FLOOR OPENINC75 AND EXTERIOR WALL5 SHALL BE
GRO55 BLOCKED AT 45" O.G. ® EDGES W/ (4) IOd NAILS FOR THE FIRST BAY.
3" x 3" x 1/4" SQUARE WASHERS AT ALL ANCHOR BOLTS. PLATE WA5HER5 TO BE INSTALLED WITHIN
1/2" OF SHEATHING
7/16" 05B OR PLYWOOD SHEATHING - STAPLE SCHEDULE
ALLOWABLE SHEAR VALUES WITH HEM FIR #2 STUDS
2" Ib 6A. 5TAPLE5 ® 15 &A. STAPLES ® 14 &A. STAPLES
3" O.G. - 250 #/ft. 4" O.G. - 280#/ft. 4" O.G. - 303#/ft.
2" O.G. - 360#/ ft. 2-1/2" O.G. - 430#/ft. 3" O.G. - 390#/ft.
4" O.G. AND IOd NAILS 2" O.G. - 504#/ft.
® 6" O.G. - 620#/ft.
I
_
FIELD 5PAGIN6: 12" O.G. NAILS 4 STAPLES.
HOLDOWNS - INSTALL 51MP50N HOLD0WN5 OR USP HOLDOWN5 AT THE END OF SHEAR WALL5
WHEN 5HOWN ON DRAWIN65.
PER PLAN, 51MP50N 5THD14 OR USP 5TAD14 51MP50N M5T36 OR LISP MST156
51MP50N M5T48 OR LISP K5T248 51MP50N HDUB OR U5P TDXIO 06" ANCHOR BOLT MIN.
51MP50N M5TG4853 OR LISP M5TGB4B3 24" EMBEDMENT, 3" BOLT INTO (3) 2x4(b))
CLIENT:
NASH&ASSOCIATES
SEISMIC ANALYSIS
PROJECT:
ARCHITECTS
PER IBC 2015
DATE:
NAME:
Weight of Building:
Roof Assembly.
Asphalt Shingles - 2.00 #/ft
Felt - 0.15 #/ft
1/2" Plywood - 1.50 #/it
Trusses 0 24" o.c. - 1.75 #/ft
R-38 Insulation - 2.35 #/it
1/2" GWB Ceiling - 2.00 #/ft
Cedar Shakes -
Felt -
1/2" Plywood -
Trusses 0 24" c.c.
R--30 Insulation -
1/2" GWB Ceiling -
2.25 #/ft
0.15 #/it
1.50 #/it
- 1.75 #/it
2.25 #/it
2.00 #/it
Tile - 9.50 #/it
Felt - 0.15 #/ft
1/2" Plywood - 1.50 #/it
Trusses ® 24" o.c. - 1.75 #/it
R-30 Insulation - 2.25 #/ft
1/2" GWB Ceiling - 2.00 #/it
Total
Use
9.75 #/ft
10.00 #/ft
Total
Use
9.90 #/ft
10.00 #/ft
Total 17.90 #/ft
Use 16.00 #/it
1st & 2nd Floor Assembly.
Caret / Pad -
0.50 #/ft
Hardwood -
2.50 #/ft
3/4' T&G Plywood -
2x10 ® 16" o.c. -
1/2" GWB Ceiling -
2.50 #/ft
2.30 #/ft
2.00 #/ft
3/4" T&G Plywood
2x10 @ 16" o.c. -
1/2" GWB Ceiling -
- 2.50 #/ft
2.30 #/ft
2.00 #/it
Total
Use
7.30 #/ft
10.00 #/ft
Total
Use
9.30 #/ft
10.00 #/ft
Interior Wall Assembly:
Exterior Wall Assembly:
1/2" GWB -
2X4 ® 16" o.c. -
1/2" GWB -
Total
Use
2.00 #/ft
1.10 #/ft
2.00 #/ft
5.10 #/ft
8.00 #/ft
3/4" Wood Siding -
1/2" Plywood -
2x8 ® 16" o. c. -
R-21 Insulation -
1/2" GWB -
2.30 #/it
1.50 #/ft
1.37 #/ft
2.10 #/ft
2.00 #/ft
Total
9.27 #/ft
Use
10.00 #/ft
4" Brick Veneer -
+ 3.20 #/ft
8003 118th Ave. NE. Kirkland, WA 98033 (425)
828-4117
WWW. NASH-ARCHITECTS. COM
7A=��
CLIENT:
-ASSOCIATES
SEISMIC ANALYSIS
PROJECT:
CHITECTS
PER IBC 2015
DATE:
NAME:
2
2nd Level:
Roof: Asphalt / Cedar Shake 10 #/ft x 2386 SF = 23860
Tile 18 #Ift x SF = 0
L 1/2 (h)
Exterior Walls 245 x 10 #/SF x 4.5 = 11025 (E2)
Interior Walls: 90 x 8 #/SF x 4.5 = 3240 (12)
Total: = 38125 or 38.1 k
1st Lewl:
Roof: Asphalt / Cedar Shake 10 #/ft x -1167 SF = -11670
2nd Floor: 18 #/ft x 2386 SF = 42948
L 1/2 (h) (E2)
Exterior Walls: 220 x 10 #/SF x 4.5 + 11025 = 20925 (El)
(12)
Interior Walls: 120 x 8 NSF x 4.5 + 3240 = 7560 (11)
Total: 59763 or 59.8 k
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117
WWVP. NASH—ARCHITECTS. COM
CLIENT:
NASx & ASSOCIATES
SEISMIC ANALYSIS
PROJECT:
ARCHITECTS
PER IBC 2015
DATE:
NAME:
5
Redundancy Factor (p):
1. MAXIMUM ALLOWABLE WALL SHEAR FOR P<=1
VUMAX = (2)(VACCSTORY)/AB',*
2( 12.8 ) 25.6
Vumax = = 34.9 = 0.7
1219
2. MAXB[UM ACTUAL SHEAR
VUMAX = LARGEST SEISMIC WALL SHEAR
0.7 > 0.357
3. P = 2—[2(VACCSTORI)/(VUMAX)(AB1A)
P = 2 - [ 2( 12.8 ) ] = 1
( 0.7 * 34.9 )
8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117