SPECIAL INSPECTIONS PERFORMED COMBINED�Q---Kmzan&Associates, Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection DATE: 10/18/2019 PROJECT #: 09619085 PROJECT: Edmonds-Woodway HS Turf Conversion LOCATION: 7600 212th Street SW KA P.M.: Corbett Mercer Field Data Concrete: 3310 1 Other: CONCRETE REPORT NO.: 09619085CR101819-TR CONTRACTOR: Wyser PERMIT #: BLD20180708 INSPECTOR: Taylor Rooney JURISDICTION: City of Edmonds WEATHER: Cloudy TEMP: 50 ° Supplier:1 CalPortland Plant No. 1 260 Site Mix: Slump Mix Air Unit Time Truck # Ticket # % Air Inch Temp (F) Temp (F) Weight 11:15 1 7427 1 93409 4.3 1 4.25 1 71 ° 1 53 ° Location: Placement Area Batting cage footing s all pad footings and grade beams in the sotraaer locker area Remarks: Placed by pump and boom, mechanically consolidated Please Refer To Field Repot Number : 09619085DFR1 01 82019TR Inspector :1 Taylor Rooney Reported Batch DATA Cement Type I -I I Design Actual MIX No. 10 d3 3310 Cam. Lbs. 5620 F. Ash lbs. C. Agg. Lbs #57 19040 C. Agg. Lbs C. Agg. Lbs Sand lbs 13040 Water 262 Air Ent. I Daraval I 70oz (oz/cwt.)l r Water Added On Job Site (Gals.) Field Test ASTM Method C172 C143 C138 C1064 C231 C31 Other Laboratory Data Design Strength: 4000 Qa 28 days I Date Specimens Rec'd: Cyl. Code Test Date Field Cure Age Dia. Area Wt. # Max Load Comp. Strength Set # Tested By Brk Typ Test Method ASTM C39 ASTM C109 ASTM C617 ASTM C1231 ASTM C1019 OTHER 10/25/19 7 11/15/19 28 11/15/19 1 28 1 1 11/15/19 28 H Test Results Conforming Remarks: Results Reviewed By: Date: Codes for Break Types: 1 2 j 3 4 5 6 Offices Serving The Western United States Concrete Report Effective 02/22/2018 Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report Is prepared for the exclusive use of the client, and may not be reproduced In any format without the written permission of the client and Krazan & Associates. This report Indicates our Inspector's observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. Page 1 of 1 � an&Ass ociate s, Inc. Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection Field Report NO.: 09619085DFR10182019TR-1 DATE: 10/18/2019 Set Count: 1 CONTRACTOR: Wyser Construction PROJECT #: 09619085 PERMIT #: BLD20180708 PROJECT: Edmonds-Woodway HS Turf Conversion INSPECTOR: Taylor Rooney LOCATION: 7600 212` Street SW JURISDICTION: City of Edmonds KA P.M.: Jeff Mercer WEATHER: Cloudy TEMP: 50' F Inspected reinforcing steel for the batting cage foundation verified all pad footings and the grade beams for the storage area of the building (grade beams in the batting cage area will be completed at a later date). Reinforcing steel was checked for size, grade, spacing, lap, count, clearance, and placement. Additionally verified embedded item (anchors bolts). For depth, template installation, and hardware (nuts/washers). Footings and grade beams appeared to conform to the approved plans and specifications. Inspected concrete placement for the batting cage foundation verified all pad footings and the grade beams for the storage area of the building. CalPortland delivered 24yd3 of approved concrete mix 3310. Footings were placed by pump and boom and mechanically consolidated. One set of strength test cylinders were cast from this mix. Concrete placement appeared to conform to the approved plans and specifications. Reviewed By: ASTM Test #: Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and %razan & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. J_ & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING . ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION December 2, 2019 Mr. Nick Chou (E-Mail) EDMONDS SCHOOL DISTRICT NO. 15 20420 68t1i Ave. W Edmonds, WA 98036 RE: CONSTRUCTION TESTING AND INSPECTION Edmonds-Woodway High School Synthetic Turf Conversion 7600 212''' St. SW Edmonds, Washington Dear Mr. Chou, KA No. 096-19085 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, ZAN & ASSOCIATES, INC. Corbe W. Mercer Project Manager/Lab Manager Pacific Northwest Division CWM/lkj CC: DA HOGAN (E-MAIL) W YSER CONSTRUCTION (E-MAIL) 4303 1981'' Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09619085 DFR.doc Page 1 of 1 �t1C.LL��L1&Associates, Inc. Geotechnical Engineering a Environmental Engineering Construction Testing and Inspection Field Report NO.: 09619085DFR11262019ZZ DATE: 11/26/2019 Set Count: CONTRACTOR: W ser PROJECT #: 09619085 PERMIT #: PROJECT: Edmonds-Woodway H.S. Turf Conversion INSPECTOR: Zelalem Zerihun LOCATION: 7600 2121 street SW, Seattle, WA JURISDICTION: City of Edmonds KA P.M.: Jeffrey S. Mercer WEATHER: Cloudy TEMP: 45' F Krazan & Associates, Inc. representative visited the above -said project and performed periodic special inspection for a high strength bolting. We reviewed GRACO Building System drawings for batting cage structure and determined the type of approved joints of rigid frames which is Turn -of -the -nut method (pre -marked). We checked all bolted connections and ensured that the high strength bolts are marked as A325 as per ASTM. The bolts were pre -marked & turned 1/3 properly and acceptable as per AISC 360. All plies of rigid frame connections are in contact and no gap seen around the bolts. Reviewed By: G I ASTM Test #: Asset Number(s): To the best of my knowleci fe, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the acclusive use of the client. This report may not be reproduced in any forma[ without the written permission of the client and YG & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site.