SPECIAL INSPECTIONS COMBINED SERVICE7 =' azan_ & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION . FORENSIC INVESTIGATION September 1, 2020 Mr. Marc Ikegami DOUG'S LYNNWOOD MAZDA 22130 Hwy 99 Edmonds, WA 98026 RE: CESCL STORMWATER INSPECTION SERVICES FOR: Doug's Lynnwood Mazda Service Center 22130 Highway 99 Edmonds, WA Dear Mr. Ikegami; KA No. 094-20001 In accordance with your request and authorization, our firm performed stormwater quality monitoring for the above -referenced project. The inspection was performed on the date(s) indicated below. The following report is attached: • CESCL Field Report dated August 28, 2020 If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. ordan Kain Environmental Department Manager Lynnwood, WA JK/ep 4303 19811 Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09420001 CESCL Cover Letter.doc Page 1 of 2 "WI( an&Associates,Inc. Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection Field Report NO.: 09420001DFR8282020JK DATE: 8/28/2020 Set Count: CONTRACTOR: Wilcox PROJECT #: 09420001 PERMIT #: PROJECT: Mazda Service Center / Hyundai Sales INSPECTOR: Jordan Kain LOCATION: 22130 WA 99 JURISDICTION: Edmonds KA P.M.: Jordan Kain WEATHER: Clear TEMP: 70 Teinvorary Erosion and Sediment Control TESC Inspection Mazda Service Center: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Mazda Service Center. Eastern site perimeter needs to be swept clear of sediment prior to a rain event. (see photo) Stormwater drain inserts are relatively clean and free of debris. Sidewalks are present along the northern site perimeter which act as a conveyance channel and prevent stormwater from running onto/off the site. Rainwater. Straw wattles are present along the eastern site perimeter. No gaps are present between the site and eastern asphalt. Contractor needs to maintain sediment -free asphalt through periodic sweeping and general site tidiness. Erosion and sediment control techniques include crushed rock for truck tires, silt fences along the eastern, straw wattles, plastic covering soil piles, and storm drain inserts. Below is a visual r resentation of the site conditions at the time of inspection. _ r . Hyundai Sales Building: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Hyundai Sales Building. Site perimeter appears effective in preventing sediment from running off -site. Asphalt should still be swept periodically to eliminate sediment issues due to truck traffic. Soil piles have received full plastic covering. Perimeter sidewalks work is contained by curbing. Temporary erosion and sediment control techniques include tires, silt fences along the eastern, straw wattles, plastic covering soil piles, and storm drain inserts. Below is a visual representation of the site conditions at the time of inspection. Below is a visual representation of the site conditions at the time of inspection. Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client This report may not be reproduced in any format without the written permission of the client and Krazen & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibilityfor validity of results. The same information has been provided by others on site Page 2 of 2 :Irk _= &Associates,Inc. Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection Field Report NO.: 0942000 1 DFR8282020JK Reviewed B,,: ASTM Test #: Asset To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Kaman & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. KlaZall& ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Pagel of 3 Project Name: Mazda Service Center / Hyundai Sales Project Address: 22130 Highway 99 Permit Number: Project Number:094-20001 Date: 8/28/20 1 Time: 1:00 PM Inspector: Jordan Kain, CESCL Site BMPs Overall Condition Need Repair?! Commenta/Obser vations ClearingLimits • Buffer Zones around sensitive areas ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No NA • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑Good ❑Fair ❑Poor ❑ Yes ❑ No Construction/Access Roads • Stabilized site entrance ❑ Good ❑Fair ❑ Poor ❑ Yes [—]No • Stabilized roads/ arkin g areas El Good ❑ Fair El Poor El Yes El No Parking on west end of the site • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Flow Rates • Swale ❑Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Dike ❑ Good ❑ Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Sediment Pond ❑ Yes ❑No • Sediment Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor El Yes ❑ No Install Sediment Controls • Sediment PondlTr ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Silt fencing have Silt Fence ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No been properly installed. • Straw Bale Barriers ❑ Good ❑ Fair ❑ Poor ❑ Yes❑ No • Straw Wattles ❑ Good ®Fair ❑Poor El ❑ No New straw wattles in place on both sites • Sandbags ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Preserve Vegetation/Stabilize Soils • Nets and Blankets ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Mulch ® Good ❑ Fair ❑ Poor ❑ Yes ® No • Seeding ® Good ❑ Fair ❑ Poor ❑ Yes ® No Plastic sheeting is present on the soil • Plastic Sheeting❑Fair ® Good El Yes ® ❑ No piles. More sheeting may be necessary during construction _ processes 4303 198" Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER - SITE INSPECTION CHECKLIST • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Slopes • Terrace ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Pipe Slope Drains ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Drain Inlets • Inserts ❑ Good ® Fair ❑Poor ® Yes ® No Drain inserts are in place Stabilize Channels and Outlets • Conveyance Channels ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • EnerW Dissipators ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Pollutants • Chemical Storage Area ® Good ❑ Fair [I Poor El Yes ® No No chemicals resent • Concrete Handling ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor L ❑ Yes ❑ No Control De -Watering • Baker Tank ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Project Name: Dou 's Lynnwood Mazda Service Center Project Number:094-20001 _ Date: 8/28/20 Time: 1:00 PM Project Address: 22130 Highway 99 Permit Number: N/A Inspector: Jordan Kain, CESCL Will existing BMPs need to be modified or removed, or other BMPs installed? No If YES, list the action items to be completed on the following table: Actions to be com Ieted Date Completed Initials 1. 2. 3. 4. 5. 6. Weather conditions at the time of the inspections were clear and 70 degrees. Approximate amount of precipitation since last inspection: __0.00_inches and precipitation in the previous 24 hours*: _0.00 inches *based on an on -site rain gauge or local weather data. Describe discharging stormwater, if present. Note the presence of suspended sediment, "cloudiness", discoloration, or oil sheen. Was water quality sampling part of this inspection? No Krazan & Associates, Inc. With Offices Serving the Western United States j -��..KraZ� & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST If YES, record results below attach a separate sheet, if necessary): Pam meter Method Select One Result Units Turbid! ❑ Tube ® Meter ❑ Laboratory NTU (cm, if tube used) pH Standard Units H ® Paper ❑ Kit ❑ Meter Is the site in compliance with the SWPPP and the permit requirements? YES If no, indicate tasks necessary to bring site into compliance on the "Actions to be Completed" table above, and include dates each job WILL BE COMPLETED. If no, has the non-compliance been reported to the Dept. of Ecology? YES / NO If no, should the SWPPP be modified: YES / NO Sign the following certification: "I certify that this report is true, accurate, and complete, to the best of my knowledge and belief. " Inspection report completed on: 8/28/20 B p p P y: sh.nature Title/Qualification of Inspector: CESCL Name: Jordan Kain (print name) Krazan & Associates, Inc. With Of Serving the Western United States =�<�a.. za_ & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION • FORENSIC INVESTIGATION September 28, 2020 Mr. Marc Ikegami DOUG'S LYNNWOOD MAZDA 22130 Hwy 99 Edmonds, WA 98026 RE: CESCL STORMWATER INSPECTION SERVICES FOR: Doug's Lynnwood Mazda Service Center 22130 Highway 99 Edmonds, WA Dear Mr. Ikegami; KA No. 094-20001 In accordance with your request and authorization, our firm performed stormwater quality monitoring for the above -referenced project. The inspection was performed on the date(s) indicated below. The following report is attached: • CESCL Field Report dated September 25, 2020 If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRA7.AN & ASSOCIATES, INC. Jo � Kain Elfvironmental Department Manager Lynnwood, WA JK/ep 4303 1981b Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09420001 CESCL Covcr Lmer.doc Page 1 of 2 %dKmz &Associates, Inc. Field Geotechnical Engineering * Environmental Engineering Report NO.: 09420041DFR9252020JK Construction Testing and Inspection DATE: 9/25/2020 Set Count: CONTRACTOR: Wilcox PROJECT #: 09420001 PERMIT #: PROJECT: Mazda Service Center / HVL Mdai Sales INSPECTOR: Jordan Kain LOCATION: 22130 WA 99 JURISDICTION: Edmonds KA P.M.: Jordan Kain WEATHER: Cloudy TEMP: 70 Temporary Erosion and Sediment Control TESL Ins ection Mazda Service Center: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Mazda Service Center. Site has received asphalt which has eliminated much of the previously exposed soils.(see photo) While on -site, contractor was placing straw wattles, laid straw and applying grass seeds to western sloped appears (see phpto) If stormdrains are connected to the stormwater system sediment needs to be removed and drains need to remain protected. Sidewalks are present along the northern site perimeter which act as a conveyance channel and prevent stormwater from running onto/off the site. Contractor needs to maintain sediment -free asphalt through periodic sweeping and general site tidiness. A turbidity sample was taken at the lower elevation catch basin between the Mazda and Hyundai builds. Erosion and sediment control techniques include crushed rock for truck tires, silt fences along the eastern, straw wattles, plastic covering soil piles, and storm drain inserts. Below Hypndai Sales Building: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Hyundai Sales Building. Site requires sweeping and removal of roadway sediment (see photos). Exposed soils and lot traffic spread sediment throughout the drive area. It is necessary to remove sediment from the asphalt to prevent sediment from running into storm drains. All soils piles need to remain covered when left unworked. Site perimeter appears effective in preventing sediment from running off -site. Temporary erosion and sediment control techniques include tires, silt fences along the eastern, straw wattles, plastic covering soil piles, and storm drain inserts. Below is a visual representation of the site conditions at the time of inspection. Below is a visual representation of the site conditions at the time of inspection. Offices Serving the Western United States, Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittaL By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. Page 2 of 2 == azJ&Associates,Inc. Geotechnical Engineering *Environmental Engineering Construction Testing and Inspection Field Report NO.: 09420001DFR9252020JK ASTM Test #: Asset To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this reportis prepared for the exclusive use of the client. This reportmay not be reproduced in any format without the written permission of the client and Kra & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. !■. V_ ALL ari- & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Pagel of 3 Project Name: Mazda Service Center / Hyundai Sales Project Number:094-20001 Project Address: 22130 Highway 99 Date: 9/25/20 1 Time: 1:00 PM Permit Number: Inspector: Jordan Kain, CESCL Site BMPs Overall Condition Need Repair? Comments/Obser vations Clearin; ; Limits • Buffer Zones around sensitive areas ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No NA • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Construction/Access Roads ❑ Good ❑Fair ❑ Good ❑ Fair ❑ Good ❑ Fair ❑ Poor ❑ Poor ❑ Poor ❑ Yes ❑No ❑ Yes No ❑ Parking on west end of the site _ • Stabilized site entrance • Stabilized roads/ arkin areas P g • ❑ Yes ❑ No Control Flow Rates • Swale ❑Good ❑ Fair ❑ Good ❑ Fair ❑ Poor ❑ Poor ❑ Yes ❑ No ❑ Yes ❑ No • Dike ❑ Good ❑ Fair ❑ • Sediment Pond ❑ Good ❑ Fair ❑ Good ❑ Fair Poor ❑ Poor ❑ Poor ❑ Yes ❑No ❑ Yes ❑ No ❑ Yes ❑ No • Sediment Trap • Install Sediment Controls • Sediment Pond/Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Silt fencing have Silt Fence ❑ Good ❑ Fair ❑ Poor j ❑ Yes ❑ No been properly installed. • Straw Bale Barriers ❑ Good ❑ Fair ❑ Poor ❑ Yes[—] No • Straw Wattles ❑ Good ® Fair ❑ Poor ❑ Yes No ❑ New straw wattles in place on both sites • Sandbags ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Preserve Vegetation/Stabilize Soils ❑ Good ❑ Fair ®Good ❑ Fair ❑ Poor ❑ Poor ❑ Yes ❑ No ❑ Yes ® No • Nets and Blankets • Mulch • Seeding N Good ❑ Fair ❑ Poor ❑ Yes ® No • Soils piles need to Plastic Sheeting ® Good ❑ Fair ❑ Poor N Yes ❑ No be covered if left unworked. • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Slopes 4303 198' Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States ." J -a & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST • Terrace ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Pipe Slope Drains ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Drain Inlets Poor ® Yes ® No rain inserts are in • Inserts El Good ® Fair ElD place _ Stabilize Channels and Outlets • Conveyance Channels ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Energy Dissi ators ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Pollutants • Chemical Storage Area g ® Good ❑ Fair ❑ Poor ❑ Yes ® No ❑ Yes ❑ No No chemicals present Eco-Pan on -site • Concrete Handling ❑ Good ❑ Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor • ❑ Yes ❑ No Control De -Watering • Baker Tank ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Project Name: Dou 's L nnwood Mazda Service Center Project Number:094-20001 Date: 9/25/20 1 Time: 1:00 PM Project Address: 22130 Hi hwav 99 Permit Number: N/A Inspector: Jordan Kain, CESCL Will existing BMPs need to be modified or removed, or other BMPs installed? Yes 11 1 E6, list the action items to be completed on the following table: Actions to be completed Date Completed Initials 1. Sweep asphalt at the Hyundai site 2. 3. 4. 5. �- 6. Weather conditions at the time of the inspections were rain and 60 degrees. Approximate amount of precipitation since last inspection:—1.91_inches and precipitation in the previous 24 hours*: _0.75 inches *based on an on -site rain gauge or local weather data. Describe discharging stormwater, if present. Note the presence of suspended sediment, "cloudiness", discoloration, or oil sheen. Was water quality sampling part of this inspection? No If YES, record results below (attach a separate sheet, if necessary): Parameter I Method (Select One) Result I iTnitc Krazan & Associates, Inc. With Offices Serving the Western United States KraZall & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Turbidity ❑ Tube ® Meter ❑ LaboratorG NTU cm, if tube used H —®—Paper ❑ Kit LJ Meter pH Standard Units Is the site in compliance with the SWPPP and the permit requirements? YES If no, indicate tasks necessary to bring site into compliance on the "Actions to be Completed" table above, and include dates each job WILL BE COMPLETED. If no, has the non-compliance been reported to the Dept. of Ecology? YES / NO If no, should the SWPPP be modified: YES / NO Sign the following certification: "I certify that this report is true, accurate, and complete, to the best of my knowledge and belief. " Inspection report completed on:_ 9/25/20 __—BY: .si nature Title/Qualification of Inspector: CESCL Name: Jordan Kain (print name) Krazan & Associates, Inc. With Offices Serving the Western United States Krazan- & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION • FORENSIC INVESTIGATION October 13, 2020 Mr. Marc Ikegami DOUG'S LYNNWOOD MAZDA 22130 Hwy 99 Edmonds, WA 98026 RE: CESCL STORMWATER INSPECTION SERVICES FOR: Doug's Lynnwood Mazda Service Center 22130 Highway 99 Edmonds, WA Dear Mr. Ikegami; KA No. 094-20001 In accordance with your request and authorization, our firm performed stormwater quality monitoring for the above -referenced project. The inspection was performed on the date(s) indicated below. The following report is attached: • CESCL Field Report dated October 9, 2020 If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, KRAZAN & ASSOCIATES, INC. Jordan Kam f Environmental Department Manager Lynnwood, WA JK/ep 4303 19811 Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09420001 CESCL Cover Lctter.doc Page 1 of 1 11(fUZan8tAssoeiates,Inc. Field Geotechnical Engineering . Environmental Engineering Report NO.: 09420001DFR9252020JK Construction Testing and Inspection DATE: 10/9/2020 Set Count: CONTRACTOR: Wilcox PROJECT #: 09420001 PERMIT #: PROJECT: Mazda Service Center / H dam Sales INSPECTOR: Jordan Kain LOCATION: 22130 WA 99 JURISDICTION: Edmonds KA P.M.: Jordan Kain WEATHER: Cloud TEMP: 65' F Temporary Erosion and Sediment Control (TESQ Inspection Mazda Service Center: The Mazda Service Center site has completed construction and no exposed soils exist on site. Hyundai Sales Building: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Hyundai Sales Building. The site has added asphalt pavement since the last inspection which has eliminated much of the previously exposed soils. The roadway has sediment throughout and needs to be swept clear prior to a rain event or direct runoff away from storm drains. All soils piles need to remain covered when left unworked. Site perimeter appears effective in preventing sediment from running off -site. Below is a visual representation of the site conditions at the time of inspection. Reviewed B� : ASTM Test #: Asset Numbers}: To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. S 11 herintendent/R� ji resentative: Technician: ■ Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittaL By signing this report, our inspector does not accept resporuibility for validity of results. The same information has been provided by others on site. ="�"KraZan & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Pagel of 3 Project Name: Mazda Service Center / Hyundai Sales Project Number:094-20001 Project Address: 22130 Highway 99 Date: 10/9/20 1 Time: 1:00 PM Permit Number: Inspector: Jordan Kain, CESCL Site BMPs Overall Condition Need Repair? Comments/Obser vations Clearing Limits • Buffer Zones around sensitive areas ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No NA • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Construction/Access Roads • Stabilized site entrance ❑ Good ❑Fair ❑ Poor ❑ Yes ❑No ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Stabilized roads/parking areas of the g Parkint n west end • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Flow Rates ❑ Yes ❑ No • Swale ❑Good ❑ Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor • Dike ❑ Yes ❑ No • Sediment Pond ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑No ❑ Yes ❑ No Sediment Trap ❑ Good ❑ Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor • ❑ Yes ❑ No Install Sediment Controls ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No I ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Sediment Pond/Trap _ • Silt Fence • Straw Bale Barriers ❑ Good ❑ Fair ❑ Poor ❑ Yes❑ No • Straw Wattles ❑ Good ® Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Sandbags ❑ Yes ❑ No Preserve Vegetation/Stabilize Soils ❑ Good ❑ Fair ❑ Poor ' El Yes El No I _ ® Good ❑ Fair ❑ Poor ❑ Yes ® No • Nets and Blankets _ • Mulch • Seeding ® Good ❑ Fair ❑ Poor ❑ Yes ® No • Soils piles need to Plastic Sheeting N Good ❑ Fair ❑ Poor ® Yes ❑ No be covered if left ❑ Yes ❑ No unworked. • ❑ Good ❑ Fair ❑ Poor Protect Slopes • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No 4303 198" Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States -�....Kxaza l_ & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Terrace • Pipe Slope Drains ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Drain Inlets • Inserts ❑ Good ® Fair ❑ �0� ® Yes ® No Drain inserts a�in place Stabilize Channels and Outlets • Conveyance Channels ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Energy Diss' ators ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor [:]Yes ❑ No Control Pollutants Yes No El® No chemicals • Chemical Area Storage ® Good El Fair ❑ Poor g present • Concrete Handling ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor Control De -Watering • Baker Tank ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Project Name: Dou 's Lynnwood Mazda Service Center Project Number:094-20001 Date: 10/9/20 1 Time: 1:00 PM Project Address: 22130 Highway 99 Permit Number: N/A Inslector: Jordan Kain, CESCL Will existing BMPs need to be modified or removed, or other BMPs installed? Yes If YES, list the action items to be completed on the following table: Actions to be completed Date Completed Initials 1. Sweep asphalt at the H dai site 2. 3. 4. 5. 6. Weather conditions at the time of the inspections were cloudy and 65 degrees. Approximate amount of precipitation since last inspection:—0.00_inches and precipitation in the previous 24 hours*: _0.00 inches *based on an on -site rain gauge or local weather data. Describe discharging stormwater, if present. Note the presence of suspended sediment, "cloudiness", discoloration, or oil sheen. Was water quality sampling part of this inspection? No If YES, record results below (attach a separate sheet, if necessarv): Parameter Method Select One Result Units 71 Turbidity Lj Tube ® Meter Lj Laboratory I I NTU (cm, if tube used) Krazan & Associates, Inc. With Offices Serving the Western United States --^. <UA_ & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST 1�9 Paper U Kit U Meter I PH Standard Units Is the site in compliance with the SWPPP and the permit requirements? YES If no, indicate tasks necessary to bring site into compliance on the "Actions to be Completed" table above, and include dates each job WILL BE COMPLETED. If no, has the non-compliance been reported to the Dept. of Ecology? YES / NO If no, should the SWPPP be modified: YES / NO Sign the following certification: "I certify that this report is true, accurate, and complete, to the best of my knowledge and belief. " Inspection report completed on: 10/9/20 By:(signature) Title/Qualification of Inspector: _ CESCL _ Name: an Kain rinf name Krazan & Associates, Inc. With Offices Serving the Western United States ==--1aZa_J & ASSOCIATES, INC. GEOTECITNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION • FORENSIC INVESTIGATION October 20, 2020 Mr. Marc Ikegami DOUG'S LYNNWOOD MAZDA 22130 Hwy 99 Edmonds, WA 98026 RE: CESCL STORMWATER INSPECTION SERVICES FOR: Doug's Lynnwood Mazda Service Center 22130 Highway 99 Edmonds, WA Dear Mr. Ikegami; KA No. 094-20001 In accordance with your request and authorization, our firm performed stormwater quality monitoring for the above -referenced project. The inspection was performed on the date(s) indicated below. The following report is attached: • CESCL Field Report dated October 16, 2020 If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully submitted, TES, INC. W Jor d trdEn roe � _ntal Department Manager Lynnwood, WA JK/ep 4303 198'h Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09420001 CESCL Cover Letter.doc Page 1 of 1 KraZan&Associate s,Inc. Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection Field Report NO.: 09420001DFR9252020JK DATE: 10/16/2020 Set Count: CONTRACTOR: Wilcox PROJECT #: 09420001 PERMIT #: PROJECT: Mazda Service Center / HN-undai Sales INSPECTOR: Jordan Kain LOCATION: 22130 WA 99 JURISDICTION: Edmonds KA P.M.: Jordan Kain WEATHER: Cloudy TEMP: 60 Temi)orary Erosion and Sediment Control TESL Ins ection Mazda Service Center: The Mazda Service Center site has completed construction and no exposed soils exist on site. Hyundai Sales Building: Krazan and Associates representative was on site for the once weekly CESCL inspection at the Hyundai Sales Building. The site has added asphalt pavement since the last inspection which has eliminated much of the previously exposed soils. As nearly all of the soils have been stabilized or removed from the site, Krazan anticipates one final inspection once site cleaning has occurred. Below is a visual representation of the site conditions at the time of inspection. II Reviewed By: k I ASTM Test #: I I Asset Number(s To the best of my knowledge, t e above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prim to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. •� �.�7��7�-�y -�" RL�GLL L &ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Page l of 3 Project Name: Mazda Service Center / H undai Sales Project Address: 22130 Highway 99 Permit Number: Project Number:094-20001 Date: 10/16/20 1 Time: 1:00 PM Inspector: Jordan Kain, CESCL Site BMPs Overall Condition Need Repair? Comments/Obser vations Clearing Limits • Buffer Zones around sensitive areas ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No NA • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Construction/Access Roads • Stabilized site entrance ❑ Good Elf air ❑ Poor ❑ Yes ❑No ❑ Good ❑ Fair ❑ Poor ❑ ❑ Yes No Parking on west end Stabilized roads/jarkin areas of the site • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Flow Rates • Swale ❑Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Dike ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Sediment Pond ❑ Good ❑ Fair ❑ Poor ❑ Yes [:]No • Sediment Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Install Sediment Controls • Sediment Pond/Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Silt Fence ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Straw Bale Barriers ❑ Good ❑ Fair ❑ Poor ❑ Yes[—] No • Straw Wattles ❑ Good ® Fair ❑ Poor ❑ Yes ❑ No • Sandbags ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Preserve Vegetation/Stabilize Soils • Nets and Blankets ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Mulch ® Good ❑ Fair ❑ Poor ❑ Yes ® No • Seeding ® Good ❑ Fair ❑ Poor ❑ Yes ® No • Plastic Sheeting ® Good ❑ Fair ❑ Poor ® Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Slopes • ❑ Good ❑ Fair ❑ Poor ElYes ❑ No Terrace 4303 198" Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States �qWL_ 1 , 14(-aZa._ & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST • Pi e Slope Drains ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Drain Inlets • ❑ Good ® Fair ❑ Poor ® Yes ® No Drain inserts are in Inserts place Stabilize Channels and Outlets • Convevance Channels ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • EnerU Dissi ators ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Pollutants • Chemical Storas;eArea ® Good ❑ Fair ❑ Poor ❑ ® Yes No No chemicals present • Concrete Handling ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor Control De -Watering • Baker Tank ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Project Name: Dou 's Lynnwood Mazda Service Center Project Number:094-20001 Project Address: 22130 Highway 99 Date: 10/16/20 1 Time: 1:00 PM Permit Number: N/A Inspector: Jordan Kain, CESCL Will existing BMPs need to be modified or removed, or other BMPs installed? Yes If YES, list the action items to be completed on the following table: Actions to be com feted Date Completed Initials 1. Sweep asphalt at the Hyundai site 2. 3. 4. 5. 6. Weather conditions at the time of the inspections were cloudy and 60 degrees. Approximate amount of precipitation since last inspection:—2.19_inches and precipitation in the previous 24 hours*: _0.00 inches *based on an on -site rain gauge or local weather data. Describe discharging stormwater, if present. Note the presence of suspended sediment, "cloudiness", discoloration, or oil sheen. Was water quality sampling part of this inspection? No If YES, record results below (attach a separate sheet, if necessarv): j Parameter I Method (Select One) I Result I Units I Krazan & Associates, Inc. With Offices Serving the Western United States .:« :.� �r A aZa _l & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Turbidity F1 Tube ® Meter ❑ Laboratory NTU (cm, if tube used) H N Paper Kit ❑ Meter pH Standard Units Is the site in compliance with the SWPPP and the permit requirements? YES If no, indicate tasks necessary to bring site into compliance on the "Actions to be Completed" table above, and include dates each job WILL BE COMPLETED. If no, has the non-compliance been reported to the Dept, of Ecology? YES / NO If no, should the SWPPP be modified: YES / NO Sign the following certification: "I certify that this report is true, accurate, and complete, to the best of my knowledge and belief. " LInspection report completed on: 10/16/20 By: si nature Title/Qualification of Inspector: CESCL Name: rdan Kain rint name Krazan & Associates, Inc. With Offices Serving the Western United States 4 - KUM 0 1 --d KIaZan & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION • FORENSIC INVESTIGATION October 21, 2020 Mr. Marc Ikegami (E-Mail) DOUG'S LYNNWOOD MAZDA 22130 Hwy 99 Edmonds, WA 98026 KA No. 094-20001 RE: CESCL STORMWATER INSPECTION SERVICES FOR: Doug's Lynnwood Mazda Service Center — FINAL CESCL INSPECTION 22130 Highway 99 Edmonds, Washington Dear Mr. Ikegami; In accordance with your request and authorization, our firm performed stormwater quality monitoring for the above -referenced project. The inspection was performed on the date(s) indicated below. The following report is attached: • CESCL Field Report dated October 20, 2020 If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. Respectfully KRAZAN & INC. " JordanV6,' En)j4�roDepartment Manager LyfinA JYJep 4303 198" Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States 09420001 CESCL Cover Letter.doc Page 1 of 1 . tt.nr — K�an & A s s o c i a t e s, I n c. Geotechnical Engineering a Environmental Engineering Construction Testing and Inspection Field Report NO.: 0942000 1 DFR9252020JK DATE: 10/20/2020 Set Count: CONTRACTOR: Wilcox PROJECT #: 09420001 PERMIT #: PROJECT: Mazda Service Center / Hyundai Sales INSPECTOR: Jordan Kain LOCATION: 22130 WA 99 JURISDICTION: Edmonds KA P.M.: Jordan Kain WEATHER: Cloudy TEMP: 55 Temporary Erosion and Sediment Control TESC Ins ection Mazda Service Center: The Mazda Service Center site has completed construction and no exposed soils exist on site. Hyundai Sales Building Krazan and Associates representative was on site for the once weekly CESCL inspection at the Hyundai Sales Building. The site has contained all exposed soils through the use of landscaping. Previous sediment deposits sitting on the asphalt has been swept clean and no potential run-off sediment exists on -site. There are no sediment or erosion control issues remaining on the site and the site can be considered permanently stabilized. This report can be considered the closeout stormwater report for the site. Below is a visual representation of the site conditions at the time of inspection. Reviewed By: ASTM Test #: Asset Number(s): To the best of my knowledge, thefabove WAS performed in accordance with the approved plans, specifications and regulatory requirements. r Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission ofthe client and Kra7.an & Associates. This report indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site. �-`Krazairi & ASSOCIATES INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Pagel of 3 Project Name: Mazda Service Center / H undai Sales Project Address: 22130 H' hway 99 Permit Number: Project Number:094-20001 Date: 10/20/20 1 Time: 9:30 AM Inspector: Jordan Kain, CESCL Site BMPs Overall Condition Need Repair? Comments/Obser vations Clearing Limits • Buffer Zones around sensitive areas ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No NA • ❑ Good ❑ Fair ❑ Poor ❑ Yes [:]No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Construction/Access Roads • Stabilized site entrance ❑ Good ❑Fair ❑ Poor ❑ Yes ❑No • Stabilized roads/ arkin P g areas ❑ Good ❑ Fair ❑Poor El ❑ No Parking on west end of the site • ❑Good ❑Fair ❑Poor ❑Yes ElNo Control Flow Rates • Swale ❑Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Dike ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Sediment Pond ❑ Good ❑ Fair ❑ Poor ❑ Yes []No • Sediment Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Install Sediment Controls • Sediment Pond/Trap ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Silt Fence ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Straw Bale Barriers ❑ Good ❑ Fair ❑ Poor ❑ Yes[:] No • Straw Wattles ❑ Good ® Fair ❑ Poor ❑ Yes ❑ No ❑ Yes ❑ No • Sandbags ❑ Good ❑ Fair ❑ Poor Preserve Vegetation/Stabilize Soils _ • Nets and Blankets ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Mulch ® Good ❑ Fair ❑ Poor ❑ Yes N No ❑ Yes ® No El Yes ❑ No • Seeding ® Good ❑ Fair ❑ Poor ® Good El Fair El Poor • Plastic Sheeting_ _ • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Slopes _ • Terrace ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No 4303 198"' Street SW • Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Offices Serving the Western United States _. i. ar C1 & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST • Pipe Slope Drains ❑ Good ❑ Fair ❑ Poor ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No ❑ Yes ❑ No • • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Protect Drain Inlets • Inserts ❑ Good ® Fair El Poor ® Yes ®No Drain inserts are in place Stabilize Channels and Outlets • Conveyance Channels ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Energy Dissi ators ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control Pollutants • Chemical Storage Area ®Good El Fair ❑Poor El Yes ® No No chemicals present • Concrete Handling ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No Control De -Watering • Baker Tank ❑ Good ❑ Fair ❑ Poor ❑ Yes ❑ No • Project Name: Dou 's Lynnwood Mazda Service Center Project Number:094-20001 Project Address: 22130 Highway 99 Date: 10/20/20 Time: 9:30 AM Permit Number: N/A Inspector: Jordan Kain, CESCL Will existing BMPs need to be modified or removed, or other BMPs installed? No If YES, list the action items to be completed on the following table: Actions to be completed Date Completed Initials 1. 2. 3. 4. 5. 6. Weather conditions at the time of the inspections were cloudy and 55 degrees. Approximate amount of precipitation since last inspection:—0.27_inches and precipitation in the previous 24 hours*: _0.00 inches *based on an on -site rain gauge or local weather data. Describe discharging stormwater, if present. Note the presence of suspended sediment, "cloudiness", discoloration, or oil sheen. Was water quality sampling part of this inspection? No If YES, record results below (attach a separate sheet, if necessary): Parameter Method Select One Result Units Turbidity ❑ Tube ® Meter ❑ Laboratory NTU (cm, if tube used) PH ® Paper ❑ Kit ❑ Meter pH Standard Units Krazan & Associates, Inc. With Offices Serving the Western United States _Gizall & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION CONSTRUCTION STORMWATER — SITE INSPECTION CHECKLIST Is the site in compliance with the SWPPP and the permit requirements? YES If no, indicate tasks necessary to bring site into compliance on the "Actions to be Completed" table above, and include dates each job WILL BE COMPLETED. If no, has the non-compliance been reported to the Dept. of Ecology? YES / NO If no, should the SWPPP be modified: YES / NO Sign the following certification: "I certify that this report is true, accurate, and complete, to the,fiest o knowledge and belief. " Inspection report completed on: 10/20/20 By: Title/Qualification of Inspector: CESCL Name: Krazan & Associates, Inc. With Offices Serving the Western United States