ENP2021-0003 STREATERY PERMITDescription: FIRE & FEAST STREATERY jApproved: 1/13/2021 12:00:00 AM
(Address: 526 MAIN ST EDMONDS, WA 98020-3148 Parcel: 00434212000900
CONTACTS
NAME TYPE
NAME ADDRESS
PHONE
APPLICANT
SHUBERT HO
2065885148
BUSINESS
FIRE & THE FEAST LLC
2063722446
OWNER
ELSIA LLC 18411 AURORA AVE N
CONDITIONS
CONDITION TYPE
NOTES
Three feet of clearance around fire hydrants, standpipes, PIVs, manholes, water meters, blowoffs,
APPURTENANCE CLEARANCE
cleanouts, valves and other utility appurtenances shall be maintained.
Clear landings of 5 ft, or no less than the width of the door (whichever is greater), measured toward the
CLEAR LANDINGS
street, shall be maintained on the exterior side of all required exit doors.
Safe pedestrian travel area, or clear zone, of 5 ft minimum width, providing a level safe walking surface
CLEAR ZONE TRAVEL AREA
along the public sidewalk, shall be maintained.
Applicant shall repair or replace all damage to utilities or frontage improvements in the City right of way
FRONTAGE IMPROVEMENTS
per City standards that is caused by or occurs during the permitted project.
HEATING EQUIPMENT MUST BE APPROVED BY THE FIRE MARSHAL. FOR MORE INFORMATION SEE CITY
HEATING EQUIPMENT
OF EDMONDS HANDOUT FOR TENTS AND CANOPIES.
THE APPLICANT ON BEHALF OF HIS OR HER SPOUSE HEIRS ASSIGNS AND SUCCESSORS IN INTERESTS
AGREES TO INDEMNIFY DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS WASHINGTON ITS
OFFICIALS EMPLOYEES AND AGENTS FROM ANY AND ALL CLAIMS FOR DAMAGES OF WHATEVER
HOLD HARMLESS
NATURE ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE FOR THIS PERMIT. ISSUANCE OF THIS
PERMIT SHALL NOT BE DEEMED TO MODIFY WAIVE OR REDUCE ANY REQUIREMENTS OF ANY CITY
ORDINANCE NOR LIMIT IN ANY WAY THE CITYS ABILITY TO ENFORCE ANY ORDINANCE PROVISION.
MINIMUM VENTILATION AND SOCIAL SPACING TO BE MAINTAINED IN ACCORDANCE WITH STATE
MINIMUM VENTILATION
REQUIREMENTS.
NO OPEN FLAME
NO OPEN FLAMES OR COOKING ALLOWED WITHIN STRUCTURE.
OCCUPANT LOAD
OCCUPANT LOAD SHALL COMPLY WITH CURRENT STATE REGULATIONS.
PRE -OCCUPANCY
PRE -OCCUPANCY INSPECTION REQUIRED BY ENGINEERING, BUILDING AND FIRE INSPECTORS.
SERVICE OF ALCOHOL
Alcohol service is subject to WSLCCB requirements.
STORM EVENTS
STRUCTURE SHALL NOT BE OCCUPIED DURING HIGH WIND OR HEAVY SNOW EVENTS.
All streatery elements shall be located within the marked parking stalls and none of its elements should
STREATERY BOUNDARIES
extend outside this area --with the exception of structure supports on the sidewalk when approved.
A Streatery shall be permitted for one year and may be considered for extensions of 3 to 6 month
STREATERY EXPIRATION
increments.
Streateries are regulated under ECDC Chapter 18.70 Street Use and Encroachment; and Chapter
STREATERY REGULATION
17.70.040 Bistro and Outdoor Dining. All Streateries will comply with the information and examples
found in the E75C Streatery Handout.
Approved barriers shall be placed at each end of the streatery to enhance safety. Reflective delineators
STREATERY SAFETY
shall be placed at each corner adjacent to the drive lane to improve visibility at night.
Printed: Thursday, January 14, 2021 2:57:59 PM 1 of 3
IN
1xa¢�r
STREATERY
PROJECT NUMBER
City of Edmonds
121 ..•0 1 111
ww . -. •.
M&,w
OL
INSPECTION SCHEDULING: WWW.MYBUILDINGPERMIT.COM OR CALL 425-771-0220
INSPECTION TYPE DATE COMPLETED RESULT NOTES
X-3 BUILDING FINAL
X-2 ENGINEERING FINAL"
E-1 STREATERY
CONSTRUCTION
X-1 FIRE FINAL
The applicant has signed an application which states he/she agrees to hold the City of Edmonds harmless from any injuries, damages or
claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the applicant or the City of Edmonds,
or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs, court
costs, and attorney fees by reason of granting this permit.
Printed: Thursday, January 14, 2021 2:57:59 PM 2 of 3 0010
TRAKiT
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED Streatery to comply with
PLANS MUST BE ; conditions listed on permit ;
ON JOB SITE ------------------------
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
1-13-2021 Eric C * er
Approved by Fire
01/13/2021 AFM fCFCttereY
Inspection approval and occupying:
1.1'abric must be made of fire resistant material and
have tag attached from factory.
2.Open flames are prohibited, including candles,
torches, fire pits, etc.
3.Heating equipment must be approved by Fire
Marshal.
4.AII governor -issued orders and guidelines related
to COVID 19 must be observed.
FIRE & THE FEAST
526 MAIN STREET
OWNER: SHUBERT HO
PHONE: 206.588.5148
DATEL: 1/8/2020
STREATERY SITE PLAN
35'-0"
ENTRANCE FIRE & THE FEAST BUILDING
ADA ACCESSIBLE OU-
0 L00100
5' SIDEWALK MAINTAINED
MAIN
120V. ALL VERANDA SIDES AND ROOF INSTALLED
WITH TUFTEX POLYCARBONATE MATERIAL WITH 270 DEGREE F
RATING.
All elements shall be installed with spacing,
dimensions, and clearances per code
requirements. See Handout E75C Site Plan
Example for compliance information.
12" PIER
)E D�A[ININGA[
VI IV
44
PERMITTED
BISTRO DEMARCATION SEPARATELY
po
,,EXIT: THIS ENTIRE FACE OPEN
2x1FT PLANTER
REFLECTIVE DELINEATOR POST, TYP
11 EXISTING PARKING
EXISTING STRIPING STALL DELINEATOR
FOR EDGE OF STRIPE
DRIVING LANE
VERANDA SOLID SIDES Streatery shall meet all requirements of ECDC Chapters 18.70
and 17.70.040.
>A 5 ft clear pedestrian path shall be maintained at all times.
>Barriers and reflective delineators are required as approved.
>Changes to structure, barriers, or any other streatery
elements shall be submitted to the City for review.
ENGINEERING DIVISION RECEIVED
APPROVED AS NOTED
01/10/2021
01 /12/2021
ENGINEERING DIVISION
r----- - - - - - -
Add blocking
between rafters at '
' outside corners
---------------'
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
CLEAR CORRUGATED PLASTIC @ ROOF & SIDEWALLS
/ FASTENED w/ GASKETED SCREWS @ 8" OC
Add diagonal
brace
'-------------
r----------------------------
Streatery to comply with
conditions listed on permit
-----------------------------
2x6 RAFTER(s) @ 32" OC w/
SIMPSON HURRICANE CLIPS, TYP
1x4 PURLIN(s) LAID FLAT
@ 32" OC LAGGED TO
RAFTERS BELOW, TYP
4x6 BEAMS w/ SIMPSON
APVA BRACKETS or SIM, TYP
4x4 POST(s) @
8'-0" OC MAX, TYP
2x4 HORIZONTAL BRACE w/
SIMPSON FBR CLIPS or SIM, TYP
CONCRETE PIER BLOCK w/
EMBEDDED POST BASE
RECEIVED
JAN 07 2021
CITY OF EDMONDS
DEVELOPMENT
_ SERVICES DEPARTMENT
REVIEWED
BY
CITY OF EDMONDS