Loading...
ENP2021-0011 STREATERY PERMITDescription: SANTA FE STREATERY Approved: 1/21/2021 12:00:00 AM Address: 423 MAIN ST EDMONDS, WA 98020 Parcel: 00434400100101 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT Ricky Bobadilla - Santa Fe General Manager 2536701894 BUSINESS SANTA FE EDMONDS INC 423 MAIN ST 2063272046 OWNER THIRD AVENUE SOUTH PROPERTIES LLC 229 3RD AVE S STE 301 CONDITIONS CONDITION TYPE NOTES Three feet of clearance around fire hydrants, standpipes, PIVs, manholes, water meters, blowoffs, APPURTENANCE CLEARANCE cleanouts, valves and other utility appurtenances shall be maintained. Clear landings of 5 ft, or no less than the width of the door (whichever is greater), measured toward the CLEAR LANDINGS street, shall be maintained on the exterior side of all required exit doors. Safe pedestrian travel area, or clear zone, of 5 ft minimum width, providing a level safe walking surface CLEAR ZONE TRAVEL AREA along the public sidewalk, shall be maintained. Applicant shall repair or replace all damage to utilities or frontage improvements in the City right of way FRONTAGE IMPROVEMENTS per City standards that is caused by or occurs during the permitted project. HEATING EQUIPMENT MUST BE APPROVED BY THE FIRE MARSHAL. FOR MORE INFORMATION SEE CITY HEATING EQUIPMENT OF EDMONDS HANDOUT FOR TENTS AND CANOPIES. THE APPLICANT ON BEHALF OF HIS OR HER SPOUSE HEIRS ASSIGNS AND SUCCESSORS IN INTERESTS AGREES TO INDEMNIFY DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS WASHINGTON ITS OFFICIALS EMPLOYEES AND AGENTS FROM ANY AND ALL CLAIMS FOR DAMAGES OF WHATEVER HOLD HARMLESS NATURE ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE FOR THIS PERMIT. ISSUANCE OF THIS PERMIT SHALL NOT BE DEEMED TO MODIFY WAIVE OR REDUCE ANY REQUIREMENTS OF ANY CITY ORDINANCE NOR LIMIT IN ANY WAY THE CITYS ABILITY TO ENFORCE ANY ORDINANCE PROVISION. MINIMUM VENTILATION AND SOCIAL SPACING TO BE MAINTAINED IN ACCORDANCE WITH STATE MINIMUM VENTILATION REQUIREMENTS. NO OPEN FLAME NO OPEN FLAMES OR COOKING ALLOWED WITHIN STRUCTURE. OCCUPANT LOAD OCCUPANT LOAD SHALL COMPLY WITH CURRENT STATE REGULATIONS. PRE -OCCUPANCY PRE -OCCUPANCY INSPECTION REQUIRED BY ENGINEERING, BUILDING AND FIRE INSPECTORS. SERVICE OF ALCOHOL Alcohol service is subject to WSLCCB requirements. STORM EVENTS STRUCTURE SHALL NOT BE OCCUPIED DURING HIGH WIND OR HEAVY SNOW EVENTS. All streatery elements shall be located within the marked parking stalls and none of its elements should STREATERY BOUNDARIES extend outside this area --with the exception of structure supports on the sidewalk when approved. A Streatery shall be permitted for one year and may be considered for extensions of 3 to 6 month STREATERY EXPIRATION increments. Streateries are regulated under ECDC Chapter 18.70 Street Use and Encroachment; and Chapter STREATERY REGULATION 17.70.040 Bistro and Outdoor Dining. All Streateries will comply with the information and examples found in the E75C Streatery Handout. Approved barriers shall be placed at each end of the streatery to enhance safety. Reflective delineators STREATERY SAFETY shall be placed at each corner adjacent to the drive lane to improve visibility at night. Printed: Thursday, January 21, 20214:43:10 PM 1 of 3 IN 1xa¢�r STREATERY PROJECT NUMBER City of Edmonds - ••01 0011 ww cityofedmonds.gov INSPECTION SCHEDULING: WWW.MYBUILDINGPERMIT.COM OR CALL 425-771-0220 1 INSPECTIONS INSPECTION TYPE DATE COMPLETED RESULT NOTES E-1 STREATERY CONSTRUCTION X-1 FIRE FINAL X-2 ENGINEERING FINAL" X-3 BUILDING FINAL The applicant has signed an application which states he/she agrees to hold the City of Edmonds harmless from any injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the applicant or the City of Edmonds, or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs, court costs, and attorney fees by reason of granting this permit. Printed: Thursday, January 21, 20214:43:10 PM 2 of 3 0010 TRAKiT Santa Fe Mexican Grill 423 Main Street Owner: Hector Olguin Phone: 206-327-2046 Date: January 20th, 2021 9,9„ Parking Sig\ 1 FT- 1 FT / Approved By Fire DFM17 PBrough 01/21/21 All elements shall be installed with spacing, dimensions, and clearances per code requirements. See Handout E75C Site Plan Example for compliance information. Streatery shall meet all requirements of ECDC Chapters 18.70 and 17.70.040. A 5 ft clear pedestrian path shall be maintained at all times. >Barriers and reflective delineators are required as approved. >Changes to structure, barriers, or any other streatery elements shall be submitted to the City for review. ENGINEERING DIVISION APPROVED AS NOTED 01/21/2021 EN P2021-0011 Sidewalk Dining requires a separate permit. Structure supports shall not encroach /further than 2' on to sidewalk measured from face of curb. spection approval and occupying: side Door 1. bric must be made of fire resistant material and 3'i5ft have attachecUrpm factory or approval from Building S' alk Pre Markin s 2.Open lames are, ohlbited, including candles, torche ,Fire pits, etc. 5ft ea i g equipment m st be approved by Fire 31 1' C 19 must be observed. 6'18" Stre tery Area 8' 32' 6'18" $„ 1 FT Existing Striping for edge of parking stall 14' 36' 16' Existing Parking stall delineator stripe 17' 20' Existing Striping for 1 edge of parking stall Ox-M 'lanters shall be )laced at pier )locks to reduce :rip hazard. tme as other side RESUB Jan 20 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT r------ - - - - - - Add blocking between rafters at ' ' outside corners --------------- Approved by Fire 01/14/2021 AFM l'_Fi rer Inspection approval and occupying: 1.Fabric must be made of fire resistant material and have tag attached from factory or approval from Building and Fire Prevention. 2.0pen flames are prohibited, including candles, torches, fire pits, etc. 3.Heating equipment must be approved by Fire Marshal. 4.AII governor -issued orders and guidelines related to COVID 19 must be observed. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE CLEAR CORRUGATED PLASTIC @ ROOF & SIDEWALLS / FASTENED w/ GASKETED SCREWS @ 8" OC Add diagonal brace '------------- r---------------------------- Streatery to comply with conditions listed on permit ----------------------------- 2x6 RAFTER(s) @ 32" OC w/ SIMPSON HURRICANE CLIPS, TYP 1x4 PURLIN(s) LAID FLAT @ 32" OC LAGGED TO RAFTERS BELOW, TYP 4x6 BEAMS w/ SIMPSON APVA BRACKETS or SIM, TYP 4x4 POST(s) @ 8'-0" OC MAX, TYP 2x4 HORIZONTAL BRACE w/ SIMPSON FBR CLIPS or SIM, TYP CONCRETE PIER BLOCK w/ EMBEDDED POST BASE Reflective Tape to be applied along sides at 38" height for traffic safety. RECEIVED JAN 07 2021 CITY OF EDMONDS DEVELOPMENT _ SERVICES DEPARTMENT REVIEWED BY CITY OF EDMONDS