ENP2021-0012 STREATERY PERMITDescription: DAPHNES CAFE STREATERY Approved: 1/21/2021 12:00:00 AM
Address: 415 MAIN ST EDMONDS, WA 98020-3137 Parcel: 00434400100102
CONTACTS
NAME TYPE
NAME ADDRESS
PHONE
APPLICANT
Brian Taylor
7189387711
BUSINESS
DAPHNES CAFE INC. 415 MAIN ST
7189387711
OWNER
THIRD AVENUE SOUTH PROPERTIES LLC 2080 3RD ST UNIT 3
CONDITIONS
CONDITION TYPE
NOTES
Three feet of clearance around fire hydrants, standpipes, PIVs, manholes, water meters, blowoffs,
APPURTENANCE CLEARANCE
cleanouts, valves and other utility appurtenances shall be maintained.
Clear landings of 5 ft, or no less than the width of the door (whichever is greater), measured toward the
CLEAR LANDINGS
street, shall be maintained on the exterior side of all required exit doors.
Safe pedestrian travel area, or clear zone, of 5 ft minimum width, providing a level safe walking surface
CLEAR ZONE TRAVEL AREA
along the public sidewalk, shall be maintained.
Applicant shall repair or replace all damage to utilities or frontage improvements in the City right of way
FRONTAGE IMPROVEMENTS
per City standards that is caused by or occurs during the permitted project.
HEATING EQUIPMENT MUST BE APPROVED BY THE FIRE MARSHAL. FOR MORE INFORMATION SEE CITY
HEATING EQUIPMENT
OF EDMONDS HANDOUT FOR TENTS AND CANOPIES.
THE APPLICANT ON BEHALF OF HIS OR HER SPOUSE HEIRS ASSIGNS AND SUCCESSORS IN INTERESTS
AGREES TO INDEMNIFY DEFEND AND HOLD HARMLESS THE CITY OF EDMONDS WASHINGTON ITS
OFFICIALS EMPLOYEES AND AGENTS FROM ANY AND ALL CLAIMS FOR DAMAGES OF WHATEVER
HOLD HARMLESS
NATURE ARISING DIRECTLY OR INDIRECTLY FROM THE ISSUANCE FOR THIS PERMIT. ISSUANCE OF THIS
PERMIT SHALL NOT BE DEEMED TO MODIFY WAIVE OR REDUCE ANY REQUIREMENTS OF ANY CITY
ORDINANCE NOR LIMIT IN ANY WAY THE CITYS ABILITY TO ENFORCE ANY ORDINANCE PROVISION.
MINIMUM VENTILATION AND SOCIAL SPACING TO BE MAINTAINED IN ACCORDANCE WITH STATE
MINIMUM VENTILATION
REQUIREMENTS.
NO OPEN FLAME
NO OPEN FLAMES OR COOKING ALLOWED WITHIN STRUCTURE.
OCCUPANT LOAD
OCCUPANT LOAD SHALL COMPLY WITH CURRENT STATE REGULATIONS.
PRE -OCCUPANCY
PRE -OCCUPANCY INSPECTION REQUIRED BY ENGINEERING, BUILDING AND FIRE INSPECTORS.
SERVICE OF ALCOHOL
Alcohol service is subject to WSLCCB requirements.
STORM EVENTS
STRUCTURE SHALL NOT BE OCCUPIED DURING HIGH WIND OR HEAVY SNOW EVENTS.
All streatery elements shall be located within the marked parking stalls and none of its elements should
STREATERY BOUNDARIES
extend outside this area --with the exception of structure supports on the sidewalk when approved.
A Streatery shall be permitted for one year and may be considered for extensions of 3 to 6 month
STREATERY EXPIRATION
increments.
Streateries are regulated under ECDC Chapter 18.70 Street Use and Encroachment; and Chapter
STREATERY REGULATION
17.70.040 Bistro and Outdoor Dining. All Streateries will comply with the information and examples
found in the E75C Streatery Handout.
Approved barriers shall be placed at each end of the streatery to enhance safety. Reflective delineators
STREATERY SAFETY
shall be placed at each corner adjacent to the drive lane to improve visibility at night.
Printed: Thursday, January 21, 2021 10:19:10 AM 1 of 3
IN
1xa¢�r
STREATERY
PROJECT NUMBER
City of Edmonds
- ••01 11
ww cityofedmonds.gov
INSPECTION SCHEDULING: WWW.MYBUILDINGPERMIT.COM OR CALL 425-771-0220
1 INSPECTIONS
INSPECTION TYPE DATE COMPLETED RESULT NOTES
E-1 STREATERY
CONSTRUCTION
X-1 FIRE FINAL
X-2 ENGINEERING FINAL"
X-3 BUILDING FINAL
The applicant has signed an application which states he/she agrees to hold the City of Edmonds harmless from any injuries, damages or
claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the applicant or the City of Edmonds,
or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs, court
costs, and attorney fees by reason of granting this permit.
Printed: Thursday, January 21, 2021 10:19:10 AM 2 of 3 0010
TRAKiT
I1f�84b%It •��,(d1 d /`'af1� •1�a�'15 Nrvw 5l�' S�NN4�'4 I �3Z
r S � rljvd
ISNV WAA Aldwoo
o} sluouodwoo
algissaooV VaV
�o
IL IL 111
trt/
O O1
jpjad ayj uo palsll CITY OF EDMONDS
suol}ipuoo gjim Ajdwo§K*R UILDING DIVISION
T z0 z-0 - 1I OVED PLAN
CITY 01 EDMONDS
DEVELOPM NT SERVICES
DEP TMENT
1 • 111
�,-Tvv
5-501 Aso
„Six „ ,
11.E
-4-11
101
✓ �i
►, �� vas �'��-►rod �-
All e®fL�yll@f�IIIN?ilYr
dim%Wcjrys7E)r@Aglearances per cod
Exaa rfersconoi0foz�tiwmfduMallob
>Changes to structure, barriers, c
elements shall be submitted to th
ENGINEERING DIVISION
APPROVED AS NOTED
01/19/20:
vl
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
l t-6 84b 8/t • �1377hV-L
Id �411vw 9-t * 5=jtjo&v(T
fil-009
'. 1 C7
L
C� O
Di7
d
w-)9Pvld 4-vvil d,-vo") eat
S :�l N 14d`>Q
r'V7� ,,�1Y3�l15
r----- - - - - - -
Add blocking
between rafters at '
' outside corners
---------------
Approved by Fire
Inspection approval and occupying'.
1. Fabric must be made of fire resistant material
and have tag agach.d from factory or approval
from Building and Fire Prevention.
2.0pen Flames are prohibited, including camdles,
torches, fire pits, etc.
3. Heating equipment must be approved by Flrc
Marshal
4 All governo..es— orders and guidelines
related to COVIO 19 must be observed.
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
CLEAR CORRUGATED PLASTIC @ ROOF & SIDEWALLS
/ FASTENED w/ GASKETED SCREWS @ 8" OC
Add diagonal
brace
'-------------
r----------------------------
Streatery to comply with
conditions listed on permit
-----------------------------
2x6 RAFTER(s) @ 32" OC w/
SIMPSON HURRICANE CLIPS, TYP
1x4 PURLIN(s) LAID FLAT
@ 32" OC LAGGED TO
RAFTERS BELOW, TYP
4x6 BEAMS w/ SIMPSON
APVA BRACKETS or SIM, TYP
4x4 POST(s) @
8'-0" OC MAX, TYP
2x4 HORIZONTAL BRACE w/
SIMPSON FBR CLIPS or SIM, TYP
CONCRETE PIER BLOCK w/
EMBEDDED POST BASE
RECEIVED
JAN 07 2021
CITY OF EDMONDS
DEVELOPMENT
_ r SERVICES DEPARTMENT
REVIEWED
BY
CITY OF EDMONDS