Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-1558_Applicant_Response_11.16.2021_10.46.50_AM_2522507
r Product Data PREMIUM ENVIRONMENTALLY RESPONSIBLE FAN COIL The latest in technology makes the FE4A and FESA fan coil models the most advanced air handlers available. With attention to quiet, efficient, and comfortable operation, Carrier has developed a new benchmark for homeowner comfort and ease of installation. The FE4A and FESA utilize the Infinity@ Control as a required accessory to enable state of the art smart —diagnostics capability. This enables faster troubleshooting, providing ease of service and repair. The FE4A and FESA also provide a 4—wire hook up with matching outdoor unit and the Infinity'D Control. This makes installation simpler and a lot quicker than with conventional fan coils. The FE4A and FESA have advanced technology that allows the fan coil to self —configure with a matching outdoor unit and the Infinity's Control, cutting down on installation time. The FE4A and FESA feature Puron@ refrigerant, the chlorine —free alternate that is the future for the residential heating and cooling industry. The FE4A and FESA using Puron® refrigerant maximize performance for environmentally responsible systems. In addition to environmental safety, these systems are 30 to 40% more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental sustainability. The FE4A and FESA provide these benefits due to Carrier's command of Electronically Commutating Motor (ECM) technology. These motors are extremely efficient at all speeds, and enable the FE4A and FESA to operate at the correct speed to deliver airflow precisely, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also makes installation quality easier to achieve for today's demanding homeowner. Carrier's command of ECM technology may be most evident in the comfort advantages that an ECM can deliver. For true comfort, the homeowner can achieve command of both temperature and humidity in cooling and heating modes. Another feature which sets the FE4A and FESA apart is the factory —installed TXV, which enhances efficiency and provides compressor —protecting operation at all recommended conditions. Grooved tubing, louvered aluminum fins, and the large face areas of the FE4A and FESA refrigerant coils also provide superior efficiency, for high SEER and HSPF performance. Carrier leads the way in condensate control, a hallmark of these multipoise fan coils. All of these featured components are protected within a rugged, pre —painted metal cabinet lined with super —thick, high —density insulation. For neat, high quality installations, the unit exterior features sweat refrigerant connections for simple leak free performance, and multiple electrical entry for both high and low voltage service. Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard. FEATURES Smart Diagnostics • Self configuring (ease of installation) • Easier troubleshooting, providing faster service and repair • Energy Tracking capability with the Infinity@ Series Wall Control. (Energy Tracking has the ability to monitor and estimate the energy consumption of your InfinityO system.) Environmentally Responsible Refrigerant Technology • Puron® refrigerant the chlorine —free, non —ozone depleting refrigerant • Thermostatic Expansion Valve (TXV) designed to maximize performance with Puron® refrigerant Energy Efficient Operation • Electronically Commutated Motor (ECM) operates efficiently at all speeds • Maximizes efficiency of heating and cooling systems • Ultra —low power consumption during fan only operation Comfort Control • Warm, comfortable heating air temperatures • Unmatched humidity control Airflow and Sound Technology • Logarithmic spiral blower housings for high blower efficiency and quiet operation • Diffuser air discharge section for high airflow efficiency and quiet, smooth operation • High duct static capability • Design meets stringent regulations for cabinet air leakage of less than 2% when tested at 0.5 inches W.C., and cabinet air leakage less than 1.4% at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard. Condensate Control and Disposal Technology • Minimal standing water — less microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage • Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance • Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions • Tested for condensate disposal at conditions much more severe than those required by ARI • Primary and secondary drain connections to comply with HUD • All pans constructed of an injection molded glass —filled polycarbonate engineered resin material, with brass drain connections • High density, super thick cabinetry insulation with vapor barrier • Pre —painted galvanized sheet metal cabinet Heat Transfer Technology • Grooved tubing • Lanced sine wave aluminum fins • Discreet refined counterflow refrigerant circuitry • Bi—flow hard —shutoff TXV metering device Quality Assisting, Ease of Installation and Service Features • Easy 4 wire hook up: convenient and reduces installation time. • FE4A unit is multipoise • FE5A unit is upflow/downflow only (single drain pan). • Provision made for suspending from roof or ceiling joints • Modular cabinet on sizes 003 through 006 • Sweat connections for leak free service • Multiple electrical entry for application flexibility (high and low voltage) • Low voltage terminal strip, to safely hold connections within the cabinet • Cabinet construction features innovations designed to prevent cabinet sweating Controls and Electrical Features • Easy plug connection provided for quick installation of accessory heater packages • 40VA 208/230v transformer • Replaceable 3—amp blade —type auto fuse protects against transformer secondary short Filter Features • Factory supplied filter • Cleanable polyester filter media • Filter "springs" out for easy access — no tools required • Newly improved filter rack area — filter door insulation added for an improved air seal MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F E 4 A N B 0 0 2 0 0 0 Product F = Fan Coil Type E = Infinityl, VS, Puron@ Refrigerant Position 4 = Multi —poise 5 = Upflow / Downflow Series A Electrical N = 208/230v, 1 ph-60 Hz "'� ArmorTech Coil Type T00 = Tin—plated 000 = Copper L00 = Aluminum Capacity 002 = 18-36,000 003 = 24-42,000 004 = 24-42,000 005 = 30-48,000 006 = 36-60,000 Cabinet / Insulation B = Modular F = Single piece Use of the AHRI Certitied TM Mark indicates a nufact participationion in in the y q program For verification of certification for individual , products, go to .—ahridirectory.org. ISO 9001 GMI-SAI Global 3 Am ON VILW 15/16'� B NOTE: I. SERIES DESIGNATION IS THE I4TH POSITION OF UNIT PRODUCT NUMBER DISCONNECT OA C IACUIT BAEANEA LOCATION UNIT CONNECTION SIZES LOWE A, CONTROL, d EL EC iA IC HEATER SUCTION: 002 d 003 - 3//" I. D. SWEAT ACCESS PANEL ppN . 00R - 7/8" I. D. SWEAT LIQUID: 3/8' I.D. SWEAT CONDENSATE: 3/4" FPT OANEL IL ACCESS P 2 5/8' d II/I6' ING IQUID LINE CONN ECiION LIQUID LINE ,4A 3/I6' CONNECTION UCTION LINE CONNECTION10 T/I6' SUCTION LINE 10 3/4" CONNECTION 9 I/2'. 6 O I 1 2 I/8" NOTE: ALLOW 21" FROM FRONT FOR SEA, ICE 1 3/I6" — 1 3/d'- 2 1/16. 10 3/16' 7/8' 1. � 3/4' OUT LET AIA '—ALTERNATE T/8",I 3/32',2'DIA. N.O.'S NOTE: MODULAR FOR HIGH VOLTAGE UNITS WLL HAVE POWER WIRING OPPOSITE SIDE A TWO - PIECE CABINET — OPTIONAL FIELD CONVEA TIED RIGHT SIDE RETURN OPENING ISLOPE COIL UNITS ONLY) � I I/2" Ax H FOR MODULAR UNITS 8" FILTER ACCESS OPENING 1• OPENING D PANEL SLOPE COIL DETAILS CONNECTION LOCATIONS SNOWN FOR OR BONS ACCESS PANEL CONFI6 FOR SLOPE COILS DOWNFLOW OR HOR11. AIGHi APPLICATIONS 11/4" 1913/I6" RIGHT SIDE VIEW L 21n° SHOWN WITH LOCATIONS INLET AIA FRONT VIEW 'A' COIL DETAILS CONNECTION FOR UPFLOW ORNOAI,. APPLICATIONS LEFT APPLICATIONS T APPLICATIONS AND "A" COILS DOWNFLOW APPLICATIONS INLET AIR DIMENSIONS A B C D E H* UNIT SIZE in mm in mm in m m in . m m in mm in mm FE4A 002 42-11/16 1084 17-5/8 448 15-3/4 400 15-5/8 397 10-3/4 273 FE4A 003 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-3/16 487 FE4A 003* 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-3/16 487 28-5/16 719 FE4A 005 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-1/2 495 FE4A 005* 53-7/16 1357 21-1/8 537 19-1/4 489 19-1/8 486 19-1/2 495 28-5/16 719 FE4A 006* 59-3/16 1503 24-11/16 627 22-3/4 578 22-11/16 576 25-1/4 641 34-1/16 865 FE5A 004* 59-3/16 1503 24-11/16 627 22-3/4 578 22-11/16 576 25-1/4 641 34-1/16 865 * Modular Cabinet NOTES: I. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. SLOPE COI 6" TYP. AIRFLOW (2 PLACES)• AIRFLOW 2 3116" iYP. f I 12 PLACES)- L1' TYR. PRIMARY DAAI 12 PL ACES(• 3/4" SECONDARY DRAIN F G PRIMARY DAAI I I/d" SECONDARY DRAIN 13/I6' TYP.- 5/I6' TIP SECONDARY DRAIN ® PA I MARY DRAIN ` © ® 1TYP6.1 1 1/2" /d' � I' iYP. T Id/PLLACES)� TYP.- 5/8" 2 9/16" 12 PLACES I+ 7l8 2 T/8• 2 3TY P! 3 I/4" ITYP6•� P.' HORIZ. LEFT a PLace51' UPFLOW DOWNFLOW (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) /I6" TYP. • HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, (d PLACES) AND DACN OF CABINET IN CABINET RDWAR E. HOLES FPROIELD IDED AIRFLOW AIRFLOW 2 3PLAC TYP . 136' DI A. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. } 12 PLACES), I+ — — ,• TYP T © 12 PLACES) © Q 15/8" ® I/2" TYP.+ Tl8" F P.+ HORIZ. RIGHT (FIELD CONVERTED) SECONDARY DRAIN F d 3/d' O O G I PANAAY DR AI 3 I/16" O �:JSECONDARY DRAIN AIMAAY DRAIN PRIMARY DRAIN 13/1S16 I ' SECONDARY DRAIN iYPx r r TYP . SECONDARY DRAIN 1 O O 0 PRIMARY DRAIN O r ®• O O O O 3' I'D © 12 IL YAM). I+ ® © L IT1i I/2- T /2 I/2' S/16" 3 1/I6" T/I6" TYP, �-F �118 3/I6" TYP+ 5 7/e' 2 II/16' _{ yllll TYP+ d 3l d" fd PLAC ES I• TYP.+ i/g13/16' 2 3/I6' 113116 rrP+ TTra•' (2 PLACES)- DOWNFLOW TYP. HORIZ. RIGHT TVPe• HORIZ. LEFT UPFLOW (FIELD CONVERTED) (FIELD CONVERTED) (AS SHIPPED) (AS SHIPPED) A DIMENSIONS UNIT SIZE F G COIL CONFIGURATION SHIPPING WEIGHT in mm in mm Slope A' lb / kg FE4A 002 18-9/16 472 18-1/4 464 Yes 135 / 61 FE4A 003 26-15/16 684 27-1/2 699 Yes — 150 / 68 FE4A 003* 26-15/16 684 27-1/2 699 Yes — 150 / 68 FE4A 005 27-1/4 692 26-15/16 684 — Yes 172 / 78 FE4A 005* 27-1/4 692 26-15/16 684 — Yes 172 / 78 FE4A 006* 32-15/16 837 32-5/8 829 — Yes 207 / 94 FE5A 004* 32-15/16 837 32-5/8 829 — Yes 200 / 91 * Modular Cabinet PHYSICAL DATA NOMINAL DIMENSIONS ORDERING NO. FIELD -INSTALLED HEAT COOLING CA - (kW) PACITY (BTUH) Height Width Depth FE4ANF002000 18,000 42-11/16-in10 17-5/8-in 448 22-1/16-in FE4ANF002T00 5, 8, 9, 10, 15, 20 to 84 mm mm 560 mm FE4ANF002L00 36,000 FE4ANF003000 24,000 53-7/16-in 21-1/8-in537 22-1/16-in FE4AN(B,F)003T00 5, 8, 9, 10, 15, 18, 20 to 1357 mm mm 560 mm FE4AN (B, F)003L00 42,000 FE4ANF005000 30,000 53-7/16-in 21-1/8-in537 22-1/16-in FE4AN(B,F)005T00 5, 8, 9, 10, 15, 18, 20, 24, 30 to 1357 mm mm 560 mm FE4AN (B, F)005L00 48,000 FE4ANB006000 36,000 59-3/16-in 24-11/16-in 22-1/16-in FE4ANB006T00 8, 9, 10, 15, 18, 20, 24, 30 to 1503 mm 627 mm 560 mm FE4ANB006L00 60,000 FE5ANB004T00 24,000 59-3/16-in 24-11/16-in 22-1/16-in FE5ANB004L00 5, 8, 9, 10, 15, 18, 20 to 1503 mm 627 mm 560 mm 42,000 COIL Refrigerant Metering Device TXV Size 2 Ton Configuration A Rows-Fins/In. Face Area (Sq Ft) 3.46 MATCHES OUTDOOR UNIT SIZES Nominal Cooling Tons 1.5, 2, 2.5, 3 FAN Air Discharge CFM/Ton (Nominal Clg/Htg) Motor HP (ECM) 1/2 Filter 16-3/8-in 21-1/2-in (546 mm) x (417 mm) CABINET CONFIGURATION OPTIONS 1-piece SPECIFICATIONS PuronSO Refrigerant (R-410A) TXV 3 Ton 4 Ton 5 Ton Slope A A 3/14.5 3.46 5.93 7.42 SHIPPING WEIGHT lb / kg 135 lb 61 kg 150 lb 68 kg 172 lb 78 kg 207 lb 94 kg 200 lb 91 kg 3 Ton A 7.42 2,2.5,3,3.5 2.5,3,3.5,4 3,3.5,4,5 2,2.5,3,3.5 Upflow, Downflow, Horizontal Upflow, Downflow 350+ 1/2 1/2 3/4 3/4 19-7/8-in 19-7/8-in 23-5/16-in 23-5/16-in (505 mm) (505 mm) (592 mm) (592 mm) 1-piece / Modular 1-piece / Modular Modular Modular 6 PERFORMANCE DATA AIRFLOW DELIVERY - COOLING, HEATING, ELECTRIC HEATING MODES The FE4 and FE5A fan coils will provide airflow at a rate that is documentation for the User Interface for more information on how requested by the Integrated System User Interface during air the User Interface controls the fan coil. Safe operation of electric conditioning or heat pump heating (without electric heat) modes. heaters requires airflow delivery at or above the minimum CFM for The nominal airflow for both heating and cooling modes is 350 electric heater application listed in the chart below. The fan coil cfm/ton nominal size of the outdoor unit installed. The airflow will adjust its airflow delivery to maintain safe airflow as operating actually requested by the User Interface is modified by its internal mode and staging conditions require. algorithms for zoning, comfort or efficiency concerns. Refer to the FE4A/FE5A FAN COIL AIRFLOW DELIVERY CHART (CFM) - ELECTRIC HEATING MODELS ELECTRIC HEATER kW RANGE MODEL FE4A OUTDOOR UNIT CAPACITY BTUH 5 9 10 15 20 24 30 EMERGENCY 625 625 675 775 950 18,000 625 625 675 002 24,000 650 725 775 900 30,000 800 875 875 925 1125 36,000 975 975 975 1025 1125 EMERGENCY 675 700 775 850 1050 24,000 675 875 875 1100 1150 003 30,000 800 875 875 1100 1150 36,000 975 975 1025 1150 1250 42,000 1125 1125 1125 1150 1350 EMERGENCY 675 700 775 850 1050 1400 1425 30,000 800 875 875 1100 1150 005 36,000 975 975 1025 1150 1250 42,000 1125 1125 1125 1150 1250 48,000 1305 1305 1305 1305 1350 1500 1600 EMERGENCY 1050 1050 1050 1050 1125 1750 1750 36,000 1050 1050 1100 1350 1350 006 42,000 1125 1125 1150 1350 1350 48,000 1300 1300 1300 1350 1500 1750 1750 60,000 1625 1625 1625 1625 1750 1750 1750 ELECTRIC HEATER kW RANGE MODEL FE5A OUTDOOR UNIT CAPACITY BTUH 5 9 10 15 20 24 30 EMERGENCY 675 775 775 900 1125 24,000 975 975 975 004 30,000 1050 1050 1100 1125 36,000 1050 1050 1100 1350 1350 42,000 1125 1125 1150 1350 1350 Note 1: Emergency — Air conditioner with electric heater application, or emergency heat. Note 2: These airflows are minimum airflows as UL listed. Note 3: Dashed entry indicates that the heater/fan coil/outdoor unit combination is not approved. Do not apply. 7 ACCEPTABLE DUCT CONDITIONS 0.7 0.6 0.5 3 0.4 W 7 0) N W 0 a 0.3 U Q J (L 0.2 U) 0.1 ACCEPTABLE RANGE TOO HIGH RETURN STATIC -------------r-------------r------------------------- ---- PRESSURE ---- (DIFFICULT TO MAKE TRAP) n ni nq ns nA ns n RETURN STATIC PRESSURE (in we) A07273 For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed with duct systems which fall within the "Acceptable Range" illustrated above. MINIMUM RPM TABLE MAXIMUM STATIC TABLE MODEL SYSTEM SIZES CFM MIN MODEL AIRFLOW AVAILABLE STATIC RANGE RPM DELIVERY PRESSURE FE4ANF002 018, 024, 030, 036 150 — 1200 300 525 CFM 1.00 in we FE4AN(B,F)003 024, 030, 036, 042 200 — 1400 285 700 CFM 1.00 in we FE4AN(B,F)005 030, 036, 042, 048 250 — 1600 275 FE4ANF002 875 CFM 1.00 in we FE4ANB006 036, 042, 048, 060 500 — 2000 275 1050 CFM 0.80 in we FE5ANB004 024, 030, 036, 042 500 — 1400 275 1200 CFM 0.60 in we 700 CFM 1.00 in we 875 CFM 1.00 in we FE4AN(B,F)003 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 0.80 in we 875 CFM 1.00 in we 1050 CFM 1.00 in we FE4AN(B,F)005 1225 CFM 1.00 in we 1400 CFM 1.00 in we 1600 CFM 0.50 in we 1050 CFM 1.00 in we 1225 CFM 1.00 in we FE4ANB006 1400 CFM 1.00 in we 1750 CFM 1.00 in we 2000 CFM 0.60 in we 700 CFM 1.00 in we 875 CFM 1.00 in we FE5AN13004 1050 CFM 1.00 in we 1225 CFM 1.00 in we 1400 CFM 1.00 in we 8 GROSS COOLING CAPACITIES (MBTUH) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (°F / °C) AIR 35/2 40/4 45/7 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 40.19 19.65 0.00 36.23 17.59 0.00 31.86 15.48 0.00 27.00 13.31 0.00 21.65 11.11 0.00 500 67/19 32.99 19.92 0.01 28.96 17.79 0.01 24.52 15.62 0.01 19.64 13.40 0.01 14.28 11.17 0.01 62/17 26.44 20.11 0.01 22.36 17.93 0.01 17.93 15.73 0.01 13.56 13.56 0.03 11.28 11.28 0.19 72/22 49.76 24.23 0.00 44.85 21.76 0.00 39.40 19.20 0.00 33.36 16.55 0.01 26.66 13.83 0.01 650 67/19 40.90 24.80 0.01 35.90 22.22 0.01 30.37 19.55 0.02 24.27 16.82 0.02 17.58 14.06 0.02 62/17 32.84 25.24 0.02 27.75 22.56 0.02 22.25 19.85 0.02 17.13 17.13 0.06 14.25 14.25 0.21 72/22 61.99 30.08 0.00 55.87 27.15 0.00 49.04 24.04 0.01 41.48 20.80 0.02 33.10 17.46 0.02 875 67/19 51.08 31.23 0.03 44.83 28.09 0.03 37.91 24.84 0.03 30.23 21.47 0.03 21.83 18.03 0.03 62/17 41.11 32.14 0.03 34.76 28.88 0.03 27.91 25.53 0.04 22.04 22.04 0.10 18.33 18.33 0.25 72/22 67.83 32.91 0.00 61.10 29.76 0.00 53.66 26.40 0.02 45.36 22.89 0.03 36.17 19.27 0.03 1000 67/19 55.96 34.39 0.04 49.12 31.01 0.04 41.53 27.48 0.04 33.11 23.83 0.04 23.88 20.06 0.04 62/17 45.09 35.62 0.04 38.13 32.08 0.04 30.69 28.43 0.05 24.54 24.54 0.12 20.40 20.40 0.27 72/22 77.77 37.84 0.00 70.13 34.30 0.03 61.59 30.55 0.05 52.04 26.60 0.05 41.42 22.50 0.05 1250 67/19 64.36 40.02 0.06 56.52 36.24 0.06 47.77 32.27 0.06 38.04 28.12 0.06 27.46 23.81 0.07 62/17 51.98 41.92 0.06 44.00 37.93 0.06 35.61 33.77 0.08 29.12 29.12 0.16 24.20 24.20 0.30 72/22 43.01 20.98 0.00 38.69 18.78 0.00 33.92 16.51 0.00 28.64 14.18 0.00 22.85 11.81 0.01 600 67/19 35.27 21.34 0.01 30.88 19.04 0.01 26.07 16.71 0.01 20.79 14.34 0.01 15.03 11.95 0.01 62/17 28.24 21.59 0.01 23.81 19.25 0.01 19.05 16.90 0.02 14.56 14.56 0.05 12.11 12.11 0.21 72/22 53.83 26.15 0.00 48.40 23.49 0.00 42.36 20.71 0.00 35.72 17.83 0.02 28.38 14.89 0.02 800 67/19 44.23 26.92 0.02 38.71 24.10 0.02 32.61 21.20 0.03 25.91 18.24 0.03 18.65 15.26 0.03 62/17 35.47 27.49 0.03 29.87 24.58 0.03 23.89 21.65 0.03 18.67 18.67 0.09 15.51 15.51 0.24 72/22 63.07 30.60 0.00 56.66 27.57 0.00 49.58 24.36 0.02 41.76 21.04 0.03 33.10 17.62 0.03 1000 67/19 51.91 31.82 0.04 45.41 28.58 0.04 38.24 25.24 0.04 30.31 21.78 0.04 21.76 18.29 0.05 62/17 41.71 32.80 0.04 35.12 29.43 0.04 28.13 26.00 0.05 22.41 22.41 0.12 18.60 18.60 0.27 72/22 71.01 34.48 0.00 63.77 31.12 0.02 55.79 27.57 0.04 46.95 23.88 0.05 37.18 20.08 0.05 1200 67/19 58.54 36.17 0.05 51.21 32.59 0.05 43.10 28.87 0.06 34.13 25.02 0.06 24.47 21.08 0.06 62/17 47.12 37.60 0.06 39.70 33.86 0.06 31.89 30.00 0.07 25.83 25.83 0.15 21.43 21.43 0.29 72/22 77.95 37.95 0.01 70.07 34.31 0.04 61.29 30.47 0.06 51.54 26.47 0.06 40.78 22.33 0.07 1400 67/19 64.44 40.15 0.07 56.37 36.28 0.07 47.43 32.24 0.07 37.54 28.04 0.07 26.89 23.69 0.08 62/17 51.95 42.08 0.07 43.78 37.99 0.08 35.30 33.73 0.09 28.95 28.95 0.19 24.01 24.01 0.32 72/22 40.42 19.84 0.00 36.59 17.80 0.00 32.35 15.70 0.00 27.64 13.54 0.00 22.39 11.33 0.00 600 67/19 33.22 20.00 0.00 29.31 17.90 0.00 24.99 15.74 0.00 20.19 13.53 0.00 14.87 11.27 0.00 62/17 26.67 20.11 0.00 22.69 17.95 0.00 18.31 15.75 0.00 13.60 13.54 0.00 11.29 11.29 0.17 72/22 52.07 25.46 0.00 47.19 22.92 0.00 41.75 20.28 0.00 35.66 17.53 0.00 28.84 14.70 0.00 800 67/19 42.88 25.89 0.00 37.88 23.24 0.00 32.31 20.49 0.00 26.10 17.66 0.00 19.18 14.75 0.00 62/17 34.51 26.21 0.00 29.39 23.46 0.00 23.73 20.64 0.00 17.81 17.81 0.01 14.85 14.85 0.18 72/22 62.54 30.48 0.00 56.75 27.53 0.00 50.25 24.45 0.00 42.94 21.21 0.00 34.73 17.84 0.00 1000 67/19 51.63 31.28 0.00 45.66 28.17 0.01 38.98 24.93 0.01 31.49 21.55 0.01 23.12 18.06 0.01 62/17 41.65 31.91 0.01 35.51 28.66 0.01 28.71 25.30 0.01 21.89 21.89 0.03 18.26 18.26 0.19 72/22 71.89 34.94 0.00 65.33 31.70 0.00 57.89 28.24 0.00 49.50 24.59 0.00 40.06 20.76 0.00 1200 67/19 59.49 36.20 0.01 52.68 32.73 0.01 45.02 29.06 0.01 36.39 25.22 0.01 26.71 21.21 0.01 62/17 48.10 37.22 0.01 41.07 33.55 0.01 33.27 29.72 0.01 25.77 25.77 0.05 21.51 21.51 0.20 72/22 80.24 38.94 0.00 73.00 35.45 0.00 64.73 31.69 0.00 55.41 27.69 0.01 44.86 23.46 0.01 1400 67/19 66.53 40.71 0.01 58.99 36.93 0.01 50.47 32.91 0.02 40.84 28.66 0.02 29.98 24.20 0.02 62/17 53.91 42.17 0.02 46.10 38.14 0.02 37.43 33.92 0.02 29.46 29.46 0.07 24.60 24.60 0.22 I 72/22 57.24 28.01 0.00 51.64 25.08 0.00 45.46 22.08 0.00 38.59 19.00 0.00 30.99 15.85 0.00 750 67/19 46.98 28.35 0.00 41.29 25.33 0.00 35.01 22.24 0.00 28.09 19.09 0.00 20.47 15.90 0.01 62/17 37.67 28.59 0.01 31.89 25.50 0.01 25.61 22.37 0.01 19.28 19.28 0.02 16.05 16.05 0.19 72/22 69.68 33.97 0.00 62.89 30.52 0.00 55.32 26.92 0.00 46.89 23.21 0.00 37.57 19.40 0.00 950 67/19 57.29 34.68 0.01 50.33 31.06 0.01 42.64 27.33 0.01 34.14 23.51 0.01 24.80 19.63 0.01 62/17 45.99 35.21 0.01 38.92 31.47 0.01 31.24 27.68 0.01 23.90 23.90 0.04 19.89 19.89 0.20 72/22 80.80 39.28 0.00 72.96 35.40 0.00 64.17 31.32 0.00 54.37 27.06 0.01 43.48 22.66 0.01 1150 67/19 66.56 40.46 0.02 58.50 36.34 0.02 49.54 32.05 0.02 39.60 27.64 0.02 28.70 23.15 0.02 62/17 53.51 41.36 0.02 45.29 37.07 0.02 36.38 32.70 0.02 28.26 28.26 0.07 23.51 23.51 0.22 72/22 97.47 47.29 0.00 88.05 42.83 0.00 77.49 38.05 0.01 65.68 33.04 0.02 52.41 27.78 0.02 1500 67/19 80.52 49.40 0.03 70.85 44.58 0.03 60.01 39.53 0.03 47.89 34.25 0.03 34.64 28.83 0.04 62/17 64.96 51.12 0.03 55.02 46.04 0.03 44.30 40.80 0.04 35.27 35.27 0.10 29.34 29.34 0.25 72/22 105.61 51.26 0.00 95.43 46.52 0.01 84.03 41.43 0.03 71.21 36.06 0.03 56.82 30.42 0.03 1700 67/19 87.38 53.92 0.04 76.93 48.80 0.04 65.20 43.40 0.04 52.01 37.70 0.04 37.60 31.83 0.05 62/17 70.60 56.17 0.04 59.87 50.74 0.04 48.32 45.08 0.05 38.96 38.96 0.13 32.40 32.40 0.27 72/22 76.01 37.07 0.00 68.82 33.39 0.00 60.76 29.56 0.00 51.72 25.55 0.00 41.64 21.42 0.00 1050 67/19 62.63 37.91 0.01 55.22 34.04 0.01 46.97 30.03 0.01 37.78 25.89 0.01 27.60 21.64 0.01 62/17 50.40 38.54 0.01 42.81 34.53 0.01 34.49 30.41 0.01 26.28 26.28 0.03 21.90 21.90 0.19 72/22 89.66 43.58 0.00 81.26 39.43 0.00 71.77 35.02 0.00 61.13 30.39 0.00 49.17 25.55 0.01 1300 67/19 74.04 45.04 0.01 65.36 40.60 0.01 55.62 35.94 0.01 44.72 31.09 0.01 32.62 26.09 0.01 62/17 59.73 46.18 0.01 50.78 41.52 0.02 40.97 36.70 0.02 31.77 31.77 0.06 26.48 26.48 0.21 72/22 110.09 53.41 0.00 99.92 48.64 0.00 88.41 43.46 0.01 75.38 37.95 0.02 60.66 32.13 0.02 1750 67/19 91.28 56.16 0.02 80.74 50.96 0.03 68.83 45.42 0.03 55.35 39.55 0.03 40.35 33.42 0.03 62/17 73.94 58.45 0.03 63.04 52.91 0.03 51.08 47.08 0.03 40.82 40.82 0.10 34.04 34.04 0.24 72/22 121.19 58.89 0.00 110.14 53.79 0.01 97.57 48.25 0.02 83.25 42.30 0.03 67.02 35.98 0.03 2050 67/19 100.75 62.56 0.04 89.24 56.99 0.04 76.15 51.01 0.04 61.30 44.63 0.04 44.72 37.88 0.04 62/17 81.81 65.71 0.04 69.88 59.72 0.04 56.88 53.37 0.05 46.27 46.27 0.12 38.60 38.60 0.26 72/22 126.10 61.36 0.00 114.71 56.14 0.02 101.67 50.45 0.03 86.78 44.32 0.03 69.87 37.76 0.04 2200 67/19 104.99 65.51 0.04 93.05 59.79 0.04 79.44 53.62 0.04 63.97 47.02 0.04 46.71 40.00 0.05 62/17 85.35 69.12 0.04 72.98 62.94 0.05 59.55 56.35 0.06 48.85 48.85 0.14 40.75 40.75 0.27 CFM - Cubic Ft per Minute EWB - Entering Wet Bulb (°F / °C) SHC - Gross Sensible Capacity 1000 Btuh BF - Bypass Factor NOTES: 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: Leaving db = entering db -sensible heat cap. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leav- ing coil (hiwb) hlwb = hewb -total capacity_(Btuh) 4.5 x CFM where hewb = enthalpy of air entering coil. Direct inter- polation is permissible. Do not extrapolate. 3. SHC is based on 80°F db temperature of air entering coil. Below 80°F db, subtract (Correction Factor x CFM) from SHC. Above 80°F db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. ESTIMATED SOUND POWER LEVEL (dBA) LWB - Leaving Wet Bulb (°F / °C) TC - Gross Cooling Capacity 1000 Btuh MBH - 1000 Btuh SHC CORRECTION FACTOR ENTERING AIR DRY-BULB TEMPERATURE (°F) BYPASS 79 78 77 76 75 Under 75 FACTOR 81 82 83 84 85 Over 85 Correction Factor 0.10 1.96 2.94 3.92 4.91 .098 Use formula 0.20 0.87 1.74 2.62 3.49 4.36 shown 0.30 0.76 1.53 2.29 3.05 3.82 below Interpolation is permissible. Correction Factor = 1.09 x (1 - BF) x (db - 80) MODEL CONDITIONS OCTAVE BAND CENTER FREQUENCY SIZE CFM ESP 63 125 250 500 1000 2000 4000 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE4ANF002 1000 0.25 65.0 61.0 57.0 56.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 57.8 56.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE4ANF003 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 FE5AN6004 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 400 0.25 61.0 57.0 55.0 50.0 48.0 46.0 42.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 FE4ANF005 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 1400 0.25 66.4 62.4 58.4 57.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 59.0 58.0 54.0 52.0 48.0 600 0.25 62.7 58.7 56.7 51.7 49.7 47.7 43.7 800 0.25 64.0 60.0 58.0 53.0 51.0 49.0 45.0 1000 0.25 65.0 61.0 59.0 54.0 52.0 50.0 46.0 1200 0.25 65.8 61.8 59.8 54.8 52.8 50.8 46.8 FE4ANB006 1400 0.25 66.4 62.4 60.4 55.4 53.4 51.4 47.4 1600 0.25 67.0 63.0 61.0 56.0 54.0 52.0 48.0 1800 0.25 67.5 63.5 59.5 58.5 54.5 52.5 48.5 2000 0.25 68.0 64.0 60.0 59.0 55.0 53.0 49.0 2150 0.25 68.3 64.3 60.3 59.3 55.3 53.3 49.3 *Est. sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, chapter 52, p. 52.7. AIRFLOW PERFORMANCE CORRECTION FACTORS STATIC PRESSURE CORRECTION (in wc) HEATER KW ELEMENTS Sizes 002-005 Size 006 0 0 +.02 +.03 5 1 +.01 +.02 8,10 2 0 0 9,15 3 -.02 -.03 20 4 -.04 -.06 18, 24, 30 6 -.06 -.10 The FE4A airflow performance table was developed using fan coils with 10kW electric heaters (2 elements) in the units. For fan coils with heaters made up of a differ- ent number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use table for this correction. 10 FACTORY -INSTALLED FILTER STATIC PRESSURE DROP (in wc) MODEL CFM FE4A 400 600 800 1000 1200 1400 1600 1800 2000 002 0.020 0.044 0.048 0.072 0.100 003 - 0.020 0.035 0.051 0.070 0.092 - - - 005 - - 0.035 0.051 0.070 0.092 0.120 - - 006 0.038 0.053 0.070 0.086 0.105 0.133 MODEL CFM FE5A 400 600 800 1000 1200 1400 1600 1800 2000 004 - 0.015 0.026 0.038 0.053 0.070 - - - AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (in wc) AT INDICATED AIRFLOW (DRY TO WET COIL) MODEL CFM FE4A 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 002 0.012 0.016 0.022 0.028 0.034 0.040 0.049 003 - 0.026 0.034 0.042 0.052 0.063 0.075 0.083 0.091 0.098 0.110 005 - 0.006 0.008 0.010 0.012 0.015 0.017 0.020 0.023 0.027 0.030 CFM 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 006 0.013 0.016 0.018 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.048 MODEL CFM FE5A 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 004 0.004 0.005 0.007 0.009 0.011 0.013 0.016 0.018 0.020 0.023 - NOTE: Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. UNITS WITHOUT ELECTRIC HEAT BRANCH CIRCUIT UNIT SIZE VOLTS -PHASE FLA MIN CKT AMPS Min Wire Size Awg* Fuse/Ckt Bkr Amps 002 208/230-1 4.3 5.4 14 15 003 208/230-1 4.3 5.4 14 15 005 208/230-1 4.3 5.4 14 15 004,006 208/230-1 6.8 8.5 14 15 * Use copper wire only to connect unit. If other than uncoated (non -plated) 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70). NOTE: If branch circuit wire length exceeds 100 ft / 30.5 m, consult NEC 210-19a to determine maximum wire length. Use 2 % voltage drop. FLA - Full Load Amps ACCESSORY ELECTRIC HEATERS HEATER kW VOLTS/ STAGES (kW INTERNAL FAN COIL HEATING CAP. INTELLIGENT PART NO. @° PHASE OPERATING) CIRCUIT SIZE USED @ 230Vt HEAT CAPABLE 240V PROTECTION WITH (kW OPERATING) KFCEHO501 N05 5 230/1 5 None All 15,700 - KFCEH0901 N10 10 230/1 10 None All 31,400 - KFCEH3001F15 15 230/1 5,15 Fuses** All 47,100 5, 10, 15 KFCEH3201 F20 20 230/1 5,20 Fuses** All 62,800 5, 10, 15, 20 KFCEH2901 N09 9 230/1 * 3,9 None All 28,300 3, 6, 9 KFCEH1601315 15 230/3 5,15 None All 47,100 - KFCEH3401 F24 24 230/3t 8, 16, 24 Fuses 005,006 78,500 8, 16, 24 KFCEH3501 F30 30 230/3t 10, 20, 30 Fuses 005,006 94,200 10, 20, 30 KFCEH2401C05 5 230/1 5 Ckt Bkr All 15,700 - KFCEH2601 C10 10 230/1 10 Ckt Bkr All 31,400 - KFCEH3101C15 15 230/1 5,15 Ckt Bkr All 47,100 5, 10, 15 KFCEH3301C20 20 230/1 5,20 Ckt Bkr All 62,800 5, 10, 15, 20 * Field convertible to 3 phase. t These heaters field convertible to single phase. ** Single point wiring kit required for these heaters in Canada. # Blower motor heat not included. ELECTRIC HEATER INTERNAL PROTECTION HEATER kW PHASE FUSES QTY / SIZE CKT BKR QTY / SIZE* 5 1 - 1/60 8 1 - 1/60 9 1/3 - - 10 1 - 1/60 15 1 2/30, 2/60 2/60 15 3 - - 18 3 - - 20 1 4/60 2/60 24 3/1 6/60 - 30 3/1 6/60 - * All circuit breakers are 2 pole. 11 ACCESSORY ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT P INTERNAL HEATER AMPS kW H 208/230V Min Ampacity Min Wire Size (AWG) Min Gad Wire Size Max Fuse/CM Bkr Amps Max Wire Length HEATER A CIRCUIT 208/230V" 208/230Vtt 208/230V 208/230V 208/230V (fitt PART NO. S PROTEG- E TION Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit Single Dual Circuit 240V 208V Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 KFCEH0501 N05 5 3.8 1 None 18.1/20.0 — — 31.2/33.5 — — 8/8 — — 10/10 — — 35/35 — — 85/88 — — KFCEH2401C05 5 3.8 1 Ckt Bkr 18.1/20.0 — — 31.2/33.5 — — 8/8 — — 10/10 — — 35/35 — — 85/88 — — KFCEH0801N08 8 6.0 1 None 28.9/32.0 — — 44.7/48.5 — — 8/8 — — 10/10 — — 45/50 — — 59/60 — — KFCEH2501C08 8 6.0 1 Ckt Bkr 28.9/32.0 — — 44.7/48.5 — — 8/8 — — 10/10 — — 45/50 — — 59/60 — — KFCEH2901N09* 9 6.8 1 None 32.8/36.0 — — 49.5/53.5 — — 8/6 — — 10/10 — — 50/60 — — 54/87 — — KFCEH2901N09*t 9 6.8 3 None 18.8/20.8 — — 32.0/34.5 — — 8/8 — — 10/10 — — 35/35 — — 83/85 — — KFCEH0901N70 10 7.5 1 None 36.2/40.0 — — 53.8/58.5 — — 6/6 — — 10/10 — — 60/60 — — 78/80 — — KFCEH2601C10 10 7.5 1 Ckt Bkr 36.2/40.0 — — 53.8/58.5 — — 6/6 — — 10/10 — — 60/60 — — 78/80 — — KFCEH3001F75x1 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH3101C1V 15 11.3 1 Ckt Bkr — 36.2/40.0 18.1/20.0 — 53.8/58.5 22.7/25.0 — 6/6 10/10 — 10/10 10/10 — 60/60 25/25 — 78/80 75/76 KFCEH1601315 15 11.3 3 None 31.3/34.6 — — 47.7/51.8 — — 8/6 — — 10/10 — — 50/60 — — 56/90 — — KFCEH2O01318 18 13.5 3 None 37.6/41.5 — — 55.5/60.4 — — 6/6 — — 10/8 — — 60/70 — — 76/77 — — KFCEH3201F20x1 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH3301C2V 20 15.0 1 Ckt Bkr — 36.2/40.0 36.2/40.0 — 53.8/58.5 45.3/50.0 — 6/6 8/8 — 10/10 10/10 — 60/60 50/50 — 78/80 59/59 24 18.0 3 Fuse 50.1/55.4 — — 71.2177.8 — — 4/4 — — 8/8 — — 80/80 — — 94/95 — — KFCEH3401F24*t 24 18.0 1 Fuse 86.7/95.5 — — 116.9/127.9 — — 1/1 — — 6/6 — — 125/150 — — 115/116 — — 30 22.5 3 Fuse 62.6/69.2 — — 86.8/95.0 — — 3/3 — — 8/8 — — 90/100 — — 97/98 — — KFCEH3501F30*t 30 22.5 1 Fuse 109.0/120.0 — — 144.8/158.5 — — 0/00 — — 6/6 — — 150/175 — — 117/150 — — FIELD MULTIPOINT WIRING OF 24-AND 30-kW SINGLE PHASE N P MAX FUSE/CKT BKR kW H HEATER AMPS MIN TY MIN WIRE SIZE (AWG) MIN GND AMPS MAX WIRE LENGTH HEATER PART 208/230V 208/230V8/230V ** 208/230Vtt 208/230V (FT)# A NO. S WIRE SIZE 208/230V 208/230V 240V 208V E L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 KFCEH3401F24*t 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH3501F30*t 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 * Heaters are Intelligent Heat capable when used with the FE fan coil and Comfort Zone II- or Infinity Control-. t Field convertible to 1 phase, single or multiple supply circuit. $ Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. tt Copper wire must be used. If other than uncoated (non —plated), 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). $$ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTES: 1. Single circuit application of F15 and F20 heaters requires single —point wiring kit accessory. ACCESSORIES REQUIRED ACCESSORY ITEM ACCESNOORY PART FAN COIL SIZE USED WITH Infinity@ Touch Control with Integrated Wi—Fi SYSTXCCITC01 All or 1 Infinity@ Touch Control Wi—Fi SYSTXCCITW01 All with bundled router or Infinity@ Touch Control SYSTXCCITN01 All ADDITIONAL ACCESSORIES ITEM ACCESNOORY PART FAN COIL SIZE USED WITH 2. Infinity@ Series 4 Zone Board SYSTXCC4ZC01 All 3. Infinity@ Series Smart Sensor SYSTXCCSMS01—A All 4. Infinity@ Remote Room Sensor SYSTXCCRRS01 All 5. Infinity@ Series Network Interface Module SYSTXCCNIM01 All 6. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3— through 10—kW KFACB0201 CFB 002 7. Downflow Base Kit KFACB0301 CFB 003,005 KFACB0401 CFB 004,006 8. Downflow Conversion Kit KFADCO201 SLIP 003 KFADC0401ACL 002, 004, 005, 006 9. Single —Point Wiring Kit KFASP0101 SPK Only with 15— and 20—kW Fused Heaters KFAFK0212MED 002 10. Filter Kit (12 Pack) KFAFK0312LRG 003,005 KFAFK0412XXL 004,006 FNCCABCCO017 002 11. Filter Media Cabinet FNCCABCCO021 003,005 FNCCABCCO024 004,006 FILCCFNCO017 002 12. Media Filter Cartridges FILCCFNCO021 003,005 FILCCFNCO024 004,006 GAPABXCC1620 002 13. Infinity@ Series Air Purifier GAPABXCC2020 003,005 GAPABXCC2024 004,006 14. PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 15. Air Cleaner 240—volt Conversion Kit KEAVCO201240 All 16. Downflow/Horizontal Conversion Gasket Kit KFAHDO101SLP All 17. Horizontal Water Management Kit (25 pack) KFAHCO125AAA All KFAFR0101 FRM NA 18. Standard Filter Rack Kit KFAFR0201 FRM 002 KFAFR0301 FRM 003,005 KFAFR0401 FRM 004,006 19. Hydronic Relay Interface Kit KFAIF0101 HWC All 20. Door Gasket Kit ** 344994-751 All * Factory authorized and listed, field installed. ** This kit is for replacement of factory installed gaskets if they are damaged or removed from the fan coil. 13 ACCESSORIES (CONT.) Accessory Kits Description Suggested and Required Use 1. Infinity@ Touch Control with Integrated Wi—Fi Deluxe programmable wall —mounted system control with integrated Wi—Fi. or Infinity@ Touch Control Wi—Fi with bundled router Deluxe programmable wall —mounted system control with integrated Wi—Fi. Sold bundled with Wi—Fi router or Infinity@ Touch Control Deluxe programmable wall —mounted system control without remote access. 2. Infinity@ Series 4 Zone Board 4—Zone Damper Control Module wall —mounted control. REQUIRED USE: For all four —zone systems. For systems with 5 to 8 zones, a second Damper Control Module is required. 3. Infinity@ Series Smart Sensor Wall control used to monitor temperature and/or fan control. SUGGESTED USE: For use in zone systems. 4. Infinity@ Remote Room Sensor Wired remote temperature sensor for zone control. SUGGESTED USE: For use in zone systems. 5. Infinity@ Series Network Interface Module Connects Heat Recovery and Energy Recovery Ventilators on non —zoning applications and non —communicating 2—speed units. REQUIRED USE: For non —zoned systems installed with HRV or ERV, Hybrid Heat with non —communicating heatpumps or non — communicating 2—speed units. 6. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3— through 10—kW electric resistance heaters and cooling controls. 7. Downflow Base Kit This kit is designed to provide a 1—in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap —free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 8. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal —left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A —coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 9. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy —gauge, high —voltage wires into the fan coil rather than 4 light —gauge, high —voltage wires. SUGGESTED USE: Fan coils with 15— and 20—kW fused heaters only. 10. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 11. Filter Media Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILCCFNC00(14, 17, 21, 24) media filter cartridges. SUGGESTED USE: All fan coils. 12. Media Filter Cartridges These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 13. Infinity@ Series Air Purifier The Infinity Series Air Purifier wires directly to fan coil and requires no duct transitions with Carrier units. It comes with an airflow sensor. SUGGESTED USE: All fan coils. 14. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre —formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 15. Air Cleaner 240—volt Conversion Kit The AIRA electronic air cleaner comes ready for 115—v operation. REQUIRED USE: This kit is required when running 240—volt circuit to air cleaner. 14 ACCESSORIES (CONT.) 16. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE: Fan coils in either downflow or horizontal applications. 17. Horizontal Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidty. SUGGESTED USE: All fan coils (except FE5 and 17171). 18. Standard Filter Rack Kit This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1—in. filter sizes. SUGGESTED USE: Fan coils using standard filter sizes. 19. Hydronic Relay Interface Kit This kit provides interface of the FE4 and FE5 fan coils with Hydronic Heat equipment. NOTE: Electric heat cannot be used with Hydronic Interface Relay Kit. SUGGESTED USE: All FE4 and FE5 fan coils installed with hydronic heat. 20. Door Gasket Kit This kit consists of specific adhesive —backed foam strips which are applied to the unit door and frame, limiting air leakage. 15 NOTES: Copyright 2019 Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231 Edition Date: 07/19 U.S. Export Classification: EAR99. Catalog No: FE4A-12PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 Replaces: FE4A-11 PD